HomeMy WebLinkAbout21132 - Cramer.pdfUM
MSP
170'-8"
73'-6"
9'-5"
158'-11"
109'-5"
65'-10"
20'-5"
20'-3"
54'-6"
MSP
1
2
3
PROJECT DESCRIPTION:
SHEET INDEX
PV-1 PLOT PLAN & VICINITY MAP
PV-2 ROOF PLAN & MODULES
PV-2A STRING LAYOUT
PV-3 RACKING DETAIL
PV-4 ATTACHMENT DETAIL
PV-5 ELECTRICAL LINE DIAGRAM
PV-5.1 ELECTRICAL LINE DIAGRAM
PV-6 WIRING CALCULATIONS
PV-7 PLACARDS
PLOT PLAN & VICINITY MAP PV-8+ EQUIPMENT SPECIFICATIONS
HOUSE PHOTO
VICINITY MAP
PV-1 SCALE: 1/32" = 1'
PV-1 SCALE: NTS
PV-1 SCALE: NTS
PLOT PLAN &
VICINITY MAP
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-1
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
20X340 HANWHA Q.PEAK DUO BLK-G6(340W) MODULES
ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM
SYSTEM SIZE: 6.80 KW DC STC
ROOF ACCESS POINT
ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS
UM
MSP
ACD
PW
PVC
GW
INV
MSP
PW
ROOF PLAN &
MODULES
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-2
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
ROOF DESCRIPTION
ROOF TYPE ASPHALT SHINGLE
ROOF ROOF TILT AZIMUTH RAFTER
SIZE
RAFTER
SPACING
#1 16° 115° 2"x4" 24" O.C.
ARRAY AREA WITH ROOF AREA
ROOF # OF
MODULES
ARRAY AREA
(Sq. Ft.)
ROOF
AREA
(Sq. Ft.)
ROOF
AREA
COVERED
BY ARRAY
(%)
#1 20 386.2 846.32 45.63
1
PV-2
ROOF PLAN & MODULES
SCALE: 1/8" = 1'-0"
MODULE TYPE, DIMENSIONS & WEIGHT
NUMBER OF MODULES = 20 MODULES
MODULE TYPE = HANWHA Q.PEAK DUO BLK-G6(340W) MODULES
UM
MSP
ACD
PW
PVC
GW
INV
MSP
PW
1 STRING LAYOUT
PV-2A SCALE: 1/8" = 1'-0"
STRING
LAYOUT
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-2A
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
BILL OF MATERIALS
EQUIPMENT QTY DESCRIPTION
SOLAR PV MODULES 20 HANWHA Q.PEAK DUO BLK-G6+ 340 MODULES
INVERTER 1 SOLAREDGE SE6000H-US (240V) INVERTER
OPTIMIZERS 20 SOLAREDGE POWER OPTIMIZERS P370
AC DISCONNECT 1 200A FUSED AC DISCONNECT WITH (2) 200A FUSES,240
NEMA 3R, UL LISTED
ATTACHMENT 44 ECO FASTEN FLASHING L-FEET ATTACHMENT
RAILS 10 EVEREST CR-48 RAIL RACKING SYSTEM(166")
RAIL SPLICE 0 SPLICE KIT
MID CLAMPS 28 MID CLAMPS
END CLAMPS 24 END CLAMPS / STOPPER SLEEVE
GROUNDING LUG 12 GROUNDING LUG
STRING #2 (11)
(E) BACK OF RESIDENCE
BEXHILL DR.
(E) FRONT OF RESIDENCE
STRING #1 (9)
1'-0" 19'-7"
8'-3" 13'-9" 22'-2" 10'-4"
2'-0"
RACKING DETAIL
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-3
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
1 RACKING DIAGRAM
PV-3 SCALE: 1/4"=1'-0"
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-4
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
ATTACHMENT
ATTACHMENT DETAILS
SCALE: NTS
1
PV-4
2"X4" RAFTERS @ 24" O.C
2 ATTACHMENT DETAIL (FRONT VIEW)
PV-4 SCALE: NTS
SEE (2/PV-4)
FOR ENLARGED
VIEW
PV MODULES
EVEREST CR-48 RAIL
2"X4" RAFTERS
@ 24" O.C.
