Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A103RA 3rd Floor Relief Angle Plan - Area A
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC 3rd Floor Relief Angle Plan - Area A THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11-26-201911/26/2019 A 10 3 R A Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 02 7/14/20 5/10/21 Steel Release Steel Release #2 BID PHASE II Existing Stair Renovations, STEEL RELEASE - BID PHASE II 11, 20 Tuesday, October 5, 2021, BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren6 7 8 9 10 1234567898910123456789101112UP1 2 3 32 # Y Z K x17 x17 x23 x23 x22 x21.9 x21.9 x21.5 x21.5 x21.4 x21.4 x21.1 x21.1 x21 x21 x19 x19 x18.1 x18.1 x18 x18 xJ.5xJ.3 H.9 xH.5xG.5xGxF.9xFxE.9 G.8 G.9 H.3 H.4 H.6G.1F.8F.4 XJ.4 20.7 20.7 20.5 20.5 19.7 19.7 19.4 19.4 19.5 21.2 21.2 F.10 H.1 02 11 1'-6 "1'-6"RELIEF ANGLERELIEF ANGLERELIEF ANGLERELIEF ANGLERELIEF ANGLERELIEF ANGLE RELIEF ANGLE RELIEF ANGLE RELIEF ANGLE4'-4 1/4"4'-6"5'-9 3/8"4'-3 1/2"4'-6"20'-11 1/2"4'-6"4'-6"7'-4 1/2" 4'-6"4'-10 1/4" 4'-4 1/4" 4'-4 1/4" 4'-4 1/4"13'-2"4'-6"12'-11 1/8"NOTE: SOLID LINE REPRESENTS OUTSIDE EDGE OF EIFS CORNICE AT THIRD FLOOR NOTE: SOLID DARK LINE REPRESENTS EDGE OF SLAB NOTE: DASHED LINE REPRESENTS OUTSIDE EDGE OF BRICK RELIEF ANGLE. T/RELIEF ANGLE FLUSH WITH T/ 3RD FLOOR SLAB. REF. A300s & S-SERIES DWGS. NOTE: FOR BREAKS IN RELIEF ANGLES AT BALCONY OUTRIGGERS. REF. S413 / S-SERIES DWGS. NOTE: FOR BREAKS IN RELIEF ANGLES AT BALCONY OUTRIGGERS. REF. S413 / S-SERIES DWGS. NOTE: FOR BREAKS IN RELIEF ANGLES AT BALCONY OUTRIGGERS. REF. S413 / S-SERIES DWGS FUTURE FLOOR OPENING. PROVIDE COMPOSITE FLOOR. LINE REPRESENTS EDGE OF SLAB AT THIRD FLOOR NOTE: FOR BREAKS IN RELIEF ANGLES AT BALCONY OUTRIGGERS. REF. S413 / S-SERIES DWGS STL. BALCONY OUTRIGGERS, REF. S- SERIES DWGS. FOR DTLS. STL. BALCONY OUTRIGGERS, REF. S- SERIES DWGS. FOR DTLS. STL. BALCONY OUTRIGGERS, REF. S- SERIES DWGS. FOR DTLS. STL. BALCONY OUTRIGGERS, REF. S- SERIES DWGS. FOR DTLS. STL. BALCONY OUTRIGGERS, REF. S- SERIES DWGS. FOR DTLS. LINE REPRESENTS EDGE OF SLAB AT THIRD FLOOR LINE REPRESENTS EDGE OF SLAB AT THIRD FLOOR LINE REPRESENTS EDGE OF SLAB AT THIRD FLOOR Commercial Tenant 230 G: 12,256.9 sq ft P: 12,256.9 sq ft 345DOWN123456UP 8TREADS#RevID 18 RELIEF ANGLE 4'-6"14'-7"3'-7 1/8"4'-6"19'-2 7/8"4'-4 1/4"4'-4 1/4"4'-4 1/4"3'-9 1/4" 3'-11 1/8"12345678UP123456789UPUP9TREADS(11") UP CL GENERAL NOTES: 1. REFERENCE THIS SHEET FOR LENGTH OF STEEL OUTRIGGERS AND EXTENT OF DIFFERENT STEEL OUTRIGGER LENGTHS ON PLAN. 2. REFERENCE S-SERIES DRAWINGS FOR SPACING OF STEEL OUTRIGGERS. REF. SHEETS A103RB & A103RB FOR SPACING OF STL. OUTRIGGERS AT CANTILEVERED BALCONIES. 3. ALL STL. OUTRIGGERS FOR CORNICES AND BALCONIES TO BE CAPPED ON OUTWARD FACING END, REF. S-SERIES DWGS. 4. ALL STL. OUTRIGGERS EXCEPT THOSE AT BALCONIES ARE TO HAVE HOLES SPACED ON THE SIDES FOR ACCESS OF BLOWN-IN INSUL., REF. S-SERIES DWGS. 5. REFERENCE S-SERIES DRAWINGS FOR DETAIL OF STEEL OUTRIGGERS. 6. COORDINATE PLACEMENT OF OUTRIGGERS BETWEEN CORNICE FABRICATOR AND STEEL FABRICATOR. SCALE: 1/8" = 1'-0" 1 3rd Floor Relief Angle Plan A103RA 0 4'8'16'