Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A416 Existing Stair
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Existing Stair THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11-26-201911/26/2019 A 4 16 Revision ID Transmittal Set Date Transmittal Set Name 04 6/29/21 ASI #12 1 1 2 2 3 3 A B C A B C BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 20211 A102e3 1 A102e3 C2 A416 C3 A416 D2 A306 D1 A306 11'-8"23'-0" C2 A306 A3 A416 REMOVE PORTION OF PC WALL PANEL DOWN TO +2'-0" ELEV. ON NORTH AND EAST SIDES OF STAIR, REF. B1/ A413. REMEDIAL WORK REQUIRED: ATTACH PC PANELS BELOW DUE TO THE REMOVAL OF THE PANEL TO PANEL CONNECTIONS. PROVIDE CONNECTIONS AT CORNERS AND MIDDLE RUN OF WALL PANELS. PC STAIR WALL TO REMAIN ON WEST AND SOUTH SIDES REMOVE CANOPY AND ALL SUPPORTING STRUCTURE REMOVE PC STAIR, REPAIR AND REPLACE ANY DAMAGED PAVER DURING STAIR REMOVAL REMOVE PC TOP LANDING, HALF OF INTERMEDIATE LANDING, AND TOP STAIR RUN PC STAIR WALL TO REAMIN ON WEST AND SOUTH SIDES REMOVE PORTION OF PC WALL PANEL DOWN TO +2'-0" ELEV. ON NORTH AND EAST SIDES OF STAIR, REF. B1/ A413 SAW CUT TOPPING AT PRECAST JOINT BELOW. REMOVE TOP OF OUTER WALL DOWN TO T/CONC SLAB BELOW PAVERS AS SHOWN IN D2/A306. REMOVE TOP OF OUTER WALL DOWN TO T/ CONC SLAB BELOW PAVERS AS SHOWN IN D2/ A306. 1 A102e3 C2 A413 23'-0" REMOVE PORTION OF PC WALL PANEL DOWN TO +2'-0" ELEV. ON NORTH AND EAST SIDES OF STAIR REMOVE CANOPY AND ALL SUPPORTING STRUCTURE REMOVE PC TOP LANDING, HALF OF INTERMEDIATE LANDING AND TOP STAIR RUN REMOVE PC STAIR, REPAIR AND REPLACE ANY DAMAGED PAVERS DURING STAIR REMOVAL REMOVE PORTION OF WALL BELOW +2'-0" ELEVATION TO ACCOMODATE NEW PC STAIR LANDING AT NEW STOREFRONT ENTRY DOOR CONCRETE STRUCT. WALL TO REMAIN NOTE: PATCH AND REPAIR DAMAGED PC PANELS DURING UPPER PANEL AND STAIR REMOVAL REMEDIATE THE TOP OF WALL AFTER REMOVAL OF THE LEDGE AND TOP OF WALL TO RECEIVE NEW STEEL SUPPORT. COORDINATE THE EXTENT OF REMOVAL IN ACCORDANCE WITH THE NEW LANDING BEING FABRICATED. REMOVE SUPPORT LEDGE UNDER LANDING EXISTING SUPPORT LEDGE UNDER LANDING TO REMAIN XPC STAIR WALL TO REMAIN ON WEST AND SOUTH SIDES FIRST FLOOR PC STAIR AND LANDING TO REMAIN PC STAIR WALL TO REMAIN BELOW +2'-0" ELEV. MATCH EXISTING LANDING 9 EQ. TREADS @ 1'-0" EA 6'-9 3/4" +1'-2" MATCH GRADE OF PLAZA PAVERS EX'G LANDING ELEV. 23' 1'2'-10"1'2'-10"CONCRETE STRUCT. WALL TO REMAIN NEW PC STAIR NEW PC LANDING NEW PC LANDING EXTEND PAVERS WHERE PC STEPS WERE REMOVED STOREFRONT SYSTEM, REF. SHT. A604 T/ PC STAIR WALL AT DOOR NEW TOP OF PC STAIR WALL AT NORTH AND EAST SIDES NEW PC