Loading...
HomeMy WebLinkAboutA304 Wall SectionProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Wall Section THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A304 Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 02 03 7/14/20 5/10/21 5/26/21 Steel Release Steel Release #2 BID PHASE II Addendum #1- STEEL RELEASE #2 PHASE II STEEL RELEASE - BID PHASE II ADM-STL #1 20 21 1 1 2 2 3 3 4 4 5 5 A B C D A B C D BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 2021NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A215 AND A217. 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD ARE FIRE RETARDANT TREATED FOR FIRST AND SECOND FLOORS, INCLUDING THE WOOD AT ROOF, COPING AND PARAPET DETAILS AT THOSE FLOORS. AREAS ABOVE THE TYPE I CONSTRUCTION AND PART OF THE TYPE V CONSTRUCTION ARE NOT REQUIRED TO BE FIRE RETARDANT. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND WOOD WALL PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. B5 A304 E3 A218 C3 A218 D4 A307 +18'-0" 3rd Floor +28'-8" 4th Floor +39'-4" 5th Floor +50'-0" 6th Floor / Roof 9'-1 1/8" STUD11'-9 1/4"VARIES1 1/2" GYP.10'-1 1/2" FIN.1 3/8"1 1/2"8'-10 3/8"1 3/8"7'-2"1'-6"3/4"1'-6"3/4"9'-1 1/8" STUD15'-11 1/4" FL.-FL.10'-8" FL.-FL.10'-8" FL.-FL.6 1/4"9'-1 1/8"2'-0"17'-10 1/2" BRICK BEARING 49'-10 1/2" T/ BRICK VEER 55'-6 1/2" T/ PARAPET WALL 2'-0 3/4" B5 A303 B5 A303 B5 A303 EIFS CORNICE PROFILE EP9.4 EIFS CORNICE PROFILE EP21.1 EIFS CORNICE PROFILE EP18.2 BRICK VENEER THRU-WALL FLASHING AT FLOOR LINE W/ WEEPS AT 24" O.C. TYPICAL STEEL BEAM, REF. S- SERIES DWGS. STOREFRONT, REF. SHT. A605 CFS BOX HEADER R-21 BATT INSULATION CONC. FOUNDATION WALL, REF. S-SERIES DWGS. EXISTING CONC. STRUCTURE, REF. S- SERIES DWGS. 2" BLDG. EXPANSION JOINT SINGLE HUNG WINDOW BEYOND NEW PLAZA PAVERS, INDICATED ON PLAZA PLAN 8" METAL STUD EXTERIOR WALL WITH EXTR GYPSUM SHEATHING E14653 X 6" LONGAT ANCHOR POINTS T14641 DECORATIVE STONE PANEL SIM. x22 x21.9 14'-0 1/8" B/ STUD FRAMING 13'-10" T/ LIMESTONE VENEER 6" 1 3/4" 8" 1 3/4" 8 1/2"8" 17'-10 1/2" BRICK BEARING GYPSUM SHEATHING SYSTEM (GLASS MAT) LIMESTONE VENEER BACKER ROD AND SEALANT NOTE: SEE C2/A304 FOR ADDITIONAL NOTES SLIP TRACK 6" CFS FRAMING MOISTURE AIR BARRIER JOINT SYSTEM BY GYPSUM SHEATHING SYSTEM 8" CFS FRAMING 5 7/8"5/8"6"3 3/4" 7 7/8" 9 5/8" 6'-5 5/8" T/ LIMESTONE WATERTABLE 8" 8" STONE WATERTABLE, REF. D1/ A215, LIMESTONE BASE PROFILE TYPE 3.1 YORK THRU-WALL COPPER FLASHING W/ FELT BACKING, HEAD WEEP AT EVERY VERTICAL JOINT PAVERS, REF. C4/A308 STL. KICKERS, REF. S- SERIES DWGS. STL. BEAMS