HomeMy WebLinkAboutP-301 - PLUMBING ENLARGED PLANSGENERAL SHEET NOTES:
A. REFERENCE SHEET M-000 FOR GENERAL PLUMBING SYMBOLS, LEGENDS,
ABBREVIATIONS AND ADDITIONAL GENERAL NOTES.
B. ALL DOMESTIC WATER PIPING (COLD & HOT) IN UNIT TO BE 1/2" SIZE UNLESS
NOTED OR SHOWN OTHERWISE.
C. ALL WASTE PIPING IN UNIT TO BE 2" SIZE UNLESS NOTED OR SHOWN
OTHERWISE.
D. ALL VENT PIPING IN UNIT TO BE 1 1/2" SIZE UNLESS NOTED OR SHOWN
OTHERWISE.
ET-1
DWH-2
VB-1
12
13
15
5
3
7
6
8
13
12
3
4
WVB-1
1
2
10
5 9
SK-2
WD-1
L-1
WC-1
TS-1
WB-1
WMDP-1
2"HD-1
3" W
3" W
3" W
1 1/2" V
2" W
3" W
2" W 1 1/2" V
WW WCO
1" CW
3/4" HW
3/4" CW
3/4" HW3/4" CW
DWH-2
12
13
15
5
3
7
6
8
1312
3
4
1
2
10
5 11
VB-1
SK-2
WD-1
WB-1
WMDP-1
2"HD-1
ET-1
WVB-1
TS-1
L-1
WC-1
3" W
3" W 2" W
3" W
2" W
1 1/2" V
1 1/2" V
3" W
W
WCO
1" CW
3/4" CW
3/4" HW
3/4" CW 3/4" HW
DWH-1
TS-1
WC-1
L-1
L-1
WVB-1
ET-1
2"HD-1
VB-1
WD-1 SK-2
WB-1
WMDP-1
15 5
3
7
6
8
13
12
3
4
1
2
10
5 9
142" W
3" W
3" W
3" W
3" W
1 1/2" V
1 1/2" V
3" W
W
WW
3/4" HW
1" CW
3/4" CW
3/4" CW
3/4" HW
DWH-1 ET-1
WVB-1
WB-1
WMDP-1
TS-1
L-1
WC-1
WD-1
SK-2
VB-1
2"HD-1
155
3
7
68
13
12
3 4
1
2
10
59
3" W
3" W
3" W
1 1/2" V
3" W
3" W
CO
1 1/2" V
1" CW
3/4" CW
3/4" HW
3/4" CW
3/4" HW
DWH-2
L-1 L-1
WC-1 TS-1
WB-1
WMDP-1
ET-1
2"HD-1
WVB-1
WD-1
VB-1
SK-2
15
5
3
7
6
8 131234
1 2
10
5 9
14
3" W
3" W
3" W
3" W
WW
1 1/2" V
1 1/2" V
2" WW1" CW
3/4" HW
3/4" CW
3/4" CW
3/4" HW
3/4" CW
3/4" HW
DWH-1
WD-1
SK-2
VB-1
WVB-1
2"HD-1
WB-1
WMDP-1
TS-1WC-1
L-1L-1
ET-1
15
5
3
7
6
8 131234
1 2
10
5 9
14
3" W
3" W
3" W
3" W
1 1/2" V
1 1/2" VW WW W2" W
1" CW
3/4" CW
3/4" HW
3/4" CW
3/4" HW
3/4" HW
3/4" CW
11700201
No.
STATE OFJOSEPHR.BO
L
Y
ARDPROFES
S ION A L E N G INEERLICENSE EXPIRES 07/31/22
DATE SIGNED 11/24/21
R E G I S TER
E
D
I
ND I A N A
19030
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID
PHASE III
P-301
PLUMBING ENLARGED
PLANS
11/07/1911/07/19
GRJK
SHEET PLAN NOTES
1 INCOMING COLD WATER RISER TO UNIT WVB-1.
2 INCOMING CW RISE.
3 1/2"CW DROP.
4 1/2"CW & 1/2"HW DROP. 1 1/2"V RISE. 2"W DOWN
5 1/2"CW & 1/2"HW DROP.
6 1/2"CW & 1/2"HW DROP. ROUTE 1/2"CW & 1/2"HW INSIDE WALL BELOW
COUNTERTOP TO SINK.
7 2"W DOWN. 1 1/2"V RISE TO AIR ADMITTANCE VALVE (AAV) LOCATED AS HIGH
AS POSSIBLE IN CABINET.
8 3"W UP TO WATER CLOSET.
9 2"W WITH P-TRAP UP TO TUB SHOWER.
10 2"W WITH P-TRAP UP TO HUB DRAIN.
11 2"W WITH P-TRAP UP TO SHOWER DRAIN.
12 4" VENT STACK.
13 4" WASTE STACK
14 3" WASTE/VENT STACK.
15 1 1/2"V RISE. 2"W DOWN.
1/4" = 1'-0"
UNIT 'A1' PLUMBING PLAN1
1/4" = 1'-0"
UNIT 'A2' PLUMBING PLAN2
1/4" = 1'-0"
UNIT 'A3' PLUMBING PLAN3
1/4" = 1'-0"
UNIT 'A4' PLUMBING PLAN4
1/4" = 1'-0"
UNIT 'A5' PLUMBING PLAN5
1/4" = 1'-0"
UNIT 'A6' PLUMBING PLAN6
0 8'4'2'
0 8'4'2'
0 8'4'2'
0 8'4'2'
0 8'4'2'0 8'4'2'
11/24/21 BUILDING SHELL
BID PHASE III