HomeMy WebLinkAbout811039_568995_StructuralAnalysis_PASS_AT&T_11.17.2021.pdftnxTower Report - version 8.1.1.0 Date: November 17, 2021 Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Atlanta, GA 30346 (770) 379-8500 Subject: Structural Analysis Report Carrier Designation: AT&T Mobility Co-Locate Site Number: IN0099 Site Name: College Meadows Ind085 FA Number: 10023959 Crown Castle Designation: BU Number: 811039 Site Name: College Meadows Ind085 JDE Job Number: 667724 Work Order Number: 2038224 Order Number: 568995 Rev. 0 Engineering Firm Designation: Morrison Hershfield Project Number: CN9-073R1 / 2200039 Site Data: 750 E. 106th Street, Carmel, Hamilton County, IN 46280 Latitude 39° 56' 31.48'', Longitude -86° 8' 41.03'' 140 Foot - PiRod Monopole Tower Morrison Hershfield is pleased to submit this “Structural Analysis Report” to determine the structural integrity of the above-mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC7: Proposed Equipment Configuration Sufficient Capacity This analysis utilizes an ultimate 3-second gust wind speed of 115 mph as required by the Indiana Building Code (2012 IBC with Amendments). Applicable Standard references and design criteria are listed in Section 2 - Analysis Criteria. Respectfully submitted by: G. Lance Cooke, P.E (IN License No. 11300501) Senior Engineer tnxTower Report - version 8.1.1.0 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Equipment Configuration Table 2 - Other Considered Equipment 3) ANALYSIS PROCEDURE Table 3 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Table 5 - Tower Component Stresses vs. Capacity - LC7 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 3 tnxTower Report - version 8.1.1.0 1) INTRODUCTION This tower is a 140 ft Monopole tower designed by Pirod Manufactures Inc. The tower has been modified per reinforcement drawings prepared by Black & Veatch Corp. in May of 2017. Reinforcement consists of addition of a 10-ft tower extension, bringing the total tower height to 140 ft. 2) ANALYSIS CRITERIA TIA-222 Revision: TIA-222-H Risk Category: II Wind Speed: 115 mph Exposure Category: B Topographic Factor: 1 Ice Thickness: 2 in Wind Speed with Ice: 40 mph Service Wind Speed: 60 mph Table 1 - Proposed Equipment Configuration Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 101.0 104.0 3 ace XXQLH-654L8H8-IVT-V2 w/ Mount Pipe 12 4 2 1 7/8 3/8 3/4 2C 3 powerwave technologies 7750.00 w/ Mount Pipe 3 ericsson RRUS 4449 B5/B12 3 ericsson RRUS 4478 B14 1 raycap DC6-48-60-18-8F 2 raycap DC9-48-60-24-8C-EV 103.0 3 ericsson AIR 6449 N77 w/ Mount Pipe 3 ericsson RRUS 32 B2 3 ericsson RRUS 32 B30 3 ericsson RRUS 32 B66 6 powerwave November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 4 tnxTower Report - version 8.1.1.0 Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 135.0 135.0 3 ericsson RADIO 4449 3 ericsson RADIO 8843 - - 1 - Sector Mount [SM 502-3] w/ Walk Way 123.0 124.0 3 commscope FFVV-65C-R3-V1_TMO w/ Mount Pipe 6 2 1-1/4 1-1/2 3 nokia AEHC w/ Mount Pipe 3 nokia AHLOA_T-MOBILE 3 nokia AHFIG_TMO 2 commscope HCS 2.0 123.0 3 - 8' Pipe Mount [#2.0 STD] 1 Site Pro 1 Handrail Reinforcement Kit[#PRK-SFS-L] 1 Site Pro 1 Support Rail Kit [HRK 14] 1 - Platform Mount [LP 404-1] 114.0 114.0 3 jma wireless MX08FRO665-21 w/ Mount Pipe 1 1-3/4 3 fujitsu TA08025-B604 3 fujitsu TA08025-B605 1 raycap RDIDC-9181-PF-48 1 tower mounts Commscope MC-PK8-DSH 80.0 80.0 1 samsung telecommunications RRH-C2A W/EXT FILTER 3 1 1-1/2 1-1/8 3 samsung November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 5 tnxTower Report - version 8.1.1.0 3.1) Analysis Method tnxTower (version 8.1.1.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. When applicable, Crown Castle has calculated and provided the effective area for panel antennas using approved methods following the intent of the TIA-222 standard. 3.2) Assumptions 1) Tower and structures were maintained in accordance with the TIA-222 Standard. 2) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. Morrison Hershfield should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Section No. Elevation (ft) Component Type Size Critical Element P (K) SF*P_allow (K) % Capacity Pass / Fail L1 140 - 130 Pole P18x3/8 1 -5.75 902.61 6.8 Pass L2 130 - 100 Pole P24x3/8 2 -22.06 1104.67 51.9 Pass L3 100 - 80 Pole P30x3/8 3 -25.67 1376.61 68.9 Pass L4 80 - 60 Pole P36x3/8 4 -34.05 1564.60 78.5 Pass L5 60 - 40 Pole P42x3/8 5 -38.95 1752.31 81.5 Pass L6 40 - 20 Pole P48x3/8 6 -44.43 1939.86 81.7 Pass L7 20 - 0 Pole P54x3/8 7 -50.48 2127.30 80.5 Pass Summary Pole (L6) 81.7 Pass Rating = 81.7 Pass November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 6 tnxTower Report - version 8.1.1.0 Table 5 - Tower Component Stresses vs. Capacity - LC7 Notes Component Elevation (ft) % Capacity Pass / Fail 1,3 Flange Connection 130 7.5 Pass 1,2 Flange Connection 100 51.9 Pass 1,2 Flange Connection 80 68.9 Pass 1,3 Flange Connection 60 80.0 Pass 1,3 Flange Connection 40 84.7 Pass 1,3 Flange Connection 20 85.9 Pass 1 Anchor Rods 0 68.3 Pass 1,4 Base Plate 80.5 Pass 1 Base Foundation (Structure) 0 46.0 Pass 1 Base Foundation (Soil Interaction) 42.0 Pass Structure Rating (max from all components) = 85.9%* Notes: 1) See additional documentation in “Appendix C – Additional Calculations” for calculations supporting the % capacity consumed. 2) Flange plates are assumed to have the same capacity as their respective shaft. 3) Flange plates are assumed to have the same capacity as their respective splice bolts 4) Base plates are assumed to have the same capacity as their respective shaft. 5) *Rating as per TIA-222-H, Section 15.5. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the proposed load configuration. No modifications are required at this time. tnxTower Report - version 8.1.1.0 APPENDIX A TNXTOWER OUTPUT Consulting Engineers Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Atlanta, GA 30346 Phone: (770) 379-8500 FAX: (770) 379-8501 Job: CN9-073R1 / 2200039 Project: 811039 / College Meadows Ind085 Client: Crown Castle USA Drawn by: NT App'd: Code: TIA-222-H Date: 11/17/21 Scale: NTS Path: C:\Users\MTalluriNaga\OneDrive - MORRISON HERSHFIELD\Desktop\Jobs\Nov 17\CN9-073 - 811039 - COLLEGE MEADOWS IND085\CN9-073R1 SA\Analysis\CN9-073R1 BU_811039 WO_2038224.eri Dwg No. E-1 140.0 ft 130.0 ft 100.0 ft 80.0 ft 60.0 ft 40.0 ft 20.0 ft 0.0 ft REACTIONS - 115 mph WIND TORQUE 0 kip-ft 23 K SHEAR 2381 kip-ft MOMENT 50 K AXIAL 40 mph WIND - 2.0000 in ICE TORQUE 0 kip-ft 6 K SHEAR 618 kip-ft MOMENT 101 K AXIAL ARE FACTORED ALL REACTIONS Section 7 6 5 4 3 2 1 Size P54x3/8 P48x3/8 P42x3/8 P36x3/8 P30x3/8 P24x3/8 P18x3/8 Length (ft) 20.00 20.00 20.00 20.00 20.00 30.00 10.00 Grade A53-B-42 A500-46 Weight (K) 20.2 4.3 3.8 3.3 2.9 2.4 2.8 0.7 MATERIAL STRENGTH GRADE Fy Fu GRADE Fy Fu A500-46 46 ksi 62 ksi A53-B-42 42 ksi 63 ksi TOWER DESIGN NOTES 1. Tower is located in Hamilton County, Indiana. 2. Tower designed for Exposure B to the TIA-222-H Standard. November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 8 tnxTower Report - version 8.1.1.0 Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-H standard. The following design criteria apply: Tower is located in Hamilton County, Indiana. Tower base elevation above sea level: 846.00 ft. Basic wind speed of 115 mph. Risk Category II. Exposure Category B. Simplified Topographic Factor Procedure for wind speed-up calculations is used. Topographic Category: 1. Crest Height: 0.00 ft. Nominal ice thickness of 2.0000 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 40 mph is used in combination with ice. Temperature drop of 50 °F. Deflections calculated using a wind speed of 60 mph. A non-linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Tower analysis based on target reliabilities in accordance with Annex S. Load Modification Factors used: Kes(Fw) = 0.95, Kes(ti) = 0.85. Maximum demand-capacity ratio is: 1.05. