A327 Common Interior Wall Sections
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Common Interior Wall Sections THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A327 Revision ID Transmittal Set Date Transmittal Set Name 01 5/10/21 Steel Release #2 BID PHASE II 1 1 2 2 3 3 A B C A B C BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 2021E2 A328 C2 A328 +18'-0" 3rd Floor +28'-8" 4th Floor +39'-4" 5th Floor +50'-0" 6th Floor / Roof 41'-1 1/8"COMPOSITE SLAB, REF. S- SERIES DWGS., TYP. 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS @ 12" O.C.. R-13HD BATT INSULATION 5/8" GYP. BD. OVER CFS STUD FRAMING, REF. APARTMENT UNIT PLANS R-11 BATT INSULATION R-11 BATT INSULATION APARTMENTAPARTMENT 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS R-11 BATT INSULATION HEAD OF WALL FIRE SEALANT 1 HOUR RATED CONTINUOUS APARTMENTAPARTMENT APARTMENTAPARTMENT 3-5/8" CFS STUDS @ 16" O.C., REFERENCE S- SERIES DRAWINGS FOR DIAPHRAM SHEATHING. 5/8" GYP. BD. OVER CFS STUD FRAMING IN ROOF FRAMING SPACE. REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. 3-5/8" CFS STUD FRAMING, REFERENCE S - SERIES DRAWINGS. DIAPHRAGM SHEATHING PER S-SERIES DRAWINGS. A2/ A005 B1/ A005 B1/ A005 B1/ A005 A2/ A005 B1/ A005 HEAD OF WALL FIRE SEALANT 1 HOUR RATED CONTINUOUS HEAD OF WALL FIRE SEALANT 1 HOUR RATED CONTINUOUS LATERAL STIFFENERS AS REQUIRED A1/ A005 CONTINUOUS METAL CLIP FURRED WALL. 2 HOUR WALL WILL REQUIRE PRE- ROCK OF MULTIPLE GYPSUM SHEATHING LAYERS. PROVIDE 1" AIRSPACE BETWEEN WALL TYPES. E3 A328 C3 A328 +18'-0" 3rd Floor +28'-8" 4th Floor +39'-4" 5th Floor +50'-0" 6th Floor / Roof FIRE SEALANT @ GYPSUM WRAP PENETRATION BY TRUSS BEARING COMPOSITE CONCRETE SLAB, REF. S-SERIES DWGS., TYP. R-21HD BATT INSULATION R-11 BATT INSULATION 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS R-21HD BATT INSULATION 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS - REFERENCE THE UL LISTINGS IN THE SET FOR TYPE AND SPACING. R-11 BATT INSULATION R-11 BATT INSULATION ROOF TRUSSES, REF. S- SERIES DWGS. CORRIDOR APARTMENT R-11 BATT INSULATION R-11 BATT INSULATION R-11 BATT INSULATION CORRIDOR CORRIDOR APARTMENT APARTMENT T / WALL TRUSS BEARING INSULATED METAL STUD WALL, REF. S-SERIES DWGS FOR FRAMING AND DIAGRAM SHEATHING. T / WALL TRUSS BEARING T / WALL TRUSS BEARING B1/ A005 C1/ A005 A2/ A005 REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. A4a/ A005 LOAD BEARING AND SHEAR WALL, REFERENCE S- SERIES DRAWINGS. A2/ A005 A4a/ A005 A4a/ A005 A4a/ A005 B1/ A005 A4a/ A005 A4a/ A005 C1/ A005 A1/ A005 A2 A328 A4 A328 +18'-0" 3rd Floor +28'-8" 4th Floor +39'-4" 5th Floor +50'-0" 6th Floor / Roof 10'-8"10'-8"9'-1 1/4"9'-1 1/4"1'-6"9'-2"17'-10 1/2" 28'-6 1/2" 39'-2 1/2"1'-6"9'-2"28'-6 1/2" 39'-2 1/2" Varies 9'-2"Varies28'-6 1/2" 39'-2 1/2"39'-2 1/2" 48'-3 3/4" FIRE SEALANT @ GYPSUM WRAP PENETRATION BY TRUSS BEARING R-11 BATT INSULATION ROOF TRUSSES, REF. S- SERIES DWGS. 