Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A102-GROUND-AND-SANCTUARY-LEVEL-LIFE-SAFETY-PLAN-Rev.0
UP UP 119 SF OFFICE 116 SF IT OFFICE 68 SF RESTROOM 187 SF MULTIPURPOSE / BREAK RM 101 SF OFFICE 101 SF OFFICE 121 SF TECHNOLOGY STORAGE / MDF683 SF WAITING & COFFEE 342 SF ENTRY 101 SF OFFICE 131 SF OFFICE - UNASSIGNED 134 SF OFFICE 121 SF OFFICE 211 SF PRIEST 161 SF ASSOC. PRIEST 161 SF ASSOC. PRIEST 162 SF ASSOC. PRIEST 313 SF CONFERENCE 217 SF WORKROOM 120 SF OFFICE 208 SF RELIGIOUS EDU / PARISH RECEPTION NAVE SACRISTY MECH. PRIVATE HALL RESTROOMHALL JAN. CORRIDOR VESTING CHAIRS STAIR NARTHEX VESTIBULE ENTRY NARTHEX VESTIBULE ENTRY NARTHEX MEN WOMEN PASSAGE BRIDAL RECONCILIATION RECONCILIATION HALL OF AMERICAN SAINTS 174 SF TEMP STAFF/ VOLUNTEERS EXISTING NEW 43 SF RESTROOM 114 SF OFFICE 113 SF OFFICE 50 SF SUPPLY STRG. SANCTUARY LEVEL F.F.E. 8' - 4 1/4" SANCTUARY LEVEL F.F.E. 8' - 4 1/4" SANCTUARY LEVEL F.F.E. 8' - 4 1/4" EXISTINGNEW EXIST INGNEWEXISTINGNEWOPEN TO LOWER LEVEL COMMONS BELOW OPEN MECHANICAL COURTYARD (NEW) EXISTING ELEVATOR EXISTING ELEVATOR LINE OF EXISTING SCHOOL EXISTING LOBBY F.F.E. 2' -2 5/8" INFILL CLOSE-SPACED SPRINKLERS AT GLAZED OPENINGS FEC CHASE CHASE CHASE 368 SF VESTIBULE 158 SF VESTIBULE 20' - 0" 14' - 4 5/8" "IMAGINARY PROPERTY LINE" AT 1' -0" OFF OF FACE OF NEW WALL 1' - 0"4' - 5 3/8"6' - 0" 20' - 0" 36' - 8" 8' - 4" 1' - 8" STRUCTURALLY INDEPENDENT FIRE WALL77' - 1 3/8"CLOSE-SPACED SPRINKLERS AT GLAZED OPENINGS2 0' - 0"20' - 0" PASSAGE 30 SF JANITOR EXISTING NAVE TO REMAIN -NO WORK IN THIS SPACE EXISTING NAVE TO REMAIN - NO WORK IN THIS SPACE EXISTING NARTHEX TO REMAIN - NO WORK IN THIS SPACE NEW 3-HOUR FIRE BARRIER EXISTING 2-HOUR SEPARATION WALL EXISTING 2-HOUR SEPARATION WALL NEW 3-HOUR FIRE BARRIER NEW 4-HOUR STRUCTURALLY INDEPENDENT FIRE WALL NEW 4-HOUR STRUCTURALLY INDEPENDENT FIRE WALL EXISTING SCHOOL WITH GLASS BLOCK WINDOW ASSEMBLY 4-HOUR FIRE WALL EXTENDS 3' -0" BEYOND EDGE OF EXISTING SCHOOL 3' - 0"CLOSE-SPACED SPRINKLERS AT EXISTING STAINED GLASS WINDOWS (TYP.) CLOSE-SPACED SPRINKLERS AT EXISTING STAINED GLASS WINDOWS (TYP.) NEW 4-HOUR STRUCTURALLY INDEPENDENT FIRE WALL FEC FEC FEC FEC GROUND LEVEL COMMONS SANCTUARY LEVEL F.F.E. 8' - 4 1/4" ELEVATOR OFFICE/GROUND LEVEL F.F.E. 0" CORRIDOR CORRIDOR CORRIDOR CORRIDOR OFFICE/GROUND LEVEL F.F.E. 0" DN DN DN DN DN UP UP DN DN UP (SANCTUARY) DN DN 34 4 344 344 344 344344344 344 344 3 44 3 4 4 16 4 164 292 260 1 9 5 APPLICABLE CODES AND STANDARDS INDIANA BUILDING CODE -2014 (2012 INTERNATIONAL BUILDING CODE & STATE AMENDMENTS) INDIANA FIRE CODE -2014 (2012 INTERNATIONAL FIRE CODE & STATE AMENDMENTS) INDIANA ELECTRICAL CODE -2009 (2008 NATIONAL ELECTRICAL CODE & STATE