Loading...
HomeMy WebLinkAboutA326 Partial Wall SectionsProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Partial Wall Sections THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A326 Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 10/5/21 ADLS ISSUE #2 ARCH ONLY 1 1 2 2 3 3 4 4 5 5 A B C D A B C D BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 2021NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A215 AND A217. 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD ARE FIRE RETARDANT TREATED FOR FIRST AND SECOND FLOORS, INCLUDING THE WOOD AT ROOF, COPING AND PARAPET DETAILS AT THOSE FLOORS. AREAS ABOVE THE TYPE I CONSTRUCTION AND PART OF THE TYPE V CONSTRUCTION ARE NOT REQUIRED TO BE FIRE RETARDANT. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND WOOD WALL PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. A1 A502 +50'-0" 6th Floor / Roof 59' T/ PLATE 8'-10 3/8"EIFS CORNICE #Profile Name SLOPE SPLASH BLOCKS SIM. A1 A502 +50'-0" 6th Floor / Roof 59'-11 3/4" T/ PLATE EIFS CORNICE #Profile Name SLOPE SPLASH BLOCKS A1 A502 +50'-0" 6th Floor / Roof 59'-1 1/2" T/ PLATE EIFS CORNICE #Profile NameSLOPE SPLASH BLOCKS S3.5Di THIN BRICK VENEER PREFIN. MTL. COPING W/ DRIP EDGE MTL. CHANNELS FOR PLYWD. ANCHORAGE BY EIFS MANUF. GYPSUM SHEATHING SYSTEM (GLASS MAT) MTL. STUD FURRING ALIGN W/ ADJACENT EXTERIOR WALL 2 X 4 MTL STUD EXTERIOR WALL SEALANT SCALE: 3/8" = 1'-0" B1 Gutter Detail A326 0 2'4'6' SCALE: 3/8" = 1'-0" D1 Gutter Detail at Stair A326 0 2'4'6' SCALE: 3/8" = 1'-0" C1 Gutter Detail at Elev. Lobby A326 0 2'4'6' SCALE: 1 1/2"= 1'-0" D3 WALL SECTION DETAIL A326 0 6''12''18''