Loading...
HomeMy WebLinkAboutA502-WINDOW-ELEVATIONS-Rev.0W2 W3W1 W4 W5 W6 W7 W8 W9 W10 W11 BL1 BL2 BL3 BL42"2' - 0" 2" 3' - 6" 2"3' - 4" 6' - 0"6' - 0" 2"1' - 9" 2" 3' - 9" 2" 4" 6' - 8" 2" 2' - 0" 2"9' - 4"2" 5' - 3" 2" 2' - 11" 2" 8' - 8"4" 2' - 0" 2" 4' - 6" 2" 4' - 0" 2"2"4' - 3" 2" 8' - 11" 2" 13' - 8"11' - 4"2" 9' - 11" 2" 4' - 11" 2" 4" 6' - 8" 2" 4' - 0" 2"11' - 4"15' - 4" 20' - 0"11' - 4"2" 6' - 4" 2" 6' - 8" 2" 6' - 4" 2"4" 2' - 0" 2" 4' - 6" 2" 4' - 0" 2"RUN JAMBS TO FINISHED FLOOR AND ANCHOR AS DOOR JAMBS.6' - 0" 2" 10" 2"2' - 0" 2" 2"1' - 9" 2" 3' - 9" 2"3' - 4"6' - 0" W6 ACOUSTIC WINDOWS TO BE ST. CLOUD 960-A7 WITH GLAZING OPTION 5. STC 54 OTIC 43 2"2' - 8" 2"18' - 2" 2" 6' - 0" 2" 6' - 0" 2" 6' - 0" 2" 6' - 0" 2" 6' - 0" 2" 31' - 0"3' - 0"3' - 0"2" 5' - 1" 2" 6' - 0" 2" 6' - 0" 2" 6' - 0" 2" 6' - 0" 2" 6' - 0" 2" 6' - 0" 2" 6' - 0" 2" 6' - 0" 2" 5' - 1"2"2' - 8" 2"18' - 2" 4" 2' - 0" 2" 4' - 6" 2" 4' - 0" 2"2" 1' - 9" 2"3' - 9" 2" 6' - 0"11' - 4"4" 5' - 4" 2" 5' - 4" 2"11' - 4"2" 2' - 4" 2" 2' - 8"2"14' - 8 1/4" 2" 2' - 8" 2"12' - 8 1/4" 2" 4' - 8" 2"10' - 8 1/4" 2" 6' - 8" 2"8' - 8 1/4" 2" 8' - 8" 2"6' - 8 1/4" 2" 10' - 8" 2" 2' - 4" 2" 2' - 8" 2" 2' - 4" 2" 2' - 8" 2" 2' - 4" 2" 2' - 8" 2" 2' - 4" 2" 2' - 8" 2" 2' - 4" 2" 2' - 8" 2' - 8" 2' - 8" 2' - 8" 2' - 8" 2' - 8" 2' - 8" 2' - 8" 2' - 8"2" 4' - 0" 2"7' - 0" 4' - 4"2" 3' - 8" 2" 4' - 0" 2" 4' - 9" 2" 4' - 9" 2" 10' - 0"2"4' - 0" 2"7' - 0" 4' - 4"2" 3' - 9" 2" 3' - 9" 2" 8' - 0"2"4' - 0" 2"7' - 0" 4' - 4"GLASS SCHEDULE A. 1" THICK INSULATING LOW-E, 1/4" TEMPERED OUTSIDE, 1/2" AIRSPACE, 1/4" TEMPERED INSIDE. B. 1/4" CLEAR TEMPERED GLASS. C. 1/4" LAMINATED CLEAR GLASS. D. REUSED STAINED GLASS WINDOW. E. FIRE-RATED CERAMIC GLASS. F. 1" THICK INSULATING LOW-E SPANDREL GLASS, 1/4" TEMPERED OUTSIDE, 1/2" AIRSPACE, 1/4" TEMPERED INSIDE. LOCATION OF OPACIFIER TO BE AS RECOMMENDED BY GLAZING MANUFACTURER. G. INSULATING ACOUSTICAL GLASS. H. 5/8" LAMINATED GLASS (TO ACHIEVE STC 46 DOOR RATING) ABBREVIATIONS LEGEND AL = ALUMINUM AN = ANODIZED BL = BORROWED LITE ETR = EXISTING TO REMAIN GHM = GALVANNEALED HOLLOW METAL GL = GLASS HM = HOLLOW METAL PT = PAINT ST = STAIN SS = STAINLESS STEEL STL = STEEL WD = WOOD 90M = 90 MINUTE ASSEMBLY RATING * = SEE REMARKS COLUMN FOR NOTES GENERAL DOOR NOTES A. THESE GENERAL NOTES APPLY TO THE DOOR SCHEDULE. B. DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE ROOM NUMBER. IN ROOMS WITH MULTIPLE OPENINGS, A NUMERICAL SUFFIX HAS BEEN ADDED TO DOOR NUMBERS. C. VERTICAL FRAMING MEMBERS AT ALL DOOR FRAMES SHALL EXTEND TO STRUCTURE ABOVE. D. UNDERCUT ALL DOORS AS REQUIRED BY FINAL FINISH. E. PROVIDE CONTINUOUS SEALANT BETWEEN HOLLOW METAL FRAME PERIMETERS AND SURROUNDING WALL CONSTRUCTION. F. PROVIDE CONTINUOUS SEALANT BETWEEN INTERIOR AND EXTERIOR WINDOW, CURTAIN WALL AND STOREFRONT FRAME PERIMETERS AND SURROUNDING CONSTRUCTION UNLESS NOTED OTHERWISE. G. GROUT FULL HOLLOW METAL FRAMES IN MASONRY CONSTRUCTION. H. SPOT GROUT HOLLOW METAL FRAMES IN GYPSUM WALLS. I. WHERE A FIRE RATING IS INDICATED ON THE DOOR SCHEDULE, HARDWARE