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments - Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments - Diagonals √ Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression √ Use Code Stress Ratios Use Clear Spans For KL/r All Leg Panels Have Same Allowable √ Use Code Safety Factors - Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice √ Bypass Mast Stability Checks √ Consider Feed Line Torque Always Use Max Kz √ Use Azimuth Dish Coefficients Include Angle Block Shear Check Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-H Bracing Resist. Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles Secondary Horizontal Braces Leg Sort Capacity Reports By Component √ Include Shear-Torsion Interaction Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Corner Radii Are Known Pole Section Geometry Section Elevation ft Section Length ft Pole Size November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 9 tnxTower Report - version 8.1.1.0 Section Elevation ft Section Length ft Pole Size Pole Grade Socket Length ft (42 ksi) L3 100.00-80.00 20.00 P30x3/8 A53-B-42 (42 ksi) L4 80.00-60.00 20.00 P36x3/8 A53-B-42 (42 ksi) L5 60.00-40.00 20.00 P42x3/8 A53-B-42 (42 ksi) L6 40.00-20.00 20.00 P48x3/8 A53-B-42 (42 ksi) L7 20.00-0.00 20.00 P54x3/8 A53-B-42 (42 ksi) Tower Elevation ft Gusset Area (per face) ft2 Gusset Thickness in Gusset Grade Adjust. Factor Af Adjust. Factor Ar Weight Mult. Double Angle Stitch Bolt Spacing Diagonals in Double Angle Stitch Bolt Spacing Horizontals in Double Angle Stitch Bolt Spacing Redundants in L1 140.00- 130.00 1 1 1 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 10 tnxTower Report - version 8.1.1.0 Feed Line/Linear Appurtenances - Entered As Area Description Face or Leg Allow Shield Exclude From Torque Calculation Componen t Type Placement ft Total Number CAAA ft2/ft Weight plf ****** HCH-6624XXX(1- 3/8) C No No Inside Pole 135.00 - 0.00 2 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 0.00 0.00 0.00 1.89 1.89 1.89 1.89 ****** AVA6-50(1-1/4) B No No Inside Pole 123.00 - 0.00 6 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 0.00 0.00 0.00 0.46 0.46 0.46 0.46 ****** ****** LDF2-50A(3/8) A No No Inside Pole 101.00 - 0.00 1 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 11 tnxTower Report - version 8.1.1.0 Tower Sectio n Tower Elevation ft Face AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K B C 0.000 0.000 0.000 0.000 12.450 11.260 0.000 0.000 0.18 0.15 L5 60.00-40.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.450 11.260 0.000 0.000 0.000 0.23 0.18 0.15 L6 40.00-20.00 A B C 0.000 0.000 0.000 0.000 0.000 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 12 tnxTower Report - version 8.1.1.0 Tower Section Feed Line Record No. Description Feed Line Segment Elev. Ka No Ice Ka Ice 140.00 L2 1 Safety Line 3/8 100.00 - 130.00 1.0000 1.0000 L2 2 Climbing Rung 100.00 - 130.00 1.0000 1.0000 L2 9 HCS 2.0 Part 3(1-1/2) 100.00 - 123.00 1.0000 1.0000 L2 11 CU12PSM6P4XXX(1-3/4) 100.00 - 114.00 1.0000 1.0000 L3 1 Safety Line 3/8 80.00 - 100.00 1.0000 1.0000 L3 2 Climbing Rung 80.00 - 100.00 1.0000 1.0000 L3 9 HCS 2.0 Part 3(1-1/2) 80.00 - 100.00 1.0000 1.0000 L3 11 CU12PSM6P4XXX(1-3/4) 80.00 - 100.00 1.0000 1.0000 L4 1 Safety Line 3/8 60.00 - 80.00 1.0000 1.0000 L4 2 Climbing Rung 60.00 - 80.00 1.0000 1.0000 L4 9 HCS 2.0 Part 3(1-1/2) 60.00 - 80.00 1.0000 1.0000 L4 11 CU12PSM6P4XXX(1-3/4) 60.00 - 80.00 1.0000 1.0000 L4 29 SPRINT NMP_HYBRID CABLE(1-1/2) 60.00 - 80.00 1.0000 1.0000 L4 31 942-98886-1FXXX(1-1/8) 60.00 - 80.00 1.0000 1.0000 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 13 tnxTower Report - version 8.1.1.0 Discrete Tower Loads Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K ****** (2) JAHH-65C-R3B w/ Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 6.60 7.14 7.69 8.83 5.11 5.63 6.17 7.27 0.12 0.21 0.32 0.57 (2) JAHH-65C-R3B w/ Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 14 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 0.00 0.00 1/2'' Ice 1'' Ice 2'' Ice 3.74 3.99 4.51 2.57 2.78 3.24 0.11 0.15 0.22 RADIO 8843 B From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.50 3.74 3.99 4.51 2.36 2.57 2.78 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 15 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 3] 1/2'' Ice 1'' Ice 2'' Ice 4.18 4.75 5.90 4.18 4.75 5.90 0.11 0.14 0.20 Side Arm Mount [SO 102- 3] C None 0.0000 132.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.60 4.18 4.75 5.90 3.60 4.18 4.75 5.90 0.07 0.11 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 16 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 2'' Ice AEHC w/ Mount Pipe B From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 6.91 7.40 7.91 8.99 2.77 3.15 3.55 4.39 0.11 0.16 0.22 0.36 AEHC w/ Mount Pipe C From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 6.91 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 17 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 1'' Ice 2'' Ice 10.11 6.12 0.52 TA08025-B604 A From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.96 2.14 2.32 2.71 0.98 1.11 1.25 1.55 0.06 0.08 0.10 0.15 TA08025-B604 B From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 18 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 0.00 3.00 1/2'' Ice 1'' Ice 2'' Ice 6.18 6.61 7.49 5.01 5.71 7.16 0.10 0.16 0.29 7750.00 w/ Mount Pipe C From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 5.75 6.18 6.61 7.49 4.25 5.01 5.71 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 19 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 0.00 2.00 1/2'' Ice 1'' Ice 2'' Ice 1.24 1.38 1.69 0.44 0.54 0.77 0.02 0.03 0.05 Platform Mount [LP 303- 1_HR-1] C None 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 17.09 21.47 25.72 33.96 17.09 21.47 25.72 33.96 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 20 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K XXQLH-654L8H8-IVT-V2 w/ Mount Pipe C From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 11.80 12.52 13.25 14.75 5.99 6.65 7.32 8.70 0.15 0.26 0.38 0.67 RRUS 4449 B5/B12 A From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 21 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 2'' Ice RRH-P4 A From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.74 2.95 3.17 3.63 1.79 1.97 2.16 2.57 0.06 0.08 0.11 0.17 RRH-P4 B From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.74 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 22 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 2'' Ice 9' x 2'' Pipe Mount B From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.14 3.07 4.01 5.13 2.14 3.07 4.01 5.13 0.07 0.08 0.10 0.17 9' x 2'' Pipe Mount C From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.14 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 23 tnxTower Report - version 8.1.1.0 Comb. No. Description 25 0.9 Dead+1.0 Wind 330 deg - No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg - Service 40 Dead+Wind 30 deg - Service 41 