HomeMy WebLinkAboutRobFisher_Plans_11202021_V0SS619bd72a0d757COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 4811 PENDULA DR, CARMEL, IN 46033 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-0 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com 45 MODULES-ROOF MOUNTED - 16.65 kWDC, 13.05 kWAC AERIAL VIEW SCALE: NTS VICINITY MAP SCALE: NTS FRONT VIEW SCALE: NTS ARRAY LOCATION PROJECT SITE GOVERNING CODES: SYSTEM SUMMARY PV MODULE MFG:LG SOLAR PV MODULE MODEL:LG370N1K-A6 PV MODULE QTY:45 SYSTEM SIZE (DC):16.65 SYSTEM SIZE (AC):290 INVERTER MFG:ENPHASE ENERGY INVERTER MODEL:IQ8PLUS-72-2-US INVERTER QTY:45 RACKING:UNIRAC ATTACHMENT:UNIRAC FLASHLOC COMP KIT ATTACHMENT GROUNDING:ILSCO LAY-IN LUG (GBL4DBT) SHEET INDEX PV-0 COVER SHEET PV-1 SITE PLAN WITH ROOF PLAN PV-2 ROOF PLAN WITH MODULES PV-3 ATTACHMENT DETAILS PV-4 BRANCH LAYOUT PV-5 ELECTRICAL LINE DIAGRAM PV-6 ELECTRICAL CALCULATION PV-7 WARNING LABELS PV-8+ SPECIFICATION SHEETS PROJECT INFORMATION OWNER: ROB FISHER ADDRESS:4811 PENDULA DR, CARMEL, IN 46033 COUNTY: HAMILTON COUNTY APN: 291404106006000018 COORDINATES: 39.952538, -86.088042 MAX, MIN TEMP: 32°, -22° FINANCING N/A GENERAL NOTES: 1. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODES. 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. 3. PRIOR TO COMMENCEMENT OF WORK CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY DBM OF ANY INCONSISTENCIES. 4. ALL EQUIPMENT SHALL BE INSTALLED AS SHOWN. 5. WARNINGS PER NEC 690 AND IBC 2012. 6. WIRING SHALL NOT BE INSTALLED WITHIN 10 INCHES OF ROOF DECKING EXCEPT WHERE DIRECTLY BELOW PV EQUIPMENT. 2009 - INDIANA ELECTRIC CODE = 2008 NATIONAL ELECTRIC CODE + INDIANA AMENDMENTS 2012 - INTERNATIONAL BUILDING CODE 2012 - INTERNATIONAL FUEL GAS CODE 2012 - INTERNATIONAL FIRE CODE 2012 - INTERNATIONAL MECHANICAL CODE 2006 - INTERNATIONAL PLUMBING CODE ROOF TYPE: - COMP SHINGLE NUMBER OF LAYERS: - 01 ROOF FRAME: - 2"X4" RAFTERS @24" O.C. STORY: - TWO STORY SNOW LOAD : - 20 PSF WIND SPEED :- 115 MPH WIND EXPOSURE:- C EXPOSURE CATEGORY:- II DESIGN CRITERIA: 22-NOV-2021 12/20/21 MS PUMACD CB JB 92'-6"2 9 ' - 8 "47'-8"2 6 ' -0 " ~144.49' ~119.25'~129.27'~129.47' ~ 4 6 . 4 6 'MSPUMA C D C B JB SITE PLAN WITH ROOF PLAN REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-1 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SITE PLAN WITH ROOF PLAN 1 SCALE: 1/16" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ROOF #1 (45) LG SOLAR LG370N1K-A6 (370W) MODULES ENLARGE VIEW1ASCALE: NTS PROPERTY LINEPROPERTY LINEPROPERTY LINE PROPE R T Y LINE PROPERTY L I NE(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (E) UTILITY METER (N) 100A NON FUSED AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 3 (N) JUNCTION BOX (N) 3/4" OR GREATER EMT CONDUIT RUN (1/2 INCHES ABOVE ROOF) (ALONG THE ROOF EDGE) (E) FENCE (E) GATE (E) TREE (TYP.) ROOF ACCESS POINT TWO- STORY HOUSE P E N D U L A D R EXISTING DRIVEWAY SEE ENLARGE VIEW 22-NOV-2021 12/20/21 MS PUM A C D C B JB 11 " 60 ' -6 " 11'-4"1'-0" 17'-4"1'-6"REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-2 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com ROOF PLAN WITH MODULES ROOF PLAN WITH MODULES SCALE: 3/32" = 1'-0"1 68.50"41.02"PHOTOVOLTAIC MODULES LG SOLAR LG370N1K-A6 (370W) MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 45 MODULES