Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AF102B 2nd Floor Fire Protection Plan - Area B
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC 2nd Floor Fire Protection Plan - Area B THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 A F 102 B Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 02 7/14/20 5/26/21 Steel Release Addendum #1- STEEL RELEASE #2 PHASE II ADM-STL #1 21 Tuesday, October 5, 2021, BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wrenx17 x17 x16 x16 x15 x15 x14 x14 13.9 13.9 1.7 1.7 x13 x12 x12 x11 x11 xJ xH.5xG.5xGxF.9xFxE.9 F.10 FLOOR PLANAREA AFLOOR PLANAREA BMATCH LINEFLOOR PLANAREA AFLOOR PLANAREA BMATCH LINE 345678910DOWN6 7 8 9 10 123451234567898910891011123456789101112UP1 2 3 CL CL345DOWN1234567UP123456UP8TREADSCL CL CL CL>2"<2"SPRAYED-APPLIED FIRE PROOFING CMU & AAC AT RATED WALL RATED COLUMN ASSEMBLY WHERE RATED CMU &AAC WALL ENGAGES COLUMN AT FLANGE MASONRY ANCHOR, REFERENCE S-SERIES DRAWINGS WIRE LATHE PER U.L. REQUIREMENTS UL DESIGNS USING THE FOLLOWING SPRAY-APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK TYPE 300 (INTERIOR). TYPE 400 (EXTERIOR AND EXPOSED TO ELEMENTS AND EXTREME TEMPERATURES): UL DESIGN X790 5/8" GYPSUM BOARD VAPOR RETARDER METAL STUDS E.O.S. 5/8" EXTERIOR SHEATHING NOTCH STUD TRACK WHERE REQUIRED FOR COLUMN FLANGES SPRAY APPLIED FIRE RESISTIVE MATERIAL REDUCTION OF CFS STUD FRAMING SIZE PERMITTED ONLY AT COLUMNS WHERE TYPICAL SPACING OF STUDS CANNOT BE ACHIEVED TO ALLOW FOR PROPER APPLICATION OF FIREPROOFING, REDUCED STUDS MUST BE ATTACHED TO COLS. CFS STUD FRAMING THAT MAKES CONTACT WITH COLUMNS, TO BE ATTACHED AND SPRAYED W/ FIRE-RESISTIVE MATERIAL AT SAME TIME AS COLUMN E.O.S. UL DESIGNS USING THE FOLLOWING SPRAY- APPLIED FIRE RESISTIVE MATERIALS: ISOLATEK TYPE 300 (INTERIOR). TYPE 400 (EXTERIOR AND EXPOSED TO ELEMENTS AND EXTREME TEMPERATURES): UL DESIGN X790 GENERAL FIRE PROTECTION PLAN NOTES: 1. Review Detail 3/AF102B pertaining to fire protection, CMU wall construction at columns. 2. Shading on plans indicates the regions to receive fire protection with a corresponding rating. Columns below framing represented on a given floor shall be the most restrictive rating indicated by the shading of all floors supported above them. See the legend for various rating types. 3. Areas of exposed SFRM to exterior environments such as parking garage, the drive through and areas subject to traffic and moderate abuse. Unless otherwise indicated, use SFRM design for such applications. 4. Apply SFRM on secondary steel supporting elements including those supporting stair landings and attachments through shaft wall systems per the IBC code. FIRE PROTECTION PLAN NOTES: 1 Columns in the drive through area receive SFRM. Beams may require another type per the shading symbol. SCALE: 1/8" = 1'-0" 1 2nd Floor Fire Protection Plan AF102B 0 4'8'16' 3 Fireproofing Detail AF102B 2 Fireproofing Detail AF102B