HomeMy WebLinkAboutH-301 - ENLARGED HVAC PLANSTTT
T
TT24/10 G565
FCU-1
12/106/6 SG50
SG 12/6
195
SG 12/6
200
SG 12/6
120
7"ø
7"ø
7"ø
5"ø
EF-1 16/101
1
1
1
2
3
4
5
6
7
8
910
G-
24/10
6ø
4ø
G -
24/10 6
DBF-1
FD
SG 12/6
200
6/6 SG50
SG 12/6
120
SG 12/6
195 FCU-1
24/10 G565
7"ø
5"ø
7"ø 12/1016/10
1
1
1
2
1
10
5
7 8 9
3
4EF-1 6 G-
24/10
7"ø
4ø
6ø
DBF-1
FD
G -
24/10
6
FCU-1
12/10
EF-1
6/6 SG50
SG 6/6
50
SG 12/6
165
12/6 SG100
12/6 SG100
SG 6/6
100
7"ø
7"ø
5"ø
7"ø
5"ø
5"ø
24/10 G565
1
1
1
1
1
1
2
2
3
4
5
9876ø4øDBF-1
G -
24/10
6
6
G-
24/106
FD
12/10
SG 6/6
50
SG 6/6
50
12/6 SG165
12/6 SG50
12/6 SG150
EF-1
5"ø
7"ø
7"ø
7"ø
5"ø
1
1
1
1
2
3
4
5
7
8
9
1
4ø
6ø
DBF-1
FCU-1
12/1024/10 G565
10
6G-
24/10
FD
G-
24/106
FCU-1
EF-1
7"ø
7"ø
7"ø
5"ø
5"ø
6/6 SG50
SG 6/6
50
12/6 SG175
12/6 SG175
SG 12/6
115
1
1
1
1
1
2
3
4
5
7 8 9
6ø
4ø
24/10 G565
DBF-1
6
G -
24/10 6
G -
24/10 6
EF-1
FCU-1
12/10G -
24/10
6/6 SG50
SG 6/6
50
12/6 SG165
12/6 SG200
12/6 SG100
1
1
1
1
1
3
4
2
2
5
9
8
7
DBF-1
6
24/10 G565
6
G -
24/10 6
FD
11700201
No.
STATE OFJOSEPHR.BO
L
Y
ARDPROFES
S ION A L E N G INEERLICENSE EXPIRES 07/31/22
DATE SIGNED 11/24/21
R E G I S TER
E
D
I
ND I A N A
19030
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID
PHASE III
H-301
ENLARGED HVAC
PLANS
11/24/2111/24/21
RWEH
1/4" = 1'-0"
Unit Type A1 Enlarged HVAC Plan1
1/4" = 1'-0"
Unit Type A2 Enlarged HVAC Plan2
SHEET PLAN NOTES
1 FURNISH AND INSTALL CEILING RADIATION DAMPER AT ALL LOCATIONS
WHERE GRILLES PENETRATE A FIRE RATED CEILING.
2 TERMINATE EXHAUST DUCT WITH WALL VENT. CUSTOM COLOR TO BE
SELECTED BY ARCHITECT. BASIS OF DESIGN FOR VENT CAP IS DEFLECTO
MODEL HSB4W. SEE ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS.
3 FURNISH AND INSTALL DRYER BOX PER MANUFACTURER'S INSTRUCTIONS.
MOUNT BOTTOM OF DRYER BOX AT NOMINAL 6" ABOVE FINISHED FLOOR FOR
STANDARD DRYERS AND COORDINATE INSTALLATION HEIGHT FOR
STACKABLE DRYERS. SEAL AROUND BOX PERIMETER. INSTALL LABEL
SHOWING EQUIVALENT LENGTH OF INSTALLED DRYER VENT (INCLUDING
NUMBER OF ELBOWS) PER MECHANICAL CODE.
4 FURNISH AND INSTALL BATHROOM EXHAUST FAN EF-1 IN WALL. USE ONLY
SMOOTH RADIUS ELBOWS (R/D = 1.5). MAINTAIN 4"ø DUCTWORK IN WALL
THROUGH ELBOW. FLAIR OUT TO 6"ø DUCT ABOVE CEILING.
5 FURNISH AND INSTALL 7 DAY PROGRAMMABLE THERMOSTAT WITH THE TOP
48" ABOVE FINISHED FLOOR.
6 FURNISH AND INSTALL TRANSFER GRILLE 6" ABOVE TOP OF DOOR.
SHEETMETAL TO BE INSTALLED THROUGH THE WALL. PAINT BLACK ANY
STUDS THAT INTERSECT BLACK.
7 PROVIDE FLEXIBLE CONNECTION TO FCU DISCHARGE BEFORE CONNECTION
TO SUPPLY DUCTWORK. FURNISH AND INSTALL FIRE DAMPER WHERE DUCT
PENETRATES RATED CEILING PARTITION.
8 PROVIDE TRAPPED 3/4" CPVC CONDENSATE DRAIN LINE AND TERMINATE
ABOVE HUB-DRAIN LOCATED IN MECHANICAL CLOSET. DO NOT BLOCK FILTER
ACCESS.
9 ROUTE REFRIGERANT LINES UP TO ABOVE CEILING AND OVER TO FURRED
OUT WALL. ROUTE UP TO ROOF, THEN TO APPROPRIATE CONDENSING UNIT
SERVING THIS APARTMENT. SEE ROOF LEVEL HVAC PLANS FOR CONDENSING
UNIT LOCATIONS AND DESIGNATIONS. REFRIGERANT LINES SIZED PER
MANUFACTURER'S RECOMMENDATIONS.
10 FURNISH AND INSTALL RETURN GRILLE HIGH ON WALL, TIGHT TO CEILING.
1/4" = 1'-0"
Unit Type A3 Enlarged HVAC Plan3
1/4" = 1'-0"
Unit Type A4 Enlarged HVAC Plan4
1/4" = 1'-0"
Unit Type A5 Enlarged HVAC Plan5
1/4" = 1'-0"
Unit Type A6 Enlarged HVAC Plan6