Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A103e1 Enlarged Plan Detail
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Enlarged Plan Detail THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11-26-201911/26/2019 A 10 3 e 1 Revision ID Transmittal Set Date Transmittal Set Name 02 5/10/21 Steel Release #2 BID PHASE II 1 1 2 2 3 3 A B C A B C BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 2021CL1 3/8"6"GYPSUM SHEATHING SYSTEM 2" EXPANSION JOINT FIXED WINDOW, REF. A604 FOR SCHEDULE 6" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. 1 1/2" EIFS2" BUILDING EXPANSION JOINT "CUT IN" AND REPLACE EIFS ON HOTEL W/ CONT. TREATED 2 x 6 SUBSTRATE 3/4" BACKER ROD AND SEALANT AIR SPACE SHAFTLINER SYSTEM ALONG THE 2" EXPANSION JOINT OF THE HOTEL BUILDING HOTEL EIFS CORNICE ABOVE 10 1/2"2"1"7'-10 1/2" 8'-1 1/2" EXISTING HOTEL STRUCTURE EXISTING HOTEL EIFS 3/4"5/8"6"6" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. 1 1/2" EIFS BATT INSULATION ROOF ASSEMBLY BELOW BACKER ROD AND SEALANT TREATED PLYWOOD SHEATHING (FIRE RETARDANT) GYPSUM SHEATHING SYSTEM GUARDRAIL ASSEMBLY GUTTER ASSEMBLY 7 3/8"EQ.EQ. 11'-1 3/4" BRICK TYPE 2 6" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. 1 1/2" EIFS BATT INSULATION 3/8" BACKER ROD AND SEALANT MORTAR, TYP. 3/8" BACKER ROD AND SEALANT TREATED PLYWOOD SHEATHING (FIRE RETARDANT), SAME THICKNESS AS EIFS PATIO DOOR, REF. A604 FOR SCHEDULE GYPSUM SHEATHING SYSTEM 2 1/4"3 5/8"1'-3 3/8"6"1'-7 3/4"5 7/8"9'-11 1/4"4'-9 3/4"5'-1 1/2"1'-3 1/2"1'-7 3/8"7 5/8" CMU WALL, REF. S-SERIES DWGS. BATT INSULATION 1 1/2" EIFS BRICK TYPE 4 3 1/2" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. FIXED WINDOW, REF. A604 FOR SCHEDULE BACKER ROD AND SEALANT TREATED PLYWOOD SHEATHING (FIRE RETARDANT) GYPSUM SHEATHING SYSTEM 1" AIR GAP 3 1/2" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. 6" CFS STUD FRAMING W/ 5/8" EXT. SHEATHING TYP. B5 A312 7 5/8"8'-8"7 5/8"5 1/2"5 1/2" 7 5/8" 1/2"1 1/4" 9 1/4"1 3/4" 1'-0 3/8" 3 1/4"1 1/4" 1 1/8" TYP. ALIGN WD. FRAMING & FINISHED FACE OF GYP. BOARD APARTMENT DEMISING WALL BRICK VENEER W/ WIRE TIES AS SPEC'D. TYP. GYPSUM SHEATHING SYSTEM 3/8" BACKER ROD AND SEALANT TREATED PLYWOOD SHEATHING (FIRE RETARDANT), SAME THICKNESS AS EIFS BRICK VENEER EIFS VENEER EIFS VENEER 5 7/8" TYP. 2 1/4" TYP.3/8" < 1/2"2'-3 7/8"5'-2 1/8"2 7/8"6"4'-10 1/8"1'-10 1/2" 5/8" 6"5'-1" 8 7/8"1'-1 5/8"8 7/8"7'-6"5'-7"BRICK TYPE 1 8" CMU WALL, REF. S-SERIES DWGS. FIXED WINDOW, REF. A604 FOR SCHEDULE 3/8" BACKER ROD AND SEALANT TREATED PLYWOOD SHEATHING (FIRE RETARDANT) FINISH SYSTEM 2" EXPANSION JOINT "CUT IN" AND REPLACE EIFS ON HOTEL W/ CONT. TREATED 2 x 6 SUBSTRATE FOR EXP. JOINT 3/4" BACKER ROD AND SEALANT B4 A303 2"7 5/8"3 1/8"3 5/8"2"± 1'-4" ± 1'-6" ± 8 3/8"7 5/8"6 3/4"1'-2 3/8"8" CMU STUB WALL TIED TO SHAFT WALL EXISTING HOTEL STRUCTURE EXISTING EIFS ON HOTEL AIR GAP EXISTING HOTEL EIFS CORNICE ABOVE TYP. GENERAL NOTES: 1 All jamb and head design framing is by the delegated system engineer for the CFS framing. 2 Install the rockwool insulation inside the framed jambs and built up head assemblies. 3 4 GENERAL NOTES: 1 All jamb and head design framing is by the delegated system engineer for the CFS framing. 2 Install the rockwool insulation inside the framed jambs and built up head assemblies. 3 Plans represent 4th and 5th floor as well. 4 SCALE: 1" = 1'-0" A3 Enlarged 3rd Floor Plan A103e1 0 6''1'2'SCALE: 1" = 1'-0" A2 Enlarged 3rd Floor Plan A103e1 0 6''1'2' SCALE: 1" = 1'-0" C1 Enlarged 3rd Floor Plan A103e1 0 6''1'2'SCALE: 1" = 1'-0" C3 Enlarged 3rd Floor Plan A103e1 0 6''1'2' SCALE: 1" = 1'-0" B1 Enlarged 3rd Floor Plan - Brick to EIFS Transition, TYP. A103e1 0 6''1'2'SCALE: 1" = 1'-0" B2 Enlarged 3rd Floor Plan A103e1 0 6''1'2' SCALE: 1" = 1'-0" A1 Enlarged 3rd Floor Plan A103e1 0 6''1'2'