HomeMy WebLinkAboutP-102B - 2ND FLOOR PLUMBING PLAN - AREA Bx16x16
H.9
H.9
xJ
xJ
x17x17
xJ.5
xJ.5
x16.9x16.9
xJ.1
xJ.1
xJ.2
xJ.2
xJ.3
xJ.3
xH.5
xH.5
xH
xH
xG.5
xG.5
xG
xG
xF.9
xF.9
x15x15
x14x14
1.71.7
x13x13
x12x12
13.913.9
F.8
F.8 G.1
G.1
G.8
G.8
G.9
G.9
H.3
H.3
H.4
H.4 H.6
H.6 XJ.4
XJ.4
14.9 14.9
13.1 13.1
12.212.2
11.511.5 WW
W
W
3" ST 3" ST3" ST 3" ST
3" ST
ST STST ST
CO
3" STCO
2 2
67
4
12
9
2
3" ST
3" ST STST
CO
21
9
2
CO
3" ST
3" ST
ST ST4
23
14
9
9
9
9
8
14
4" V
6" ST 3
10
23
ST
7ST3" ST
3" ST
2
6
3" ST
ST2
6
9
9
1
4" W
9
11
11
23
9
SEE 1/ P-301 FOR
ENLARGED PLAN
SEE 1/ P-303 FOR
ENLARGED PLAN
SEE 1/ P-305 FOR
ENLARGED PLAN
SEE 2/ P-305 FOR
ENLARGED PLAN
SEE 2/ P-301 FOR
ENLARGED PLAN
SEE 1/ P-302 FOR
ENLARGED PLAN
SEE 2/ P-302 FOR
ENLARGED PLAN
SEE 3/ P-302 FOR
ENLARGED PLAN
SEE 3/ P-304 FOR
ENLARGED PLAN
SEE 5/ P-305 FOR
ENLARGED PLAN
SEE 4/ P-302 FOR
ENLARGED PLAN
3" ST
6" ST ST9
13
4" ST
6" ST
4" ST
4" ST
ST STCOST5
5
11
9
13
11
11
9
13
9
14
9
9
13
9
13
9
9
14
19
14
W
W
W
W
WWCO
2" CW
2 1/2" CW
2 1/2" CW
2" CW
2" CW
2" CW
2 1/2" CW
3" CW
3" CW
15
1 1/2" CW
2" CW
3" CW
1 1/2" CW
1 1/2" CW
3" CW
3" CW
1 1/2" CW
4" CW
1 1/2" CW
4" CW
4" W
4" W
3" W
4" W 4" W
4" W 4" W
4" W
4" W
3" W
4" W
4" W
16
16
16
17
13
18
2" W
16
3" ST
3" ST
3" ST
3" ST
3" ST
3" ST
ST
8
2" CW
3" CW
3" CW
8
8
8
8
20
4" V
4" V
4" W
3" W
3" V
4" V
22 22
4" W
4" V
3" V
3" WCO
22
4" W
4" V 8
22
4" W 3" W
4" W
4" V
3" W
3" V
4" W
4" V
CO
CO
CO
22
W4" V
4" W
WW
W
22
8
4" W
4" V
4" V
4" W
W8
22
4" W
4" W
4" W
4" V
4" V8
8
CO
CO
W
W
CO
WCO
4" W
4" W
4" V
4" W
8
22
24
3" V
12 12
12
12
2 1/2" CW
3" CW
GENERAL PLUMBING NOTES:
A. REFERENCE SHEET M-000 FOR GENERAL PLUMBING SYMBOLS, LEGENDS,
ABBREVIATIONS AND ADDITIONAL GENERAL NOTES.
NOTE:
ALL ABOVE CEILING OR EXPOSED STORM, SANITARY WASTE, VENT AND CW
PIPING OFF THE FIRST AND SECOND FLOOR AREA TO BE PROVIDED WITH ZESTON
2000 SERIES INSULATION WITH PVC JACKET AND FITTING COVERS, COLOR GRAY.
11700201
No.
STATE OFJOSEPHR.BO
L
Y
ARDPROFES
S ION A L E N G INEERLICENSE EXPIRES 07/31/22
DATE SIGNED 11/24/21
R E G I S TER
E
D
I
ND I A N A
19030
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID
PHASE III
P-102B
2ND FLOOR PLUMBING
PLAN - AREA B
09/17/1909/17/19
GRJK
1/8" = 1'-0"
2ND FLOOR PLUMBING PLAN - AREA B1016'8'4'
N
SHEET PLAN NOTES
1 6"ST UP.
2 3"ST UP TO DECK DRAIN (DD-1).
3 6"ST DOWN.
4 6"ST UP AND DOWN.
5 4"ST UP.
6 4"V FROM BELOW. 4"V RISE.
7 4"V CAPPED FOR FUTURE USE.
8 4" VENT STACK UP.
9 4" WASTE STACK UP.
10 6"W DOWN.
11 1 1/2"CW RISER UP.
12 2 1/2"CW VALVE AND CAP FOR FUTURE USE.
13 3" WASTE/VENT STACK UP.
14 2"CW RISER UP.
15 3"CW DOWN.
16 3"ST UP.
17 3/4"CW UP.
18 2"W WITH P-TRAP UP TO FLOOR DRAIN.
19 2"CW RISER UP.
20 4"W CAPPED FOR FUTURE USE.
21 6"W DOWN, 4"V RISE.
22 4"W DOWN.
23 3"CW VALVE AND CAP FOR FUTURE USE.
24 3" WASTE/VENT STACK DOWN.
11/24/21 BUILDING SHELL
BID PHASE III