HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN 46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design. Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG172Rev. By Date CommentsDrawn By:DWChecked By: Date:10/21/2021Chelsea
26549
Sheet
1 of 1
Second Floor System
Not to Scale
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. SpacingFraming Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H1 2 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes
H202 1 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - 2 No Yes
H203 5 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No
H204 1 Simpson U14 Designed 14- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes
Products
PlotID Length Product Plies Net Qty
FJ202 22' 0" 11 7/8" TJI 110 joist 2 8
FJ201 22' 0" 11 7/8" TJI 110 joist 1 2
FJ203 18' 0" 11 7/8" TJI 110 joist 1 3
FJ204 16' 0" 11 7/8" TJI 110 joist 1 3
FJ205 12' 0" 11 7/8" TJI 110 joist 1 1
FJ206 10' 0" 11 7/8" TJI 110 joist 1 6
FJ207 4' 0" 11 7/8" TJI 110 joist 1 3
FJ208 36' 0" 11 7/8" TJI 360 joist 1 2
FJ209 26' 0" 11 7/8" TJI 360 joist 1 2
FJ210 18' 0" 11 7/8" TJI 360 joist 1 10
FJ211 16' 0" 11 7/8" TJI 360 joist 1 4
BM201 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2
BM202 20' 0" 1 3/4" x 14" 2.0E Microllam LVL 2 2
BM203 6' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 2
BM204 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 8
BM205 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2
Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 10
Blocking
PlotID Length Product Plies Net Qty
Bk201 2' 0" 11 7/8" TJI 110 joist 1 26
LEVEL NOTES
Current Date: 10/21/2021
File Name: tg172_26549.jvl
Level Name: Second Floor System
Building Code - Design Methodology: IBC 2006
Members with Design Overridden:
TJ-Pro Rating (Weighted Average): 45
Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 33, joist = FJ209(i6109)
Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 65, joist = FJ206(i6077)
FLOOR
Floor Container: FC4
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Operator Added Additional Loads
Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: 45
Directly Applied Ceiling: Gypsum 1/2"
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
CS
B1
B4
B1
A3
A3
A3
A3
A3
A3
H2
H2
H2
H2
H2
H2
B3W
B1
E1
E3
E1
B4 BBO6BBO5
BM204BM202 BM204(4) 2x6 BM201
BBO12 BM203 PBO2 PBO3
VO1
VO2
VO3VO4
BM205 2' 4 1/2"BM204BM204 BBO24FJ206
FJ208
FJ202
FJ202
FJ202
FJ202
FJ208
FJ210
FJ210
FJ210
FJ210
FJ210
FJ210
FJ210
FJ210
FJ210
FJ203
FJ206
FJ204
FJ204
FJ203
FJ210
FJ203
FJ201
FJ201
FJ205
Ca201
Ca201
Ca201
Ca201 Ca201Ca201Ca201Ca201Ca201Ca201Bk201FJ207FJ207FJ209
FJ209
FJ206
Bk201 FJ206
FJ206
FJ206FJ207 H203H203
H203 H202 H203H204 H203
H1
H1
FJ211
FJ211
FJ204
FJ211Bk201FJ2116' 0"1' 0" 2' 0" 1' 0" 9' 0 1/16"2' 0" 5' 2 7/16" 1' 0"2' 0" 1' 0" 1' 0" 2' 0"1' 0" 9 1/8"1' 2 7/8"4 7/8"1' 7 1/8"8 9/16"1' 9"1' 1 1/4"9"Flush beam depth greater than floor joist depth. Verify
all loading and framing conditions prior to construction.An additional 8 PSF area dead load has been added
to account for tile load in the MBA on this floor.
There are different joist series of the same
depth specified on this floor system. Verify
when installing that the proper TJI® joists
are used in the appropriate area.
TJI 560's not used due to stock shortage.Joists moved to avoid 2x6plumbing wall above.12/16/21