HomeMy WebLinkAboutM003.016023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. RE: Design Code: IRC2021/TPI2014 Wind Code: ASCE 7-16 Wind Speed: 115 mph Roof Load: 40.0 psf Design Program: MiTek 20/20 8.5 1 of 1 This package includes 23 individual, dated Truss Design Drawings and 0 Additional Drawings. General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Floor Load: N/A psf August 18, 2021 Liu, Xuegang The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision based on the parameters provided by 84 Components - 0783. Truss Design Engineer's Name: Liu, XuegangMy license renewal date for the state of Indiana is July 31, 2022. 26942-26942A TG174 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the designparameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. Site Information: Lot/Block: 174Customer: Pyatt Builders Project Name: 26942-26942A Subdivision: The Grove at LegacyAddress: 14253 Larson Drive State: INCity: Carmel Model: Chelsea No. Seal# Truss Name Date 1 I47508514 A01 8/18/2021 2 I47508515 A02 8/18/2021 3 I47508516 A03 8/18/2021 4 I47508517 A04 8/18/2021 5 I47508518 A05 8/18/2021 6 I47508519 A06 8/18/2021 7 I47508520 B01 8/18/2021 8 I47508521 B02 8/18/2021 9 I47508522 B03 8/18/2021 10 I47508523 C01 8/18/2021 11 I47508524 C02 8/18/2021 12 I47508525 C03 8/18/2021 13 I47508526 C04 8/18/2021 14 I47508527 D01 8/18/2021 15 I47508528 D02 8/18/2021 16 I47508529 M01 8/18/2021 17 I47508530 M02 8/18/2021 18 I47508531 M03 8/18/2021 19 I47508532 M04 8/18/2021 20 I47508533 M05 8/18/2021 No. Seal# Truss Name Date 21 I47508534 V01 8/18/2021 22 I47508535 V02 8/18/2021 23 I47508536 V03 8/18/2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss A01 Truss Type GABLE Qty 1 Ply 1 TG174 Job Reference (optional) I47508514 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:24 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-3bCvIrqsG9YBOVf188RaI1ECVKKl3YTvCWXOyxymeTT Scale = 1:41.3 1 2 3 4 5 6 7 8 9 10 11 12 13 22 21 19 18 17 16 15 14 23 24 25 26 35 36 37 38 20 4x4 3x4 4x4 3x6 4x4 3x6 4x4 5-3-85-3-8 8-8-03-4-8 10-7-01-11-0 17-4-06-9-0 -1-0-0 1-0-0 4-5-12 4-5-12 5-3-8 0-9-12 8-8-0 3-4-8 12-10-4 4-2-4 17-4-0 4-5-12 0-8-06-5-50-8-08.00 12 Plate Offsets (X,Y)-- [2:0-3-1,0-0-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.16 0.16 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.03 0.01 0.02 (loc) 22-33 22-33 27 22-33 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 23 REACTIONS.All bearings 7-0-8 except (jt=length) 2=0-3-8, 20=0-3-8. (lb) - Max Horz 2=120(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 17, 16, 15 except 19=-183(LC 12) Max Grav All reactions 250 lb or less at joint(s) 13, 19, 18, 17, 16, 15, 13 except 2=543(LC 1), 20=279(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-515/42 BOT CHORD 2-22=-45/438, 20-22=-45/438, 19-20=-45/438 WEBS 4-25=-389/122, 24-25=-352/99, 23-24=-381/117, 23-26=-364/104, 19-26=-377/111 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-8-0, Exterior(2R) 5-8-0 to 11-8-0, Interior(1) 11-8-0 to 14-4-0, Exterior(2E) 14-4-0 to 17-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 17, 16, 15 except (jt=lb) 19=183. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss A02 Truss Type COMMON Qty 12 Ply 1 TG174 Job Reference (optional) I47508515 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:26 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-?