AND DOOR ASSEMBLY COMPONENTS SHALL MEET THE REQUIREMENTS OF THAT LABEL. J. WHERE AN STC RATING IS INDICATED ON THE DOOR SCHEDULE, HARDWARE AND DOOR ASSEMBLY COMPONENTS SHALL MEET THE REQUIREMENTS OF THAT LABEL. K. INSTALL DOOR GLASS USING WET GLAZING METHOD. L. ALL LINTELS ABOVE EXTERIOR OPENINGS SHALL BE GALVANIZED. M. REFER TO SHEET A502 FOR ADDITIONAL DOOR, FRAME AND BORROWED LITE ELEVATIONS. N. COORDINATE THROAT OPENINGS WITH WALL WIDTH FOR ALL WRAP AROUND FRAMES. O. SCHEDULED HARDWARE FOR ALUMINUM DOORS SHALL BE PROVIDED BY HARDWARE SUPPLIER AND INSTALLED BY ALUMINUM SUPPLIER. ALUMINUM DOORS TO BE PREPARED BY ALUMINUM DOOR SUPPLIER IN ACCORDANCE WITH THE SCHEDULED HARDWARE. P. ALL NEW HOLLOW METAL DOORS, FRAMES AND BORROWED LITE FRAMES TO BE PAINTED AS INDICATED ON THE A800 SERIES FINISH PLANS. SEE FINISH PLANS FOR WOOD DOOR FINISHES. Q. PROVIDE SILENCERS ON ALL DOOR FRAMES. R. SEE STRUCTURAL DRAWINGS FOR REQUIREMENTS FOR MASONRY AND STEEL LINTELS. PROVIDE STRUCTURAL STEEL LINTELS AT OPENINGS WHERE INDICATED ON THE STRUCTURAL STEEL DRAWINGS IN LIEU OF MASONRY LINTEL AS SHOWN IN THESE DETAILS. S. VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS IN THE FIELD PRIOR TO FABRICATION OF DOORS AND FRAMES. BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT. T. SEE SPECIFICATION SECTION 08 71 00 FOR DOOR HARDWARE INDEX, SETS AND SPECIFICATIONS DOOR NOTES 1. PROVIDE PANIC HARDWARE. 2. NEW DOOR LEAF (LEAVES) IN EXISTING FRAME (VERIFY SIZE). 3. NOT USED. 4. CARD READER (AND PANIC BAR WHERE INDICATED) WITH EL-OPTION, EPT, AND POWER SUPPLY - SEE HARDWARE SETS - CONFIRM LOCATIONS WITH PARISH. 5. EXTERIOR DOOR AT CHILLER ENCLOSURE. 6. VERIFY EXISTING WALL CONSTRUCTION PRIOR TO FRAME FABRICATION. 7. PROVIDE 4" HEAD AT FRAME. 8. PROVIDE CLOSE SPACED SPRINKLERS IN LIEU OF FIRE RATED DOOR/FRAME ASSEMBLY - SEE DETAILS AND WALL SECTIONS, LIFE SAFETY AND PLUMBING DRAWINGS. 9. PROVIDE SOUND GASKETING, DROP SEAL AS REQUIRED TO ACHIEVE A 46 STC DOOR ASSEMBLY. FILL FRAME WITH MINERAL FIBER BATT INSULATION.2"3' - 4" 2"3' - 4" 2"4' - 2 1/4" 2" 4' - 6 1/4"3' - 8"DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS:PROJECT: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for theproper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BY © 2018 CSO Architects, Inc. All Rights ReservedPARISH LIFE CENTER PROJECTOUR LADY OF MT. CARMEL14598 OAK RIDGE RD, CARMEL, IN 4603209/17/21 NTC CAM 19038 A502 WINDOW ELEVATIONSCATHOLIC CHURCHSCALE: 1/4" = 1'-0" WINDOW ELEVATIONS BORROWED LITE SCHEDULE MARK ELEVATION MATERIAL/FINISH GLASS TYPE HEAD JAMB SILL BL101 BL2 AL/AN C WH6 WJ6 WS6 BL126-1 BL1 AL/AN B WH7 WJ7 WS7 BL126-2 BL3 AL/AN B WH6 WJ6 WS6 BL126-3 BL3 AL/AN B WH6 WJ6 WS6 BL126-4 BL4 AL/AN B WH6 WJ6 WS6 WINDOW SCHEDULE MARK MATERIAL/FINISH GLASS TYPE HEAD JAMB SILL W1 AL/AN A WH1 WJ1 WS1 W2 AL/AN A WH1 WJ1 WS2 W3 AL/AN A WH1 WJ1 WS2 W4 AL/AN A WH1 WJ1 WS2 W5 AL/AN A WH2 WJ2 WS2 W6 AL/AN G WH3 WJ3 WS3 W7 AL/AN A WH4 WJ4 WS4 W8 AL/AN A WH4 WJ4 WS4 W9 AL/AN A WH1 WJ1 WS2 W10 AL/AN D WH5 WJ5 WS5 W11 AL/AN A WH1 WJ1 WS1 12/13/21