LANDING NEW STEEL SUPPORT ANGLE. ENGINEER FOR DEAD AND LIVE LOAD OF NEW PRECAST STAIR AND LANDING COMPONENT. EXISTING SUPPORT LEDGE UNDER LANDING TO REMAIN THIN BRICK VENEER - EXTEND DOWN TO LANDING OR P.C. STAIR TREAD (ALL FOUR SIDES) RECONFIGURE EXISTING HANDRAILS 10 EQ. RISERSPC STAIR WALL TO REMAIN ON WEST AND SOUTH SIDES FIRST FLOOR PC STAIR AND LANDING TO REMAIN PC STAIR WALL TO REMAIN BELOW +2'-0" ELEV. 1 A102e3 1 A102e3 C2 A416 C3 A416 D2 A306 D1 A306 A3 A416 NEW STUD WALL ABOVE EXISTING PC STAIR WALL ON WEST AND SOUTH SIDES NEW STUD WALL ABOVE EXISTING PC STAIR WALL, NOTE PORTION OF EXISTING PC STAIR WALL ON NORTH AND EAST SIDES WAS REMOVED DURING DEMO, REF. A1/A413 AND B1/ A413 NEW STUD WALL ABOVE EXISTING PC STAIR WALL ON WEST AND SOUTH SIDES NEW PC LANDING NEW PC STAIR EXTEND PAVER WHERE PC STEPS WERE REMOVED ALIGN INSIDE FACE OF GYP. BD. WITH EXIST. PC. WALL BELOW ON NORTH AND EAST WALLS ALIGN INSIDE FACE OF GYP. BD. WITH EXIST. PC. WALL BELOW ON NORTH AND EAST WALLS NEW STEEL SUPPORT ANGLE. ENGINEER FOR DEAD AND LIVE LOAD OF NEW PRECAST STAIR AND LANDING COMPONENT. PROVIDE SEALANT AT JOINT THIN BRICK VENEER, EXTEND DOWN TO LANDING OR P.C. STAIR TREAD THIN BRICK VENEER, EXTEND DOWN TO LANDING OR P.C. STAIR TREAD RECONFIGURE EXISTING HAND- RAIL, SEE SECTION Existing Stair 1 A102e3 C2 A413 +18'-0" 3rd Floor EX'G LANDING ELEV. MATCH GRADE OF PLAZA PAVERS +1'-2" THIN BRICK VENEER - EXTEND DOWN TO LANDING OR P.C. STAIR TREAD (ALL FOUR SIDES) EXIST. PC STAIR EXISTING SUPPORT LEDGE UNDER LANDING TO REMAIN NEW STEEL SUPPORT ANGLE. ENGINEER FOR DEAD AND LIVE LOAD OF NEW PRECAST STAIR AND LANDING COMPONENT. NEW PC LANDING NEW TOP OF PC STAIR WALL AT NORTH AND EAST SIDES EXTEND PAVERS WHERE PC STEPS WERE REMOVED CONCRETE STRUCT. WALL TO REMAIN NEW PC LANDING T/ PC STAIR WALL AT DOOR PC STAIR WALL TO REMAIN BELOW +2'-0" ELEV. FIRST FLOOR PC STAIR AND LANDING TO REMAIN MATCH EXISTING LANDING PC STAIR WALL TO REMAIN ON WEST AND SOUTH SIDES PC STAIR WALL TO REMAIN ON WEST AND SOUTH SIDES E3 A411 SIM. NEW PC STAIR NEW PC LANDING NEW PC LANDING STOREFRONT SYSTEM, REF. SHT. A604 RECONFIGURE EXISTING HANDRAILS FIRST FLOOR PC STAIR AND LANDING TO REMAIN 04 22 04 22 SCALE: 1/4" = 1'-0" A1 2nd Floor - Existing Stair Demo Plan A416 0 2'4'8' SCALE: 1/4" = 1'-0" C1 Existing Stair Demo Section A416 0 2'4'8'SCALE: 1/4" = 1'-0" C2 Stair Section Looking North A416 0 2'4'8' SCALE: 1/4" = 1'-0" A2 2nd Floor -Stair Plan A416 0 2'4'8' SCALE: 1/4" = 1'-0" C3 Stair Section Looking South A416 0 2'4'8' SCALE: 1/4" = 1'-0" A3 Stair Section Looking North (2) A416 0 2'4'8'