Loading...
HomeMy WebLinkAbout21152 - Schwarzin88'-9"55'-0"88'-9"55'-0"19'-1" 18'-7"1'-0"1'-0"MSPUM1 2 3 PROJECT DESCRIPTION: SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-2A STRING LAYOUT PV-3 RACKING DETAIL PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PV-8+ EQUIPMENT SPECIFICATIONSPLOT PLAN & VICINITY MAP HOUSE PHOTO VICINITY MAP SCALE: 1/16" = 1'PV-1 SCALE: NTSPV-1 PV-1 SCALE: NTS PROJECT SITE PLOT PLAN & VICINITY MAP REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 18X 340 HANWHA Q PEAK DUO G6 340W (340W) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM SYSTEM SIZE: 6.12 KW DC STC EQUIPMENT SUMMARY 18 HANWHA Q PEAK DUO G6 340W (340W) MODULES 01 SOLAR EDGE SE6000H-US (240V) INVERTERS 18 SOLAR EDGE POWER OPTIMIZERS P370 ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND SHALL BE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. PROJECT SITES DESIGN SPECIFICATIONS EXPOSURE CATEGORY = B WIND SPEED = 115MPH GROUND SNOW LOAD = 20 PSF ZONING = RESIDENTIAL CONSTRUCTION = SINGLE FAMILY EXISTING NEW (E) (N) DESCRIPTION ROOF ACCESS POINT (E)MAIN SERVICE PANEL (INSIDE GARAGE) EXISTING DRIVEWAY GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 2018 IN BUILDING CODE 2018 IN RESIDENTIAL CODE 2018 IN PLUMBING CODE 2017 NFPA 70-NATIONAL ELECTRICAL CODE (E) UTILITY METER ROOF #2 (13) HANWHA Q PEAK DUO G6 340W (340W) MODULES ROOF #1 (5) HANWHA Q PEAK DUO G6 340W (340W) MODULES 1-STORY HOUSE CAMBERLEY LN.PROPERTY LINE PROPERTY LINEPROPERTY LINE PROPERTY LINEFENCE 12/16/21 SD INVMSPUMACDROOF PLAN & MODULES REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLE ROOF ROOF ROOF TILT AZIMUTH RAFTER SIZE RAFTER SPACING #1 33° 90° 2"x4" 24" O.C. #2 33° 180° 2"x4" 24" O.C. ARRAY AREA WITH ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 5 96.55 244.20 39.54 #2 13 251.03 505.42 49.67 LEGEND - INVERTERINV MSP - MAIN SERVICE PANEL - VENTS, (ROOF OBSTRUCTION) -RAFTERS -CONDUIT - UTILITY METERUM 1 PV-2 ROOF PLAN & MODULES SCALE: 1/8" = 1'-0" - SOLAREDGE OPTIMIZER -CHIMNEY MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 18 MODULES MODULE TYPE = HANWHA Q PEAK DUO G6 340W (340W) MODULES MODULE WEIGHT = 43.9 LBS / 19.9 KG. MODULE DIMENSIONS = 68.50"x 40.6" = 19.31 SF UNIT WEIGHT OF ARRAY = 2.27PSF HANWHA Q PEAK DUO G6 340W (340W) MODULES 40.6"68.50"10/2 MC - AC DISCONNECTACD (E)MAIN SERVICE PANEL (INSIDE GARAGE) (N)01 SOLAREDGE INVERTERS (SE6000H-US) (69)TESLA ZEP ROOF MOUNT SYSTEM ATTACHMENTS @ 72" O.C. (E)UTILITY METER - PVC JUNCTION BOXJB -ZEP ATTACHMENT ROOF #2 TILT - 33° AZIM. - 180° (18) SOLAREDGE POWER OPTIMIZERS P370 ROOF #2 (13) HANWHA Q PEAK DUO G6 340W (340W) MODULES ROOF #1 (5)HANWHA Q PEAK DUO G6 340W (340W) MODULES (N)NON FUSED AC DISCONNECT(E)FRONT OF HOUSECAMBERLEY LN.ROOF #1 TILT - 33° AZIM. - 90°(E)BACK OF HOUSESOLADECK 12/16/21 SD INVMSPUMACD1 STRING LAYOUT PV-2A SCALE: 1/8" = 1'-0" STRING LAYOUT REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2A SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 STRING #2(9) STRING #1(9)(E)FRONT OF HOUSECAMBERLEY LN.