Dead+Wind 60 deg - Service 42 Dead+Wind 90 deg - Service 43 Dead+Wind 120 deg - Service 44 Dead+Wind 150 deg - Service 45 Dead+Wind 180 deg - Service 46 Dead+Wind 210 deg - Service 47 Dead+Wind 240 deg - Service 48 Dead+Wind 270 deg - Service 49 Dead+Wind 300 deg - Service 50 Dead+Wind 330 deg - Service Maximum Member Forces Sectio n No. Elevation ft Component Type Condition Gov. Load Comb. Axial K Major Axis Moment kip-ft Minor Axis Moment kip-ft L1 140 - 130 Pole Max Tension 3 0.00 0.00 -0.00 Max. Compression 26 -16.28 -0.06 1.24 Max. Mx 8 -5.75 -24.98 0.21 Max. My 2 -5.75 -0.00 25.39 Max. Vy 8 5.03 -24.98 0.21 Max. Vx 2 -5.06 -0.00 25.39 Max. Torque 8 0.52 L2 130 - 100 Pole Max Tension 1 0.00 0.00 0.00 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 24 tnxTower Report - version 8.1.1.0 Sectio n No. Elevation ft Component Type Condition Gov. Load Comb. Axial K Major Axis Moment kip-ft Minor Axis Moment kip-ft L6 40 - 20 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 26 -92.67 -5.88 2.39 Max. Mx 8 -44.43 -1918.91 0.08 Max. My 2 -44.43 -0.77 1928.87 Max. Vy 8 22.10 -1918.91 0.08 Max. Vx 2 -22.21 -0.77 1928.87 Max. Torque 10 0.23 L7 20 - 0 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 26 -101.28 -7.05 2.19 Max. Mx 8 -50.48 -2369.43 -0.01 Max. My 2 -50.48 -1.01 2381.19 Max. Vy 8 22.91 -2369.43 -0.01 Max. Vx 2 -23.02 -1.01 2381.19 Max. Torque 10 0.23 Maximum Reactions Location Condition Gov. Load Comb. Vertical K Horizontal, X K Horizontal, Z K Pole Max. Vert 26 101.28 -0.00 0.00 Max. Hx 21 37.86 22.90 0.00 Max. Hz 3 37.86 0.00 23.01 Max. Mx 2 2381.19 0.00 23.01 Max. Mz 8 2369.43 -22.90 -0.00 Max. Torsion 10 0.23 -19.83 -11.51 Min. Vert 19 37.86 19.83 -11.50 Min. Hx 9 37.86 -22.90 -0.00 Min. Hz 15 37.86 -0.00 -23.01 Min. Mx 14 -2380.35 -0.00 -23.01 Min. Mz 20 -2366.54 22.90 0.00 Min. Torsion 22 -0.23 19.83 11.51 Tower Mast Reaction Summary Load November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 25 tnxTower Report - version 8.1.1.0 Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft 0.9 Dead+1.0 Wind 150 deg - No Ice 37.86 11.45 19.93 2035.48 -1170.36 -0.18 1.2 Dead+1.0 Wind 180 deg - No Ice 50.48 0.00 23.01 2380.35 -1.88 -0.09 0.9 Dead+1.0 Wind 180 deg - No Ice 37.86 0.00 23.01 2350.15 -1.50 -0.09 1.2 Dead+1.0 Wind 210 deg - No Ice 50.48 -11.45 19.92 2061.18 1182.17 0.04 0.9 Dead+1.0 Wind 210 deg - No Ice 37.86 -11.45 19.92 2035.05 1167.48 0.03 1.2 Dead+1.0 Wind 240 deg - No Ice 50.48 -19.83 11.50 1189.60 2049.07 0.15 0.9 Dead+1.0 Wind 240 deg - No Ice 37.86 -19.83 11.50 1174.57 2023.36 0.15 1.2 Dead+1.0 Wind 270 deg - No Ice 50.48 -22.90 -0.00 -0.85 2366.54 0.22 0.9 Dead+1.0 Wind 270 deg - No Ice 37.86 -22.90 -0.00 -0.73 2336.78 0.22 1.2 Dead+1.0 Wind 300 deg - No Ice 50.48 -19.83 -11.51 -1191.18 2049.51 0.23 0.9 Dead+1.0 Wind 300 deg - No Ice 37.86 -19.83 -11.51 -1175.91 2023.78 0.23 1.2 Dead+1.0 Wind 330 deg - No Ice 50.48 -11.45 -19.93 -2062.45 1182.92 0.18 0.9 Dead+1.0 Wind 330 deg - No Ice 37.86 -11.45 -19.93 -2036.09 1168.22 0.18 1.2 Dead+1.0 Ice+1.0 Temp 101.28 0.00 -0.00 -2.19 -7.05 -0.00 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 26 tnxTower Report - version 8.1.1.0 Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft Dead+Wind 330 deg - Service 42.07 -2.94 -5.11 -524.94 300.11 0.05 Solution Summary Load Comb. Sum of Applied Forces Sum of Reactions PX % Error K PY K PZ K PX K PY K PZ K 1 0.00 -42.07 0.00 0.00 42.07 0.00 0.000% 2 -0.00 -50.48 -23.01 0.00 50.48 23.01 0.000% 3 -0.00 -37.86 -23.01 0.00 37.86 23.01 0.000% 4 11.45 -50.48 -19.92 -11.45 50.48 19.92 0.000% 5 11.45 -37.86 -19.92 -11.45 37.86 19.92 0.000% 6 19.83 -50.48 -11.50 -19.83 50.48 11.50 0.000% 7 19.83 -37.86 -11.50 -19.83 37.86 11.50 0.000% 8 22.90 -50.48 0.00 -22.90 50.48 -0.00 0.000% 9 22.90 -37.86 0.00 -22.90 37.86 -0.00 0.000% 10 19.83 -50.48 11.51 -19.83 50.48 -11.51 0.000% 11 19.83 -37.86 11.51 -19.83 37.86 -11.51 0.000% 12 11.45 -50.48 19.93 -11.45 50.48 -19.93 0.000% 13 11.45 -37.86 19.93 -11.45 37.86 -19.93 0.000% 14 0.00 -50.48 23.01 -0.00 50.48 -23.01 0.000% 15 0.00 -37.86 23.01 -0.00 37.86 -23.01 0.000% 16 -11.45 -50.48 19.92 11.45 50.48 -19.92 0.000% 17 -11.45 -37.86 19.92 11.45 37.86 -19.92 0.000% 18 -19.83 -50.48 11.50 19.83 50.48 -11.50 0.000% 19 -19.83 -37.86 11.50 19.83 37.86 -11.50 0.000% 20 -22.90 -50.48 -0.00 22.90 50.48 0.00 0.000% 21 -22.90 -37.86 -0.00 22.90 37.86 0.00 0.000% November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 27 tnxTower Report - version 8.1.1.0 Non-Linear Convergence Results Load Combination Converged? Number of Cycles Displacement Tolerance Force Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 5 0.00000001 0.00006870 3 Yes 4 0.00000001 0.00057487 4 Yes 6 0.00000001 0.00013937 5 Yes 6 0.00000001 0.00005051 6 Yes 6 0.00000001 0.00014019 7 Yes 6 0.00000001 0.00005085 8 Yes 5 0.00000001 0.00007892 9 Yes 4 0.00000001 0.00070418 10 Yes 6 0.00000001 0.00013809 11 Yes 6 0.00000001 0.00005007 12 Yes 6 0.00000001 0.00014046 13 Yes 6 0.00000001 0.00005095 14 Yes 5 0.00000001 0.00006910 15 Yes 4 0.00000001 0.00058001 16 Yes 6 0.00000001 0.00013931 17 Yes 6 0.00000001 0.00005056 18 Yes 6 0.00000001 0.00013799 19 Yes 6 0.00000001 0.00005007 20 Yes 5 0.00000001 0.00007989 21 Yes 4 0.00000001 0.00071599 22 Yes 6 0.00000001 0.00014042 23 Yes 6 0.00000001 0.00005097 24 Yes 6 0.00000001 0.00013856 25 Yes 6 0.00000001 0.00005023 26 Yes 4 0.00000001 0.00017634 27 Yes 6 0.00000001 0.00027115 28 Yes 6 0.00000001 0.00030064 29 Yes 6 0.00000001 0.00030052 30 Yes 6 0.00000001 0.00027094 31 Yes 6 0.00000001 0.00029583 32 Yes 6 0.00000001 0.00029539 33 Yes 6 0.00000001 0.00026568 34 Yes 6 0.00000001 0.00028956 35 Yes 6 0.00000001 0.00028891 36 Yes 6 0.00000001 0.00026420 37 Yes 6 0.00000001 0.00029373 38 Yes 6 0.00000001 0.00029497 39 Yes 4 0.00000001 0.00022031 40 Yes 4 0.00000001 0.00069231 41 Yes 4 0.00000001 0.00070465 42 Yes 4 0.00000001 0.00022293 43 Yes 4 0.00000001 0.00067766 44 Yes 4 0.00000001 0.00070382 45 Yes 4 0.00000001 0.00021966 46 Yes 4 0.00000001 0.00069024 47 Yes 4 0.00000001 0.00067630 November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 28 tnxTower Report - version 8.1.1.0 Critical Deflections and Radius of Curvature - Service Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 138.00 Side Arm Mount [SO 102-3] 39 16.047 1.0129 0.0014 113112 135.00 (2) JAHH-65C-R3B w/ Mount Pipe 39 15.410 1.0120 0.0013 113112 133.00 Walkway (3) 39 14.986 1.0107 0.0012 79727 132.00 Side Arm Mount [SO 102-3] 39 14.775 1.0097 0.0012 68007 123.00 8' Pipe Mount [#2.0 STD] 39 12.882 0.9876 0.0009 19304 114.00 MX08FRO665-21 w/ Mount Pipe 39 11.039 0.9431 0.0006 10452 101.00 7750.00 w/ Mount Pipe 39 8.553 0.8487 0.0003 6368 80.00 P65-16-XLPP-RR w/ Mount Pipe 39 5.199 0.6542 0.0002 6000 Maximum Tower Deflections - Design Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 140 - 130 64.829 2 3.9891 0.0055 L2 130 - 100 56.491 2 3.9654 0.0044 L3 100 - 80 32.959 2 3.3101 0.0010 L4 80 - 60 20.460 2 2.5764 0.0006 L5 60 - 40 11.100 2 1.8365 0.0003 L6 40 - 20 4.765 2 1.1510 0.0002 L7 20 - 0 1.170 2 0.5396 0.0001 Critical Deflections and Radius of Curvature - Design Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 29 tnxTower Report - version 8.1.1.0 Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K φPn K Ratio Pu φPn 3 L6 40 - 20 (6) P48x3/8 20.00 0.00 0.0 56.106 9 -44.43 1847.49 0.024 L7 20 - 0 (7) P54x3/8 20.00 0.00 0.0 63.175 5 -50.48 2026.00 0.025 Pole