(1) 5/16"Ø X 6", 18-8 SS
HANGER BOLT,PLAIN
CENTER. 2 1/2" MIN.
EMBEDMENT
PV MODULE
ECOFASTEN FLASHING
ECOFASTEN L-FOOT
MID CLAMP
(E) COMPOSITION SHINGLE ROOF
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-5
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
ELECTRICAL LINE
DIAGRAM
1 ELECTRICAL LINE DIAGRAM
PV-5 SCALE: NTS
(20) HANWHA Q.PEAK DUO BLK-G6(340W) MODULES
(01) SOLAREDGE SE6000H-US (240V) INVERTERS
(01) STRING OF 09 MODULES
(01) STRING OF 11 MODULES
(CONNECTED IN SERIES PER STRING)
SERVICE INFO
UTILITY PROVIDER:
MAIN SERVICE VOLTAGE:
MAIN PANEL BRAND:
MAIN SERVICE PANEL:
MAIN CIRCUIT BREAKER RATING:
MAIN SERVICE LOCATION:
SERVICE FEED SOURCE:
240V
200
200
OVERHEAD
DUKE INDIANA
SQUARE D
INSIDE BASEMENT
SYSTEM SIZE:
TOTAL DC SYSTEM SIZE: 6.80 kW DC
TOTAL AC SYSTEM SIZE: 6.00 kW AC
(N) HANWHA Q.PEAK DUO
BLK-G6(340W) MODULES
Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER)
Tag #
1
1
2
2
3
3
Bare Copper Ground (EGC/GEC)
THWN-2
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-6
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
WIRING
CALCULATIONS
ELECTRICAL NOTES
1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.
2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT.
3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS
POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.
4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.
5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,
SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS.
6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM
ACCORDINGLY.
7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.
8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE
GROUNDING CLIP MANUFACTURER'S INSTRUCTION.
9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.
10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE
NUMBER OF CURRENT
CARRYING CONDUCTORS IN
EMT
4-6
7-9
10-20
PERCENT OF
VALUES
.80
.70
.50
AMBIENT TEMPERATURE SPECS
AMBIENT TEMP (HIGH TEMP 2%)
RECORD LOW TEMP -22°
32°
CONDUIT HEIGHT 0.5"
ROOF TOP TEMP 54°
CONDUCTOR TEMPERATURE RATE 90°
MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%/°C
INVERTER SPECIFICATIONS
MANUFACTURER
MODEL # SE6000H-US (240V)
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-7
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
PLACARDS
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN
AT:
RATED MAXIMUM POWER- .
POINT CURRENT (Imp) .
RATED MAXIMUM POWER- .
POINT VOLTAGE (Vmp) .
MAXIMUM SYSTEM .
VOLTAGE (VOC) .
MAXIMUM CIRCUIT .
CURRENT (Isc) .
380
480
30
17.89 A
V
LABEL LOCATION:
DC DISCONNECT, INVERTER
(PER CODE: CEC690.53)
V
A
INVERTER #1
LABEL LOCATION:
AT MSP : NEC 705.10 & 690.56 (B)
SOLAR DISCONNECT
LABEL LOCATION:
AC DISCONNECT, POINT OF INTERCONNECTION
(PER CODE: CEC690.13(B))
PHOTOVOLTAIC SYSTEM AC DISCONNECT
RATED AC OPERATING CURRENT 25.0 AMPS
AC NOMINAL OPERATING VOLTAGE 240 VOLTS
LABEL LOCATION:
DISCONNECT, POINT OF INTERCONNECTION
(PER CODE: CEC690.13(B))
PER NEC 705.12(B)(2)(3)(c)
THIS EQUIPMENT FED BY MULTIPLE
SOURCES. TOTAL RATING OF ALL
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-8
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
EQUIPMENT
SPECIFICATION
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-9
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
EQUIPMENT
SPECIFICATION
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-10
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
EQUIPMENT
SPECIFICATION
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-11
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
EQUIPMENT
SPECIFICATION
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-12
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
EQUIPMENT
SPECIFICATION
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-13
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
EQUIPMENT
SPECIFICATION
REV
SHEET NAME
SHEET SIZE
SHEET NUMBER
DANIEL CRAMER
144 BEXHILL DR.,
CARMEL, IN 46032, USA
ANSI B
11" X 17"
DESCRIPTION DATE
REVISIONS
Signature with Seal
PROJECT NAME & ADDRESS
PV-14
SOLAR ENERGY SOLUTIONS
1038 BRENTWOOD CT, STE B
LEXINGTON, KY 40511
TEL: (877) 312-7456
JOB NUMBER
21132
11/18/2021
EQUIPMENT
SPECIFICATION
OVERCURRENT DEVICES, EXCLUDING
MAIN SUPPLY OVERCURRENT
DEVICE, SHALL NOT EXCEED
AMPACITY OF BUSBAR
WARNING
WARNING: PHOTOVOLTIC
POWER SOURCE
Per NEC 690.31(G) (3)(4) Place on all source markings.
WARNING Place on Conduit every 10 ft. (IFC 605.11.1.1 and IFC 605.11.1.2)
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE.
PER NEC 705.12(B)(2)(3)(b)
PHOTOVOLTAIC SYSTEM EQUIPPED WITH
RAPID SHUTDOWN
PER NEC 690.56(C)
WARNING
DUAL POWER SOURCE
SOURCES: UTILITY GRID AND
PV SOLAR ELECTRIC SYSTEM
4" x 2", RED AND WHITE LETTERS
PER NEC 705.12(D)(3) & NEC 690.64
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS. TERMINALS ON BOTH
THE LINE AND LOAD SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
WARNING
PER NEC 690.13 (B)
THIS EQUIPMENT FED BY MULTIPLE
SOURCES. TOTAL RATING OF ALL
OVERCURRENT DEVICES, EXCLUDING
MAIN SUPPLY OVERCURRENT
DEVICE, SHALL NOT EXCEED
AMPACITY OF BUSBAR
WARNING
PER NEC 705.12(B)(2)(3)(c)
Per NEC NEC 690.13(B)
PHOTOVOLTIC
AC DISCONNECT
WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE.
PER NEC 705.12(B)(2)(3)(b)
MAIN SERVICE/UTILITY METER
AC DISCONNECT
INVERTER, BATTERY
BACKUP GATEWAY, LOAD CENTER
(E) MAIN SERVICE
PANEL (INSIDE
BASEMENT)
(N) INVERTER (INSIDE
BASEMENT)
(N) BACKUP GATEWAY
(INSIDE BASEMENT)
SOLAR ARRAY
(N) TESLA POWERWALL
(INSIDE BASEMENT)
(N) FUSED-AC
DISCONNECT
(E) UTILITY METER
BEXHILL DR.
SOLAREDGE
NOMINAL AC POWER 6.00 KW
NOMINAL OUTPUT VOLTAGE 240V
NOMINAL OUTPUT CURRENT 25.0A
SOLAR MODULE SPECIFICATIONS
MANUFACTURER
MODEL #
PMAX
VMP
IMP
VOC
ISC
340W
Q.PEAK DUO BLK-G6(340W) MODULES
HANWHA SOLAR
MODULE DIMENSION
33.94A
10.02A
40.66V
10.52A
68.5"x 40.6" x 1.26"D (In Inch)
DC CONDUCTOR AMPACITY CALCULATIONS:
ARRAY TO JUNCTION BOX:
EXPECTED WIRE TEMP (In Celsius)
NO. OF CURRENT CARRYING CONDUCTORS
CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)
CIRCUIT CONDUCTOR SIZE
1
10 AWG
2
32
TEMP. CORRECTION PER TABLE (310.16) 0.96
CIRCUIT CONDUCTOR AMPACITY 40A
REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)
1.25 X 1.25 X Isc
16.44A
DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16
TEMP. CORRECTION PER TABLE (310.16) X
CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X
CIRCUIT CONDUCTOR AMPACITY
38.4A
Result should be greater than (16.44A) otherwise less the entry for circuit conductor size
and ampacity
DC CONDUCTOR AMPACITY CALCULATIONS:
FROM JUNCTION BOX TO INVERTER:
AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT
PER NEC 310.15(B)(2)(c)
NO. OF CURRENT CARRYING CONDUCTORS
CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)
CIRCUIT CONDUCTOR SIZE
.80
10AWG
4
+22
TEMP. CORRECTION PER TABLE (310.16) 0.76
CIRCUIT CONDUCTOR AMPACITY 40A
REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)
1.25 X 1.25 X Isc
DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16
TEMP. CORRECTION PER TABLE (310.16) X
CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X
CIRCUIT CONDUCTOR AMPACITY
24.32A
Result should be greater than (16.44A) otherwise less the entry for circuit conductor size
and ampacity
EXPECTED WIRE TEMP (In Celsius) 32 +22 = 54
AC CONDUCTOR AMPACITY CALCULATIONS:
FROM INVERTER TO BACKUP GATEWAY:
No. OF INVERTER
NO. OF CURRENT CARRYING CONDUCTORS
CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)
CIRCUIT CONDUCTOR SIZE
1
8AWG
3
1
TEMP. CORRECTION PER TABLE (310.16) 0.94
CIRCUIT CONDUCTOR AMPACITY 50 A
EXPECTED WIRE TEMP (In Celsius) 32
REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B)
1.25 X MAX INVERTER OUTPUT CURRENT
31.25A
DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16
TEMP. CORRECTION PER TABLE (310.16) X
CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X
CIRCUIT CONDUCTOR AMPACITY
47.0A
Result should be greater than (31.25A) otherwise less the entry for circuit conductor size
and ampacity
16.44A
AC CONDUCTOR AMPACITY CALCULATIONS:
FROM BACKUP GATEWAY TO METER:
No. OF INVERTER
NO. OF CURRENT CARRYING CONDUCTORS
CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)
CIRCUIT CONDUCTOR SIZE
1
3/0AWG
3
1
TEMP. CORRECTION PER TABLE (310.16) 0.94
CIRCUIT CONDUCTOR AMPACITY 200 A
EXPECTED WIRE TEMP (In Celsius) 32
REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B)
1.25 X MAX INVERTER OUTPUT CURRENT
31.25A
DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16
TEMP. CORRECTION PER TABLE (310.16) X
CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X
CIRCUIT CONDUCTOR AMPACITY
188A
Result should be greater than (31.25A) otherwise less the entry for circuit conductor size
and ampacity
PV WIRE
THWN-2 - Ground
THWN-2
THWN-2 - Ground
Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size
10 AWG
6 AWG
10 AWG
8 AWG
8 AWG
8 AWG
2 (1V+, 1V-)
1 BARE
4 (2V+, 2V-) B/R
1 (GRN)
3 (1L1, 1L2, 1N) B/R/W
1 (GRN)
N/A-Free Air
N/A-Free Air
EMT
N/A-Free Air
N/A-Free Air
EMT
EMT
3/4"
3/4"
4 3/0 AWG
4 THWN-2 - Ground 6 AWG 1 (GRN)
THWN-2 3 (1L1, 1L2, 1N) B/R/W EMT
EMT
EMT
3/4"
3/4"
DC DC DC AC
- +
- + +
- +
- + - + - +
2
- +
-
1 3
=
=
=
=
=
=
=
=
=
=
- + - +
- +
- + +
- +
- + - + - +
2
- +
-
1 3
=
=
=
=
=
=
=
=
=
=
8 9
- + - +
10 11
CTRL
TO
(N) POWERWALL
TESLA P/N 1092170-XX-X
5KW, 13.5KWH
NEMA 3R
(4) [24-16] AWG THWN-2
(3) [10-8] AWG THWN-2
(1) [10-8] AWG GND
(N) BACKUP
GATEWAY (INSIDE
BASEMENT))
TESLA P/N
1118431-XX-X
200A MAX,
NEMA 3R
(E) MAIN BREAKER
TO HOUSE 240 V,
200A, (TOP FED)
GEC
GROUNDING
ELECTRODE
SYSTEM
(E) MAIN SERVICE
PANEL, 200A RATED,
240V(INSIDE BASEMENT)
1
L1
L2
N
G
L1
L2
N
G
M
CTRL
N G
(N) BACKUP
GATEWAY
TESLA P/N
1118431-XX-X
200A MAX,
NEMA 3R
TO TO 6
200A
4
CT LEADS BY TESLA
L1
L2
40A/2P
L1
L2
2
30A/2P
3
4
G
N
200A
L1
L2
NOTE:
LARGEST LOAD EXISTING IN
MAIN SERVICE PANEL=40A
CUSTOMER TO MANAGE LARGE
LOAD IN GRID OUTAGE EVENT.
ALL OTHER EXISTING
LOADS=30A OR LESS
M
L1 L2
TO UTILITY GRID
N
SOLAREDGE: SE6000H-US INVERTER 4
OUTPUT: 240VAC, 25.0A
99% CEC WEIGHTED EFFICIENCY
NEMA 3R, UL LISTED, INTERNAL GFDI
WITH INTEGRATED DC DISCONNECT
JUNCTION BOX
(N) AC DISCONNECT:
200A FUSED WITH, (2)
200A FUSES, 240V NEMA
3R, UL LISTED
2"
2"
MODULE WEIGHT = 43.9 LBS / 19.9 KG.
MODULE DIMENSIONS = 68.5"x 40.6" = 19.31 SF
UNIT WEIGHT OF ARRAY = 2.27PSF
HANWHA Q.PEAK
DUO BLK-G6(340W)
40.6"
68.5"
GW - BACKUP GATEWAY
PW - TESLA POWER WALL
(E) BACK OF RESIDENCE
(N) JUNCTION BOX (TYP.)
3/4" EMT CONDUIT
LEGEND
INV - INVERTER
MSP - MAIN SERVICE PANEL
- VENTS, (ROOF OBSTRUCTION)
- ROOF ATTACHMENT
- RAFTERS
- CONDUIT
UM - UTILITY METER
- SOLAREDGE OPTIMIZER
- CHIMNEY
ACD - AC DISCONNECT
(N) FUSED AC DISCONNECT
(E) UTILITY METER
(E) MAIN SERVICE PANEL
(N) TESLA POWERWALL
(N) BACKUP GATEWAY
(N) SOLAREDGE SE 6000H-US
(240V) INVERTER JB - JUNCTION BOX
BEXHILL DR.
(E) FRONT OF RESIDENCE
ROOF #1
(20) HANWHA Q.PEAK DUO
BLK-G6(340W) MODULES
(20) SOLAREDGE POWER
OPTIMIZERS P370
(N) EVEREST CR-48 RACKING SYSTEM
(44) PV ATTACHMENTS @ 72" O.C.
ROOF #1
TILT - 16
°
AZIM. -115
°
THAT REQUIRE THE PLACEMENT OF GROUND LADDERS
OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND
SHALL BE LOCATED AT STRONG POINTS OF BUILDING
CONSTRUCTION IN LOCATIONS WHERE THE ACCESS
POINT DOES NOT CONFLICT WITH OVERHEAD
OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.
PROJECT SITES
EXISTING
NEW
(E)
(N)
DESCRIPTION
EQUIPMENT SUMMARY
20 HANWHA Q.PEAK DUO BLK-G6(340W) MODULES
01 SOLAREDGE SE6000H-US (240V) INVERTER
20 SOLAREDGE POWER OPTIMIZERS P370
ROOF ACCESS POINT
DESIGN SPECIFICATIONS
EXPOSURE CATEGORY = B
WIND SPEED = 115 MPH
GROUND SNOW LOAD = 20 PSF
ZONING = RESIDENTIAL
CONSTRUCTION = SINGLE FAMILY
1-STORY
HOUSE
(E) MAIN SERVICE
PANEL (INSIDE)
PROJECT SITE
ROOF #1
(20) HANWHA Q.PEAK DUO
BLK-G6(340W) MODULES
(E) UTILITY METER
EXISTING
DRIVEWAY
GOVERNING CODES
ALL WORK SHALL CONFORM TO THE FOLLOWING CODES
2018 IN BUILDING CODE
2018 IN RESIDENTIAL CODE
2018 IN PLUMBING CODE
2017 NFPA 70-NATIONAL ELECTRICAL CODE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
BEXHILL DR.
STRUCTURE