Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AF102A 2nd Floor Fire Protection Plan - Area A
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC 2nd Floor Fire Protection Plan - Area A THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A F 102 A Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 02 7/14/20 5/26/21 Steel Release Addendum #1- STEEL RELEASE #2 PHASE II ADM-STL #1 21 Tuesday, October 5, 2021, BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren32 # Y Z K x17 x17 x23 x23 x22 x21.9 x21.9 x21.5 x21.5 x21.4 x21.4 x21.1 x21.1 x21 x21 x19 x19 x18.1 x18.1 x18 x18 xJ.5xJ.3 xH.5xG.5xGxF.9xFxE.9 21.2 21.2 F.10 FLOOR PLANAREA AFLOOR PLANAREA BMATCH LINEFLOOR PLANAREA AFLOOR PLANAREA BMATCH LINE SEE STRUCTURALSEE STRUCTURALSPRAYED-APPLIED FIRE PROOFING FIRE-STOPPING (CAULK) 1, 2 & 3 HOUR RATED FRAMING AND FLOOR ASSEMBLIES UL DESIGNS WITH VULCRAFT DECK 2VLI AND THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK TYPE 300 (INTERIOR) & ISOLATEK TYPE 400 (EXTERIOR AND EXPOSED TO ELEMENTS AND EXTREME TEMPERATURES): UL DESIGN D902 - FOR 1, 2 AND 3 HOUR DECK ASSEMBLIES, UL DESIGN N759 – FOR BEAMS ONLY STEEL ANGLES, REF S- SERIES DRAWINGS UNRESTRAINED DESIGN UL MINIMUM REQUIREMENT: 6x6 - W1.4xW1.4. SEE STRUCTURAL FOR DESIGN MINIMUM. CMU WALL OR METAL STUD. HOLD TOP OF WALL BELOW BEAM 1/2" MIN. LIGHT WEIGHT CONCRETE AT 1,2 & 3 HOUR ASSEMBLIES 345678910DOWN6 7 8 9 10 123451234567898910891011123456789101112UP1 2 3 CL CL345DOWN1234567UP123456UP8TREADSCL CL CL CL GENERAL FIRE PROTECTION PLAN NOTES: 1. Review Detail 3/AF102B pertaining to fire protection, CMU wall construction at columns. 2. Shading on plans indicates the regions to receive fire protection with a corresponding rating. Columns below framing represented on a given floor shall be the most restrictive rating indicated by the shading of all floors supported above them. See the legend for various rating types. 3. Areas of exposed SFRM to exterior environments such as parking garage, the drive through and areas subject to traffic and moderate abuse. Unless otherwise indicated, use SFRM design for such applications. 4. Apply SFRM on secondary steel supporting elements including those supporting stair landings and attachments through shaft wall systems per the IBC code. FIRE PROTECTION PLAN NOTES: 1 Columns in the drive through area receive SFRM. Beams may require another type per the shading symbol. SCALE: 1/8" = 1'-0" 1 2nd Floor Fire Protection Plan AF102A 0 4'8'16' SCALE: 1 1/2"= 1'-0" 2 Fireproofing Detail AF102A 0 6''12''18''