Bending Design Data Section No. Elevation ft Size Mux kip-ft φMnx kip-ft Ratio Mux φMnx Muy kip-ft φMny kip-ft Ratio Muy φMny L1 140 - 130 (1) P18x3/8 25.39 393.27 0.065 0.00 393.27 0.000 L2 130 - 100 (2) P24x3/8 325.16 623.72 0.521 0.00 623.72 0.000 L3 100 - 80 (3) P30x3/8 665.17 947.86 0.702 0.00 947.86 0.000 L4 80 - 60 (4) P36x3/8 1070.16 1338.81 0.799 0.00 1338.81 0.000 L5 60 - 40 (5) P42x3/8 1491.93 1796.56 0.830 0.00 1796.56 0.000 L6 40 - 20 (6) P48x3/8 1928.87 2321.11 0.831 0.00 2321.11 0.000 L7 20 - 0 (7) P54x3/8 2381.18 2912.46 0.818 0.00 2912.46 0.000 Pole Shear Design Data Section No. November 17, 2021 140 Ft Monopole Tower Structural Analysis CCI BU No 811039 Project Number CN9-073R1 / 2200039, Order 568995, Revision 0 Page 30 tnxTower Report - version 8.1.1.0 Section Capacity Table Section No. Elevation ft Component Type Size Critical Element P K øPallow K % Capacity Pass Fail L1 140 - 130 Pole P18x3/8 1 -5.75 902.61 6.8 Pass L2 130 - 100 Pole P24x3/8 2 -22.06 1104.67 51.9 Pass L3 100 - 80 Pole P30x3/8 3 -25.67 1376.61 68.9 Pass L4 80 - 60 Pole P36x3/8 4 -34.05 1564.60 78.5 Pass L5 60 - 40 Pole P42x3/8 5 -38.95 1752.31 81.5 Pass L6 40 - 20 Pole P48x3/8 6 -44.43 1939.86 81.7 Pass L7 20 - 0 Pole P54x3/8 7 -50.48 2127.30 80.5 Pass Summary Pole (L6) 81.7 Pass RATING = 81.7 Pass tnxTower Report - version 8.1.1.0 APPENDIX B BASE LEVEL DRAWING tnxTower Report - version 8.1.1.0 APPENDIX C ADDITIONAL CALCULATIONS Monopole Flange Plate Connection *TIA-222-H Section 15.5 Applied Top Plate Data Bottom Plate Data 24.375" OD x 1.25" Plate (A572-50; Fy=50 ksi, Fu=65 ksi) 18" ID x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) Top Stiffener Data Bottom Stiffener Data N/A N/A Top Pole Data Bottom Pole Data 18" x 0.375" round pole (A500-46; Fy=46 ksi, Fu=62 ksi) 24" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) Max Load (kips) 3.27 Allowable (kips) 41.58 Stress Rating: 7.5% Pass Top Plate Capacity Bottom Plate Capacity - - - - Pirod OK Pirod OK Pirod OK Pirod OK Allowable Stress (ksi): Allowable Stress (ksi): Stress Rating: Stress Rating: Tension Side Stress Rating: Tension Side Stress Rating: Analysis Results Bolt Capacity Max Stress (ksi): Max Stress (ksi): TIA-222 Revision H Top Plate - External Bottom Plate - Internal Connection Properties Bolt Data (16) 7/8" ø bolts (A325 N; Fy=92 ksi, Fu=120 ksi) on 21" BC Order # 568995 Rev.0 Axial Force (kips) 5.75 Axial Force (kips) 0.00 Shear Force (kips) 5.06 Shear Force (kips) 0.00 Elevation = 130 ft. BU # 811039 Applied Loads Applied Loads to Bridge Stiffeners Site Name College Meadows Ind085 Moment (kip-ft) 25.39 Moment (kip-ft) 0.00 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 CCIplate - Version 4.1.2 Analysis Date: 11/17/2021 Monopole Flange Plate Connection *TIA-222-H Section 15.5 Applied Top Plate Data Bottom Plate Data 30" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) 24" ID x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) Top Stiffener Data Bottom Stiffener Data N/A N/A Top Pole Data Bottom Pole Data 24" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) 30" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) Max Load (kips) 27.78 Allowable (kips) 54.52 Stress Rating: 48.5% Pass Top Plate Capacity Bottom Plate Capacity - - - - Pirod OK Pirod OK Pirod OK Pirod OK Allowable Stress (ksi): Allowable Stress (ksi): Stress Rating: Stress Rating: Tension Side Stress Rating: Tension Side Stress Rating: Analysis Results Bolt Capacity Max Stress (ksi): Max Stress (ksi): TIA-222 Revision H Top Plate - External Bottom Plate - Internal Connection Properties Bolt Data (20) 1" ø bolts (A325 N; Fy=92 ksi, Fu=120 ksi) on 27" BC Order # 568995 Rev.0 Axial Force (kips) 22.06 Axial Force (kips) 0.00 Shear Force (kips) 16.58 Shear Force (kips) 0.00 Elevation = 100 ft. BU # 811039 Applied Loads Applied Loads to Bridge Stiffeners Site Name College Meadows Ind085 Moment (kip-ft) 325.16 Moment (kip-ft) 0.00 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 CCIplate - Version 4.1.2 Analysis Date: 11/17/2021 Monopole Flange Plate Connection *TIA-222-H Section 15.5 Applied Top Plate Data Bottom Plate Data 36" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) 30" ID x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) Top Stiffener Data Bottom Stiffener Data N/A N/A Top Pole Data Bottom Pole Data 30" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) 36" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) Max Load (kips) 39.23 Allowable (kips) 54.53 Stress Rating: 68.5% Pass Top Plate Capacity Bottom Plate Capacity - - - - Pirod OK Pirod OK Pirod OK Pirod OK Allowable Stress (ksi): Allowable Stress (ksi): Stress Rating: Stress Rating: Tension Side Stress Rating: Tension Side Stress Rating: Analysis Results Bolt Capacity Max Stress (ksi): Max Stress (ksi): TIA-222 Revision H Top Plate - External Bottom Plate - Internal Connection Properties Bolt Data (24) 1" ø bolts (A325 N; Fy=92 ksi, Fu=120 ksi) on 33" BC Order # 568995 Rev.0 Axial Force (kips) 25.67 Axial Force (kips) 0.00 Shear Force (kips) 17.39 Shear Force (kips) 0.00 Elevation = 80 ft. BU # 811039 Applied Loads Applied Loads to Bridge Stiffeners Site Name College Meadows Ind085 Moment (kip-ft) 665.17 Moment (kip-ft) 0.00 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 CCIplate - Version 4.1.2 Analysis Date: 11/17/2021 Monopole Flange Plate Connection *TIA-222-H Section 15.5 Applied Top Plate Data Bottom Plate Data 42" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) 36" ID x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) Top Stiffener Data Bottom Stiffener Data N/A N/A Top Pole Data Bottom Pole Data 36" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) 42" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) Max Load (kips) 45.81 Allowable (kips) 54.53 Stress Rating: 80.0% Pass Top Plate Capacity Bottom Plate Capacity - - - - Pirod OK Pirod OK Pirod OK Pirod OK Allowable Stress (ksi): Allowable Stress (ksi): Stress Rating: Stress Rating: Tension Side Stress Rating: Tension Side Stress Rating: Analysis Results Bolt Capacity Max Stress (ksi): Max Stress (ksi): TIA-222 Revision H Top Plate - External Bottom Plate - Internal Connection Properties Bolt Data (28) 1" ø bolts (A325 N; Fy=92 ksi, Fu=120 ksi) on 39" BC Order # 568995 Rev.0 Axial Force (kips) 34.05 Axial Force (kips) 0.00 Shear Force (kips) 20.68 Shear Force (kips) 0.00 Elevation = 60 ft. BU # 811039 Applied Loads Applied Loads to Bridge Stiffeners Site Name College Meadows Ind085 Moment (kip-ft) 1070.16 Moment (kip-ft) 0.00 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 CCIplate - Version 4.1.2 Analysis Date: 11/17/2021 Monopole Flange Plate Connection *TIA-222-H Section 15.5 Applied Top Plate Data Bottom Plate Data 48" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) 42" ID x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) Top Stiffener Data Bottom Stiffener Data N/A N/A Top Pole Data Bottom Pole Data 42" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) 48" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) Max Load (kips) 48.50 Allowable (kips) 54.53 Stress Rating: 84.7% Pass Top Plate Capacity Bottom Plate Capacity - - - - Pirod OK Pirod OK Pirod OK Pirod OK Allowable Stress (ksi): Allowable Stress (ksi): Stress Rating: Stress Rating: Tension Side Stress Rating: Tension Side Stress Rating: Analysis Results Bolt Capacity Max Stress (ksi): Max Stress (ksi): TIA-222 Revision H Top