_KgjXs7onovdopQGZU2NSJY48xOXQqCfq0V0qymeTR Scale = 1:40.3 1 2 3 4 5 6 7 8 9 18 19 20 21 4x6 4x4 4x6 4x4 5x9 4x4 1.5x4 1.5x4 8-8-08-8-0 17-4-08-8-0 -1-0-0 1-0-0 4-4-0 4-4-0 8-8-0 4-4-0 13-0-0 4-4-0 17-4-0 4-4-0 0-8-06-5-50-8-08.00 12 Plate Offsets (X,Y)-- [2:0-2-13,0-0-3], [8:0-2-8,0-1-11], [9:0-4-8,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.16 0.41 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.15 0.01 0.01 (loc) 9-12 9-12 8 9-12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=Mechanical, 2=0-3-8 Max Horz 2=120(LC 11) Max Uplift 8=-43(LC 13), 2=-61(LC 12) Max Grav 8=692(LC 1), 2=755(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-886/105, 4-5=-698/92, 5-6=-699/93, 6-8=-851/107 BOT CHORD 2-9=-93/703, 8-9=-41/708 WEBS 5-9=-4/477, 6-9=-253/135 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-8-0, Exterior(2R) 5-8-0 to 11-8-0, Interior(1) 11-8-0 to 14-4-0, Exterior(2E) 14-4-0 to 17-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss A03 Truss Type COMMON Qty 10 Ply 1 TG174 Job Reference (optional) I47508516 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:27 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-TAt2xttlZ4wmFyOcqH?HwfsjsYHfGu8LuUm3YGymeTQ Scale = 1:38.6 1 2 3 4 5 6 7 8 9 10 19 20 21 22 4x6 4x4 5x9 4x4 1.5x4 1.5x4 4x6 4x4 8-8-08-8-0 17-4-08-8-0 -1-0-0 1-0-0 4-4-0 4-4-0 8-8-0 4-4-0 13-0-0 4-4-0 17-4-0 4-4-0 18-4-0 1-0-0 0-8-06-5-50-8-08.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-0-3], [8:0-2-13,0-0-3], [10:0-4-8,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.16 0.40 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.14 0.01 0.01 (loc) 10-17 10-17 8 10-13 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 69 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-125(LC 10) Max Uplift 2=-61(LC 12), 8=-61(LC 13) Max Grav 2=753(LC 1), 8=753(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-851/103, 4-5=-695/90, 5-6=-695/90, 6-8=-851/103 BOT CHORD 2-10=-85/706, 8-10=-13/700 WEBS 5-10=-1/475 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-8-0, Exterior(2R) 5-8-0 to 11-8-0, Interior(1) 11-8-0 to 15-4-0, Exterior(2E) 15-4-0 to 18-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss A04 Truss Type COMMON Qty 1 Ply 1 TG174 Job Reference (optional) I47508517 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:28 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-xMRQ8DtNJO2ds6zpN_WWTtPuZyds?KJV78Vc5iymeTP Scale = 1:40.3 1 2 3 4 5 6 7 8 9 18 19 20 21 4x6 4x4 4x6 4x4 5x9 4x4 1.5x4 1.5x4 8-8-08-8-0 17-4-08-8-0 -1-0-0 1-0-0 4-4-0 4-4-0 8-8-0 4-4-0 13-0-0 4-4-0 17-4-0 4-4-0 0-8-06-5-50-8-08.00 12 Plate Offsets (X,Y)-- [2:0-2-13,0-0-3], [8:0-2-8,0-1-11], [9:0-4-8,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.16 0.41 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.15 0.01 0.01 (loc) 9-12 9-12 8 9-12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 2=0-3-8 Max Horz 2=120(LC 11) Max Uplift 8=-43(LC 13), 2=-61(LC 12) Max Grav 8=692(LC 1), 2=755(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-886/105, 4-5=-698/92, 5-6=-699/93, 6-8=-851/107 BOT CHORD 2-9=-93/703, 8-9=-41/708 WEBS 5-9=-4/477, 6-9=-253/135 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-8-0, Exterior(2R) 5-8-0 to 11-8-0, Interior(1) 11-8-0 to 14-4-0, Exterior(2E) 14-4-0 to 17-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss A05 Truss Type ROOF SPECIAL Qty 2 Ply 1 TG174 Job Reference (optional) I47508518 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:29 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-QZ?oLZu?4iAUUGY?xi1l?4x1jL0ukk3eLoF9d9ymeTO Scale = 1:38.3 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 25 26 27 28 5x6 3x4 4x4 3x6 4x4 1.5x4 1.5x4 1.5x4 1.5x4 4x6 4x4 6x8 4x4 6x10 4x6 4-4-04-4-0 6-6-02-2-0 12-9-06-3-0 14-10-122-1-12 17-4-02-5-4 -1-0-0 1-0-0 4-4-0 4-4-0 6-6-0 2-2-0 8-8-0 2-2-0 12-9-0 4-1-0 14-10-12 2-1-12 17-4-0 2-5-4 0-8-06-5-50-8-02-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-1,0-0-3], [13:0-3-4,0-3-12], [14:0-2-8,0-3-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.26 0.23 0.35 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.08 -0.17 0.11 0.05 (loc) 13-14 13-14 10 13 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 92 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* 5-15,7-12: 2x4 SPF No.2, 13-14: 2x6 SP DSS WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 4-7-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 15-16. REACTIONS. (size)10=Mechanical, 2=0-3-8 Max Horz 2=120(LC 11) Max Uplift 10=-43(LC 13), 2=-61(LC 12) Max Grav 10=692(LC 1), 2=755(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-901/80, 4-5=-1368/117, 5-6=-1350/153, 6-7=-2177/197, 7-8=-2161/127, 8-10=-905/73 BOT CHORD 2-16=-75/700, 13-14=-1/728, 10-11=-32/712 WEBS 4-16=-668/96, 14-16=-96/993, 4-14=0/460, 6-14=-96/789, 6-13=-123/1442, 11-13=-33/932, 8-13=-21/1071, 8-11=-695/49 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-8-0, Exterior(2R) 5-8-0 to 11-8-0, Interior(1) 11-8-0 to 14-4-0, Exterior(2E) 14-4-0 to 17-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 2. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss A06 Truss Type GABLE Qty 1 Ply 1 TG174 Job Reference (optional) I47508519 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:30 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-ulZAZvvdr?IK6Q6BVPY_YIUFvlPFTFfoaS_j9bymeTN Scale = 1:40.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 3x6 4x4 3x6 5x6 17-4-017-4-0 -1-0-0 1-0-0 8-8-0 8-8-0 17-4-0 8-8-0 0-8-06-5-50-8-08.00 12 Plate Offsets (X,Y)-- [24:0-3-0,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.03 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 1 1 17 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 17-4-0. (lb) - Max Horz 31=132(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 31, 17, 25, 26, 27, 28, 29, 30, 23, 22, 21, 20, 19, 18 Max Grav All reactions 250 lb or less at joint(s) 31, 17, 24, 25, 26, 27, 28, 29, 30, 23, 22, 21, 20, 19, 18 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-8-0, Corner(3R) 5-8-0 to 11-8-0, Exterior(2N) 11-8-0 to 14-0-0, Corner(3E) 14-0-0 to 17-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 31, 17, 25, 26, 27, 28, 29, 30, 23, 22, 21, 20, 19, 18. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss B01 Truss Type GABLE Qty 1 Ply 1 TG174 Job Reference (optional) I47508520 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:32 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-q8hx_awtNdY2LjGacqaSdjZbCZ4Wx9c52mTpETymeTL Scale = 1:35.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 26 25 24 23 22 21 20 19 18 17 16 3x6 4x4 8x8 14-9-014-9-0 -1-0-0 1-0-0 7-4-8 7-4-8 14-9-0 7-4-8 15-9-0 1-0-0 0-8-05-7-00-8-08.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.12 0.04 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 15 15 14 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Right 2x4 SPF No.2 0-8-4 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-9-0. (lb) - Max Horz 26=-117(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 26, 14, 21, 22, 23, 24, 25, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 26, 14, 20, 21, 22, 23, 24, 25, 19, 18, 17, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-8, Exterior(2N) 2-0-8 to 4-4-8, Corner(3R) 4-4-8 to 10-4-8, Exterior(2N) 10-4-8 to 12-8-8, Corner(3E) 12-8-8 to 15-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 14, 21, 22, 23, 24, 25, 19, 18, 17, 16. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss B02 Truss Type COMMON Qty 1 Ply 1 TG174 Job Reference (optional) I47508521 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:33 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-IKFJBwxW8wgvztrmAX6hAw6gYzJAgb6EGQDNmwymeTK Scale = 1:35.6 1 2 3 4 5 6 7 8 17 18 19 20 3x6 4x4 3x6 4x4 1.5x4 4x6 7-4-87-4-8 14-9-07-4-8 -1-0-0 1-0-0 7-4-8 7-4-8 14-9-0 7-4-8 15-9-0 1-0-0 0-8-05-7-00-8-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-0-3], [6:0-3-5,0-0-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.46 0.46 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.15 0.03 0.08 (loc) 8-15 8-15 2 8-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 49 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=108(LC 11) Max Uplift 2=-54(LC 12), 6=-54(LC 13) Max Grav 2=735(LC 20), 6=735(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-766/99, 4-6=-766/99 BOT CHORD 2-8=0/596, 6-8=0/596 WEBS 4-8=0/409 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-4-8, Exterior(2R) 4-4-8 to 10-4-8, Interior(1) 10-4-8 to 12-9-0, Exterior(2E) 12-9-0 to 15-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss B03 Truss Type Common Girder Qty 1 Ply 2 TG174 Job Reference (optional) I47508522 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:42 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-X3Hj4?290hpdYG1VCwmo1q_DobN0Hc?ZLJuLauymeTB Scale = 1:35.2 1 2 3 4 11 12 13 14 15 16 17 18 19 8x8 8x8 4x6 4x4 JUS24 JUS24 JUS24 JUS24 JUS24 JUS24 JUS24 7-4-87-4-8 14-9-07-4-8 7-4-8 7-4-8 14-9-0 7-4-8 0-8-05-7-00-8-08.