Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A325 Partial Wall Sections
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Partial Wall Sections THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A325 Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 10/5/21 ADLS ISSUE #2 ARCH ONLY 1 1 2 2 3 3 4 4 5 5 A B C D A B C D BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 20213/4" EIFS VENEER GYPSUM SHEATHING SYSTEM 3/4" EIFS VENEER OVER 5/8" GYP. SHEATHING SYSTEM 3/4" EIFS VENEER OVER 5/8" GYP. SHEATHING SYSTEM CSF BULKHEAD FRAMING SOFFIT - DIRECT APPLIED EIFS FINISH OVER 5/8" CEMENT FIBER BOARD, APPROVED BY EIFS MANUFACTURE BACKER ROD AND SEALANT PRE-FINISHED METAL FLASHING STRUCT. CFS. BEAM, REF. S-SERIES DWGS. SPLIT GFRC COLUMN CAP 2-PIECE GLASS FIBER REINFORCED CONCRETE COLUMN (GFRC) SIMILAR TO MELTON CLASSICS TUSCAN STRAIGHT DESIGN. 2-HALVES W/ 24" BASE METAL RAILING, HIGH PERFORMANCE COATINGS POLYVINYL CHLORIDE (PVC) ROOFING / LIQUID APPLIED MEMBRANE OVER SLOPED CONC. SLAB RUN UP AND OVER 2X TREATED PLATE 8" MINERAL WOOL INSULATION LOWERED FURRED CEILING FOR PLUMBING. THE RATED CEILING ASSEMBLY MUST BE UTILIZED THROUGHOUT. REF. REFLECTED CEILING PLAN NOTE: REF. S-SERIES DWGS FOR FRAMING DETAILS FIRE RETARDANT BLOCKING AS REQUIRED FOR RESTRAINING THE GFRC COLUMN COVERS. BRACKETING AS REQUIRED FOR RESTRAINING THE GFRC COLUMN COVERS. PEEL AND STICK MEMBRANE 1" TREX DECKING ASSEMBLED IN 24X24 PAVER TILES ON PEDESTALS OVER CONC. SLAB A2 A305 3/4" EIFS VENEER OVER 5/8" GYP. SHEATHING SYSTEM BACKER ROD AND SEALANT PRE-FINISHED METAL FLASHING 3/4" EIFS VENEER OVER 5/8" GYP. SHEATHING SYSTEM GYPSUM SHEATHING SYSTEM 3/4" EIFS VENEER OVER 5/8" GYP. SHEATHING SYSTEM CFS FRAMING SOFFIT - DIRECT APPLIED EIFS FINISH OVER 5/8" CEMENT FIBER BOARD, APPROVED BY EIFS MANUFACTURE FIRE BLOCKING STRUCTURAL METAL TRUSS POLYVINYL CHLORIDE (PVC) ROOFING / LIQUID APPLIED MEMBRANE OVER SLOPED CONC. SLAB RUN UP AND OVER 2X TREATED PLATE 8" MINERAL WOOL INSULATION LOWERED FURRED CEILING FOR PLUMBING. THE RATED CEILING ASSEMBLY MUST BE UTILIZED THROUGHOUT. REF. REFLECTED CEILING PLAN NOTE: REF. S-SERIES DWGS FOR FRAMING DETAILS PEEL AND STICK MEMBRANE 1" TREX DECKING ASSEMBLED IN 24X24 PAVER TILES ON PEDESTALS OVER CONC. SLAB NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A215 AND A217. 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD ARE FIRE RETARDANT TREATED FOR FIRST AND SECOND FLOORS, INCLUDING THE WOOD AT ROOF, COPING AND PARAPET DETAILS AT THOSE FLOORS. AREAS ABOVE THE TYPE I CONSTRUCTION AND PART OF THE TYPE V CONSTRUCTION ARE NOT REQUIRED TO BE FIRE RETARDANT. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND WOOD WALL PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. SCALE: 1 1/2"= 1'-0" D3 Wall Section A325 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D1 Wall Section A325 0 6''12''18''