S601-FRAMING-SECTIONS-Rev.0
1 1' - 9" L3x3x1/4 KICKERS AT EACH BEAM CONT L4x4x1/4 ROOF DECK PER PLAN WALL CONSTRUCTION & VENEER PER ARCH'L STEEL BEAMS PER PLAN T/STL EL PER PLAN M 1' - 9" L3x3x1/4 @ 48" O.C. CONT L4x4x1/4 ROOF DECK PER PLAN T/STL EL VARIES WALL CONSTRUCTION & VENEER PER ARCH'L B 1' - 7" 1' - 9" L3x3x1/4 @ 48" O.C. ROOF DECK PER PLAN WALL CONSTRUCTION & VENEER PER ARCH'L CONT L4x4x1/4 ROOF DECK PER PLAN CONT 1/4" BENT PLATE w/ 4" VERTICAL LEG (TYP) CLADDING PER ARCH'L T/STL EL VARIES STEEL BEAMS PER PLAN T/STL EL VARIES 1/4" STIFFENER @ 48" O.C. B 4" ROOF DECK PER PLAN CONT 1/4" BENT PLATE w/ 4" VERTICAL LEG CLADDING PER ARCH'L T/STL EL VARIES ROOF DECK PER PLAN CONT L4x4x1/4 STEEL BEAM PER PLAN T/STL EL VARIES WINDOWS & CLADDING PER ARCH'L 1' - 7" 1/4" STIFFENER @ 48" O.C. 4 8 1/4" T/STL EL PER PLAN T/STL EL VARIES 4" 4 1/2" CONT 3/8"x12" PLATE ROOF DECK PER PLAN STEEL BEAM PER PLAN WALL CONSTRUCTION & VENEER PER ARCH'L CONT 1/4" BENT PLATE w/ 4" VERTICAL LEGROOF DECK PER PLAN STEEL BEAMS PER PLAN 8" A 2' - 1" CONT L5x5x5/16 STEEL BEAMS PER PLAN WALL CONSTRUCTION & VENEER PER ARCH'L ROOF DECK PER PLANT/STL EL PER PLAN L8x6x1/2 x 12" LONG @ 48" O.C. w/ (2) 5/8" SIMPSON TITEN-HD ANCHORS INTO FULLY GROUTED BOND BEAM 10" CMU w/ #6 @ 48" O.C. VERT A.1 CONT 1/2" PLATE 24"-DEEP LONG-SPAN BOND BEAM LINTEL REINFORCE PER S402 TYPICAL DETAIL CONT L8x8x1/2 w/ 5/8" SIMPSON TITEN-HD ANCHOR @ 16" O.C. T/MASONRY OP'NG EL PER ARCH'L 5 5.1 (F.V.) 9 7/8"2" CONT 1/4" BENT PLATE ROOF DECK PER PLAN STEEL EBAMS PER PLAN EXISTING CONSTRUCTION TO REMAIN T/STL EL PER PLAN 1' - 0" 3/4"x6"x11" COLUMN BASE PLATE CONT L4x4x1/44" ROOF DECK PER PLAN HSS STUB COLUMN PER PLAN STEEL BEAMS PER PLAN CONT 1/4" BENT PLATE ROOF DECK PER PLAN T/STL EL PER PLAN J K L (F.V.) 11 1/8" 1' - 5 7/8" WALL CONSTRUCTION & CLADDING PER ARCH'L CONT 1/4" BENT PLATE 1/4" STIFFENER @ 36" O.C. ROOF DECK PER PLANCONT 1/4" BENT PLATE STEEL BEAMS PER PLAN EXISTING CONSTRUCTION TO REMAIN T/STL EL VARIES CONT L4x4x1/4 4" ROOF DECK PER PLAN STEEL BEAM PER PLAN T/STL EL VARIES 2" 7 11 3/4" WALL CONSTRUCTION & CLADDING PER ARCH'L T/STL EL PER PLAN CONT 1/4" BENT PLATE STEEL BEAMS PER PLAN ROOF DECK PER PLAN CONT HSS12x2x1/4 CONT L4x4x1/4 ROOF