AND SUPPORTING COLUMNS, REF. S-SERIES DWGS., APPLY 3 HOUR SFRM CONT. BENT PLATE, REF. S- SERIES DWGS. EXPOXY COATED PRIOR TO CONC. SLAB POUR WABO USG - 24N GUTTER FLEX W/ DRAIN COMPOSITE SLAB, REF. S- SERIES DWGS. NOTE: SEE ADDITIONAL SECTIONS ON SHEET A217. MOISTURE / AIR BARRIER JOINT SILL SEALANT FOR WATERPROOF BARRIER SEE SELECTIVE DEMOLITION PLAN FOR REMOVAL OF EXISTING PLAZA CONCRETE TO FORM A 2" EXPANSION JOINT. S.S. STONE ANCHOR 2'-0"49'-10 1/2" T/ BRICK VENEER 55'-6 1/2" T/ PARAPET WALL EIFS ORNAMENTAL RELIEF EP11.1 EIFS CORNICE PROFILE EP18.2 BRICK VENEER BACKER ROD AND SEALANT 3/4" FIRE RETARDANT PLYWOOD MTL. CHANNELS FOR PLYWD. ANCHORAGE BY EIFS MANUF. 3/4" PRESERVATIVE EXTERIOR TREATED PLYWOOD SHEATHING POLYVINYL CHLORIDE (PVC) ROOFING OVER 5/8" GYPSUM RECOVERY BD., OVER INSUL. OVER 5/8" DENSGLAS SHEATHING, OVER VAPOR BARRIER POLYVINYL CHLORIDE (PVC) ROOF FLASHING GYPSUM SHEATHING SYSTEM (GLASS MAT) PRE-FINISHED METAL COPING W/ DRIP EDGE MINERAL WOOL INSULATION 3/4" PRESERVATIVE EXTERIOR TREATED PLYWOOD SHEATHING PRESERVATIVE TREATED DOUBLE TOP PLATES POLYVINYL CHLORIDE (PVC) ROOF FLASHING 5 7/8"5/8"6" B4 A304 B5 A304 D4 A307 D5 A304 +18'-0" 3rd Floor +28'-8" 4th Floor +39'-4" 5th Floor +50'-0" 6th Floor / Roof49'-10 1/2" T/ BRICK VENEER 55'-6 1/2" T/ PARAPET WALL 17'-10 1/2" BRICK BEARING (T/ ANGLE) 2'-0 3/4" NOTE: FOR LEVEL SECOND THROUGH ROOF, REF. D1/A304 FOR TYP. NOTES STEEL BEAM, REF. S- SERIES DWGS. LIMESTONE VENEER 2" BLDG. EXPANSION JOINT NEW PLAZA PAVERS, INDICATED ON PLAZA PLAN 8" METAL STUD EXTERIOR WALL WITH EXTR GYPSUM SHEATHING LIGHT FIXTURE, REF. E-SERIES DWGS. FUTURE STAIR OPENING SCALE: 1/4" = 1'-0" D1 Wall Section A304 0 2'4'8' SCALE: 1 1/2"= 1'-0" B4 Section Detail A304 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D5 Section Detail - Near Plaza Entries With Veneer Protruding Beyond Plaza Edge A304 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B5 Section Detail A304 0 6''12''18'' SCALE: 1/4" = 1'-0" D3 Wall Section A304 0 2'4'8' B5 A304 E4 A218 C4 A218 D4 A307 +18'-0" 3rd Floor +28'-8" 4th Floor +39'-4" 5th Floor +50'-0" 6th Floor / Roof 17'-10 1/2" BRICK BEARING 49'-10 1/2" T/ BRICK VENEER 55'-6 1/2" T/ PARAPET WALL 2'-0 3/4"2'-0"NOTE: FOR LEVEL SECOND THROUGH ROOF, REF. D1/A304 FOR TYP. NOTES STEEL BEAM, REF. S- SERIES DWGS. LIMESTONE VENEER CFS BOX HEADER 2" BLDG. EXPANSION JOINT NEW PLAZA PAVERS, INDICATED ON PLAZA PLAN 8" METAL STUD EXTERIOR WALL WITH EXTR GYPSUM SHEATHING GFRC COLUMN BEYOND SCALE: 1/4" = 1'-0" D2 Wall Section A304 0 2'4'8' x22 x21.9x22x21.9