MODULE TYPE = LG SOLAR LG370N1K-A6 (370W) MODULES MODULE WEIGHT = 41.00 LBS / 18.6 KG. MODULE DIMENSIONS = 68.50"X 41.02" = 19.51 SF UNIT WEIGHT OF ARRAY = 2.10 PSF ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 45 878.08 1533.93 57.24 ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 37° 220° 2"x4" 24" O.C. LEGEND - UTILITY METER MSP - MAIN SERVICE PANEL - AC DISCONNECT - JUNCTION BOX - COMBINER BOX - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT - FIRE PATHWAY - CHIMNEY UM ACD CB JB BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION RAIL 23 UNIRAC SM STANDARD RAIL 168" DARK SPLICE 14 BND SPLICE BAR PRO SERIES DRK MID CLAMP 74 UNIVERSAL AF SERIES MID CLAMP END CLAMP 32 UNIVERSAL AF SERIES END CLAMP ATTACHMENT 72 UNIRAC FLASHLOC COMP KIT ATTACHMENT GROUNDING LUG 08 ILSCO LAY-IN LUG (GBL4DBT) · PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. ALL ELECTRICAL EQUIPMENT, INVERTERS, DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS SUPPLY OR DEMAND PIPING. NOTE: NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS 18 " FI R E P A T H W A Y 18" F I R E P A T HW A Y 18 " FI R E P A T H W A Y 18 " FI R E P A T H W A Y 36" FIRE PATHWAY36" FIRE P ATHWAY (N) 100A NON FUSED AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 3 (N) 3/4" OR GREATER EMT CONDUIT RUN (1/2 INCHES ABOVE ROOF) (ALONG THE ROOF EDGE) (E) UTILITY METER (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (N) JUNCTION BOX ROOF #1 (45) LG SOLAR LG370N1K-A6 (370W) MODULES (E) COMP SHINGLE ROOF (TYP.) (N) (72) UNIRAC FLASHLOC COMP KIT ATTACHMENT SPACED AT 72" O.C. (N) UNIRAC SM STANDARD RAIL (E) 2"X4" RAFTERS @ 24" O.C. (TYP.) R O O F # 1 TI L T - 37 ° A Z I M U T H - 22 0 ° P E N D U L A DR FR O N T Y AR D RE AR Y AR D (E) CHIMNEY 22-NOV-2021 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-3 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com ATTACHMENT DETAIL ATTACHMENT DETAIL SCALE: NTS1 ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTS 2 NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS SS SERRATED FLANGE NUT PV MODULE FLASHLOC BASE MILL OR DARK SS SERRATED T-BOLT UNIRAC SM STANDARD RAIL PV MODULE SEE ENLARGED VIEW 2.5" MIN. EMBED. 2"x4" RAFTERS @ 24" O.C. ROOF / DECK MEMBRANE COMP SHINGLE ROOF 5/16" X 4" SS LAG BOLT W/ SS EPDM BONDED WASHER, 2.5" MIN. EMBEDMENT. COMP SHINGLE ROOF END / MID CLAMP 22-NOV-2021 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-4 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com BRANCH LAYOUT SCALE: 3/32" = 1'-0"1 BRANCH LAYOUT (45) LG SOLAR LG370N1K-A6 (370W) MODULES (45) ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS (03) BRANCHES OF 12 MODULES & (01) BRANCH OF 09 MODULES CONNECTED IN PARALLEL PER BRANCH 18 " F IR E P A T H W A Y 18 " FI R E P A T HW A Y 18 " F IR E P A T H W A Y 18" F I R E P A T H W A Y 36" FIRE PATH W AY36" FIRE PATHW AY ROOF #1 (45) LG SOLAR LG370N1K-A6 (370W) MODULES P E N D U L A DR FR O N T Y AR D RE AR Y AR D (45) ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS BRANCH #1 BRANCH #2 BRANCH #3 BRANCH #4 68.50"41.02"PHOTOVOLTAIC MODULES LG SOLAR LG370N1K-A6 (370W)3'-0"36" FIRE PATHWAY 18"18" FIRE PATHWAY 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-5 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com ELECTRICAL LINE DIAGRAM ELECTRICAL LINE DIAGRAM