Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A607 Storefront Details
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Storefront Details THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A607 Revision ID Transmittal Set Date Transmittal Set Name 01 10/5/21 ADLS ISSUE #2 ARCH ONLY 1 1 2 2 3 3 A B C A B C BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Tuesday, October 5, 20210 1/4"6 1/2"1 3/4"9 1/4"CFS STUD BACKER ROD AND SEALANT BEHIND RAINSCREEN PANEL PER STOREFRONT REQUIREMENTS STOREFRONT ASSEMBLY SHIM AS NEEDED GYPSUM SHEATHING SYSTEM BACKER ROD AND SEALANT 'J' MOLD CORNER BEAD MOLD FINISH OPENING SEE ELEVATIONS ROCK WOOL INSULATION AT CRIPPLES, BATT INSULATION AT WALL CAVITY LIMESTONE NOTE: STOREFRONT ASSEMBLY INCLUDES ENCLOSED SIDES AGAINST WALL ASSEMBLY. 5/8" TREATED PLYWOOD SHEATHING (FIRE RETARDANT) 3 1/2"3"3" BACKER ROD AND SEALANT BACKER ROD AND SEALANT CORNER BEAD MOLD R.O.= M.O. at HEAD CONDITION (SEE ELEVATIONS) E14653 X 6" LONGAT ANCHOR POINTS T14641 STOREFRONT ASSEMBLY YORK THRU-WALL COPPER FLASHING W/ FELT BACKING, HEADS WEEPS @ 24" O.C. HEAD LIMESTONE HEAD GYPSUM SHEATHING SYSTEM PAINTED GALV. STL. LINTEL, REF. S-SERIES DWGS. CFS BOX HEADER, PROVIDE ROCK WOOL INSULATION HEAD JOINT WEEP FILLER BRICK VENEER BATT INSULATION 5 3/4"6 1/2"4"8"CIP CONCRETE WALL, REF. TO STRUCTURAL 4" CONC. SIDEWALK, REF. TO CIVIL STOREFRONT ASSEMBLY STOREFRONT FRAMING MEMBER BEYOND FOUNDATION WALL (REF. STRUCTURAL) BRICK WATER TABLE BEYOND DRYWALL BEYOND SLAB ON COMPACTED FILL 1/2" EXPANSION JOINT RIGID INSULATION STOREFRONT FRAMING MEMBER BEYOND WATERTABLE BEYOND 4"6 1/2"5 3/4" 4" THRESHOLD SET IN ASPHALTIC MASTIC 4" STOOP SLAB SLOPED AT 1/4":1'-0", REF. TO CIVIL INT. FUTURE SLAB ON COMPACTED FILL, REF. A & S- SERIES DRWGS. DRYWALL BEYOND 1/2" EXPANSION JOINT RIBBON SLAB SIDEWALK, REF. CIVIL DRWGS. COORDINATE LOCATION OF BREAK W/ THE STOREFRONT TRADE #5 REBAR @ 12" O.C. 1-1/2" RIGID INSULATION 2"X4" TREATED WOOD @ DOOR 5 1/4" 1 1/4" BACKER ROD AND SEALANT BACKER ROD AND SEALANT R.O.= M.O. at HEAD CONDITION SEE ELEVATIONS 1 E14653 X 6" LONGAT ANCHOR POINTS T14641 STOREFRONT ASSEMBLY YORK THRU-WALL COPPER FLASHING W/ FELT BACKING, HEADS WEEPS @ 24" O.C. LIMESTONE HEAD GYPSUM SHEATHING SYSTEM PAINTED GALV. STL. LINTEL, REF. S-SERIES DWGS. CFS BOX HEADER, PROVIDE BATT INSULATION HEAD JOINT WEEP FILLER BRICK VENEER 3/4" 1/4"3"6 1/2"4"3"3 1/2"BACKING ROD AND SEALANT BACKING ROD AND SEALANT 5/8" FIRE-RETARDANT PLYWOOD SHEATHING J-MOLD STOREFRONT WINDOW SYSTEM BRICK VENEER BRICK RETURN AT JAMBS BACKER ROD AND SEALANT SHIM AS NEEDED GYPSUM SHEATHING SYSTEM CORNER BEAD MOLD R.O.= MASONRY OPENING +1 1/2" MASONRY OPENING@ DOUBLE MONARCH BRICK@ MODULAR BRICKROCK WOOL INSULATION AT CRIPPLES, BATT INSULATION AT WALL CAVITY NOTE: STOREFRONT ASSEMBLY INCLUDES ENCLOSED SIDES AGAINST WALL ASSEMBLY. 0 1/4"6 1/2"1 3/4"CFS STUD BACKER ROD AND SEALANT BEHIND RAINSCREEN PANEL PER STOREFRONT REQUIREMENTS STOREFRONT ASSEMBLY SHIM AS NEEDED GYPSUM SHEATHING SYSTEM BACKER ROD AND SEALANT FINISH OPENING SEE S.F. ELEVATIONS ROCK WOOL INSULATION AT CRIPPLES, BATT INSULATION AT WALL CAVITY THIN BRICK VENEER (INTERIOR) NOTE: STOREFRONT ASSEMBLY INCLUDES ENCLOSED SIDES AGAINST WALL ASSEMBLY. STONE BASE BELOW THIN BRICK VENEER (EXTERIOR)1 1/4"1/2"7 1/4"1/2"1 1/4"2X TREATED BUCK (FIRE RETARDANT) SCALE: 3" = 1'-0" B2 Storefront Jamb Detail A607 0 3''6''9'' SCALE: 3" = 1'-0" A1 Storefront Head Detail A607 0 3''6''9'' SCALE: 3" = 1'-0"C3 STOREFRONT SILL DETAIL 0 3''6''9''SCALE: 3" = 1'-0" C1 Storefront Sill Detail A607 0 3''6''9''SCALE: 3" = 1'-0" C2 Storefront Sill Detail A607 0 3''6''9'' SCALE: 3" = 1'-0" A2 Storefront Head Detail A607 0 3''6''9'' SCALE: 3" = 1'-0" B1 Storefront Jamb Detail A607 0 3''6''9''SCALE: 3" = 1'-0" B3 Storefront Jamb Detail @ Thin Brick A607 0 3''6''9'' storefront cap