Loading...
HomeMy WebLinkAboutH-301 - ENLARGED HVAC PLANSTTT T TT24/10 G565 FCU-1 12/106/6 SG50 SG 12/6 195 SG 12/6 200 SG 12/6 120 7"ø 7"ø 7"ø 5"ø EF-1 16/101 1 1 1 2 3 4 5 6 7 8 910 G- 24/10 6ø 4ø G - 24/10 6 DBF-1 FD SG 12/6 200 6/6 SG50 SG 12/6 120 SG 12/6 195 FCU-1 24/10 G565 7"ø 5"ø 7"ø 12/1016/10 1 1 1 2 1 10 5 7 8 9 3 4EF-1 6 G- 24/10 7"ø 4ø 6ø DBF-1 FD G - 24/10 6 FCU-1 12/10 EF-1 6/6 SG50 SG 6/6 50 SG 12/6 165 12/6 SG100 12/6 SG100 SG 6/6 100 7"ø 7"ø 5"ø 7"ø 5"ø 5"ø 24/10 G565 1 1 1 1 1 1 2 2 3 4 5 9876ø4øDBF-1 G - 24/10 6 6 G- 24/106 FD 12/10 SG 6/6 50 SG 6/6 50 12/6 SG165 12/6 SG50 12/6 SG150 EF-1 5"ø 7"ø 7"ø 7"ø 5"ø 1 1 1 1 2 3 4 5 7 8 9 1 4ø 6ø DBF-1 FCU-1 12/1024/10 G565 10 6G- 24/10 FD G- 24/106 FCU-1 EF-1 7"ø 7"ø 7"ø 5"ø 5"ø 6/6 SG50 SG 6/6 50 12/6 SG175 12/6 SG175 SG 12/6 115 1 1 1 1 1 2 3 4 5 7 8 9 6ø 4ø 24/10 G565 DBF-1 6 G - 24/10 6 G - 24/10 6 EF-1 FCU-1 12/10G - 24/10 6/6 SG50 SG 6/6 50 12/6 SG165 12/6 SG200 12/6 SG100 1 1 1 1 1 3 4 2 2 5 9 8 7 DBF-1 6 24/10 G565 6 G - 24/10 6 FD 11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFES S ION A L E N G INEERLICENSE EXPIRES 07/31/22 DATE SIGNED 11/24/21 R E G I S TER E D I ND I A N A 19030 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID PHASE III H-301 ENLARGED HVAC PLANS 11/24/2111/24/21 RWEH 1/4" = 1'-0" Unit Type A1 Enlarged HVAC Plan1 1/4" = 1'-0" Unit Type A2 Enlarged HVAC Plan2 SHEET PLAN NOTES 1 FURNISH AND INSTALL CEILING RADIATION DAMPER AT ALL LOCATIONS WHERE GRILLES PENETRATE A FIRE RATED CEILING. 2 TERMINATE EXHAUST DUCT WITH WALL VENT. CUSTOM COLOR TO BE SELECTED BY ARCHITECT. BASIS OF DESIGN FOR VENT CAP IS DEFLECTO MODEL HSB4W. SEE ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS. 3 FURNISH AND INSTALL DRYER BOX PER MANUFACTURER'S INSTRUCTIONS. MOUNT BOTTOM OF DRYER BOX AT NOMINAL 6" ABOVE FINISHED FLOOR FOR STANDARD DRYERS AND COORDINATE INSTALLATION HEIGHT FOR STACKABLE DRYERS. SEAL AROUND BOX PERIMETER. INSTALL LABEL SHOWING EQUIVALENT LENGTH OF INSTALLED DRYER VENT (INCLUDING NUMBER OF ELBOWS) PER MECHANICAL CODE. 4 FURNISH AND INSTALL BATHROOM EXHAUST FAN EF-1 IN WALL. USE ONLY SMOOTH RADIUS ELBOWS (R/D = 1.5). MAINTAIN 4"ø DUCTWORK IN WALL THROUGH ELBOW. FLAIR OUT TO 6"ø DUCT ABOVE CEILING. 5 FURNISH AND INSTALL 7 DAY PROGRAMMABLE THERMOSTAT WITH THE TOP 48" ABOVE FINISHED FLOOR. 6 FURNISH AND INSTALL TRANSFER GRILLE 6" ABOVE TOP OF DOOR. SHEETMETAL TO BE INSTALLED THROUGH THE WALL. PAINT BLACK ANY STUDS THAT INTERSECT BLACK. 7 PROVIDE FLEXIBLE CONNECTION TO FCU DISCHARGE BEFORE CONNECTION TO SUPPLY DUCTWORK. FURNISH AND INSTALL FIRE DAMPER WHERE DUCT PENETRATES RATED CEILING PARTITION. 8 PROVIDE TRAPPED 3/4" CPVC CONDENSATE DRAIN LINE AND TERMINATE ABOVE HUB-DRAIN LOCATED IN MECHANICAL CLOSET. DO NOT BLOCK FILTER ACCESS. 9 ROUTE REFRIGERANT LINES UP TO ABOVE CEILING AND OVER TO FURRED OUT WALL. ROUTE UP TO ROOF, THEN TO APPROPRIATE CONDENSING UNIT SERVING THIS APARTMENT. SEE ROOF LEVEL HVAC PLANS FOR CONDENSING UNIT LOCATIONS AND DESIGNATIONS. REFRIGERANT LINES SIZED PER MANUFACTURER'S RECOMMENDATIONS. 10 FURNISH AND INSTALL RETURN GRILLE HIGH ON WALL, TIGHT TO CEILING. 1/4" = 1'-0" Unit Type A3 Enlarged HVAC Plan3 1/4" = 1'-0" Unit Type A4 Enlarged HVAC Plan4 1/4" = 1'-0" Unit Type A5 Enlarged HVAC Plan5 1/4" = 1'-0" Unit Type A6 Enlarged HVAC Plan6