Plate - External Bottom Plate - Internal Connection Properties Bolt Data (32) 1" ø bolts (A325 N; Fy=92 ksi, Fu=120 ksi) on 45" BC Order # 568995 Rev.0 Axial Force (kips) 38.95 Axial Force (kips) 0.00 Shear Force (kips) 21.48 Shear Force (kips) 0.00 Elevation = 40 ft. BU # 811039 Applied Loads Applied Loads to Bridge Stiffeners Site Name College Meadows Ind085 Moment (kip-ft) 1491.92 Moment (kip-ft) 0.00 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 CCIplate - Version 4.1.2 Analysis Date: 11/17/2021 Monopole Flange Plate Connection *TIA-222-H Section 15.5 Applied Top Plate Data Bottom Plate Data 54" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) 48" ID x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) Top Stiffener Data Bottom Stiffener Data N/A N/A Top Pole Data Bottom Pole Data 48" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) 54" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) Max Load (kips) 49.19 Allowable (kips) 54.53 Stress Rating: 85.9% Pass Top Plate Capacity Bottom Plate Capacity - - - - Pirod OK Pirod OK Pirod OK Pirod OK Allowable Stress (ksi): Allowable Stress (ksi): Stress Rating: Stress Rating: Tension Side Stress Rating: Tension Side Stress Rating: Analysis Results Bolt Capacity Max Stress (ksi): Max Stress (ksi): TIA-222 Revision H Top Plate - External Bottom Plate - Internal Connection Properties Bolt Data (36) 1" ø bolts (A325 N; Fy=92 ksi, Fu=120 ksi) on 51" BC Order # 568995 Rev.0 Axial Force (kips) 44.43 Axial Force (kips) 0.00 Shear Force (kips) 22.21 Shear Force (kips) 0.00 Elevation = 20 ft. BU # 811039 Applied Loads Applied Loads to Bridge Stiffeners Site Name College Meadows Ind085 Moment (kip-ft) 1928.87 Moment (kip-ft) 0.00 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 CCIplate - Version 4.1.2 Analysis Date: 11/17/2021 Monopole Base Plate Connection *TIA-222-H Section 15.5 Applied #VALUE! Anchor Rod Data Anchor Rod Summary (units of kips, kip-in) (48) 1" ø bolts (A687 N; Fy=105 ksi, Fu=125 ksi) on 57" BC Pu_t = 40.72 φPn_t = 56.81 Stress Rating Vu = 0.48 φVn = 36.82 68.3% Base Plate Data Mu = 0.86 φMn = 15.75 Pass 60.125" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) Base Plate Summary Stiffener Data Max Stress (ksi): - N/A Allowable Stress (ksi): - Stress Rating: Pirod OK Pole Data 54" x 0.375" round pole (A53-B-42; Fy=42 ksi, Fu=63 ksi) Connection Properties Analysis Results Iar (in) 2.75 Moment (kip-ft) 2381.19 Axial Force (kips) 50.48 Shear Force (kips) 23.02 Moment (kip-ft) Axial Force (kips) Shear Force (kips) 0.00 BU # 811039 Applied Loads Site Name College Meadows Ind085 Order # 568995 Rev.0 Analysis Considerations Site Info TIA-222 Revision H Grout Considered: No 50.48 23.02 Adjusted Pole Reactions CCIplate - Version 4.1.2 Analysis Date: 11/17/2021 Tower Type: 50.48 kips Capacity Demand Rating* Check 23.01 kips 720.11 0.00 0.0% Pass 336.07 23.01 6.5% Pass 5.36 2.05 36.4% Pass 2381.19 ft-kips 6131.23 2572.46 42.0% Pass 140 ft 6243.38 2507.75 38.3% Pass ft 558.49 0.00 0.0% Pass 3.75 in 17996.05 78.47 0.4% Pass in 2869.74 921.70 30.6% Pass 705.87 146.55 19.8% Pass 0.190 0.046 22.9% Pass Circular 3117.94 1504.65 46.0% Pass 6 ft 0.190 0.000 0.0% Pass 0.5 ft 3117.94 0.00 0.0% Pass 11 31 4 Structural Rating*: 46.0% 7 Soil Rating*: 42.0% Tie 3 in 7.5 ft 24.5 ft 2.5 ft 9 26 3 in 60 ksi 4 ksi 150 pcf 130 pcf 6.170 ksf <--Toggle between Gross and Net 0.600 ksf 15 degrees 7 0.4 3.00 ft No N/A ft Top & Bot. Pad Rein. Different?: *Rating per TIA-222-H Section 15.5 Foundation Bearing on Rock? SPT Blow Count, Nblows: Base Friction, μ: Pier Diameter, dpier: Ext. Above Grade, E: Pier Rebar Size, Sc: Pier Rebar Quantity, mc: Concrete Compressive Strength, F'c: Pier Tie/Spiral Quantity, mt: Pier Reinforcement Type: Pier Clear Cover, ccpier: Pad Properties Pier Tie/Spiral Size, St: Neglected Depth, N: Uplift Shear, Vu_uplift: Pier Shape: Tower Height, H: Base Face Width, BW: ASCE 7 Hazards Report Address: No Address at This Location Standard: ASCE/SEI 7-10 Risk Category: II Soil Class: D - Stiff Soil Elevation: 845.76 ft (NAVD 88) Latitude: Longitude: 39.942078 -86.144731 Wind Results: Wind Speed: 115 Vmph 10-year MRI 76 Vmph 25-year MRI 84 Vmph 50-year MRI 90 Vmph 100-year MRI 96 Vmph Data Source: ASCE/SEI 7-10, Fig. 26.5-1A and Figs. CC-1–CC-4, and Section 26.5.2, incorporating errata of March 12, 2014 Date Accessed: Wed Nov 17 2021 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-10 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-10 Section 26.2. https://asce7hazardtool.online/ Page 1 of 3 Wed Nov 17 2021 SS : 0.149 S1 : 0.082 Fa : 1.6 Fv : 2.4 SMS : 0.238 SM1 : 0.197 SDS : 0.159 SD1 : 0.132 TL : 12 PGA : 0.068 PGA M : 0.109 FPGA : 1.6 Ie : 1 Design Response Spectrum S a (g) vs T(s) MCE R Response Spectrum S a (g) vs T(s) Seismic Site Soil Class: Results: Seismic Design Category D - Stiff Soil B Data Accessed: Date Source: Wed Nov 17 2021 USGS Seismic Design Maps based on ASCE/SEI 7-10, incorporating Supplement 1 and errata of March 31, 2013, and ASCE/SEI 7-10 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-10 Ch. 21 are available from USGS. https://asce7hazardtool.online/ Page 2 of 3 Wed Nov 17 2021 Ice Results: Data Source: Date Accessed: Ice Thickness: 1.00 in. Concurrent Temperature: 5 F Gust Speed: 40 mph Standard ASCE/SEI 7-10, Figs. 10-2 through 10-8 Wed Nov 17 2021 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 50-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https://asce7hazardtool.online/ Page 3 of 3 Wed Nov 17 2021 Design Ice= 1x2=2" Cohesion, Cu: Ultimate Net Bearing, Qnet: Pad Rebar Quantity (Bottom dir. 2), mp2: Pad Rebar Size (Bottom dir. 2), Sp2: Total Soil Unit Weight, γ: Pier Flexure (Comp.) (kip*ft) Lateral (Sliding) (kips) Bearing Pressure (ksf) Uplift (kips) Foundation Analysis Checks Pier and Pad Foundation BU # : Site Name: Compression, Pcomp: TIA-222 Revision: App. Number: Superstructure Analysis Reactions H Monopole 811039 College Meadows Ind085 568995 Rev.0 Block Foundation?: Pad Shear - 2-way (Comp) (ksi) Pier Flexure (Tension) (kip*ft) Overturning (kip*ft) Pad Flexure (kip*ft) Pad Shear - 1-way (kips) Pier Compression (kip) Rectangular Pad?: Flexural 2-way (Tension) (kip*ft) Pad Shear - 2-way (Uplift) (ksi) Pier Properties BP Dist. Above Fdn, bpdist: Bolt Circle / Bearing Plate Width, BC: Flexural 2-way (Comp) (kip*ft) Uplift, Puplift: Base Shear, Vu_comp: Groundwater Depth, gw: Rebar Grade, Fy: Dry Concrete Density, δc: Depth, D: Pad Width, W1: Pad Thickness, T: Pad Clear Cover, ccpad: Material Properties Soil Properties Friction Angle, ϕ: Moment, Mu: Version 4.1.1 Elevation ft Size Actual Vu K φVn K Ratio Vu φVn Actual Tu kip-ft φTn kip-ft Ratio Tu φTn L1 140 - 130 (1) P18x3/8 5.06 257.89 0.020 0.00 399.61 0.000 L2 130 - 100 (2) P24x3/8 16.58 315.62 0.053 0.08 655.57 0.000 L3 100 - 80 (3) P30x3/8 17.39 395.78 0.044 0.08 994.73 0.000 L4 80 - 60 (4) P36x3/8 20.68 454.19 0.046 0.08 1094.28 0.000 L5 60 - 40 (5) P42x3/8 21.48 444.34 0.048 0.08 1250.07 0.000 L6 40 - 20 (6) P48x3/8 22.21 459.94 0.048 0.08 1480.47 0.000 L7 20 - 0 (7) P54x3/8 23.02 474.10 0.049 0.08 1718.31 0.000 Pole Interaction Design Data Section No. Elevation ft Ratio Pu φPn Ratio Mux φMnx Ratio Muy φMny Ratio Vu φVn Ratio Tu φTn Comb. Stress Ratio Allow. Stress Ratio Criteria L1 140 - 130 (1) 0.007 0.065 0.000 0.020 0.000 0.072 1.050 4.8.2 L2 130 - 100 (2) 0.021 0.521 0.000 0.053 0.000 0.545 1.050 4.8.2 L3 100 - 80 (3) 