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-3-13], [3:0-0-0,0-3-13], [4:0-4-8,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.43 0.54 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.14 0.01 0.05 (loc) 4-7 4-7 1 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 124 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=0-3-8 Max Horz 1=-95(LC 35) Max Uplift 1=-245(LC 12), 3=-211(LC 13) Max Grav 1=3164(LC 1), 3=2723(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3244/311, 2-3=-3246/311 BOT CHORD 1-4=-177/2604, 3-4=-177/2604 WEBS 2-4=-186/3030 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-4-8, Exterior(2R) 4-4-8 to 10-4-8, Interior(1) 10-4-8 to 11-9-0, Exterior(2E) 11-9-0 to 14-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=245, 3=211. 9) Use MiTek JUS24 (With 4-10d nails into Girder & 2-10d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 0-8-4 from the left end to 12-8-4 to connect truss(es) to back face of bottom chord. 10) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard Continued on page 2 August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss B03 Truss Type Common Girder Qty 1 Ply 2 TG174 Job Reference (optional) I47508522 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:43 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-?Fr5HL3nn?xUAPchmeH1Z1WOY?jF03FiZzev7LymeTA LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 5-8=-20 Concentrated Loads (lb) Vert: 13=-675(B) 14=-672(B) 15=-672(B) 16=-672(B) 17=-672(B) 18=-672(B) 19=-672(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss C01 Truss Type GABLE Qty 1 Ply 1 TG174 Job Reference (optional) I47508523 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:44 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-TRPTVh4PYJ3LnZBtJLoG6F3eDOBKlbbsodNSfnymeT9 Scale = 1:35.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 26 25 24 23 22 21 20 19 18 17 16 3x6 4x4 8x8 14-8-014-8-0 -1-0-0 1-0-0 7-4-0 7-4-0 14-8-0 7-4-0 15-8-0 1-0-0 0-8-05-6-110-8-08.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.11 0.04 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 15 15 14 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 73 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Right 2x4 SPF No.2 0-7-11 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-8-0. (lb) - Max Horz 26=-116(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 26, 14, 21, 22, 23, 24, 25, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 26, 14, 20, 21, 22, 23, 24, 25, 19, 18, 17, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 4-4-0, Corner(3R) 4-4-0 to 10-4-0, Exterior(2N) 10-4-0 to 12-8-0, Corner(3E) 12-8-0 to 15-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 14, 21, 22, 23, 24, 25, 19, 18, 17, 16. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss C02 Truss Type COMMON Qty 8 Ply 1 TG174 Job Reference (optional) I47508524 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:45 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-yezri151JcBCPjm4t3JVfScjcoRmU1O?1H7?BDymeT8 Scale = 1:35.4 1 2 3 4 5 6 7 8 17 18 4x6 4x4 4x6 4x4 1.5x4 4x6 7-4-07-4-0 14-8-07-4-0 -1-0-0 1-0-0 7-4-0 7-4-0 14-8-0 7-4-0 15-8-0 1-0-0 0-8-05-6-110-8-08.