DECK PER PLAN STEEL BEAM PER PLAN 9 5/8" 11 5/8" ROOF DECK PER PLAN STEEL BEAMS PER PLAN 1/4" STIFFENER @ 48" O.C. CONT 1/4" BENT PLATE WALL CONSTRUCTION & CLADDING PER ARCH'L CONT L5x5x3/8 ROOF DECK PER PLAN CONT HSS12x2x1/4 STEEL BEAMS PER PLAN T/STL EL PER PLAN T/STL EL PER PLAN VERT C5x6.7 @ 48" O.C. WITHIN STUD WALL FRAMING CONT L7x4x3/8 C5x6.7 L3x3x1/4 KICKER L3x3x1/4 @ 48" O.C. L4x4x1/4 @ 48" O.C.CONT L4x4x1/4 STEEL BEAM PER PLAN STEEL BEAM PER PLAN B/MASONRY OP'NG EL PER ARCH'L T/STL EL PER PLAN A.0 1' - 9" VERT C5x6.7 @ 48" O.C. WITHIN STUD WALL FRAMING CONT L7x4x3/8 C5x6.7 L3x3x1/4 KICKER T/MASONRY OP'NG EL PER ARCH'L BEAM-TO-BEAM MOMENT CONNECTION PER S403 TYPICAL DETAILCONT L4x4x1/4 ROOF DECK PER PLAN WALL CONSTRUCTION & VENEER PER ARCH'L STEEL BEAMS PER PLAN 1' - 3" 1' - 8" 19 1' - 8 1/2" VERT C5x6.7 @ 48" O.C. WITHIN STUD WALL FRAMING CONT L7x4x3/8 C5x6.7 L3x3x1/4 KICKER L3x3x1/4 @ 48" O.C. B/MASONRY OP'NG EL PER ARCH'L CONT L4x4x1/4 ROOF DECK PER PLAN WALL CONSTRUCTION & VENEER PER ARCH'L L4x4x1/4 @ 48" O.C. STEEL BEAM PER PLANSTEEL BEAM PER PLAN T/STL EL VARIES 102.5 (F.V.) 7 7/8" EX GLULAM BEAM TO REMAIN NEW STEEL BEAM PER PLAN CONT L4x4x1/4 EX. ROOF TO REMAIN ROOF DECK PER PLAN 3 3/4" 19 1' - 2 1/2" T/STL EL PER PLAN CONT 1/4" BENT PLATE w/ 1/4" VERTICAL LEG ROOF DECK PER PLAN WALL CONSTRUCTION & VENEER PER ARCH'L STEEL BEAMS PER PLAN HSS TUBE GIRT PER PLANT/STL EL PER PLAN CFS OVERBUILD FRAMING @ 48" O.C. MAX ROOF DECK PER PLAN EXISTING ROOF STRUCTURE STEEL EBAMS PER PLAN CONT L5x5x5/16 ROOF DECK PER PLAN7 T/STL EL PER PLAN DECK BRG EL VARIES CONT WT8x13 WITH STEM TAPERED TO MATCH ROOF SLOPE CONT L5x5x5/16 ROOF DECK PER PLAN STEEL BEAMS PER PLAN ROOF DECK PER PLAN 11 1/2" CONT 1/4" BENT PLATE B T/STL EL PER PLAN T/STL EL VARIES CONT L5x5x5/16 10" 2" STEEL BEAMS PER PLAN ROOF DECK PER PLAN ROOF DECK PER PLAN 1/4"x6" BENT PLATE @ 48" O.C. w/ 3/4" BOLT IN VERTICAL SLOTTED HOLES. FINGER TIGHTEN AND FOUL THREADS CONT 1/4" BENT PLATE 8 1/2" A 2' - 1" CONT L5x5x5/16 STEEL BEAMS PER PLAN WALL CONSTRUCTION & VENEER PER ARCH'L ROOF DECK PER PLAN 10" CMU w/ (2) #7 VERT @ 8" O.C. BETWEEN OPENINGS 1' - 4 5/8" T/STL EL PER PLANCONT 1/2" PLATE 20 1' - 6" 11 15/16" WALL CONSTRUCTION & VENEER PER