AMENDMENTS) INDIANA MECHANICAL CODE -2014 (2012 INTERNATIONAL MECHANICAL CODE & STATE AMENDMENTS) INDIANA PLUMBING CODE -2012 (2006 INTERNATIONAL PLUMBING CODES & STATE AMENDMENTS) INDIANA ACCESSIBILITY CODE -(2014 I.B.C., CHAP. 11 (ANSI 117.1-2009)) INDIANA ENERGY CONSERVATION CODE -2010 (ASHRAE 90.1, 2007 EDITION WITH STATE AMENDMENTS) NFPA 10 -2010 EDITION, PORTABLE FIRE EXTINGUISHERS NFPA 13 -2010 EDITION, INSTALLATION OF SPRINKLER SYSTEMS NFPA 20 -2010 EDITION, INSTALLATION OF CENTRIFUGAL FIRE PUMPS NFPA 25 -2011 EDITION, INSPECTION TESTING AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS NFPA 70 -2008 EDITION, NATIONAL ELECTRICAL CODE NFPA 72 -2010 EDITION, NATIONAL FIRE ALARM CODE GENERAL ADMINISTRATION RULES (675 IAC 12) AMERICANS WITH DISABILITIES ACT (FEDERAL LAW) JULY 26, 1992 NON-RATED CORRIDORS (1018.1). VARIANCE 21-08-21 APPROVED TO PERMIT NON- RATED CORRIDORS IN A BUILDING NOT SPRINKLERED THROUGHOUT. DUE TO THE NAVE NOT BEING SPRINKLERED AND THE ABSENCE OF REQUIRED FIRE WALLS TO CREATE PROPER SEPARATION, THE NAVE WILL BE SEPARATED BY AN APPROVED FIRE BARRIER. VARIANCE APPROVALS (CONT.) SPRINKLER SYSTEM THIS PROJECT INCLUDES INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM INSTALLED IN THE NEW CONSTRUCTION AREA AND THE LOWER LEVEL OF THE 1974 ORIGINAL BUILDING. AT THE COMPLETION OF CONSTRUCTION, THE BUILDING WILL BE COMPLETELY SPRINKLERED WITH THE EXCEPTION OF THE NAVE. CODE SUMMARY OCCUPANCY TYPE: A-3 CONSTRUCTION TYPE: IIB, TWO STORY ASSEMBLY USES ACCESSORY TO GROUP A-3 ARE NOT CONSIDERED SEPARATE OCCUPANCIES (SECTION 508.3.1) OCCUPANCY SEPARATION IS NOT REQUIRED. VARIANCE APPROVALS EXISTING VARIANCE -2001 (1998 BUILDING CODE): 2-HOUR SEPARATION WALL PROVIDED TO SEPARATE NEW ADDITION FROM EXISTING BUILDING (504.6). VARIANCE 01-08-21 APPROVED TO PERMIT SPRINKLER-PROTECTED OPENINGS IN 2-HOUR WALL IN LIEU OF 90-MINUTE ASSEMBLIES. APPROVED VARIANCES -2021 PROXIMITY TO AN EXISTING BUILDING (705.8). VARIANCE 21-08-21 APPROVED TO PERMIT NON-RATED OPENINGS PROTECTED BY CLOSE-SPACED SPRINKLERS IN A WALL THAT IS IN CLOSE PROXIMITY TO AN IMAGINARY PROPERTY LINE ESTABLISHED BETWEEN THE NEW AND EXISTING BUILDING. TYPES OF CONSTRUCTION (GAR). VARIANCE 21-08-21 APPROVED TO PERMIT EXISTING MASONRY WALL TO SERVE AS A 3 HOUR FIRE BARRIER IN LIEU OF A 3 HOUR STRUCTURALLY INDEPENDENT FIRE WALL AND THE UPGRADE OF THE SPRINKLER SYSTEM TO ORDINARY HAZARD 1 BETWEEN CONSTRUCTION TYPE IV (EXISTING) AND II-B (NEW). AUTOMATIC SPRINKLERS THROUGHOUT (903.2.1.3). VARIANCE 21-08-21 APPROVED TO PERMIT THE NAVE TO REMAIN NON- SPRINKLERED WITHOUT A COMPLETE SEPARATION BY A FIRE BARRIER (IE: NAVE FLOOR TO BASEMENT IS NOT RATED DUE TO UNPROTECTED DUCT OPENINGS). OPENINGS IN A 4 HOUR