(E)BACK OF HOUSEBILL OF MATERIALS m QTY DESCRIPTION SOLAR PV MODULES 18 HANWHA Q PEAK DUO G6 340W (340W) MODULES INVERTER 1 SOLAREDGE SE6000H-US (240V) INVERTER OPTIMIZERS 18 SOLAREDGE POWER OPTIMIZERS P340 AC DISCONNECT 1 60A NON-FUSED,240 NEMA 3R, UL LISTED ATTACHMENT 69 TESLA ZEP ROOF MOUNT SYSTEM ATTACHMENTS GROUNDING LUG 16 GROUNDING LUG 12/16/21 28'-10" 1'-8"3'-6" 13'-9"1'-9"4'-3"10'-4" 4'-6" 1'-2"11'-6"1'-6"7'-0"RACKING DETAIL REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 1 RACKING DIAGRAM PV-3 SCALE: 3/16"=1'-0" 12/16/21 REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4-A SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 ATTACHMENT PV MODULE PV MODULE MOUNTING BLOCK MOUNTING BLOCK CAPTURED WASHER LAG CAPTURED WASHER LAG 2"x4" RAFTERS @ 24" O.C. 2"x4" RAFTERS @ 24" O.C. LEVELING FOOT FLASHING MOUNTING BLOCK FLASHING ARRAY SKIRT KEY PORTION TOUNGE PORTION SINGLE LAYER OF COMP SHINGLE ROOF SINGLE LAYER OF COMP SHINGLE ROOF 1 ATTACHMENT DETAIL PV-4-A SCALE: NTS SEE (PV-4) FOR ENLARGED VIEW PV MODULE SINGLE LAYER OF COMP SHINGLE ROOF 2"x4" RAFTER S @ 2 4 " O . C . SEE (PV-4) FOR ENLARGED VIEW 2 ATTACHMENT DETAIL PV-4-A SCALE: NTS 12/16/21 REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 ELECTRICAL LINE DIAGRAM 1 ELECTRICAL LINE DIAGRAM PV-5 SCALE: NTS SERVICE INFO UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 200 200 UNDERGROUND DUKE INDIANA CHALLENGER INSIDE GARAGE (18) HANWHA Q PEAK DUO G6 340W (340W) MODULES (01) SOLAREDGE SE 6000H-US (240V) INVERTER (18) SOLAREDGE POWER OPTIMIZERS P370 (02) STRINGS OF 9 MODULES (CONNECTED IN SERIES PER STRING) Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) Tag # 1 1 2 2 3 3 Bare Copper Ground (EGC/GEC) PV WIRE THWN-2 THWN-2 - Ground Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size 10 AWG 6 AWG 10 AWG 8 AWG 8 AWG 8 AWG 2 (1V+, 1V-) 1 BARE 4 (2V+, 2V-) B/R 1 (GRN) 3 (1L1, 1L2, 1N) B/R/W 1 (GRN) N/A-Free Air N/A-Free Air MC N/A-Free Air N/A-Free Air MC EMT EMT SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 6.12 kW DC TOTAL AC SYSTEM SIZE: 6.00 kW AC 3/4" SolarEdge Power Optimizer P370 Rated DC Input Power - 370 watts Maximum Input Voltage - 60 Vdc MPPT Range - 8 to 60 Vdc Maximum Input Current - 13.75 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 5700 watts STC per string maximum (N) HANWHA Q PEAK DUO G6 340W (340W) MODULES 3/4" 10/2 10/2 = DC AC SOLADECK - + - + + - + + + + - - - 2 - + - 1 3 = = = = = = = = = = - + - + 2 1 SOLAREDGE: SE6000H-US (240V) INVERTER OUTPUT : 240 VAC, 25.0A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 8 9 3 - + - + + - + + + +- - - 2 - + - 1 3 = = === = = = = = - + - + 8 9 THWN-2 THWN-2 - Ground 3 (E) MAIN BREAKER TO HOUSE 240 V, 200A, (TOP FED) BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V UTILITY METER GEC G N L2 L1 M TO UTILITY GRID GROUNDING ELECTRODE SYSTEM N 200A L1 L2 L1 L2 (E) MAIN SERVICE PANEL, 200A RATED, 240V(INSIDE GARAGE) 40A 2P N G N G L2 L2 L1L1 (N) AC DISCONNECT: 240V, 60 AMP NON FUSED NEMA 3R, UL LISTED (OUTSIDE GARAGE) INTERCONNECTION 120% RULE CALCULATION PER 705.12(D)(2) UTILITY FEED + SOLAR BACKFEED 200 A + 40A = 240A BUSS RATING x 120% 200 A x 120% = 240A 12/16/21 REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 AMBIENT TEMPERATURE SPECS AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP -22° 32° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 54° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%/°K SOLAR MODULE SPECIFICATIONS MANUFACTURER MODEL # PMAX VMP IMP VOC ISC 340W Q PEAK DUO G6 340W HANWHA SOLAR MODULE DIMENSION 33.94A 10.02A 40.66V 10.52A 68.50"x 40.6" x 1.26"D (In Inch) EXPECTED WIRE TEMP (In Celsius) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 10 AWG 2 32 TEMP. CORRECTION PER TABLE (310.16)0.96 CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 