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS @ 12" O.C. 2 HOUR SHAFT UL-U425 ASSEMBLY WITH SINGLE WALL APPLICATION FOR LOAD BEARING WALLS NOT ADJACENT TO CORRIDORS. UL-U417 FOR SHAFT WALLS ADJACENT TO CORRIDORS, MAXIMUM HEIGHT :70 FT (PLUS 32 FT USED IN AREA A, PLUS 53'-4" IN AREA B) STEEL BEAM, REF. S- SERIES DWGS. WITH SFRM STEEL PROTECTION ON BEAMS AND SLAB. CORRIDOR APARTMENT ROOF TRUSS BEARING CORRIDORAPARTMENT CORRIDORAPARTMENT GIRDER TRUSS, REFERENCE S-SERIES DRAWINGS REFERENCE NOTES BELOW FOR EACH FLOOR. REFERENCE NOTES BELOW FOR EACH FLOOR. 5/8" TYPE 'C' GYP. BD. ON RESILIENT CHANNELS @ 12" O.C. MECHANICAL CURB AND COVER, REFERENCE THE M & H SERIES DRAWINGS. LOADBEARING, 2 HOUR UL - U425: iNFILL WALL BETWEEN TRUSSES WITH CFS FRAMING AS REQUIRED. UL - U417: 2 HOUR SHAFT WALL SUPPORTED BY SLAB AND BEAMS ALONG CORRIDOR AT RESIDENTIAL FLOORS. A2/ A005 A2/ A005 B1/ A005 COMPOSITE CONCRETE SLAB, REF. S-SERIES DWGS., TYP. B1/ A005 FIRE BLOCK OR FIRE SEALANT BETWEEN WALL ASSEMBLIES. 1 1/2" ACCOUSTIC TOPPING, REF. SHT. A520 FOR ACOUSTIC TOPPING DETAILS REFERENCE NOTES BELOW FOR EACH FLOOR. B1/ A005 B1/ A005 FIRE SEALANT BETWEEN WALL ASSEMBLY AND SLAB. UL - U417: 2 HOUR SHAFT WALL SUPPORTED BY SLAB. FIRE SEALANT AT HEAD OF WALL TO STEEL BEAM/SFRM/SLAB CFS BEAM/BOX HEADER WRAPPED FOR 2 HOUR PROTECTION LINED ROCK WOOL INSULATION UNDER CAP. R30. REFLECTIVE SIDE DOWN. RETAIN IN PLACE WITH LT. GAUGE METAL STUDS ACROSS SHAFT. ALIGN INNER FACE OF 1" PANEL TO EOS OF 3RD FLOOR. A1/ A005 CONTINUOUS METAL CLIP FURRED WALL. 2 HOUR WALL WILL REQUIRE PRE- ROCK OF MULTIPLE GYPSUM SHEATHING LAYERS. PROVIDE 1" AIRSPACE BETWEEN WALL TYPES. NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A215 AND A217. 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD ARE FIRE RETARDANT TREATED FOR FIRST AND SECOND FLOORS, INCLUDING THE WOOD AT ROOF, COPING AND PARAPET DETAILS AT THOSE FLOORS. AREAS ABOVE THE TYPE I CONSTRUCTION AND PART OF THE TYPE V CONSTRUCTION ARE NOT REQUIRED TO BE FIRE RETARDANT. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND WOOD WALL PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. 2'-3/4" R-24 BATT INSULATION NER 258 ASSEMBLY, 2 HOUR AT ALL 3RD FLOOR SLAB PENETRATIONS. SCALE: 1/2" = 1'-0" C1 Demising Wall Section A327 0 1'2'4' SCALE: 1/2" = 1'-0" C2 Corridor Wall Section A327 0 1'2'4' SCALE: 1/2" = 1'-0" C3 Shaft Wall Section A327 0 1'2'4'