HomeMy WebLinkAboutH-601 - HVAC DETAILS AND SECTIONSDRYER BOX TO BE RECESSED INSIDE WALL 4-INCH ROUND DRYER CONNECTION WALL -SEE ARCHITECTURAL PLANS EXHAUST DUCT - MOUNT TO DRYER WALL VENT ACCORDING TO MANUFACTURERS RECOMMENDATIONS DRYER WALL VENT -MODEL #DWV4. COLOR TO BE SELECTED BY ARCHITECT DAMPER WITH MAGNETS FASTEN FIRE DAMPER FRAME TO SLEEVE AS REQUIRED BY U.L. LABEL DUCT CONNECTOR-FULL WIDTH OF SLEEVE REQUIRED AT TOP ONLY 'S'-SLIP TYPICAL CONNECTION TO DUCTWORK 160°F FUSIBLE LINK CONNECT DUCT TO DAMPER COLLAR BOTH SIDES OF PARTITION AS REQUIRED BY U.L. LABEL ANGLES 1 1/2"x1 1/2"x1/8" MINIMUM; FASTENED TO SLEEVE AS REQUIRED BY U.L. LABEL; ANGLES TO LAP MASONRY OPENING MINIMUM 1" FIRE RATED FLOOR OR PARTITION TOP BLADE RIVETED TO FRAME WALL SLEEVE; MINIMUM 16 GA. FOR DAMPERS NOT EXCEEDING 36"Wx24"H AND 14 GAUGE FOR LARGER SIZES NOTE: PROVIDE HINGED OR DOUBLE CATCH ACCESS DOOR SIZED AND LOCATED TO PERMIT REPLACEMENT OF FUSIBLE LINK LABELED "FIRE DAMPER ACCESS" DUCT CONNECTOR-FULL WIDTH OF SLEEVE REQUIRED AT TOP ONLY ROOF MEMBRANE PIPE INSULATION BASE GALVANIZED CHANNEL SECURE PIPING TO SUPPORT WITH STRAP 1' - 4" 3' - 0"0' - 8"0' - 4"SEAL CAVITY WITH MINERAL WOOL INSULATION. REFRIGERANT PIPING TO CONDENSING UNITS ON EACH SIDE. POWER WIRING AND REFRIGERANT PIPING FROM BUILDING UP THROUGH ROOF IN CUSTOM SHEET METAL ENCLOSURE. FILL CAVITY WITH INSULATION.3' - 0"1' - 6"ATTACH TO WOOD NAILER EVERY 3" AIR HANDLING UNIT AHU DRAIN CONDENSATE DRAIN PIPE WITH INSULATION 1 1/2" INSULATION BY UNIT MANUF. L3x3x1/4 CONTINOUS (TYP EACH SIDE) CUT OPENINGS IN EXISTING ROOF AND DECK. ROOF CURB TO SIT ON EXISTING STRUCTURAL STEEL. SECURE AS REQUIRED SECURE ROOF CURB TO EXISTING STRUCTURE EXISTING ROOF SYSTEM ROOF FIELD APPLIED CANT CONDENSATE DRAIN THROUGH ROOF CURB COUNTER FLASHING ROOF CURB BY UNIT MANUFACTURER CURB RAIL BY UNIT MANUFACTURER GASKET BY UNIT MANUFACTURER EXISTING STRUCTURE8" MIN.MOTOR DISCONNECT SWITCH BY UNIT MFGR. PIGTAIL CORD EXTERNAL ALUM. WIRE POST BY UNIT MFGR. REFER TO ARCHITECTURAL PLANS FOR ROOF CONSTRUCTION AUTO BACKDRAFT DAMPER SEE PLANS FOR DUCT SIZE ALUM. HOUSING FAN WHEEL BIRDSCREEN FLASH AND COUNTERFLAS H 16" HIGH PRE-FAB CURB PROVIDE HOLE THRU ROOF ROUTE WIRE OUTSIDE DAMPER, BY OTHERS ROOF CURB CAP 40" MIN.36" MIN. DOOR MIN. 30" WATER HEATER PAN WATER HEATER FAN COIL UNIT PLENUM CLEARANCE RACK REFRIGERANT LINE SETS ON SIDE WALL OF MECH ROOM RETURN GRILLE, SEE PLANS CONDENSATE DRAIN; ROUTE TO HUB DRAIN MAIN SHUT-OFF WATER HEATER PAN SLEEVE FLEX CONN. DUCTFIRE DAMPER W/ACCESS PANEL FAN COIL UNIT WATER HEATER HW CW VALVE (TYP.) SIDE VIEW TOP VIEW NOTE: TYPICAL CONDITION SHOWN, REFER TO HVAC AND PLUMBING FLOOR PLANS FOR ADDITIONAL REQUIREMENTS. CEILING RADIATION DAMPER PLENUM BOX OR ELBOW, R/D=1.5 MIN. 20"9'-0" REFER TO PLANSSEE HVACPLANSSEE HVAC PLANS12"MIN.NOM.36"FIRE PARTITION BY CONTRACTOR; WITH FOAM SEAL.4"NOTES: 1. ROUTE CONDENSATE PIPING (SIZE PER MANUFACTURER) TO HUB DRAIN. 2. REFER TO REFRIGERANT PIPING DETAIL ON HVAC DETAIL SHEET FOR ASSOCIATED REQUIREMENTS. 3. REFER TO STRUCTURAL UNIT PLAN DRAWINGS FOR ACTUAL CONDITION AT EACH CLOSET. HARD DUCT MAIN ALWAYS ROUTES PARALLEL TO JOINTS. 4. COORDINATE HARD DUCT ELEVATION AT JOIST SPACE WITH FIRE AND PLUMBING PIPING PRIOR TO INSTALLATION. 5. FIRESTOP ALL PENETRATIONS AT CEILING, FLOOR AND THROUGH FCU SUPPORT. NOM. 30" T&P VALVE, ROUTE DRAIN LINE TO HUB DRAIN 4" HUB DRAIN 2" WASTE 11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFES S ION A L E N G INEERLICENSE EXPIRES 07/31/22 DATE SIGNED 11/24/21 R E G I S TER E D I ND I A N A 19030 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID PHASE III H-601 HVAC DETAILS AND SECTIONS 11/24/2111/24/21 RWEH NOT TO SCALE Dryer Box DetailA NOT TO SCALE Exhaust Vent Cap DetailB NOT TO SCALE Fire Damper Installation DetailC NOT TO SCALE Pipe Roof Support DetailD NOT TO SCALE Roof Penetration DetailE NOT TO SCALE Rooftop Air Handling Unit Drain DetailF NOT TO SCALE Typical Exhaust Fan (Flat) DetailG NOT TO SCALE APT. WATER HEATER & FAN COIL UNIT DETAILH