16.44A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 38.40A Result should be greater than (16.44A) otherwise less the entry for circuit conductor size and ampacity REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 16.44A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 24.32A Result should be greater than (16.44A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO MSP: No. OF INVERTER NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 1 8AWG 3 1 TEMP. CORRECTION PER TABLE (310.16)0.94 CIRCUIT CONDUCTOR AMPACITY 50A EXPECTED WIRE TEMP (In Celsius)32 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX INVERTER OUTPUT CURRENT 31.25A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY 47.0A Result should be greater than (31.25A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER : AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c) NO. OF CURRENT CARRYING CONDUCTORS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) CIRCUIT CONDUCTOR SIZE 0.80 10 AWG 4 +22 TEMP. CORRECTION PER TABLE (310.16)0.76 CIRCUIT CONDUCTOR AMPACITY 40A EXPECTED WIRE TEMP (In Celsius)32 +22 = 54 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX : INVERTER SPECIFICATIONS MANUFACTURER MODEL #SE6000H-US SOLAREDGE NOMINAL AC POWER 6.00KW NOMINAL OUTPUT VOLTAGE 240V NOMINAL OUTPUT CURRENT 25.0A 12/16/21 REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 PLACARDS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT: MAIN SERVICE/UTILITY METER LABEL LOCATION: AT MSP : NEC 705.10 & 690.56 (B) SOLAR DISCONNECT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 25.0 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) PER NEC 705.12(B)(2)(3)(c) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING WARNING: PHOTOVOLTIC POWER SOURCE Per NEC 690.31(G) (3)(4) Place on all source markings. Place on Conduit every 10 ft. (IFC 605.11.1.1 and IFC 605.11.1.2)WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. PER NEC 705.12(B)(2)(3)(b) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.56(C) WARNING DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM 4" x 2", RED AND WHITE LETTERS PER NEC 705.12(D)(3) & NEC 690.64 ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING PER NEC 690.13 (B) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING PER NEC 705.12(B)(2)(3)(c) Per NEC NEC 690.13(B) PHOTOVOLTIC AC DISCONNECT WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. PER NEC 705.12(B)(2)(3)(b) AC DISCONNECT INVERTER RATED MAXIMUM POWER- . POINT CURRENT (Imp) . RATED MAXIMUM POWER- . POINT VOLTAGE (Vmp) . MAXIMUM SYSTEM . VOLTAGE (VOC) . MAXIMUM CIRCUIT . CURRENT (Isc) . 380 480 30 16.11 A V LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) V A INVERTER #1 CAMBERLEY LN. (E) MAIN SERVICE PANEL (INSIDE GARAGE) (E) UTILITY METER (N) NON FUSED AC DISCONNECT (N) INVERTERS 12/16/21 REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 EQUIPMENT SPECIFICATION 12/16/21 REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 EQUIPMENT SPECIFICATION 12/16/21 REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 EQUIPMENT SPECIFICATION 12/16/21 REV SHEET NAME SHEET SIZE SHEET NUMBERHELMUT SCHWARZIN12361 CAMBERLEY LN.,CARMEL, IN 46033,USAANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 SOLAR ENERGY SOLUTIONS 1038 BRENTWOOD CT, STE B LEXINGTON, KY 40511 TEL: (877) 312-7456 JOB NUMBER 21152 22/11/2021 EQUIPMENT SPECIFICATION 12/16/21