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-0-7], [6:0-3-1,0-0-7] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.46 0.35 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.08 -0.14 0.03 0.07 (loc) 8-15 8-15 2 8-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 49 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=-108(LC 10) Max Uplift 2=-54(LC 12), 6=-54(LC 13) Max Grav 2=647(LC 1), 6=647(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-662/99, 4-6=-662/99 BOT CHORD 2-8=0/470, 6-8=0/470 WEBS 4-8=0/330 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-4-0, Exterior(2R) 4-4-0 to 10-4-0, Interior(1) 10-4-0 to 12-8-0, Exterior(2E) 12-8-0 to 15-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss C03 Truss Type Common Qty 1 Ply 1 TG174 Job Reference (optional) I47508525 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:46 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-QqXEwN5f4wJ31tLGRmrkBg8uCCnqDUe8GxsZjgymeT7 Scale = 1:35.0 1 2 3 4 5 6 15 16 3x6 4x4 3x6 4x4 1.5x4 4x6 7-4-07-4-0 14-8-07-4-0 7-4-0 7-4-0 14-8-0 7-4-0 0-8-05-6-110-8-08.00 12 Plate Offsets (X,Y)-- [1:0-3-8,Edge], [5:0-3-13,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.47 0.36 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.15 0.03 0.08 (loc) 6-13 6-13 1 6-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 5=0-3-8 Max Horz 1=-95(LC 10) Max Uplift 1=-36(LC 12), 5=-36(LC 13) Max Grav 1=587(LC 1), 5=587(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-670/104, 3-5=-670/104 BOT CHORD 1-6=-6/478, 5-6=-6/478 WEBS 3-6=0/332 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-4-0, Exterior(2R) 4-4-0 to 10-4-0, Interior(1) 10-4-0 to 11-8-0, Exterior(2E) 11-8-0 to 14-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss C04 Truss Type Common Girder Qty 1 Ply 2 TG174 Job Reference (optional) I47508526 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:47 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-u05c7j6IrERwe1wS?UMzkth4jc5gytDIUbc6G6ymeT6 Scale = 1:35.0 1 2 3 4 11 12 13 14 15 16 17 18 6x6 6x6 4x6 4x6 JUS24 JUS24 JUS24 JUS24 JUS24 JUS24 JUS24 7-4-07-4-0 14-8-07-4-0 7-4-0 7-4-0 14-8-0 7-4-0 0-8-05-6-110-8-08.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-2-6], [3:Edge,0-2-6], [4:0-4-8,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.42 0.51 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.14 0.01 0.05 (loc) 4-10 4-10 1 4-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 123 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=0-3-8 Max Horz 1=95(LC 38) Max Uplift 1=-231(LC 12), 3=-226(LC 13) Max Grav 1=2967(LC 1), 3=2910(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3252/312, 2-3=-3252/312 BOT CHORD 1-4=-178/2611, 3-4=-178/2611 WEBS 2-4=-187/3039 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-4-0, Exterior(2R) 4-4-0 to 10-4-0, Interior(1) 10-4-0 to 11-8-0, Exterior(2E) 11-8-0 to 14-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=231, 3=226. 9) Use MiTek JUS24 (With 4-10d nails into Girder & 2-10d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 1-2-12 from the left end to 13-2-12 to connect truss(es) to back face of bottom chord. 10) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard Continued on page 2 August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss C04 Truss Type Common Girder Qty 1 Ply 2 TG174 Job Reference (optional) I47508526 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:47 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-u05c7j6IrERwe1wS?UMzkth4jc5gytDIUbc6G6ymeT6 LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 5-8=-20 Concentrated Loads (lb) Vert: 4=-672(B) 13=-672(B) 14=-672(B) 15=-672(B) 16=-672(B) 17=-672(B) 18=-672(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss D01 Truss Type GABLE Qty 1 Ply 1 TG174 Job Reference (optional) I47508527 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:48 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-MDf_L37wcXZnGBUfYBtCG5EJu0YchPPRjFLgoYymeT5 Scale = 1:26.8 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 3x6 4x4 3x6 4x8 10-7-010-7-0 -1-0-0 1-0-0 5-3-8 5-3-8 10-7-0 5-3-8 11-7-0 1-0-0 0-8-04-2-50-8-08.00 12 Plate Offsets (X,Y)-- [10:0-2-8,0-2-11] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.13 0.02 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 11 11 10 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Right 2x4 SPF No.2 1-4-11 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-7-0. (lb) - Max Horz 19=-89(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 19, 10, 15, 16, 17, 18, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 19, 10, 15, 16, 17, 18, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Corner(3R) 2-0-0 to 8-7-0, Corner(3E) 8-7-0 to 11-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 10, 15, 16, 17, 18, 14, 13, 12. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss D02 Truss Type COMMON Qty 1 Ply 1 TG174 Job Reference (optional) I47508528 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:49 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-qPCMYP8YNrheuK3r6vORpImSzPq5Qsibyv5DK_ymeT4 Scale = 1:27.0 1 2 3 4 5 6 7 8 17 18 3x6 4x4 3x6 4x4 1.5x4 4x4 5-3-85-3-8 10-7-05-3-8 -1-0-0 1-0-0 5-3-8 5-3-8 10-7-0 5-3-8 11-7-0 1-0-0 0-8-04-2-50-8-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-0-3], [6:0-3-5,0-0-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.31 0.26 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.04 0.01 0.03 (loc) 8-15 8-15 2 8-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 37 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=81(LC 11) Max Uplift 2=-44(LC 12), 6=-44(LC 13) Max Grav 2=483(LC 1), 6=483(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-413/94, 4-6=-413/94 BOT CHORD 2-8=0/308, 6-8=0/308 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 8-7-0, Exterior(2E) 8-7-0 to 11-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss M01 Truss Type GABLE Qty 1 Ply 1 TG174 Job Reference (optional) I47508529 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:50 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-Ibmklk8A89pVVUe1gcvgMWJf7pDH9IBkAZqmsRymeT3 Scale = 1:14.9 1 2 3 4 5 8 7 6 9 1.5x4 1.5x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 -1-0-0 1-0-0 5-11-8 5-11-8 0-4-02-3-134.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.07 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-11-8. (lb) - Max Horz 2=70(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 6, 2, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7 except 8=343(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-8=-274/220 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 2-9-12, Corner(3E) 2-9-12 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2, 7, 8. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss M02 Truss Type MONOPITCH Qty 17 Ply 1 TG174 Job Reference (optional) I47508530 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:50 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-Ibmklk8A89pVVUe1gcvgMWJYyp779InkAZqmsRymeT3 Scale = 1:14.9 1 2 3 4 8 9 10 1.5x4 3x6 1.5x4 5-11-85-11-8 -1-0-0 1-0-0 5-11-8 5-11-8 0-4-02-3-132-0-50-3-82-3-134.00 12 Plate Offsets (X,Y)-- [2:0-1-9,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.61 0.46 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.15 0.00 0.06 (loc) 4-7 4-7 2 4-7 l/defl >788 >452 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 4=0-1-8 Max Horz 2=70(LC 13) Max Uplift 2=-59(LC 10), 4=-32(LC 14) Max Grav 2=390(LC 21), 4=306(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-9-12, Exterior(2E) 2-9-12 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss M03 Truss Type GABLE Qty 1 Ply 1 TG174 Job Reference (optional) I47508531 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:51 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-mnK7z49ovSxM7eDDEJQvujrqtDYWulRuPDaKPtymeT2 Scale = 1:14.9 1 2 3 4 5 8 7 6 9 1.5x4 1.5x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 -1-0-0 1-0-0 5-11-8 5-11-8 0-4-02-3-134.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.07 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-11-8. (lb) - Max Horz 2=70(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 6, 2, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7 except 8=343(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-8=-274/220 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 2-9-12, Corner(3E) 2-9-12 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2, 7, 8. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss M04 Truss Type GABLE Qty 1 Ply 1 TG174 Job Reference (optional) I47508532 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:52 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-E_uVAQAQgm4DlooQn1x8RxO?udvOdC51etJtxJymeT1 Scale = 1:14.1 1 2 3 4 7 6 5 3x6 1.5x4 1.5x4 1.5x4 1.5x4 -1-0-0 1-0-0 2-4-0 2-4-0 0-8-02-2-118.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.03 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 2-4-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)7=2-4-0, 5=2-4-0, 6=2-4-0 Max Horz 7=63(LC 9) Max Uplift 7=-14(LC 8), 5=-9(LC 9), 6=-45(LC 18) Max Grav 7=214(LC 18), 5=49(LC 20), 6=60(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5, 6. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss M05 Truss Type MONOPITCH Qty 5 Ply 1 TG174 Job Reference (optional) I47508533 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:52 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-E_uVAQAQgm4DlooQn1x8RxO0NdvJdCH1etJtxJymeT1 Scale = 1:14.1 1 2 3 4 5 1.5x4 3x6 3x4 1.5x4 -1-0-0 1-0-0 2-4-0 2-4-0 0-8-02-2-111-11-30-3-82-2-118.00 12 Plate Offsets (X,Y)-- [2:0-3-1,0-0-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.10 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in 0.00 -0.00 0.00 0.00 (loc) 8 8 2 8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 2-4-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 5=0-1-8 Max Horz 2=59(LC 11) Max Uplift 2=-21(LC 12), 5=-18(LC 12) Max Grav 2=167(LC 18), 5=83(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss V01 Truss Type Valley Qty 2 Ply 1 TG174 Job Reference (optional) I47508534 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:53 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-jAStOmB3R4C4MyNcLkTNz8xCD1EbMfXAtX3RTmymeT0 Scale = 1:9.4 1 2 3 3x4 3x4 3x4 0-0-60-0-6 4-0-03-11-10 2-0-0 2-0-0 4-0-0 2-0-0 0-0-41-4-00-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.03 0.09 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-11-4, 3=3-11-4 Max Horz 1=-20(LC 10) Max Uplift 1=-8(LC 12), 3=-8(LC 13) Max Grav 1=121(LC 1), 3=121(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss V02 Truss Type Valley Qty 2 Ply 1 TG174 Job Reference (optional) I47508535 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:54 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-BM0Fb6ChCNKx_6yovS_cWMTJHQae56MK5Bo_?CymeT? Scale = 1:18.3 1 2 3 4 3x4 4x4 3x4 1.5x4 0-0-60-0-6 8-0-07-11-10 4-0-0 4-0-0 8-0-0 4-0-0 0-0-42-8-00-0-48.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.21 0.11 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-11-4, 3=7-11-4, 4=7-11-4 Max Horz 1=45(LC 11) Max Uplift 1=-25(LC 12), 3=-31(LC 13) Max Grav 1=151(LC 1), 3=151(LC 1), 4=261(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 4-6-4, Exterior(2E) 4-6-4 to 7-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26942-26942A Truss V03 Truss Type Valley Qty 2 Ply 1 TG174 Job Reference (optional) I47508536 8.510 s Jun 18 2021 MiTek Industries, Inc. Wed Aug 18 10:26:54 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-BM0Fb6ChCNKx_6yovS_cWMTEzQXG55iK5Bo_?CymeT? Scale = 1:25.7 1 2 3 4 5 6 3x4 4x4 3x4 1.5x4 0-0-60-0-6 12-0-011-11-10 6-0-0 6-0-0 12-0-0 6-0-0 0-0-44-0-00-0-48.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.55 0.26 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=11-11-4, 3=11-11-4, 4=11-11-4 Max Horz 1=-71(LC 8) Max Uplift 1=-39(LC 12), 3=-48(LC 13) Max Grav 1=236(LC 1), 3=236(LC 1), 4=410(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-272/87 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 8-6-4, Exterior(2E) 8-6-4 to 11-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. August 18,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths