Loading...
HomeMy WebLinkAboutA417 Elevator 6Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Elevator 6 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11-26-201911/26/2019 A 4 17 Revision ID Transmittal Set Date Transmittal Set Name 02 5/10/21 Steel Release #2 BID PHASE II A B C D 1 1 2 2 3 3 4 4 A B C D BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 2021PIT DEPTHINTERFACE BOXINTERFACE BOX 8" CIP REINFORCED SHAFT WALLS, REFERENCE STRUCTURAL DOCUMENTS. 8" CMU REINFORCED SHAFT WALLS, REFERENCE STRUCTURAL DOUCUMENTS. 8" CMU REINFORCED SHAFT WALLS, REFERENCE STRUCTURAL DOUCUMENTS. MASONRY CONCRETE LINTEL. REFERENCE THE ELEVATOR MANUFACTURER REQUIREMENTS FOR THE ROUGH OPENING HEIGHT AND WHICH LEVELS REQUIRE IT. INSTALL INFILL CMU FOR FINAL FINISH OPENING AFTER CAB INSTALLATION IS COMPLETE. E4 A413 E4 A413 A3 A413 E4 A413 +18' 2 3rd Floor +28'-8" 3 4th Floor +39'-4" 4 5th Floor +50' 5 6th Floor / Roof 5'-0"17'-9"15'-11"10'-8"10'-8"13'-6 1/4"12'-9 3/4"2'-0 3/4" -14' -15'-8"12'-7 3/4"16'-1"15'-11"10'-8"10'-8"TO THE BOTTOM OF REFUGE SPACEMINIMUM TO TOP OF HOISTWAYSTEEL HOISTWAY BEAM. REFERENCE STRUCTURAL DOCUMENTS.TO THE BOTTOM OF REFUGE SPACEMINIMUM TO TOP OF HOISTWAY2nd Floor Tenant Landing HeightB/ HOISTWAY BM.REFERENCE S-SERIES DRAWINGS FOR FRAMING 4" RIGID INSULATION, TAPERED, PVC ROOFING Hotel Landing Height +18' 2 3rd Floor +28'-8" 3 4th Floor +39'-4" 4 5th Floor +50' 5 6th Floor / Roof STEEL HOISTWAY BEAM. REFERENCE STRUCTURAL DOCUMENTS. 8" CMU REINFORCED SHAFT WALLS, REFERENCE STRUCTURAL DOCUMENTS. SHAFT CAP. REFERENCE S-SERIES DRAWINGS 4" RIGID INSULATION, TAPERED, PVC ROOFING 8" CIP REINFORCED SHAFT WALLS, REFERENCE STRUCTURAL DOCUMENTS. D-11 A413 D3 A417 D2 A417 13'-3 1/8"14'-6 1/2"8"7'-7"8" 6'-5 5/8"8'-11"8"11'-11 1/8"8"REVIEW DOOR SIZE AND LOCATION REQUIRED BY THE ELEVATOR MANUFACTURER. REVIEW DOOR SIZE AND LOCATION REQUIRED BY THE ELEVATOR MANUFACTURER. Elev. 6 D3 A417 D2 A417 13'-2 3/4"14'-6 7/8"7 5/8" 7'-7" 7 5/8"7 5/8"11'-11 1/2"7 5/8"8'-10 1/4" REVIEW DOOR SIZE AND LOCATION REQUIRED BY THE ELEVATOR MANUFACTURER. REVIEW DOOR SIZE AND LOCATION REQUIRED BY THE ELEVATOR MANUFACTURER. Elev. 6 Hous e keepi ng D3 A417 D2 A417 18'-0 1/2"8"11 3/4"4 3/4"13'-5 3/4"8"11'-11 1/8"8"7'-9"REVIEW DOOR SIZE AND LOCATION REQUIRED BY THE ELEVATOR MANUFACTURER. REVIEW DOOR SIZE AND LOCATION REQUIRED BY THE ELEVATOR MANUFACTURER. Sump Pit 122 13'-3 1/8"14'-6 1/2"1'-10 1/2"7 1/2"1'-5"5'-4 7/8" 1'-0 3/4" 9'-6 3/8" 8"7'-7"8"7 3/8" 2'-0 1/2"5'-5 1/4"13'-4 3/8"4 3/4"1'-1"Elev. 6 16 1 2 3 4 5 6 D4 A412 D3 A417 D2 A417 D3 A418 D2 A418 18'-1/2"8"7'-5 3/4"2'-10 1/4"8" 3'-5 1/4"7'-1 1/2"2'-1 5/8" 8" 10'-7"2'-1 1/2" 8"4'-6"11 3/4"17'-11 3/4"4 3/4"13'-5 3/4"8"11'-11 1/8"8"7'-9" C8 C81ST35 TREADS @ 11" EA.11 TREADS @ 11" EA.REVIEW DOOR SIZE AND LOCATION REQUIRED BY THE ELEVATOR MANUFACTURER. REVIEW DOOR SIZE AND LOCATION REQUIRED BY THE ELEVATOR MANUFACTURER. REVIEW DOOR SIZE AND LOCATION REQUIRED BY THE ELEVATOR MANUFACTURER. SLAB STEP SLAB STEP T/SLAB = -14-0" T/SLAB = -15-8" Sump Pit Sump Pit Vestibule 122 13'-3 1/8"14'-6 1/2"8'-4"1"6'-9 1/2"8"7'8"1'-10 1/2"4'-3"5'-2"2'-6"8"7 1/2"1'-5"5'-4 7/8" 1'-3/4" 9'-6 3/8" 8"7'-7"8"7 3/8" 1 2 UP 4567891011DOWNGUARDRAIL BELOW STAIR4'-2"8"9'-8"4'-7"10'-6 1/8"8" 9'-2 1/8" 8" 2'-1/2"5'-5 1/4"13'-4 3/8"10'-1"10'-4"4 3/4"1'-1"Stair 3 1STR3 Elev. 6 16 Elev. 7 17 D2 A324 +18'-0" 3rd Floor 8'-0" FRAME OPENING 2 3/4" 8'-2 3/4" xG.5 B4 A417 D1 A322 2'-6"8 3/4"8'-0"2 3/4"3'-2 3/4"8'-2 3/4"SCALE: 1/4" = 1'-0" D3 Elevator 6 Section A417 0 2'4'8'SCALE: 1/4" = 1'-0" D2 Elevator 6 Section A417 0 2'4'8' SCALE: 1/4" = 1'-0" B1 2nd Floor Elevator Plan A417 0 2'4'8' SCALE: 1/4" = 1'-0" C1 3rd to 5th Floor Elevator Plan A417 0 2'4'8' SCALE: 1/4" = 1'-0" A1 1st Floor Elevator Plan A417 0 2'4'8' SCALE: 1/4" = 1'-0" D4 1st Floor Slab Plan A417 0 2'4'8' SCALE: 1/4" = 1'-0" B4 West Court Low Roof Access Section A417 0 2'4'8' SCALE: 1/4" = 1'-0" A4 West Court Low Roof Access Plan A417 0 2'4'8' corrected 01-22-2021