0.020 0.702 0.000 0.044 0.000 0.723 1.050 4.8.2 L4 80 - 60 (4) 0.023 0.799 0.000 0.046 0.000 0.824 1.050 4.8.2 L5 60 - 40 (5) 0.023 0.830 0.000 0.048 0.000 0.856 1.050 4.8.2 L6 40 - 20 (6) 0.024 0.831 0.000 0.048 0.000 0.857 1.050 4.8.2 L7 20 - 0 (7) 0.025 0.818 0.000 0.049 0.000 0.845 1.050 4.8.2 ° Twist ° Radius of Curvature ft 138.00 Side Arm Mount [SO 102-3] 2 63.159 3.9884 0.0053 29876 135.00 (2) JAHH-65C-R3B w/ Mount Pipe 2 60.655 3.9851 0.0050 29876 133.00 Walkway (3) 2 58.987 3.9800 0.0047 21042 132.00 Side Arm Mount [SO 102-3] 2 58.154 3.9762 0.0046 17923 123.00 8' Pipe Mount [#2.0 STD] 2 50.705 3.8898 0.0035 4978 114.00 MX08FRO665-21 w/ Mount Pipe 2 43.453 3.7152 0.0023 2679 101.00 7750.00 w/ Mount Pipe 2 33.666 3.3433 0.0011 1626 80.00 P65-16-XLPP-RR w/ Mount Pipe 2 20.460 2.5764 0.0006 1527 Compression Checks Pole Design Data Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K φPn K Ratio Pu φPn L1 140 - 130 (1) P18x3/8 10.00 0.00 0.0 20.764 0 -5.75 859.63 0.007 L2 130 - 100 (2) P24x3/8 30.00 0.00 0.0 27.832 5 -22.06 1052.07 0.021 L3 100 - 80 (3) P30x3/8 20.00 0.00 0.0 34.901 1 -25.67 1311.06 0.020 L4 80 - 60 (4) P36x3/8 20.00 0.00 0.0 41.969 7 -34.05 1490.10 0.023 L5 60 - 40 (5) P42x3/8 20.00 0.00 0.0 49.038 -38.95 1668.87 0.023 48 Yes 4 0.00000001 0.00022219 49 Yes 4 0.00000001 0.00070539 50 Yes 4 0.00000001 0.00068095 Maximum Tower Deflections - Service Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 140 - 130 16.471 39 1.0131 0.0014 L2 130 - 100 14.352 39 1.0069 0.0012 L3 100 - 80 8.374 39 0.8403 0.0003 L4 80 - 60 5.199 39 0.6542 0.0002 L5 60 - 40 2.821 39 0.4665 0.0001 L6 40 - 20 1.212 39 0.2925 0.0001 L7 20 - 0 0.298 39 0.1372 0.0000 22 -19.83 -50.48 -11.51 19.83 50.48 11.51 0.000% 23 -19.83 -37.86 -11.51 19.83 37.86 11.51 0.000% 24 -11.45 -50.48 -19.93 11.45 50.48 19.93 0.000% 25 -11.45 -37.86 -19.93 11.45 37.86 19.93 0.000% 26 0.00 -101.28 0.00 -0.00 101.28 0.00 0.000% 27 -0.00 -101.28 -5.54 0.00 101.28 5.54 0.000% 28 2.76 -101.28 -4.80 -2.76 101.28 4.80 0.000% 29 4.79 -101.28 -2.77 -4.79 101.28 2.77 0.000% 30 5.53 -101.28 0.00 -5.53 101.28 -0.00 0.000% 31 4.79 -101.28 2.77 -4.79 101.28 -2.77 0.000% 32 2.76 -101.28 4.80 -2.76 101.28 -4.80 0.000% 33 0.00 -101.28 5.54 -0.00 101.28 -5.54 0.000% 34 -2.76 -101.28 4.80 2.76 101.28 -4.80 0.000% 35 -4.79 -101.28 2.77 4.79 101.28 -2.77 0.000% 36 -5.53 -101.28 -0.00 5.53 101.28 0.00 0.000% 37 -4.79 -101.28 -2.77 4.79 101.28 2.77 0.000% 38 -2.76 -101.28 -4.80 2.76 101.28 4.80 0.000% 39 -0.00 -42.07 -5.90 0.00 42.07 5.90 0.000% 40 2.94 -42.07 -5.11 -2.94 42.07 5.11 0.000% 41 5.09 -42.07 -2.95 -5.09 42.07 2.95 0.000% 42 5.87 -42.07 0.00 -5.87 42.07 -0.00 0.000% 43 5.09 -42.07 2.95 -5.09 42.07 -2.95 0.000% 44 2.94 -42.07 5.11 -2.94 42.07 -5.11 0.000% 45 0.00 -42.07 5.90 -0.00 42.07 -5.90 0.000% 46 -2.94 -42.07 5.11 2.94 42.07 -5.11 0.000% 47 -5.09 -42.07 2.95 5.09 42.07 -2.95 0.000% 48 -5.87 -42.07 -0.00 5.87 42.07 0.00 0.000% 49 -5.09 -42.07 -2.95 5.09 42.07 2.95 0.000% 50 -2.94 -42.07 -5.11 2.94 42.07 5.11 0.000% 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 101.28 -0.00 -5.54 -614.04 -7.20 0.02 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 101.28 2.76 -4.80 -532.05 -312.16 -0.03 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 101.28 4.79 -2.77 -308.10 -535.43 -0.07 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 101.28 5.53 0.00 -2.21 -617.18 -0.09 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 101.28 4.79 2.77 303.66 -535.50 -0.08 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 101.28 2.76 4.80 527.56 -312.28 -0.06 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 101.28 0.00 5.54 609.48 -7.34 -0.02 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 101.28 -2.76 4.80 527.49 297.62 0.03 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 101.28 -4.79 2.77 303.54 520.89 0.07 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 101.28 -5.53 -0.00 -2.35 602.63 0.09 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 101.28 -4.79 -2.77 -308.22 520.96 0.08 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 101.28 -2.76 -4.80 -532.12 297.74 0.06 Dead+Wind 0 deg - Service 42.07 -0.00 -5.90 -606.03 -1.09 0.02 Dead+Wind 30 deg - Service 42.07 2.94 -5.11 -524.83 -302.32 -0.01 Dead+Wind 60 deg - Service 42.07 5.09 -2.95 -303.09 -522.86 -0.04 Dead+Wind 90 deg - Service 42.07 5.87 0.00 -0.23 -603.63 -0.06 Dead+Wind 120 deg - Service 42.07 5.09 2.95 302.59 -522.97 -0.06 Dead+Wind 150 deg - Service 42.07 2.94 5.11 524.25 -302.51 -0.05 Dead+Wind 180 deg - Service 42.07 0.00 5.90 605.34 -1.31 -0.02 Dead+Wind 210 deg - Service 42.07 -2.94 5.11 524.14 299.92 0.01 Dead+Wind 240 deg - Service 42.07 -5.09 2.95 302.40 520.47 0.04 Dead+Wind 270 deg - Service 42.07 -5.87 -0.00 -0.45 601.23 0.06 Dead+Wind 300 deg - Service 42.07 -5.09 -2.95 -303.28 520.58 0.06 Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft Dead Only 42.07 0.00 0.00 -0.31 -1.15 0.00 1.2 Dead+1.0 Wind 0 deg - No Ice 50.48 -0.00 -23.01 -2381.19 -1.01 0.08 0.9 Dead+1.0 Wind 0 deg - No Ice 37.86 -0.00 -23.01 -2350.76 -0.64 0.08 1.2 Dead+1.0 Wind 30 deg - No Ice 50.48 11.45 -19.92 -2062.01 -1185.06 -0.04 0.9 Dead+1.0 Wind 30 deg - No Ice 37.86 11.45 -19.92 -2035.66 -1169.62 -0.03 1.2 Dead+1.0 Wind 60 deg - No Ice 50.48 19.83 -11.50 -1190.43 -2051.96 -0.15 0.9 Dead+1.0 Wind 60 deg - No Ice 37.86 19.83 -11.50 -1175.18 -2025.50 -0.14 1.2 Dead+1.0 Wind 90 deg - No Ice 50.48 22.90 0.00 0.01 -2369.43 -0.22 0.9 Dead+1.0 Wind 90 deg - No Ice 37.86 22.90 0.00 0.12 -2338.92 -0.21 1.2 Dead+1.0 Wind 120 deg - No Ice 50.48 19.83 11.51 1190.35 -2052.39 -0.23 0.9 Dead+1.0 Wind 120 deg - No Ice 37.86 19.83 11.51 1175.31 -2025.92 -0.23 1.2 Dead+1.0 Wind 150 deg - No Ice 50.48 11.45 19.93 2061.61 -1185.81 -0.18 Max. Compression 26 -54.90 -1.28 2.12 Max. Mx 8 -22.08 -323.19 0.31 Max. My 2 -22.06 -0.08 325.16 Max. Vy 8 16.47 -323.19 0.31 Max. Vx 2 -16.58 -0.08 325.16 Max. Torque 8 0.72 L3 100 - 80 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 26 -60.41 -2.33 2.77 Max. Mx 8 -25.68 -661.01 0.37 Max. My 2 -25.67 -0.21 665.17 Max. Vy 8 17.27 -661.01 0.37 Max. Vx 2 -17.39 -0.21 665.17 Max. Torque 10 0.23 L4 80 - 60 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 26 -77.03 -3.54 2.73 Max. Mx 8 -34.05 -1064.03 0.27 Max. My 2 -34.05 -0.36 1070.16 Max. Vy 8 20.57 -1064.03 0.27 Max. Vx 2 -20.68 -0.36 1070.16 Max. Torque 10 0.23 L5 60 - 40 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 26 -84.52 -4.69 2.58 Max. Mx 8 -38.96 -1483.85 0.18 Max. My 2 -38.95 -0.55 1491.92 Max. Vy 8 21.37 -1483.85 0.18 Max. Vx 2 -21.48 -0.55 1491.92 Max. Torque 10 0.23 3.07 4.01 5.13 2.14 3.07 4.01 5.13 0.07 0.08 0.10 0.17 Platform Mount [LP 405- 1_HR-1] C None 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 25.33 33.79 42.16 58.77 25.33 33.79 42.16 58.77 2.06 2.63 3.36 5.25 *** M-MIMO AAU A From Leg 4.00 0.00 -1.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 6.79 7.13 7.48 8.20 2.24 2.50 2.77 3.32 0.14 0.18 0.23 0.33 M-MIMO AAU B From Leg 4.00 0.00 -1.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 6.79 7.13 7.48 8.20 2.24 2.50 2.77 3.32 0.14 0.18 0.23 0.33 M-MIMO AAU C From Leg 4.00 0.00 -1.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 6.79 7.13 7.48 8.20 2.24 2.50 2.77 3.32 0.14 0.18 0.23 0.33 ****** Load Combinations Comb. No. Description 1 Dead Only 2 1.2 Dead+1.0 Wind 0 deg - No Ice 3 0.9 Dead+1.0 Wind 0 deg - No Ice 4 1.2 Dead+1.0 Wind 30 deg - No Ice 5 0.9 Dead+1.0 Wind 30 deg - No Ice 6 1.2 Dead+1.0 Wind 60 deg - No Ice 7 0.9 Dead+1.0 Wind 60 deg - No Ice 8 1.2 Dead+1.0 Wind 90 deg - No Ice 9 0.9 Dead+1.0 Wind 90 deg - No Ice 10 1.2 Dead+1.0 Wind 120 deg - No Ice 11 0.9 Dead+1.0 Wind 120 deg - No Ice 12 1.2 Dead+1.0 Wind 150 deg - No Ice 13 0.9 Dead+1.0 Wind 150 deg - No Ice 14 1.2 Dead+1.0 Wind 180 deg - No Ice 15 0.9 Dead+1.0 Wind 180 deg - No Ice 16 1.2 Dead+1.0 Wind 210 deg - No Ice 17 0.9 Dead+1.0 Wind 210 deg - No Ice 18 1.2 Dead+1.0 Wind 240 deg - No Ice 19 0.9 Dead+1.0 Wind 240 deg - No Ice 20 1.2 Dead+1.0 Wind 270 deg - No Ice 21 0.9 Dead+1.0 Wind 270 deg - No Ice 22 1.2 Dead+1.0 Wind 300 deg - No Ice 23 0.9 Dead+1.0 Wind 300 deg - No Ice 24 1.2 Dead+1.0 Wind 330 deg - No Ice 2.95 3.17 3.63 1.79 1.97 2.16 2.57 0.06 0.08 0.11 0.17 RRH-P4 C From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.74 2.95 3.17 3.63 1.79 1.97 2.16 2.57 0.06 0.08 0.11 0.17 RRH-C2A W/EXT FILTER A From Leg 4.00 0.00 -2.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.11 3.33 3.56 4.05 1.38 1.55 1.72 2.09 0.06 0.08 0.10 0.16 RRH-C2A W/EXT FILTER B From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.11 3.33 3.56 4.05 1.38 1.55 1.72 2.09 0.06 0.08 0.10 0.16 RRH-C2A W/EXT FILTER C From Leg 4.00 0.00 -2.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.11 3.33 3.56 4.05 1.38 1.55 1.72 2.09 0.06 0.08 0.10 0.16 4.5' x 2'' Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.02 1.30 1.58 2.17 1.02 1.30 1.58 2.17 0.00 0.01 0.02 0.05 4.5' x 2'' Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.02 1.30 1.58 2.17 1.02 1.30 1.58 2.17 0.00 0.01 0.02 0.05 4.5' x 2'' Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.02 1.30 1.58 2.17 1.02 1.30 1.58 2.17 0.00 0.01 0.02 0.05 (2) 7'x2'' Antenna Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.66 2.39 2.83 3.71 1.66 2.39 2.83 3.71 0.03 0.04 0.06 0.10 (2) 7'x2'' Antenna Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.66 2.39 2.83 3.71 1.66 2.39 2.83 3.71 0.03 0.04 0.06 0.10 (2) 7'x2'' Antenna Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.66 2.39 2.83 3.71 1.66 2.39 2.83 3.71 0.03 0.04 0.06 0.10 9' x 2'' Pipe Mount A From Leg 4.00 0.00 0.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2.14 3.07 4.01 5.13 2.14 3.07 4.01 5.13 0.07 0.08 0.10 0.17 1.97 2.14 2.33 2.72 1.41 1.56 1.73 2.07 0.07 0.09 0.11 0.16 RRUS 4449 B5/B12 B From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.97 2.14 2.33 2.72 1.41 1.56 1.73 2.07 0.07 0.09 0.11 0.16 RRUS 4449 B5/B12 C From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.97 2.14 2.33 2.72 1.41 1.56 1.73 2.07 0.07 0.09 0.11 0.16 RRUS 4478 B14 A From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.84 2.01 2.19 2.57 1.06 1.20 1.34 1.66 0.06 0.08 0.09 0.14 RRUS 4478 B14 B From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.84 2.01 2.19 2.57 1.06 1.20 1.34 1.66 0.06 0.08 0.09 0.14 RRUS 4478 B14 C From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.84 2.01 2.19 2.57 1.06 1.20 1.34 1.66 0.06 0.08 0.09 0.14 DC6-48-60-18-8F A From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.92 1.46 1.64 2.04 0.92 1.46 1.64 2.04 0.02 0.04 0.06 0.11 DC9-48-60-24-8C-EV B From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.74 2.96 3.20 3.68 4.78 5.06 5.35 5.95 0.03 0.06 0.10 0.20 DC9-48-60-24-8C-EV C From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.74 2.96 3.20 3.68 4.78 5.06 5.35 5.95 0.03 0.06 0.10 0.20 ****** P65-16-XLPP-RR w/ Mount Pipe A From Leg 4.00 0.00 -1.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 5.66 6.21 6.76 7.90 4.01 4.53 5.06 6.15 0.08 0.14 0.21 0.39 P65-16-XLPP-RR w/ Mount Pipe B From Leg 4.00 0.00 -1.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 5.66 6.21 6.76 7.90 4.01 4.53 5.06 6.15 0.08 0.14 0.21 0.39 P90-15-XLPP-RR w/ Mount Pipe C From Leg 4.00 0.00 -1.00 0.0000 80.00 No Ice 1/2'' Ice 1'' Ice 5.66 6.21 6.76 7.90 4.01 4.53 5.06 6.15 0.08 0.14 0.21 0.38 1.50 1.88 2.35 3.52 ****** AIR 6449 N77 w/ Mount Pipe A From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.65 3.99 4.35 5.11 2.72 3.03 3.36 4.05 0.11 0.15 0.20 0.31 AIR 6449 N77 w/ Mount Pipe B From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.65 3.99 4.35 5.11 2.72 3.03 3.36 4.05 0.11 0.15 0.20 0.31 AIR 6449 N77 w/ Mount Pipe C From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.65 3.99 4.35 5.11 2.72 3.03 3.36 4.05 0.11 0.15 0.20 0.31 AIR 6419 B77G w/ Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 4.32 4.74 5.17 6.09 2.49 2.84 3.21 4.00 0.08 0.11 0.15 0.24 AIR 6419 B77G w/ Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 4.32 4.74 5.17 6.09 2.49 2.84 3.21 4.00 0.08 0.11 0.15 0.24 AIR 6419 B77G w/ Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 4.32 4.74 5.17 6.09 2.49 2.84 3.21 4.00 0.08 0.11 0.15 0.24 XXQLH-654L8H8-IVT-V2 w/ Mount Pipe A From Leg 4.00 0.00 -1.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 11.80 12.52 13.25 14.75 5.99 6.65 7.32 8.70 0.15 0.26 0.38 0.67 XXQLH-654L8H8-IVT-V2 w/ Mount Pipe B From Leg 4.00 0.00 -1.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 11.80 12.52 13.25 14.75 5.99 6.65 7.32 8.70 0.15 0.26 0.38 0.67 XXQLH-654L8H8-IVT-V2 w/ Mount Pipe C From Leg 4.00 0.00 -1.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 11.80 12.52 13.25 14.75 5.99 6.65 7.32 8.70 0.15 0.26 0.38 0.67 XXQLH-654L8H8-IVT-V2 w/ Mount Pipe A From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 11.80 12.52 13.25 14.75 5.99 6.65 7.32 8.70 0.15 0.26 0.38 0.67 XXQLH-654L8H8-IVT-V2 w/ Mount Pipe B From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 11.80 12.52 13.25 14.75 5.99 6.65 7.32 8.70 0.15 0.26 0.38 0.67 7.16 0.06 0.10 0.16 0.29 RRUS 32 B66 A From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.74 2.96 3.19 3.68 1.67 1.86 2.05 2.46 0.05 0.07 0.10 0.16 RRUS 32 B66 B From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.74 2.96 3.19 3.68 1.67 1.86 2.05 2.46 0.05 0.07 0.10 0.16 RRUS 32 B66 C From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.74 2.96 3.19 3.68 1.67 1.86 2.05 2.46 0.05 0.07 0.10 0.16 RRUS 32 B2 A From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.73 2.95 3.18 3.66 1.67 1.86 2.05 2.46 0.05 0.07 0.10 0.16 RRUS 32 B2 B From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.73 2.95 3.18 3.66 1.67 1.86 2.05 2.46 0.05 0.07 0.10 0.16 RRUS 32 B2 C From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.73 2.95 3.18 3.66 1.67 1.86 2.05 2.46 0.05 0.07 0.10 0.16 RRUS 32 B30 A From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.69 2.91 3.14 3.61 1.57 1.76 1.95 2.35 0.06 0.08 0.10 0.16 RRUS 32 B30 B From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.69 2.91 3.14 3.61 1.57 1.76 1.95 2.35 0.06 0.08 0.10 0.16 RRUS 32 B30 C From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.69 2.91 3.14 3.61 1.57 1.76 1.95 2.35 0.06 0.08 0.10 0.16 (2) LGP21404 A From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.10 1.24 1.38 1.69 0.35 0.44 0.54 0.77 0.01 0.02 0.03 0.05 (2) LGP21404 B From Leg 4.00 0.00 2.