Loading...
HomeMy WebLinkAboutLS103 Floor Plan & SectionsProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032750 Veteran's WayPEDCOR DESIGN GROUP LLC Floor Plan & Sections THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS 11/26/2019 L S103For Reference OnlyFor Reference OnlyRevision ID Transmittal Set Date Transmittal Set Name 01 7/14/20 Steel Release 1 1 2 2 A B A B BIMcloud: pedcordesign - BIMcloud as a Service/Wren - Building J/Building J Wren - Monday, August 30, 2021+18' 2 3rd Floor +28'-8" 3 4th Floor +39'-4" 4 5th Floor +50' 5 6th Floor / Roof 1 HR LOAD BEARING WALL (WHEN SUPPORTING FLOOR OR ROOF) UL:P550 UL:G564 UL:D902 UL:P550UL:P550 UL:G564 UL:G564 UL:G564 UL:G564 UL:G564 UL:D902 UL:D902 UL:D902 UL:D902 UL:D902 NOTE: UL:D902 - REFER TO AF SHEETS FOR COMPLETE SFRM INFORMATION UL:#### +18' 2 3rd Floor +28'-8" 3 4th Floor +39'-4" 4 5th Floor +50' 5 6th Floor / Roof 1 HR LOAD BEARING WALL (WHEN SUPPORTING FLOOR OR ROOF) UL:P550 UL:G564 UL:D902 UL:G564 UL:D902 NOTE: UL:D902 - REFER TO AF SHEETS FOR COMPLETE SFRM INFORMATION UL:G564 UL:#### UL:#### WALL TYPES-FIRE RATINGS 1 HOUR RATED 2 HOUR RATED DRAFT STOP EXITS AND LOCATIONS BE BUILDING EXIT OP FEC FIRE EXTINGUISHER CABINET 1 HOUR RATED LOAD BEARING WALL 2 HOUR RATED LOAD BEARING WALL 20 MINUTE DOOR 45 MINUTE DOOR 60 MINUTE DOOR 90 MINUTE DOOR EMERGENCY LIGHTING - (NOTE: ELECTRICAL DRAWINGS INDICATE ACTUAL LOCATIONS AND BACKUP ENERGY SOURCE.) EXIT PATH WITH ORIGINATION POINT & TRAVEL DISTANCE RATED ASSEMBLY NUMBER AND RELEVANT BUILDING CODE SECTION ALLOWABLE WALL OPENINGS AND RELEVANT BUILDING CODE SECTION ROOM NAME DESIGNATION ROOM NUMBER AREA OF SPACE WORST CASE OCCUPANT LOAD OCCUPANCIES CONSIDERED TD=123' 3 HOUR RATED 180 MINUTE DOOR TE TENANT EXIT WORST CASE OCCUPANCY TYPE RAG FIRE ALARM ANNUNCIATOR (REMOTE AND GRAPHIC) COMMERCIAL TENANT 101 2,080 SF UL___ IBC 602 Not Permited IBC 705.8 Occupancy:153 A-2, A-3, B or M Assembly x22 x21.9 x21.5 x21.4 x21.1 x21 x19 x18.1 x18 x16 x15 x14 13.9 1.7 x13 x12x1721.2 +18' 2 3rd Floor +28'-8" 3 4th Floor +39'-4" 4 5th Floor +50' 5 6th Floor / Roof 1 HR LOAD BEARING WALL (WHEN SUPPORTING FLOOR OR ROOF) UL:P550 UL:G564 UL:D902 UL:G564 UL:D902 NOTE: UL:D902 - REFER TO AF SHEETS FOR COMPLETE SFRM INFORMATION UL:P550 UL:G564 UL:D902 UL:G564 UL:D902 UL:G564 UL:#### xF 32 xF.9 xG xG.5 xH.5 xJ xJ.3 xJ.5F.10 +18' 2 3rd Floor +28'-8" 3 4th Floor +39'-4" 4 5th Floor +50' 5 6th Floor / Roof 1 HR LOAD BEARING WALL (WHEN SUPPORTING FLOOR OR ROOF)1 HR LOAD BEARING WALL (WHEN SUPPORTING FLOOR OR ROOF) B2/A004 A2/A004UL:P550 UL:G564 UL:D902 UL:G564 UL:D902 NOTE: UL:D902 - REFER TO AF SHEETS FOR COMPLETE SFRM INFORMATION UL:G564 UL:P550 UL:G564 UL:D902 UL:G564 UL:D902 UL:G564 UL:P550 UL:G564 UL:D902 UL:G564 UL:D902 UL:P550 UL:G564 UL:D902 UL:G564 UL:P550 UL:G564 UL:D902 UL:G564 UL:P550 UL:G564 UL:D902 UL:G564 UL:P550 UL:G564 UL:D902 UL:G564 UL:P550 UL:G564 UL:D902 UL:G564 UL:P550 UL:G564 UL:D902 UL:G564 UL:P550 UL:G564 UL:D902 UL:G564 UL:P550 UL:G564 UL:D902 UL:G564 UL:D902 xF.9 xG xG.5 xH.5 xJ xJ.3 xJ.5F.10 xF.9 xG xG.5 xH.5 xJ xJ.3 xJ.5F.10 SCALE: 3/32" = 1'-0" B1 LIfe Safety Building Section LS103 0 8'16'24' SCALE: 1:170.67 C2 Life Safety Building Section LS103 SCALE: 1:1.67 Life Safety Legend LS103 SCALE: 1:170.67 B2 Life Safety Building Section LS103 SCALE: 3/32" = 1'-0" A1 Life Safety Building Section LS103 0 8'16'24'