HomeMy WebLinkAboutH-304 - ENLARGED HVAC PLANST TT T EF-1 EF-1 2 1 1 4 3 1 1 1 1 4 2 7 8 9 5 6ø6ø FCU-3 SG 12/6 285 SG 6/6 50 SG 12/6 170 SG 12/6 170 SG 12/6 250 6/6 SG50 20/20 G975 13 G- 24/10 G - 24/10 6 6 4ø DBF-1 5"ø7"ø 7"ø 7"ø 7"ø 5"ø 14/12FD FCU-2 EF-1 EF-114/107"ø 7"ø 7"ø 5"ø5"ø SG 12/6 150 6/6 SG50 12/6 SG125 SG 12/6 150 1 1 1 1 1 2 3 4 4 5 7 8 910 11 12 12/6 SG150 1SG6/6 50 24/12 G675 FD 7"ø 6ø4ø7"ø DBF-1 FD 6ø5øFCU-2 EF-1 EF-1 14/105"ø 7"ø 7"ø 7"ø 7"ø 5"ø 12/6 SG150 SG 6/6 50 SG 6/6 50 SG 12/6 150 SG 12/6 150 12/6 SG125 1 1 1 1 1 1 5 2 2 3 4 4 987 24/12 G675 6ø6ø DBF-1 6 G - 24/10 G - 24/10 6 6 FD 14/10 12/6 SG150 12/6 SG125 SG 12/6 150 12/6 SG1506/6 SG50 6/6 SG50 1 1 1 1 1 1 2 2 3 4 4 5 987 6 FCU-2 24/12 G675 5"ø 7"ø 7"ø 7"ø 7"ø 5"ø 6øEF-1 EF-1 FD 6ø4ø6ø G- 24/10 G - 24/10 6 6 DBF-1 11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFES S ION A L E N G INEERLICENSE EXPIRES 07/31/22 DATE SIGNED 11/24/21 R E G I S TER E D I ND I A N A 19030 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID PHASE III H-304 ENLARGED HVAC PLANS 11/24/2111/24/21 RWEH 1/4" = 1'-0" Unit Type B8 Enlarged HVAC Plan4 SHEET PLAN NOTES 1 FURNISH AND INSTALL CEILING RADIATION DAMPER AT ALL LOCATIONS WHERE GRILLES PENETRATE A FIRE RATED CEILING. 2 TERMINATE EXHAUST DUCT WITH WALL VENT. CUSTOM COLOR TO BE SELECTED BY ARCHITECT. BASIS OF DESIGN FOR VENT CAP IS DEFLECTO MODEL HSB4W. SEE ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS. 3 FURNISH AND INSTALL DRYER BOX PER MANUFACTURER'S INSTRUCTIONS. MOUNT BOTTOM OF DRYER BOX AT NOMINAL 6" ABOVE FINISHED FLOOR FOR STANDARD DRYERS AND COORDINATE INSTALLATION HEIGHT FOR STACKABLE DRYERS. SEAL AROUND BOX PERIMETER. INSTALL LABEL SHOWING EQUIVALENT LENGTH OF INSTALLED DRYER VENT (INCLUDING NUMBER OF ELBOWS) PER MECHANICAL CODE. 4 FURNISH AND INSTALL BATHROOM EXHAUST FAN EF-1 IN WALL. USE ONLY SMOOTH RADIUS ELBOWS (R/D = 1.5). MAINTAIN 4"ø DUCTWORK IN WALL THROUGH ELBOW. FLAIR OUT TO 6"ø DUCT ABOVE CEILING. 5 FURNISH AND INSTALL 7 DAY PROGRAMMABLE THERMOSTAT WITH THE TOP 48" ABOVE FINISHED FLOOR. 6 FURNISH AND INSTALL TRANSFER GRILLE 6" ABOVE TOP OF DOOR. SHEETMETAL TO BE INSTALLED THROUGH THE WALL. PAINT BLACK ANY STUDS THAT INTERSECT. 7 PROVIDE FLEXIBLE CONNECTION TO FCU DISCHARGE BEFORE CONNECTION TO SUPPLY DUCTWORK. FURNISH AND INSTALL FIRE DAMPER WHERE DUCT PENETRATES RATED CEILING PARTITION. 8 PROVIDE TRAPPED 3/4" CPVC CONDENSATE DRAIN LINE AND TERMINATE ABOVE HUB-DRAIN LOCATED IN MECHANICAL CLOSET. DO NOT BLOCK FILTER ACCESS. 9 ROUTE REFRIGERANT LINES UP TO ABOVE CEILING AND OVER TO FURRED OUT WALL. ROUTE UP TO ROOF, THEN TO APPROPRIATE CONDENSING UNIT SERVING THIS APARTMENT. SEE ROOF LEVEL HVAC PLANS FOR CONDENSING UNIT LOCATIONS AND DESIGNATIONS. REFRIGERANT LINES SIZED PER MANUFACTURER'S RECOMMENDATIONS. 10 MOUNT RETURN GRILLE HIGH ON WALL TIGHT TO CEILING. 11 TERMINATE OUTDOOR AIR DUCT WITH WALL VENT. CUSTOM COLOR TO BE SELECTED BY ARCHITECT. BASIS OF DESIGN FOR VENT CAP IS DEFLECTO MODEL HSB4W. SEE ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS. 12 5" OUTDOOR AIR DUCT PENETRATES THROUGH FIRE RATED CEILING. PROVIDE FIRE DAMPER AT PENETRATION. TAP INTO TOP OF RETURN DUCTWORK WITH DAMPER. BALANCE AIRFLOW TO 45 CFM. 13 MOUNT RETURN GRILLE LOW ON WALL. RETURN DUCTWORK ROUTES THROUGH THE WALL AND TURNS UP INTO THE BOTTOM OF FCU. TRANSITION AS NECESSARY FOR FINAL CONNECTION. 1/4" = 1'-0" Unit Type B7 Enlarged HVAC Plan1 1/4" = 1'-0" Unit Type B9 Enlarged HVAC Plan2 1/4" = 1'-0" Unit Type B10 Enlarged HVAC Plan3