SCALE: NTS1 UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: AES INDIANA 240V N/A (E ) 200 A ( E ) 200 A SOUTH-WEST SERVICE INFO. UNDERGROUND (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (TOP FED) L EXISTING GROUNDING SYSTEM SUPPLY SIDE TAP 200A BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) 12 MICRO-INVERTERS IN BRANCH CIRCUIT #2 12 MICRO-INVERTERS IN BRANCH CIRCUIT #1 G (8) #10 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 3/4" EMT CONDUIT RUN (N) JUNCTION BOX G ENVOY (N) ENPHASE IQ COMBINER BOX 3 MICRO-INVERTERS 12 MICRO-INVERTERS IN BRANCH CIRCUIT #3 09 MICRO-INVERTERS IN BRANCH CIRCUIT #4 (4) Q-CABLE (1) PV #6 BARE CU GND 45 MODULES X 1.21A= 54.45 A 54.45A X 1.25 = 68.06 A (3) #4 AWG THWN (1) #8 AWG THWN GND IN 1" EMT CONDUIT RUN G (N) AC DISCONNECT 100A NON FUSED,WITH 70A FUSES 240 VAC 70A FUSES SYSTEM SIZE:- 45 x 370W = 16.65 kWDC SYSTEM SIZE:- 45 x 290VA = 13.05 kWAC BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 45 LG SOLAR LG370N1K-A6 (370W) MODULES INVERTER 45 ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS JUNCTION BOX 1 600V, 55A MAX, 4 INPUTS, MOUNTED ON ROOF FOR WIRE & CONDUIT TRANSITION COMBINER BOX 1 ENPHASE IQ COMBINER BOX 3 AC DISCONNECT 1 AC DISCONNECT 100A NON FUSED,WITH 70A FUSES, 240 VAC (45) LG SOLAR LG370N1K-A6 (370W) MODULES (45) ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS (03) BRANCHES OF 12 MODULES & (01) BRANCH OF 09 MODULES CONNECTED IN PARALLEL PER BRANCH VOLTAGE DROP CALCULATIONS WIRE RUN # OF MODS V (VOLTS) I (AMPS) L (FT) VD** VD (%) WIRE SIZE* RACEWAY BRANCH #1 (MODULE) TO JUNCTION BOX 12 240 14.52 42 1.94 0.81% 12 AWG FREE AIR JUNCTION BOX TO IQ COMBINER BOX BRANCH #1 12 240 14.52 30 0.87 0.36% 10 AWG 3/4" EMT CONDUIT IQ COMBINER BOX TO AC DISCONNECT 45 240 54.45 5 0.14 0.06% 4 AWG 1" EMT CONDUIT AC DISCONNECT TO INTERCONNECTION 45 240 54.45 5 0.14 0.06% 4 AWG 1" EMT CONDUIT MAX VOLTAGE DROP: 1.29% 10A 20A 20A 20A 20A 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-6 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com ELECTRICAL CALCULATION SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #LG SOLAR LG370N1K-A6 (370W)MODULES VMP 35.5 IMP 10.43 VOC 41.9 ISC 10.96 MODULE DIMENSION 68.50"L x 41.02"W x 1.57"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL # ENPHASE ENERGY IQ8PLUS-72-2-US NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 1.21A AMBIENT TEMPERATURE SPECS WEATHER STATION: INDIANAPOLIS INTL AP RECORD LOW TEMP -22° AMBIENT TEMP (HIGH TEMP 2%) 32° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 54° CONDUCTOR TEMPERATURE RATE (ON ROOF) 90° CONDUCTOR TEMPERATURE RATE (OFF ROOF) 75° MODULE TEMPERATURE COEFFICIENT OF Voc -0.26%/°C PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE AC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO COMBINER BOX: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(3)(c): + 22° EXPECTED WIRE TEMP (°C): 32°+ 22°= 54° TEMP CORRECTION PER TABLE 310.15(B)(2)(a): 0.76 # OF CURRENT CARRYING CONDUCTORS: 8 CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a): 0.70 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): 1.25 X # MICRO-INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUT CURRENT 1.25 X 12 X 1.21A = 18.15A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15(B)(2)(a) TEMP CORR. PER NEC