Loading...
HomeMy WebLinkAboutP-101A - 1ST FLOOR PLUMBING PLAN - AREA AM H.9 H.9 xJ xJ x17x17 xJ.5 xJ.5 x16.9x16.9 x18x18 x18.1x18.1 x19x19 x20x20 x21x21 x21.1x21.1 xJ.1 xJ.1 xJ.2 xJ.2 xJ.3 xJ.3 x21.4x21.4 x21.5x21.5 x21.9x21.9 x22x22 xH.5 xH.5 xH xH xG.5 xG.5 xG xG xF.9 xF.9 20.7 20.7 19.7 19.7 19.4 19.4 F.4 F.4 F.8 F.8 G.1 G.1 G.8 G.8 G.9 G.9 H.3 H.3 H.4 H.4 H.6 H.6 XJ.4 XJ.4 20.5 20.5 19.5 19.5 F.10 F.10 H.2 H.2 21.2 21.2 2 1 6" WASTE INV. EL.= +0'-6" A.F.F. SEE SITE/CIVIL DRAWINGS FOR CONTINUATION 10" STORM INV. EL.= +0'-6" A.F.F. 3 WATER METER INCOMING 4" DOMESTIC WATER INCOMING 6" FIRE WATER 4" HOUSEKEEPING PAD FCO 4" CW 4" CW W WWWDWBP-1 ET-2 BFP-2 BFP-1 3"HD-2 HB-1 4" CW 4" CW 3/4" CW WH-1 F 12 11 20 ST 6" ST 6" ST10" ST CO 10 10 8 9 ST ST8" ST 8" ST STST4 8 WH-1 6 7 6 7 10" ST W ST 13 3" PD 4" CW 1111 4"FD-2 4"FD-2 4"FD-2 15 5 4" ST 4" ST STCOST 16 16 16 3" V 3" V 6" W 6" W 6" W 6" W 6" W 6" W 4" CW 3/4" CW 17 PD18 SE-1 2" V 2" V 19 19 21 21 21 21 21 22 22 FCO FCO FCO FCO CO GENERAL PLUMBING NOTES: A. REFERENCE SHEET M-000 FOR GENERAL PLUMBING SYMBOLS, LEGENDS, ABBREVIATIONS AND ADDITIONAL GENERAL NOTES. NOTE: ALL ABOVE CEILING OR EXPOSED STORM, SANITARY WASTE, VENT AND CW PIPING OFF THE FIRST AND SECOND FLOOR AREA TO BE PROVIDED WITH ZESTON 2000 SERIES INSULATION WITH PVC JACKET AND FITTING COVERS, COLOR GRAY. 11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFES S ION A L E N G INEERLICENSE EXPIRES 07/31/22 DATE SIGNED 11/24/21 R E G I S TER E D I ND I A N A 19030 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID PHASE III P-101A 1ST FLOOR PLUMBING PLAN - AREA A 09/17/1909/17/19 GRJK N 0 16'8'4'1/8" = 1'-0" 1ST FLOOR PLUMBING PLAN - AREA A1 SHEET PLAN NOTES 1 6"W DROP AND CONNECT TO EXISTING 6"W STUB. 2 10"ST DROP AND CONNECT TO EXISTING 10"ST STUB. 3 4'-0" DIA x 9'-0" TALL FIBERGLASS SANITARY BASIN WITH GAS TIGHT COVER ON 6" TALL CONCRETE PAD. 4 8"ST UP. 5 4"ST UP. 6 4" VENT UP. 7 4" VENT CAP FOR FUTURE USE. 8 6"W UP. 9 4"CW UP. 10 3"CW VALVE AND CAP FOR FUTURE USE. 11 3/4"CW DROP. 12 FIRE PROTECTION DESIGN, CALCULATIONS AND INSTALLATION TO BE PROVIDED BY FIRE PROTECTION CONTRACTOR. 13 3"V AND 4"SG FROM BELOW FLOOR SLAB IN CORNER. EXTEND 4"SG PIPE TO 9'-0" A.F.F. AND CAP FOR FUTURE USE. 15 WALL PIV BY FIRE PROTECTION CONTRACTOR. VERIFY PIV TYPE AND EXACT LOCATION WITH FIRE PROTECTION CONTRACTOR. 16 4"W CAPPED FOR FUTURE USE. 17 3"PD RISE, 2"V RISE. 18 SEWAGE EJECTOR CONTROLLER. 19 2"V FROM BELOW. 20 6"ST UP. 21 CONNECT 4" STORM DRAIN LINE TO EXPANSION GUTTER, DROP AND TERMINATE 12" ABOVE FINISH GRADE OR SURFACE. 22 INSTALL PIPE AS HIGH AS POSSIBLE. 11/24/21 BUILDING SHELL BID PHASE III