Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AF101B 1st Floor Fire Protection Plan - Area B
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC 1st Floor Fire Protection Plan - Area B THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A F 10 1B Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 02 7/14/20 5/26/21 Steel Release Addendum #1- STEEL RELEASE #2 PHASE II ADM-STL #1 21 Tuesday, October 5, 2021, BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wrenx16 x16 x15 x15 x14 x14 1.7 1.7 x13 x12 x12 x11 x11 xJ xG.5xGxF.9xFxE.9 F.10 1'-0"5'-0"2'-0"1 1 1 1 FLOOR PLANAREA AFLOOR PLANAREA BMATCH LINEFLOOR PLANAREA AFLOOR PLANAREA BMATCH LINE 153151152 175 173174 154 176 177 178 179 180 2 1/4"VENEER EXTERIOR SHEATHING DRYWALL HEAD OF WALL ASSEMBLY W/ 3" DEEP LEG TRACK, SEE S- SERIES DWGS SPRAY APPLIED FIRE RESISTIVE MATERIAL (SFRM) CFS STUD FRAMING, NOT TO ENCROACH ON FIRE PROTECTION TYPICAL CFS STUD FRAMING, SEE S-SERIES DWGS 5/8" GAP IN EXTERIOR SHEATHING AT THE BOTTOM OF DEEP LEG TRACK. RIGID FIRE PROTECTION BOARD, IN LIEU OF SFRM AS REQUIRED TO BOTTOM OF BOARDPENDING ACCEPTANCEFROM LOCALAUTHORITIES.VENEER EXPANSION JOINT: SEE ELEVATIONS OR WALL SECTIONS FOR LOCATION.1 1/4"TYPICAL CFS STUD FRAMING, SEE S-SERIES DWGS TYPICAL HEAD OF WALL ASSEMBLY W/ DEEP LEG TRACK OR STUD ATTACHMENT CLIP, SEE S-SERIES DWGS SPRAY APPLIED FIRE RESISTIVE MATERIAL ON BEAM & OVERSPRAY ON OUTRIGGERS VENEER EXTERIOR SHEATHING DRYWALL 5/8" GAP IN EXTERIOR SHEATHING AT THE BOTTOM OF DEEP LEG TRACK. RIGID FIRE PROTECTION BOARD, IN LIEU OF SFRM AS REQUIREDPENDING ACCEPTANCEFROM LOCALAUTHORITIES.TO BOTTOM OF BOARD (IN ABSENCE OF SHELF ANGLE)1231 2 3 4 5 6 1234567891011123456789101112131234UP1234567UP1 2 3 4 5 UP 1234567891011DOWN GENERAL FIRE PROTECTION PLAN NOTES: 1. Review Detail 3/AF102B pertaining to fire protection, CMU wall construction at columns. 2. Shading on plans indicates the regions to receive fire protection with a corresponding rating. Columns below framing represented on a given floor shall be the most restrictive rating indicated by the shading of all floors supported above them. See the legend for various rating types. 3. Areas of exposed SFRM to exterior environments such as parking garage, the drive through and areas subject to traffic and moderate abuse. Unless otherwise indicated, use SFRM design for such applications. 4. Apply SFRM on secondary steel supporting elements including those supporting stair landings and attachments through shaft wall systems per the IBC code. FIRE PROTECTION PLAN NOTES: 1 Columns in the drive through area receive SFRM. Beams may require another type per the shading symbol. SCALE: 1/8" = 1'-0" 1 1st Floor Fire Protection Plan AF101B 0 4'8'16' SCALE: 1 1/2"= 1'-0" 2 Fireproofing Detail AF101B 0 6''12''18'' SCALE: 1 1/2"= 1'-0" 3 Fireproofing Detail AF101B 0 6''12''18''