Loading...
HomeMy WebLinkAboutA101e3 Enlarged Plan DetailProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Enlarged Plan Detail THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11-26-201911/26/2019 A 10 1e 3 Revision ID Transmittal Set Date Transmittal Set Name 02 11/30/20 ASI 7 A B C D E 1 1 2 2 3 3 4 4 5 5 6 6 A B C D E BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 20215'-1 5/8"2'-5 1/8"2'-8 1/2"1'-9 5/8"2'-3"BACKER ROD AND SEALANT STOREFRONT, REF. SHT. A601 FOR SCHEDULE STEEL COL., REF. S-SERIES DWGS. 3 5/8" LIMESTONE VENEER 8" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. BACKER ROD AND SEALANT STOREFRONT, REF. SHT. A601 FOR SCHEDULE 3 1/2" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. GYPSUM SHEATHING SYSTEM SRFM AT COLUMN AND RELATED STEEL STRUCTURE BRICK VENEER TYPE 1 STONE WATERTABLE BELOW BRICK AND LIMESTONE VENEER, SEE SHEET A215 1'-0"1'-4 7/8"9 3/4"1'-9 7/8"3'-2 3/8"1'-0"7 5/8" 5 3/8" 2 1/4"5'-0 1/4"7 5/8"2'-2 5/8" 5 3/4"9'-2" 9'-0 1/2"2'-8"2'-2 7/8" 1'-4"3'-6 7/8" 8" C.I.P. WALL, REF. S-SERIES DWGS. 3 5/8" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. BRICK TYPE 1 BRICK TYPE 1 8" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. CONCRETE COL. BELOW, REF. S-SERIES DWGS. 8" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. 6" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. SFRM AT COLUMN AND RELATED STEEL STRUCTURE ALUMINUM STOREFRONT SYSTEM 3/4" PLYWOOD W/ BACKER ROD AND SEALANT 2" RIGID INSULATION LIQUID APPLIED MEMBRANE RESIDENTIAL LOBBY 3 5/8" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. 9'-1/2" M.O. 9'-2" R.O. 4 5/8"9'-6"8"2 3/8"3 5/8"5 1/2"9 7/8"3 5/8" 2 1/2" 9 7/8"9 7/8" 2 1/2" 3 5/8"2'-5 3/8"5 7/8"6 1/8"1'-3 3/8"6"2'-11 1/2"1'-9 1/2"11 1/2"9'-10 5/8"3 5/8"2 1/4"1'-7 3/4" 3'-0 3/8"6 1/2"5 1/8"5 1/4"3'-11 3/4"3'-1 3/4"8" C.I.P. WALL, REF. S-SERIES DWGS. 3 5/8" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. BRICK TYPE 1 3 5/8" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. EXIST. CONC COL. BELOW, REF. S-SERIES DWGS. 3 5/8" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. GYPSUM SHEATHING SYSTEM SRFM AT COLUMN AND RELATED STEEL STRUCTURE PUBLIC LOBBY 2' RIGID INSULATION LIQUID APPLIED MEMBRANE APPLIED DRYWALL 2' RIGID INSULATION LIQUID APPLIED MEMBRANE 3/4" PLYWOOD, BACKER ROD AND SEALANT10 3/8"8 1/2"8"4'-0 1/4"7 3/8"7 1/8"1'-2 5/8"4 5/8"8" 6'-5 3/8"1'-0 5/8" 4'-7 5/8"2'-2 3/8"9 7/8"4"1'-6 7/8"4"2"8"3 5/8"2 3/8"6"6'-10"6"7'-1"10 5/8"1'-4 5/8"12'-4 1/2"1'-0"1'-0"11 3/4"2'-8 1/8"2'-0"8'-4 1/2"2'-0"2'-8 1/8"6'-5"11 3/4"1'-0"1'-0"3'-7 3/8"1'-11"6'-6 1/2"1'-11"3'-7 3/8"17'-7 1/4"8" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. BACKER ROD AND SEALANT 3 5/8" LIMESTONE VENEER ABOVE BACKER ROD AND SEALANT EIFS PILASTER ASSEMBLY LIMESTONE AND EIFS ARCHITRAVE ELEMENTS ABOVE. SEE ELEVATIONS SHEET A215 GYPSUM SHEATHING SYSTEM GFRP OR GFRC PILASTER ASSEMBLY, SEE ELEVATION, REF. SAME COLUMN DESIGN WITH METAL FRAMING BACK-UP ALUMINUM STOREFRONT SYSTEM, REF. SHT. A601 FOR SCHEDULE STONE WATERTABLE BELOW BRICK AND LIMESTONE VENEER, SEE SHEET A215 5/8" TREATED PLYWOOD SHEATHING (FIRE RETARDANT)6'-6 1/2" R.O.6'-5" M.O.5 1/4"5 7/8" C5 A221 C4 A221 C5 A221 D1 A318 D1 A318 C5 A221 10 1/2"3 5/8" 1'-2 1/8"12'-4 1/2"1 3/8"1'-9 3/8"1 3/8"8'-4 1/2"1 3/8"1'-9 3/8"1 3/8"1'-5 3/4" CMU GROUT POUR SLAB TO MIDDLE OF THRESHOLD, SEE THRESHOLD DETAIL 4" FLOOR SLAB OVER V.P. & 6" COMPPRESSED GRANULAR FILL FUTURE SLABD1 A318 C5 A221 10 9/16"3 5/8" 1'-2 3/16"12'-4 1/2"1 5/16"1'-9 5/16"1 5/16"8'-5 13/16"1'-9 5/16"1 5/16"GENERAL NOTES: 1 All jamb and head design framing is by the delegated system engineer for the CFS framing. 2 Install the rockwool insulation inside the framed jambs and built up head assemblies. 3 4 02 15 SCALE: 1" = 1'-0" B5 Enlarged 1st Floor Plan A101e3 0 6''1'2'SCALE: 1" = 1'-0" B1 Enlarged 1st Floor Plan A101e3 0 6''1'2' SCALE: 1" = 1'-0" D1 Enlarged 1st Floor Plan A101e3 0 6''1'2' SCALE: 1" = 1'-0" E5 Enlarged 1st Floor Plan A101e3 0 6''1'2'SCALE: 1" = 1'-0" E4 Enlarged Plan Under Pilasters A101e3 0 6''1'2'SCALE: 1" = 1'-0" E3 Enlarged Foundation Plan A101e3 0 6''1'2'