HomeMy WebLinkAboutH-306 - ENLARGED HVAC PLANSTTT
FD
EF-1
1
1
1
2
12
11
987
10
1
5
1
6
4
3
4
4
2
1
1
G-
24/10
FCU-3
2
SG 12/6
245
SG 12/6
190
SG 12/6
220
SG 6/6
50
SG 12/6
50
SG 12/6
120
SG 6/6
50
24/16 G975
16/125"ø
7"ø
6ø
6ø
4ø
6ø
6ø
7"ø
5"ø7"ø
7"ø
7"ø
DBF-1
G-
24/10
6
EF-1
EF-1
FD
FD
2
12
2
1
1
1
1
1
1
1
3
4
4
6
11
5
10
7
8
9
G 24/16
975
16/127"ø
7"ø
5"ø
7"ø
7"ø
5"ø
7"ø
6ø
4ø
6ø
SG 12/6
50
SG 6/6
50
SG 12/6
225
SG 12/6
200
SG 12/6
235
SG 6/6
50
EF-1
EF-1
G -
24/10
12/6 SG165
DBF-1
G-
24/10 6
FCU-3FD
2
2
1
1
3
8 97
10
6
5
4
4
1
1
1
1
2
FCU-2
DBF-1
G-
24/10
24/12 G675
12/1214/10EF-1
EF-1
12/6 SG150
6/6 SG50
6/6 SG50
12/6 SG135
12/6 SG145
12/6 SG145
7"ø
7"ø
7"ø
7"ø
5"ø
5"ø
6ø
6ø
4ø
FD
G-
24/10
6
11700201
No.
STATE OFJOSEPHR.BO
L
Y
ARDPROFES
S ION A L E N G INEERLICENSE EXPIRES 07/31/22
DATE SIGNED 11/24/21
R E G I S TER
E
D
I
ND I A N A
19030
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID
PHASE III
H-306
ENLARGED HVAC
PLANS
11/24/2111/24/21
RWEH
1/4" = 1'-0"
Unit Type C2.1 Enlarged HVAC Plan3
1/4" = 1'-0"
Unit Type C1.1 Enlarged HVAC Plan2
1/4" = 1'-0"
Unit Type B3.1 Enlarged HVAC Plan1
SHEET PLAN NOTES
1 FURNISH AND INSTALL CEILING RADIATION DAMPER AT ALL LOCATIONS
WHERE GRILLES PENETRATE A FIRE RATED CEILING.
2 TERMINATE EXHAUST DUCT WITH WALL VENT. CUSTOM COLOR TO BE
SELECTED BY ARCHITECT. BASIS OF DESIGN FOR VENT CAP IS DEFLECTO
MODEL HSB4W. SEE ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS.
3 FURNISH AND INSTALL DRYER BOX PER MANUFACTURER'S INSTRUCTIONS.
MOUNT BOTTOM OF DRYER BOX AT NOMINAL 6" ABOVE FINISHED FLOOR FOR
STANDARD DRYERS AND COORDINATE INSTALLATION HEIGHT FOR
STACKABLE DRYERS. SEAL AROUND BOX PERIMETER. INSTALL LABEL
SHOWING EQUIVALENT LENGTH OF INSTALLED DRYER VENT (INCLUDING
NUMBER OF ELBOWS) PER MECHANICAL CODE.
4 FURNISH AND INSTALL BATHROOM EXHAUST FAN EF-1 IN WALL. USE ONLY
SMOOTH RADIUS ELBOWS (R/D = 1.5). MAINTAIN 4"ø DUCTWORK IN WALL
THROUGH ELBOW. FLAIR OUT TO 6"ø DUCT ABOVE CEILING.
5 FURNISH AND INSTALL 7 DAY PROGRAMMABLE THERMOSTAT WITH THE TOP
48" ABOVE FINISHED FLOOR.
6 FURNISH AND INSTALL TRANSFER GRILLE 6" ABOVE TOP OF DOOR.
SHEETMETAL TO BE INSTALLED THROUGH THE WALL. PAINT ANY STUDS THAT
INTERSECT BLACK.
7 PROVIDE FLEXIBLE CONNECTION TO FCU DISCHARGE BEFORE CONNECTION
TO SUPPLY DUCTWORK. FURNISH AND INSTALL FIRE DAMPER WHERE DUCT
PENETRATES RATED CEILING PARTITION.
8 PROVIDE TRAPPED 3/4" CPVC CONDENSATE DRAIN LINE AND TERMINATE
ABOVE HUB-DRAIN LOCATED IN MECHANICAL CLOSET. DO NOT BLOCK FILTER
ACCESS.
9 ROUTE REFRIGERANT LINES UP TO ABOVE CEILING AND OVER TO FURRED
OUT WALL. ROUTE UP TO ROOF, THEN TO APPROPRIATE CONDENSING UNIT
SERVING THIS APARTMENT. SEE ROOF LEVEL HVAC PLANS FOR CONDENSING
UNIT LOCATIONS AND DESIGNATIONS. REFRIGERANT LINES SIZED PER
MANUFACTURER'S RECOMMENDATIONS.
10 MOUNT RETURN GRILLE HIGH ON WALL TIGHT TO CEILING.
11 6" OUTDOOR AIR DUCT PENETRATES THROUGH FIRE RATED CEILING.
PROVIDE FIRE DAMPER AT PENETRATION. TAP INTO SIDE OF RETURN
DUCTWORK WITH DAMPER. BALANCE AIRFLOW TO 60 CFM.
12 TERMINATE OUTDOOR AIR DUCT WITH WALL VENT. CUSTOM COLOR TO BE
SELECTED BY ARCHITECT. BASIS OF DESIGN FOR VENT CAP IS DEFLECTO
MODEL HSB4W. SEE ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS.