Loading...
HomeMy WebLinkAbout21132 - Cramer.pdfUM MSP 170'-8" 73'-6" 9'-5" 158'-11" 109'-5" 65'-10" 20'-5" 20'-3" 54'-6" MSP 1 2 3 PROJECT DESCRIPTION: SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-2A STRING LAYOUT PV-3 RACKING DETAIL PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-5.1 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PLOT PLAN & VICINITY MAP PV-8+ EQUIPMENT SPECIFICATIONS HOUSE PHOTO VICINITY MAP PV-1 SCALE: 1/32" = 1' PV-1 SCALE: NTS PV-1 SCALE: NTS PLOT PLAN & VICINITY MAP REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 20X340 HANWHA Q.PEAK DUO BLK-G6(340W) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM SYSTEM SIZE: 6.80 KW DC STC ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS UM MSP ACD PW PVC GW INV MSP PW ROOF PLAN & MODULES REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLE ROOF ROOF TILT AZIMUTH RAFTER SIZE RAFTER SPACING #1 16° 115° 2"x4" 24" O.C. ARRAY AREA WITH ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 20 386.2 846.32 45.63 1 PV-2 ROOF PLAN & MODULES SCALE: 1/8" = 1'-0" MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 20 MODULES MODULE TYPE = HANWHA Q.PEAK DUO BLK-G6(340W) MODULES UM MSP ACD PW PVC GW INV MSP PW 1 STRING LAYOUT PV-2A SCALE: 1/8" = 1'-0" STRING LAYOUT REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2A SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 20 HANWHA Q.PEAK DUO BLK-G6+ 340 MODULES INVERTER 1 SOLAREDGE SE6000H-US (240V) INVERTER OPTIMIZERS 20 SOLAREDGE POWER OPTIMIZERS P370 AC DISCONNECT 1 200A FUSED AC DISCONNECT WITH (2) 200A FUSES,240 NEMA 3R, UL LISTED ATTACHMENT 44 ECO FASTEN FLASHING L-FEET ATTACHMENT RAILS 10 EVEREST CR-48 RAIL RACKING SYSTEM(166") RAIL SPLICE 0 SPLICE KIT MID CLAMPS 28 MID CLAMPS END CLAMPS 24 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 12 GROUNDING LUG STRING #2 (11) (E) BACK OF RESIDENCE BEXHILL DR. (E) FRONT OF RESIDENCE STRING #1 (9) 1'-0" 19'-7" 8'-3" 13'-9" 22'-2" 10'-4" 2'-0" RACKING DETAIL REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 1 RACKING DIAGRAM PV-3 SCALE: 1/4"=1'-0" REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 ATTACHMENT ATTACHMENT DETAILS SCALE: NTS 1 PV-4 2"X4" RAFTERS @ 24" O.C 2 ATTACHMENT DETAIL (FRONT VIEW) PV-4 SCALE: NTS SEE (2/PV-4) FOR ENLARGED VIEW PV MODULES EVEREST CR-48 RAIL 2"X4" RAFTERS @ 24" O.C. (1) 5/16"Ø X 6", 18-8 SS HANGER BOLT,PLAIN CENTER. 2 1/2" MIN. EMBEDMENT PV MODULE ECOFASTEN FLASHING ECOFASTEN L-FOOT MID CLAMP (E) COMPOSITION SHINGLE ROOF REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 ELECTRICAL LINE DIAGRAM 1 ELECTRICAL LINE DIAGRAM PV-5 SCALE: NTS (20) HANWHA Q.PEAK DUO BLK-G6(340W) MODULES (01) SOLAREDGE SE6000H-US (240V) INVERTERS (01) STRING OF 09 MODULES (01) STRING OF 11 MODULES (CONNECTED IN SERIES PER STRING) SERVICE INFO UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 200 200 OVERHEAD DUKE INDIANA SQUARE D INSIDE BASEMENT SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 6.80 kW DC TOTAL AC SYSTEM SIZE: 6.00 kW AC (N) HANWHA Q.PEAK DUO BLK-G6(340W) MODULES Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) Tag # 1 1 2 2 3 3 Bare Copper Ground (EGC/GEC) THWN-2 REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 AMBIENT TEMPERATURE SPECS AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP -22° 32° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 54° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%/°C INVERTER SPECIFICATIONS MANUFACTURER MODEL # SE6000H-US (240V) REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 PLACARDS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT: RATED MAXIMUM POWER- . POINT CURRENT (Imp) . RATED MAXIMUM POWER- . POINT VOLTAGE (Vmp) . MAXIMUM SYSTEM . VOLTAGE (VOC) . MAXIMUM CIRCUIT . CURRENT (Isc) . 380 480 30 17.89 A V LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) V A INVERTER #1 LABEL LOCATION: AT MSP : NEC 705.10 & 690.56 (B) SOLAR DISCONNECT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 25.0 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) PER NEC 705.12(B)(2)(3)(c) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER DANIEL CRAMER 144 BEXHILL DR., CARMEL, IN 46032, USA ANSI B 11" X 17" DESCRIPTION DATE REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21132 11/18/2021 EQUIPMENT SPECIFICATION OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING WARNING: PHOTOVOLTIC POWER SOURCE Per NEC 690.31(G) (3)(4) Place on all source markings. WARNING Place on Conduit every 10 ft. (IFC 605.11.1.1 and IFC 605.11.1.2) INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. PER NEC 705.12(B)(2)(3)(b) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.56(C) WARNING DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM 4" x 2", RED AND WHITE LETTERS PER NEC 705.12(D)(3) & NEC 690.64 ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING PER NEC 690.13 (B) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING PER NEC 705.12(B)(2)(3)(c) Per NEC NEC 690.13(B) PHOTOVOLTIC AC DISCONNECT WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. PER NEC 705.12(B)(2)(3)(b) MAIN SERVICE/UTILITY METER AC DISCONNECT INVERTER, BATTERY BACKUP GATEWAY, LOAD CENTER (E) MAIN SERVICE PANEL (INSIDE BASEMENT) (N) INVERTER (INSIDE BASEMENT) (N) BACKUP GATEWAY (INSIDE BASEMENT) SOLAR ARRAY (N) TESLA POWERWALL (INSIDE BASEMENT) (N) FUSED-AC DISCONNECT (E) UTILITY METER BEXHILL DR. SOLAREDGE NOMINAL AC POWER 6.00 KW NOMINAL OUTPUT VOLTAGE 240V NOMINAL OUTPUT CURRENT 25.0A SOLAR MODULE SPECIFICATIONS MANUFACTURER MODEL # PMAX VMP IMP VOC ISC 340W Q.PEAK DUO BLK-G6(340W) MODULES HANWHA SOLAR MODULE DIMENSION 33.94A 10.02A 40.66V 10.52A 68.5"x 40.6" x 1.26"D (In Inch) DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 10 AWG 2 32 TEMP. CORRECTION PER TABLE (310.16) 0.96 CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 16.44A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 38.4A Result should be greater than (16.44A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE .80 10AWG 4 +22 TEMP. CORRECTION PER TABLE (310.16) 0.76 CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 24.32A Result should be greater than (16.44A) otherwise less the entry for circuit conductor size and ampacity EXPECTED WIRE TEMP (In Celsius) 32 +22 = 54 AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO BACKUP GATEWAY: No. OF INVERTER NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 8AWG 3 1 TEMP. CORRECTION PER TABLE (310.16) 0.94 CIRCUIT CONDUCTOR AMPACITY 50 A EXPECTED WIRE TEMP (In Celsius) 32 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX INVERTER OUTPUT CURRENT 31.25A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 47.0A Result should be greater than (31.25A) otherwise less the entry for circuit conductor size and ampacity 16.44A AC CONDUCTOR AMPACITY CALCULATIONS: FROM BACKUP GATEWAY TO METER: No. OF INVERTER NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 3/0AWG 3 1 TEMP. CORRECTION PER TABLE (310.16) 0.94 CIRCUIT CONDUCTOR AMPACITY 200 A EXPECTED WIRE TEMP (In Celsius) 32 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX INVERTER OUTPUT CURRENT 31.25A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 188A Result should be greater than (31.25A) otherwise less the entry for circuit conductor size and ampacity PV WIRE THWN-2 - Ground THWN-2 THWN-2 - Ground Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size 10 AWG 6 AWG 10 AWG 8 AWG 8 AWG 8 AWG 2 (1V+, 1V-) 1 BARE 4 (2V+, 2V-) B/R 1 (GRN) 3 (1L1, 1L2, 1N) B/R/W 1 (GRN) N/A-Free Air N/A-Free Air EMT N/A-Free Air N/A-Free Air EMT EMT 3/4" 3/4" 4 3/0 AWG 4 THWN-2 - Ground 6 AWG 1 (GRN) THWN-2 3 (1L1, 1L2, 1N) B/R/W EMT EMT EMT 3/4" 3/4" DC DC DC AC - + - + + - + - + - + - + 2 - + - 1 3 = = = = = = = = = = - + - + - + - + + - + - + - + - + 2 - + - 1 3 = = = = = = = = = = 8 9 - + - + 10 11 CTRL TO (N) POWERWALL TESLA P/N 1092170-XX-X 5KW, 13.5KWH NEMA 3R (4) [24-16] AWG THWN-2 (3) [10-8] AWG THWN-2 (1) [10-8] AWG GND (N) BACKUP GATEWAY (INSIDE BASEMENT)) TESLA P/N 1118431-XX-X 200A MAX, NEMA 3R (E) MAIN BREAKER TO HOUSE 240 V, 200A, (TOP FED) GEC GROUNDING ELECTRODE SYSTEM (E) MAIN SERVICE PANEL, 200A RATED, 240V(INSIDE BASEMENT) 1 L1 L2 N G L1 L2 N G M CTRL N G (N) BACKUP GATEWAY TESLA P/N 1118431-XX-X 200A MAX, NEMA 3R TO TO 6 200A 4 CT LEADS BY TESLA L1 L2 40A/2P L1 L2 2 30A/2P 3 4 G N 200A L1 L2 NOTE: LARGEST LOAD EXISTING IN MAIN SERVICE PANEL=40A CUSTOMER TO MANAGE LARGE LOAD IN GRID OUTAGE EVENT. ALL OTHER EXISTING LOADS=30A OR LESS M L1 L2 TO UTILITY GRID N SOLAREDGE: SE6000H-US INVERTER 4 OUTPUT: 240VAC, 25.0A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT JUNCTION BOX (N) AC DISCONNECT: 200A FUSED WITH, (2) 200A FUSES, 240V NEMA 3R, UL LISTED 2" 2" MODULE WEIGHT = 43.9 LBS / 19.9 KG. MODULE DIMENSIONS = 68.5"x 40.6" = 19.31 SF UNIT WEIGHT OF ARRAY = 2.27PSF HANWHA Q.PEAK DUO BLK-G6(340W) 40.6" 68.5" GW - BACKUP GATEWAY PW - TESLA POWER WALL (E) BACK OF RESIDENCE (N) JUNCTION BOX (TYP.) 3/4" EMT CONDUIT LEGEND INV - INVERTER MSP - MAIN SERVICE PANEL - VENTS, (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT UM - UTILITY METER - SOLAREDGE OPTIMIZER - CHIMNEY ACD - AC DISCONNECT (N) FUSED AC DISCONNECT (E) UTILITY METER (E) MAIN SERVICE PANEL (N) TESLA POWERWALL (N) BACKUP GATEWAY (N) SOLAREDGE SE 6000H-US (240V) INVERTER JB - JUNCTION BOX BEXHILL DR. (E) FRONT OF RESIDENCE ROOF #1 (20) HANWHA Q.PEAK DUO BLK-G6(340W) MODULES (20) SOLAREDGE POWER OPTIMIZERS P370 (N) EVEREST CR-48 RACKING SYSTEM (44) PV ATTACHMENTS @ 72" O.C. ROOF #1 TILT - 16 ° AZIM. -115 ° THAT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND SHALL BE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. PROJECT SITES EXISTING NEW (E) (N) DESCRIPTION EQUIPMENT SUMMARY 20 HANWHA Q.PEAK DUO BLK-G6(340W) MODULES 01 SOLAREDGE SE6000H-US (240V) INVERTER 20 SOLAREDGE POWER OPTIMIZERS P370 ROOF ACCESS POINT DESIGN SPECIFICATIONS EXPOSURE CATEGORY = B WIND SPEED = 115 MPH GROUND SNOW LOAD = 20 PSF ZONING = RESIDENTIAL CONSTRUCTION = SINGLE FAMILY 1-STORY HOUSE (E) MAIN SERVICE PANEL (INSIDE) PROJECT SITE ROOF #1 (20) HANWHA Q.PEAK DUO BLK-G6(340W) MODULES (E) UTILITY METER EXISTING DRIVEWAY GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 2018 IN BUILDING CODE 2018 IN RESIDENTIAL CODE 2018 IN PLUMBING CODE 2017 NFPA 70-NATIONAL ELECTRICAL CODE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE BEXHILL DR. STRUCTURE