WALL (706.8). VARIANCE 21-08-21 APPROVED TO PERMIT NON-RATED OPENINGS IN A 4 HOUR WALL TO BE PROTECTED WITH CLOSE-SPACED SPRINKLERS. BUILDING CODE ANALYSIS EGRESS NUMBER OF EXITS AND MAXIMUM TRAVEL DISTANCE AND COMMON PATH OF TRAVEL SHALL COMPLY WITH CODE REQUIREMENTS. TRAVEL DISTANCE: TABLE 1016.2 , IBC LIMITS THE MAXIMUM TRAVEL DISTANCE IN A NON-SPRINKLERED BUILDING. A OCCUPANCY 200 FEET FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS BUILDING ELEMENT: MINIMUM FIRE RESISTANCE: BEAMS 0 (TABLE 601) COLUMNS 0 (TABLE 601) EXTERIOR BEARING WALLS 0 (TABLE 601) EXTERIOR NON-BEARING WALLS 10 ≤X < 30 : 0 (TABLE 601 & 602) INTERIOR BEARING WALLS (PARTITIONS) 0 (TABLE 601 AND SEC 602.2) FLOOR CONSTRUCTION 0 (TABLE 601) ROOF CONSTRUCTION 0 (TABLE 601) CORRIDORS 0 (TABLE 1018.1) STAIRWAYS UNENCLOSED STAIRWAYS SHALL BE PERMITTED (SEC 1020.1, EXCEPTION 9) LIFE SAFETY LEGEND FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER FIRE EXTINGUISHER ON BRACKET EXIT EXITING PATH -DISTANCE OF TRAVEL NEW TO EXISTING CONSTRUCTION 2 HOUR RATED ELEVATOR SHAFT / ELEVATOR EQUIPMENT ROOMS EXISTING 2-HOUR AREA SEPARATION WALL NEW 3-HOUR FIRE BARRIER NEW 4-HOUR STRUCTURALLY INDEPENDENT FIRE WALL OPENING TO BE PROTECTED WITH CLOSE-SPACED SPRINKLERS FEC CONSTRUCTION KEY 1974 ORIGINAL 2-STORY BUILDING. SANCTUARY ABOVE. OFFICES AND MEETING ROOMS BELOW. CURRENTLY UNSPRINKLERED (LOWER LEVEL TO BE SPRINKLERED IN THIS PROJECT) 2001 NARTHEX 2-STORY ADDITION. NARTHEX ABOVE. OFFICES AND MEETING ROOMS BELOW. CURRENTLY FULLY SPRINKLERED. 2021 PROPOSED ADDITION. OFFICES AND GATHERING AREAS ABOVE. STORAGE AND MECHANICAL SPACES IN BASEMENT BELOW. TO BE SPRINKLERED. FE 2001 ADDITION -EXISTING CONSTRUCTION TYPE: IIB OCCUPANCY TYPE: A-3 SANCTUARY LEVEL: 9,551 S.F. LOWER LEVEL: 9,629 S.F. FULLY SPRINKLERED AREA SUMMARY 1974 BUILDING -EXISTING ORIGINAL BUILDING CONSTRUCTION TYPE: IV OCCUPANCY TYPE: A-3 SANCTUARY LEVEL: 10,815 S.F. LOWER LEVEL: 10,670 S.F. NOT SPRINKLERED 2021 PROPOSED ADDITION -NEW CONSTRUCTION TYPE: IIB OCCUPANCY TYPE: A-3 SANCTUARY LEVEL ADDITION: 624 S.F. OFFICE LEVEL ADDITION: 10,881 S.F. LOWER LEVEL ADDITION : 2,995 S.F. BASEMENT LEVEL ADDITION: 7,072 S.F. FULLY SPRINKLERED DRAWING TITLE: CERTIFIED BY: DRAWING NUMBER PROJECT NUMBER REVISIONS: SCOPE DRAWINGS:PROJECT: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for theproper execution and completion of the work. ISSUE DATE DRAWN BY CHECKED BY© 2018 CSO Architects, Inc. All Rights ReservedPARISH LIFE CENTER PROJECTOUR LADY OF MT. CARMEL14598 OAK RIDGE RD, CARMEL, IN 4603209/17/21 NTC CAM 19038 A102 GROUND AND SANCTUARY LEVEL LIFE SAFETY PLANCATHOLIC CHURCHSCALE: 1/8" = 1'-0" A102 1 GROUND AND SANCTUARY LEVEL LIFE SAFETY PLAN 12/13/21