ARCH'L L3x3x1/4 @ 48" O.C. MAX STEEL BEAM PER PLAN ROOF DECK PER PLANCONT L4x4x1/4 T/STL EL PER PLAN L4x4x1/4 @ 48" O.C. MAX B ROOF DECK PER PLAN CONT 1/4" BENT PLATE w/ 4" VERTICAL LEG CLADDING PER ARCH'L T/STL EL VARIES 1' - 7" WALL CONSTRUCTION & VENEER PER ARCH'L 1' - 1" STEEL BEAM PER PLAN CONT L8x4x7/16 CONT L4x4x1/4 ROOF DECK PER PLAN STEEL BEAM PER PLAN 4" 3" 1/4" STIFFENER @ 48" O.C. 19 2' - 0 1/2" 3 3/4" 1' - 8 1/4" CONT L4x4x1/4 SHIM AS R'QD FOR DECK BRG EL CONT L4x4x1/4 STEEL BEAM PER PLAN T/STL EL VARIES T/STL EL PER PLAN L3x3x1/4 @ 48" O.C. ROOF DECK PER PLAN STEEL BEAM PER PLAN 1/2" L4x4x1/4 @ 48" O.C. 103 8 3/8" (F.V.) 10" (F.V.) 1' - 6 3/8" 8" EXISTING HOLLOWCORE PRECAST + 3" TOPPING TO REMAIN (FIELD V'FY) EX. W12 BEAM TO REMAIN NEW STEEL BEAM PER PLAN SLAB EDGE PER S403 TYPICAL DETAIL MATCH EX FLOOR EL. DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS:PROJECT: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BY © 2018 CSO Architects, Inc. All Rights ReservedPARISH LIFE CENTER PROJECTOUR LADY OF MT. CARMEL14598 OAK RIDGE RD, CARMEL, IN 4603209/17/21 JRO MDL 19038 S601 FRAMING SECTIONSCATHOLIC CHURCH3/4" = 1'-0" 1 FRAMING SECTION 3/4" = 1'-0"2 FRAMING SECTION 3/4" = 1'-0" 3 FRAMING SECTION 3/4" = 1'-0"4 FRAMING SECTION 3/4" = 1'-0"5 FRAMING SECTION 3/4" = 1'-0"6 FRAMING SECTION 3/4" = 1'-0"22 FRAMING SECTION 3/4" = 1'-0"8 FRAMING SECTION 3/4" = 1'-0" 9 FRAMING SECTION 3/4" = 1'-0"10 FRAMING SECTION 3/4" = 1'-0" 11 FRAMING SECTION 3/4" = 1'-0"12 FRAMING SECTION 3/4" = 1'-0"15 FRAMING SECTION 3/4" = 1'-0"16 FRAMING SECTION 3/4" = 1'-0"17 FRAMING SECTION 3/4" = 1'-0"18 FRAMING SECTION 3/4" = 1'-0"14 FRAMING SECTION 3/4" = 1'-0"13 FRAMING SECTION 3/4" = 1'-0"19 FRAMING SECTION 3/4" = 1'-0"20 FRAMING SECTION 3/4" = 1'-0" 21 FRAMING SECTION 3/4" = 1'-0"7 FRAMING SECTION 3/4" = 1'-0"23 FRAMING SECTION 3/4" = 1'-0"24 FRAMING SECTION NOTE ALL INFORMATION ON THIS DRAWING IS PROVIDED FOR BIDDING OF ALL STRUCTURAL ELEMENTS EXCEPT STRUCTURAL STEEL AND METAL DECK. ANY INFORMATION SHOWN RELATING TO CONSTRUCTION NOT RELATED TO THIS PACKAGE (I.E. STRUCTURAL STEEL AND METAL DECK) IS SHOWN FOR CONTEXT ONLY AND HAS BEEN COVERED IN A PREVIOUS DRAWING RELEASE. 1 OWNER COMMENTS 09/23/2021 12/13/21