HomeMy WebLinkAboutS503-FOUNDATION-SECTIONS-Rev.08" CMU w/ #5 @ 32" O.C. 1' - 2" VENEER PER ARCH'L FINISH GRADE SEE SITE/CIVIL T/WALL EL -1'-4' T/FTG EL PER PLAN #5 @ 12" O.C. EACH WAY EACH FACE FTG SIZE & REINFORCEMENT PER PLAN & SCHEDULE FINISH GRADE SEE SITE/CIVIL A GROUT CMU SOLID BELOW GRADE CONCRETE SLAB ON GRADE PER PLAN T/SLAB EL +0'-0" FOOTING SIZE & REINFORCEMENT PER PLAN & FOOTING SCHEDULE T/FTG EL PER PLAN FINISH GRADE SEE SITE/CIVIL WINDOWS PER ARCH'L 2' - 1" 1' - 6" #4 @ 16" O.C. 24 36 A CONCRETE SLAB ON GRADE PER PLAN T/SLAB EL +0'-0"FINISH GRADE SEE SITE/CIVIL COLD-JOINT WATERSTOP 2' - 1" 1' - 6" T/FTG EL VARIES FOOTING SIZE & REINFORCEMENT PER PLAN & SCHEDULE #6 VERT @ 12" O.C. EACH FACE #5 HORIZ @ 12" O.C. EACH FACE #3 TIES @ 48" O.C. EACH WAY WINDOWS PER ARCH'L #4 @ 12" O.C. 24 36 A CONCRETE SLAB ON GRADE PER PLAN T/SLAB EL PER PLAN FOUNDATION DRAIN PER S401 TYPICAL DETAIL FOOTING SIZE & REINFORCEMENT PER PLAN & SCHEDULE T/FTG EL PER PLAN COLD-JOINT WATERSTOP 2x4 KEYWAY SITE SLAB/FINISH GRADE SEE SITE/CIVIL CONT L5x5x3/8 w/ 5/8" SIMPSON TITEN-HD ANCHOR @ 24" O.C. SLAB ON METAL DECK PER PLAN WALL CONSTRUCTION & VENEER PER ARCH'L 8"2' - 1" 1' - 6" A SLAB ON METAL DECK PER PLAN CONT L5x5x3/8 w/ 5/8" SIMPSON TITEN-HD ANCHOR @ 24" O.C. SLAB ON METAL DECK PER PLAN REF SECTION 4/S503 FOR BALANCE OF WALL INFORMATION WINDOWS PER ARCH'L 2' - 1" SITE SLAB/FINISH GRADE SEE SITE/CIVIL C D CONT L8x6x1/2 w/ 5/8" SIMPSON TITEN-HD ANCHOR @ 16" O.C. T/CONC WALL EL -4'-0" ELEVATOR PIT BASE PER DETAIL 13/S402 CONTRACTOR-DESIGNED SOIL RETENTION SYSTEM T/SLAB EL -4'-1 3/4" 8" CONCRETE WALL w/ #5 @ 12" O.C. EACH WAY T/SLAB EL +0'-0" CONCRETE SLAB ON DECK PER PLAN T/SLAB EL -14'-8" 8" CMU w/ #5 @ 24" O.C. 89 ELEVATOR PIT BASE PER DETAIL 13/S402 CONTRACTOR-DESIGNED SOIL RETENTION SYSTEM T/SLAB EL -14'-8" T/CONC WALL EL -4'-0" 8" CMU w/ #5 @ 24" O.C. T/SLAB EL -4'-1 3/4" 8" CONCRETE WALL w/ #5 @ 12" O.C. EACH WAY8" CONCRETE WALL w/ #5 @ 12" O.C. EACH WAY DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS:PROJECT: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BY © 2018 CSO Architects, Inc. All Rights ReservedPARISH LIFE CENTER PROJECTOUR LADY OF MT. CARMEL14598 OAK RIDGE RD, CARMEL, IN 4603209/17/21 JRO MDL 19038 S503 FOUNDATION SECTIONSCATHOLIC CHURCH1/2" = 1'-0" 1 FOUNDATION SECTION NOTE ALL INFORMATION ON THIS DRAWING IS PROVIDED FOR BIDDING OF ALL STRUCTURAL ELEMENTS EXCEPT STRUCTURAL STEEL AND METAL DECK. ANY INFORMATION SHOWN RELATING TO CONSTRUCTION NOT RELATED TO THIS PACKAGE (I.E. STRUCTURAL STEEL AND METAL DECK) IS SHOWN FOR CONTEXT ONLY AND HAS BEEN COVERED IN A PREVIOUS DRAWING RELEASE. 1/2" = 1'-0"2 FOUNDATION SECTION 1/2" = 1'-0"3 FOUNDATION SECTION 1/2" = 1'-0"4 FOUNDATION SECTION 1/2" = 1'-0"5 FOUNDATION SECTION 1 OWNER COMMENTS 09/23/2021 1/2" = 1'-0" 6 ELEVATOR SECTION 1/2" = 1'-0"7 ELEVATOR SECTION 1 12/13/21