Loading...
HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN  46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design.  Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG172Rev. By Date CommentsDrawn By:DWChecked By: Date:10/21/2021Chelsea 26549 Sheet 1 of 1 Second Floor System Not to Scale Confirm this layout with the builder and designer of record.  Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. SpacingFraming Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H1 2 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes H202 1 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - 2 No Yes H203 5 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No H204 1 Simpson U14 Designed 14- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes Products PlotID Length Product Plies Net Qty FJ202 22' 0" 11 7/8" TJI 110 joist 2 8 FJ201 22' 0" 11 7/8" TJI 110 joist 1 2 FJ203 18' 0" 11 7/8" TJI 110 joist 1 3 FJ204 16' 0" 11 7/8" TJI 110 joist 1 3 FJ205 12' 0" 11 7/8" TJI 110 joist 1 1 FJ206 10' 0" 11 7/8" TJI 110 joist 1 6 FJ207 4' 0" 11 7/8" TJI 110 joist 1 3 FJ208 36' 0" 11 7/8" TJI 360 joist 1 2 FJ209 26' 0" 11 7/8" TJI 360 joist 1 2 FJ210 18' 0" 11 7/8" TJI 360 joist 1 10 FJ211 16' 0" 11 7/8" TJI 360 joist 1 4 BM201 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2 BM202 20' 0" 1 3/4" x 14" 2.0E Microllam LVL 2 2 BM203 6' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 2 BM204 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 8 BM205 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 10 Blocking PlotID Length Product Plies Net Qty Bk201 2' 0" 11 7/8" TJI 110 joist 1 26   LEVEL NOTES   Current Date:   10/21/2021   File Name:   tg172_26549.jvl   Level Name:   Second Floor System   Building Code - Design Methodology:   IBC 2006   Members with Design Overridden:   TJ-Pro Rating (Weighted Average):   45         Minimum Level TJ - Pro Rating & Joist:   TJ-Pro rating = 33, joist = FJ209(i6109)         Maximum Level TJ - Pro Rating & Joist:   TJ-Pro rating = 65, joist = FJ206(i6077)   FLOOR   Floor Container:   FC4   Use/Occupancy:   ResidentialLivingAreas   Floor Area Loading is:   40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load   Operator Added Additional Loads   Maximum Allowed Deflection:   L/480 Live Load & L/240 Total Load   TJ-Pro Rating Information:           Weighted Average:   45           Directly Applied Ceiling:   Gypsum 1/2"           Decking Attachment:   Glue and Nail           Decking Material:   23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF           Perpendicular Partition:   No           Strapping at max 8' o.c.:   None           Blocking at max 8' o.c.:   No           Poured Flooring:   No CS B1 B4 B1 A3 A3 A3 A3 A3 A3 H2 H2 H2 H2 H2 H2 B3W B1 E1 E3 E1 B4 BBO6BBO5 BM204BM202 BM204(4) 2x6 BM201 BBO12 BM203 PBO2 PBO3 VO1 VO2 VO3VO4 BM205 2' 4 1/2"BM204BM204 BBO24FJ206 FJ208 FJ202 FJ202 FJ202 FJ202 FJ208 FJ210 FJ210 FJ210 FJ210 FJ210 FJ210 FJ210 FJ210 FJ210 FJ203 FJ206 FJ204 FJ204 FJ203 FJ210 FJ203 FJ201 FJ201 FJ205 Ca201 Ca201 Ca201 Ca201 Ca201Ca201Ca201Ca201Ca201Ca201Bk201FJ207FJ207FJ209 FJ209 FJ206 Bk201 FJ206 FJ206 FJ206FJ207 H203H203 H203 H202 H203H204 H203 H1 H1 FJ211 FJ211 FJ204 FJ211Bk201FJ2116' 0"1' 0" 2' 0" 1' 0" 9' 0 1/16"2' 0" 5' 2 7/16" 1' 0"2' 0" 1' 0" 1' 0" 2' 0"1' 0" 9 1/8"1' 2 7/8"4 7/8"1' 7 1/8"8 9/16"1' 9"1' 1 1/4"9"Flush beam depth greater than floor joist depth. Verify all loading and framing conditions prior to construction.An additional 8 PSF area dead load has been added to account for tile load in the MBA on this floor. There are different joist series of the same depth specified on this floor system.  Verify when installing that the proper TJI® joists are used in the appropriate area. TJI 560's not used due to stock shortage.Joists moved to avoid 2x6plumbing wall above.12/16/21