HomeMy WebLinkAboutEL107B - 7TH FLOOR LIGHTING PLAN - AREA BM
P
M
P
M
P
M
P
N/L
N/L
N/L
N/LN/L
N/L
H1 - 63
'K5'
H1 - 63
'L13'
EM - 13
'K5'
EM - 13
'L10'
EM - 13
'L12'
H1 - 63
'X1'
EM - 13
'L10'
EM - 13
'L10'
H1 - 63
'X1'
H1 - 63
'L11'
H1 - 63
'L11'
EM - 13
'L10'
EM - 13
'L11'
H1 - 63
'K8-E'
N/L
H1 - 63
'L11'
H1 - 63
'K16'
EM - 13
'L12'
EM - 13
'L10'
EM - 13
'L11'
EM - 13
'L11'
EM - 13
'L11'
EM - 13
'L11'
EM - 13
'L11'
GENERAL SHEET NOTES
A. SEE SHEET E-001 FOR SYMBOLS AND ABBREVIATIONS.
B. REFER TO SHEET E-501 FOR LIGHTING FIXTURE SCHEDULE.
C. SEE SHEETS E-501 THROUGH E-503 FOR PANEL SCHEDULES.
D. SEE SHEETS E-601 THROUGH E-602 FOR ELECTRICAL DETAILS.
E. COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH ARCHITECTURAL
REFLECTED CEILING PLANS, ARCHITECTURAL ELEVATIONS, MECHANICAL
EQUIPMENT, DIFFUSERS, SUPPORTS, PIPING, DUCTWORK AND STRUCTURAL
PLANS PRIOR TO ROUGH-IN AND INSTALLATION OF LIGHTS.
F. ALL MOUNTING HEIGHTS NOTED ON THE PLANS ARE TO THE BOTTOM OF THE
FIXTURES UNLESS NOTED OTHERWISE.
G. LOCATE CEILING MOUNTED OCCUPANCY SENSORS TO PROVIDE COMPLETE
AREA COVERAGE OF THE SPACE THEY ARE INSTALLED IN. SELECT PROPER
SENSOR COVERAGE PATTERN FROM MANUFACTURER'S PRODUCT DATA TO
DETERMINE COVERAGE. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF
COVERAGE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND THE
MANUFACTURER. SENSORS SHALL INCLUDE ALL POWER SUPPLIES AND
RELAYS NECESSARY FOR PROPER OPERATION.
H. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED
OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER.
USE STRANDED CONDUCTOR FOR LARGER SIZES.
I. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO
MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR
DESIGNER.
J. LABEL ALL RELAYS AND POWER SUPPLIES (ON THE DEVICE OR ON THE BOX
THEY ARE CONNECTED TO) WITH THE AREA THE DEVICES SERVES, THE
BRANCH CIRCUIT IT CONTROLS AND THE DEVICE ADDRESS (IF APPLICABLE).
K. EMERGENCY LIGHTING SHOWN ON THIS DRAWING INDICATES CODE
REQUIRED EMERGENCY LIGHTING FED FROM THE "EMERGENCY BRANCH" OF
THE ESSENTIAL ELECTRICAL SYSTEM.
L. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ROOM AND AREA
FINISHES, CEILING PLANS, DOOR SWINGS, FIRE-RATED PARTITIONS, CABINET
AND CASEWORK AND BUILT-IN DETAILS.
M. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES
AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT.
N. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO
BUILDING LINES.
O. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF
FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE
RESISTANCE OF MATERIALS AND CONSTRUCTION.
P. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND
RAIN TIGHT.
Q. TYPE K8E FIXTURES AT STAIRS TO BE MOUNTED AT +8'-0" A.F.F. TO BOTTOM
OF LIGHT FIXTURE UNLESS NOTED OTHERWISE.
R. THE EC IS RESPONSIBLE FOR VERIFYING (FIELD VERIFICATION IF
NECESSARY) ALL PENDANT LENGTHS.
S. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHT OF
EXTERIOR BUILDING MOUNTED LIGHT FIXTURE TYPES 'K9', 'K10', 'K2' AND
EMR.
T. EXIT SIGNS MOUNTED ABOVE DOORS TO BE +0'-6" ABOVE FINISHED DOOR
FRAME TO BOTTOM OF EXIT SIGN. EXITS NOT LOCATED ABOVE DOOR TO BE
MOUNTED AT 7'-6" AFF TO BOTTOM OF EXIT SIGN UNLESS NOTED
OTHERWISE.
U. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHT OF
EXTERIOR LIGHT FIXTURE. TYPES 'K9', 'K10', 'K2' AND 'EMR'.
19030
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS750 Veterans WayKEYPLAN
B
A
NOT FOR
CONSTRUCTION
EL107B
7TH FLOOR LIGHTING
PLAN - AREA B
11/24/2111/24/21
1/8" = 1'-0"
7TH FLOOR LIGHTING PLAN - AREA B10 16'8'4'
N 11/24/2111/24/21 BUILDING SHELL
BID PHASE III