Loading...
HomeMy WebLinkAboutAF101A 1st Floor Fire Protection Plan - Area AProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC 1st Floor Fire Protection Plan - Area A THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A F 10 1A Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 02 7/14/20 5/26/21 Steel Release Addendum #1- STEEL RELEASE #2 PHASE II ADM-STL #1 21 Tuesday, October 5, 2021, BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren32 # Y Z K x23 x23 x22 x21.5 x21.5 x21.4 x21.4 x21.1 x21.1 x21 x21 x19 x19 x18.1 x18.1 x18 x18 xJ.5xJ.3 xG.5xGxF.9xFxE.9 21.2 21.2 F.10 2'-0"FLOOR PLANAREA AFLOOR PLANAREA BMATCH LINEFLOOR PLANAREA AFLOOR PLANAREA BMATCH LINE 90 89919295969493989799100 101102103104 112113114115 116 119118117 128127 129 153151152 154 136137138 267266265 DSVDSVDSVDSV 130 128127 139 147148149150 136 135 1 HOUR SPRAY-APPLIED FIRE RESISTIVE MATERIAL (SFRM) UL DESIGN DECK: D902 UL DESIGN BEAMS: N759 UL DESIGN COLUMNS: X790 2 HOUR SPRAY-APPLIED FIRE RESISTIVE MATERIAL (SFRM) UL DESIGN DECK: D902 UL DESIGN BEAMS: N759 UL DESIGN COLUMNS: X790 3 HOUR SPRAY-APPLIED FIRE RESISTIVE MATERIAL (SFRM) UL DESIGN DECK: D902 UL DESIGN BEAMS: N759 UL DESIGN COLUMNS: X790 2 HOUR INTUMESCENT PAINT AND SEALER (AND FINAL COLOR COAT) UL DESIGN DECK: D902 UL DESIGN BEAMS: N614 UL DESIGN COLUMNS: X649 GENERAL FIRE PROTECTION PLAN NOTES: 1. Review Detail 3/AF102B pertaining to fire protection, CMU wall construction at columns. 2. Shading on plans indicates the regions to receive fire protection with a corresponding rating. Columns below framing represented on a given floor shall be the most restrictive rating indicated by the shading of all floors supported above them. See the legend for various rating types. 3. Areas of exposed SFRM to exterior environments such as parking garage, the drive through and areas subject to traffic and moderate abuse. Unless otherwise indicated, use SFRM design for such applications. 4. Apply SFRM on secondary steel supporting elements including those supporting stair landings and attachments through shaft wall systems per the IBC code. FIRE PROTECTION PLAN NOTES: 1 Columns in the drive through area receive SFRM. Beams may require another type per the shading symbol. 1231 2 3 4 5 6 1234567891011123456789101112131234UP1234567UP1 2 3 4 5 UP 1234567891011DOWN SCALE: 1/8" = 1'-0" 1 1st Floor Fire Protection Plan AF101A 0 4'8'16'