TABLE 310.15(B)(2)(a) X CONDUIT FILL CORR. PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.76 X 0.70 X 40 = 21.28A AC CONDUCTOR AMPACITY CALCULATIONS: FROM COMBINER BOX TO INTERCONNECTION: # OF INVERTERS: 45 EXPECTED WIRE TEMP (°C): 32° TEMP CORRECTION PER TABLE 310.15(B)(2)(a): 0.94 # OF CURRENT CARRYING CONDUCTORS: 3 CONDUIT FILL PER NEC 310.15(B)(3)(a): 1.0 CIRCUIT CONDUCTOR SIZE: 4AWG CIRCUIT CONDUCTOR AMPACITY: 85A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 1.25 X # MICRO-INVERTERS X MAX OUTPUT CURRENT = 1.25 X 1.21 X 45 = 68.06A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.16: TEMP CORR. PER NEC TABLE 310.15(B)(2)(a) X CONDUIT FILL CORR. PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.94 X 1.0 X 85= 79.9A RESULT SHOULD BE GREATER THAN 68.06A OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY RESULT SHOULD BE GREATER THAN 18.15A OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY ELECTRICAL CALCULATION SCALE: NTS1 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-7 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com WARNING LABELS WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: AC DISCONNECT & INVERTER (PER CODE: NEC690.54) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 54.45 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: EMT / CONDUIT RACEWAYS (PER CODE: NEC 690.31(E)(3) LABEL LOCATION: AC & DC DISCONNECT AND SUB PANEL (PER CODE: NEC 690.5(C)) LABEL LOCATION: MAIN SERVICE PANEL & NET METER (PER CODE: NEC 705.12(D)(4) & NEC 690.64) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER PER CODE: NEC 690.13 WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: AC DISCONNECT/BREAKER/ POINT OF CONNECTION (PER CODE: NEC 690.15 & NEC 690.14(C)2 PHOTOVOLTAIC AC DISCONNECT WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC & DC DISCONNECT AND SUB PANEL (PER CODE: NEC 690.17) ! 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-8 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com ADDITIONAL NOTES 1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT. 3. DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION DC CIRCUIT" OR EQUIV. EVERY 5 FT. 4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED. 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. 7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT SUFFICE. 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-9 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-10 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-11 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-12 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-13 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-14 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-15 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-16 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-17 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-18 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-19 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-20 PROJECT NAME UR11-20-2021INITIAL RELEASE ROB FISHER4811 PENDULA DR,CARMEL, IN 46033APN# 291404106006000018UTILITY: AES INDIANAAHJ: CITY OF CARMELSHEET SIZE ANSI B 11" X 17" 306 TEAL RD., W LAFAYETTE, IN 47909 PHONE# - (765)-474-6115 MOB# - (765)-4325338 Email - chrisb@hustonsolar.com SPEC SHEETS 12/20/21