HomeMy WebLinkAboutA005 Rated Floor and Roof TypesProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Rated Floor and Roof Types THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A005 Revision ID Transmittal Set Date Transmittal Set Name 01 10/5/21 ADLS ISSUE #2 ARCH ONLY 1 1 2 2 3 3 4 4 A B C A B C BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 20219'-0" 9'-1 1/8" Apartment R-11 BATT INSULATION INSIDE FLOOR ASSEMBLY, NO GAPS Corridor (ELEVATIONS ASSUME T/FLR SHEATHING IS 0'-0") 1 HOUR RATING - ROOF/CEILING per U.L. DESIGN P555 FIRE SEALANT AT HEAD OF WALL TO THE UNDER SIDE OF ROOF DECKING. 1 HOUR RATING WP 3370 2x4 WOOD STUDS, MINIMUM 16" oc FOR FIRE RATING. REFERENCE S-SERIES DRAWINGS FOR STRUCTURAL REQUIRED SPACING. SHEATHING FOR SHEAR PANELS REFERENCE S-SERIES DRAWINGS. 5/8" GYPSUM BOARD, LISTED FOR RATED WALL. R-19 BATT INSULATION PLAN VIEW REFERENCE S-SERIES DRAWINGS FOR FIRE AND DRAFT STOPPING PANEL. REVIEW SPECIAL INSTRUCTIONS IN THE S-SERIES DRAWINGS. 5/8" GYPSUM BOARD, LISTED FOR RATED WALL. DRAFT STOPPING MATERIAL AS REQUIRED TO LIMIT 100 SF AREAS PER CODE. R-11 BATT INSULATION 9'-0" 9'-1 1/8" 1 HOUR RATING - FLOOR/CEILING per U.L. DESIGN G564 WALL PLATE AND CONNECTION, REFERENCE S- SERIES DRAWINGS. FLOOR FINISHES AND TRIM, REFERENCE ROOM FINISH SCHEDULE AND INTERIOR DETAILS. LT. WT. TOPPING AND ACOUSTIC PAD 1 LAYER 5/8" GYP. BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY . CSF TRUSSES AND FLOOR DECKING PER UL LISTED ASSEMBLY. REFERENCE S-SERIES DRAWINGS. Corridor Apartment (ELEVATIONS ASSUME T/FLR SHEATHING IS 0'-0") R-11 BATT INSULATION INSIDE FLOOR ASSEMBLY, NO GAPS S6Bi - 1 HOUR RATING - WALL per U.L. DESIGN U423 and U425. Added wood structural panel per notes published in Gypsum Association FIRE RESISTANCE DESIGN MANUAL PLAN 2x6 WOOD STUDS, MINIMUM 16" oc FOR FIRE RATING. REFERENCE S-SERIES DRAWINGS FOR STRUCTURAL REQUIRED SPACING. SHEATHING FOR SHEAR PANELS REFERENCE S-SERIES DRAWINGS. 5/8" GYPSUM BOARD, LISTED FOR RATED WALL. R-19 BATT INSULATION (MINERAL WOOL WHEN BUILDING SEQUENCE REQUIRES INSULATION PRIOR TO WATER TIGHT CONDITIONS). W6Ji - 1 HOUR RATING - WALL per U.L. DESIGN U311 or GA FILE # WP3241. CorridorApartment 2x6 WOOD STUDS, MINIMUM 16" oc FOR FIRE RATING. REFERENCE S-SERIES DRAWINGS FOR STRUCTURAL REQUIRED SPACING. RC CHANNEL @ 12" oc 5/8" GYPSUM BOARD, LISTED FOR RATED WALL. R-19 BATT INSULATION (MINERAL WOOL WHEN BUILDING SEQUENCE REQUIRES INSULATION PRIOR TO WATER TIGHT CONDITIONS). PLAN 1 HOUR RATING - FLOOR/CEILING per U.L. DESIGN G564 LT. WT. TOPPING AND ACOUSTIC PAD 1 LAYER 5/8" GYP. BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY. CEILING MAY ONLY BE INTERRUPTED AT LOAD-BEARING WALLS. NON-LOADING TOP PLATES MUST BE UNDER CEILING SHEATHING. CSF TRUSSES AND FLOOR DECKING PER UL LISTED ASSEMBLY. REFERENCE S-SERIES DRAWINGS. Apartment R-11 BATT INSULATION INSIDE FLOOR ASSEMBLY, NO GAPS 3 HOUR RATING FOR REINFORCED CONCRETE SLAB - FLOOR/CEILING per SFRP on BEAM AND DECK. REINFORCED COMPOSITE CONCRETE SLAB, 8" MINIMUM. REFERENCE S- SERIES DRAWINGS. WALL PLATE AND CONNECTION, REFERENCE S-SERIES DRAWINGS. FLOOR FINISHES AND TRIM, REFERENCE ROOM FINISH SCHEDULE AND INTERIOR DETAILS. ACOUSTIC PAD AT 3RD FLOOR SCALE: 1 1/2"= 1'-0" A2 Roof/Ceiling Assembly 1 A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B2 Roof/Ceiling Assembly 2A A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C2 Floor Assembly 4 A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C4 Demising Wall Section Detail A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A3 Exterior Wall Detail Upper Floor - EIFS A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B3 Exterior Wall Detail Upper Floor - Brick A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C3 Exterior Wall Detail First Floor A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B1 Floor/Ceiling Assembly 2 A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A4a Corridor Wall Assembly A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A4b Corridor Wall Assembly A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C1 Floor/Ceiling Assembly 3 A005 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A1 Floor/Ceiling Assembly 1 A005 0 6''12''18'' SLAB TYPES INTERIOR WALL TYPES EXTERIOR WALL TYPES ROOF / CEILING TYPES FLOOR / CEILING TYPES