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.10 1.24 1.38 1.69 0.35 0.44 0.54 0.77 0.01 0.02 0.03 0.05 (2) LGP21404 C From Leg 4.00 0.0000 101.00 No Ice 1.10 0.35 0.01 2'' Ice 1.96 2.14 2.32 2.71 0.98 1.11 1.25 1.55 0.06 0.08 0.10 0.15 TA08025-B604 C From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.96 2.14 2.32 2.71 0.98 1.11 1.25 1.55 0.06 0.08 0.10 0.15 TA08025-B605 A From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.96 2.14 2.32 2.71 1.13 1.27 1.41 1.72 0.08 0.09 0.11 0.16 TA08025-B605 B From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.96 2.14 2.32 2.71 1.13 1.27 1.41 1.72 0.08 0.09 0.11 0.16 TA08025-B605 C From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.96 2.14 2.32 2.71 1.13 1.27 1.41 1.72 0.08 0.09 0.11 0.16 RDIDC-9181-PF-48 A From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.01 2.19 2.37 2.76 1.17 1.31 1.46 1.78 0.02 0.04 0.06 0.11 (2) 8' x 2'' Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.90 2.73 3.40 4.40 1.90 2.73 3.40 4.40 0.03 0.04 0.06 0.12 (2) 8' x 2'' Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.90 2.73 3.40 4.40 1.90 2.73 3.40 4.40 0.03 0.04 0.06 0.12 (2) 8' x 2'' Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.90 2.73 3.40 4.40 1.90 2.73 3.40 4.40 0.03 0.04 0.06 0.12 Commscope MC-PK8-DSH C None 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 34.24 62.95 91.66 149.08 34.24 62.95 91.66 149.08 1.75 2.10 2.45 3.15 ****** ****** 7750.00 w/ Mount Pipe A From Leg 4.00 0.00 3.00 0.0000 101.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 5.75 6.18 6.61 7.49 4.25 5.01 5.71 7.16 0.06 0.10 0.16 0.29 7750.00 w/ Mount Pipe B From Leg 4.00 0.0000 101.00 No Ice 5.75 4.25 0.06 7.40 7.91 8.99 2.77 3.15 3.55 4.39 0.11 0.16 0.22 0.36 AHFIG_TMO A From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.08 3.32 3.56 4.07 1.47 1.66 1.85 2.27 0.07 0.09 0.12 0.18 AHFIG_TMO B From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.08 3.32 3.56 4.07 1.47 1.66 1.85 2.27 0.07 0.09 0.12 0.18 AHFIG_TMO C From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.08 3.32 3.56 4.07 1.47 1.66 1.85 2.27 0.07 0.09 0.12 0.18 AHLOA_T-MOBILE A From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.86 3.08 3.31 3.80 1.85 2.04 2.23 2.65 0.08 0.11 0.13 0.20 AHLOA_T-MOBILE B From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.86 3.08 3.31 3.80 1.85 2.04 2.23 2.65 0.08 0.11 0.13 0.20 AHLOA_T-MOBILE C From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 2.86 3.08 3.31 3.80 1.85 2.04 2.23 2.65 0.08 0.11 0.13 0.20 HCS 2.0 A From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.94 1.08 1.22 1.53 0.70 0.82 0.94 1.22 0.00 0.01 0.02 0.05 HCS 2.0 B From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.94 1.08 1.22 1.53 0.70 0.82 0.94 1.22 0.00 0.01 0.02 0.05 ****** MX08FRO665-21 w/ Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 8.01 8.52 9.04 10.11 4.23 4.69 5.16 6.12 0.11 0.19 0.29 0.52 MX08FRO665-21 w/ Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 8.01 8.52 9.04 10.11 4.23 4.69 5.16 6.12 0.11 0.19 0.29 0.52 MX08FRO665-21 w/ Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 114.00 No Ice 1/2'' Ice 8.01 8.52 9.04 4.23 4.69 5.16 0.11 0.19 0.29 0.14 0.20 Sector Mount [SM 502-3] C None 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 29.82 42.21 54.43 78.49 29.82 42.21 54.43 78.49 1.67 2.27 3.05 5.18 ****** 8' Pipe Mount [#2.0 STD] A From Leg 4.00 0.00 0.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.90 2.73 3.40 4.40 1.90 2.73 3.40 4.40 0.03 0.04 0.06 0.12 8' Pipe Mount [#2.0 STD] B From Leg 4.00 0.00 0.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.90 2.73 3.40 4.40 1.90 2.73 3.40 4.40 0.03 0.04 0.06 0.12 8' Pipe Mount [#2.0 STD] C From Leg 4.00 0.00 0.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.90 2.73 3.40 4.40 1.90 2.73 3.40 4.40 0.03 0.04 0.06 0.12 Support Rail Kit [HRK 14] C None 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 6.01 8.27 10.20 15.05 5.19 7.14 9.15 12.99 0.44 0.54 0.68 0.85 Handrail Reinforcement Kit[#PRK-SFS-L] C None 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 11.84 16.96 22.08 32.32 11.84 16.96 22.08 32.32 0.28 0.30 0.32 0.36 Platform Mount [LP 404-1] C None 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 24.60 31.63 38.37 51.53 24.60 31.63 38.37 51.53 2.04 2.60 3.29 5.06 *** FFVV-65C-R3-V1_TMO w/ Mount Pipe A From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 12.97 13.62 14.27 15.62 6.20 6.77 7.36 8.57 0.16 0.29 0.44 0.79 FFVV-65C-R3-V1_TMO w/ Mount Pipe B From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 12.97 13.62 14.27 15.62 6.20 6.77 7.36 8.57 0.16 0.29 0.44 0.79 FFVV-65C-R3-V1_TMO w/ Mount Pipe C From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 12.97 13.62 14.27 15.62 6.20 6.77 7.36 8.57 0.16 0.29 0.44 0.79 AEHC w/ Mount Pipe A From Leg 4.00 0.00 1.00 0.0000 123.00 No Ice 1/2'' Ice 1'' Ice 6.91 7.40 7.91 8.99 2.77 3.15 3.55 4.39 0.11 0.16 0.22 0.36 3.24 0.09 0.11 0.15 0.22 RADIO 8843 C From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.50 3.74 3.99 4.51 2.36 2.57 2.78 3.24 0.09 0.11 0.15 0.22 RADIO 4449 A From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.50 3.74 3.99 4.51 2.36 2.57 2.78 3.24 0.09 0.11 0.15 0.22 RADIO 4449 B From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.50 3.74 3.99 4.51 2.36 2.57 2.78 3.24 0.09 0.11 0.15 0.22 RADIO 4449 C From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.50 3.74 3.99 4.51 2.36 2.57 2.78 3.24 0.09 0.11 0.15 0.22 RRODC-6627-PF-48 A From Leg 4.00 0.00 1.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 4.06 4.32 4.58 5.14 3.10 3.34 3.58 4.09 0.03 0.07 0.11 0.20 5' x 2'' Pipe Mount A From Leg 2.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.19 1.50 1.81 2.46 1.19 1.50 1.81 2.46 0.02 0.03 0.04 0.08 (3) 8' x 2'' Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.90 2.73 3.40 4.40 1.90 2.73 3.40 4.40 0.03 0.04 0.06 0.12 (3) 8' x 2'' Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.90 2.73 3.40 4.40 1.90 2.73 3.40 4.40 0.03 0.04 0.06 0.12 (3) 8' x 2'' Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 1.90 2.73 3.40 4.40 1.90 2.73 3.40 4.40 0.03 0.04 0.06 0.12 Walkway (3) C None 0.0000 133.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 10.54 13.60 16.66 22.78 10.54 13.60 16.66 22.78 0.32 0.47 0.63 0.93 Pipe Mount [PM 602-3] C None 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 6.67 7.70 8.74 10.90 6.67 7.70 8.74 10.90 0.28 0.34 0.42 0.63 Side Arm Mount [SO 102- C None 0.0000 138.00 No Ice 3.60 3.60 0.07 1/2'' Ice 1'' Ice 2'' Ice 6.60 7.14 7.69 8.83 5.11 5.63 6.17 7.27 0.12 0.21 0.32 0.57 (2) JAHH-65C-R3B w/ Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 6.60 7.14 7.69 8.83 5.11 5.63 6.17 7.27 0.12 0.21 0.32 0.57 AIR6449 A From Leg 4.00 0.00 2.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.70 4.06 4.44 5.23 2.14 2.45 2.78 3.48 0.10 0.13 0.17 0.26 AIR6449 B From Leg 4.00 0.00 2.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.70 4.06 4.44 5.23 2.14 2.45 2.78 3.48 0.10 0.13 0.17 0.26 AIR6449 C From Leg 4.00 0.00 2.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 3.70 4.06 4.44 5.23 2.14 2.45 2.78 3.48 0.10 0.13 0.17 0.26 4408 W/KRE 105 281/1 A From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.80 1.02 1.26 1.82 0.10 0.23 0.38 0.76 0.00 0.00 0.01 0.02 4408 W/KRE 105 281/1 B From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.80 1.02 1.26 1.82 0.10 0.23 0.38 0.76 0.00 0.00 0.01 0.02 4408 W/KRE 105 281/1 C From Leg 4.00 0.00 0.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.80 1.02 1.26 1.82 0.10 0.23 0.38 0.76 0.00 0.00 0.01 0.02 CBC78T-DS-43-2X A From Leg 4.00 0.00 1.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.37 0.45 0.53 0.72 0.51 0.60 0.70 0.93 0.02 0.03 0.04 0.06 CBC78T-DS-43-2X B From Leg 4.00 0.00 1.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.37 0.45 0.53 0.72 0.51 0.60 0.70 0.93 0.02 0.03 0.04 0.06 CBC78T-DS-43-2X C From Leg 4.00 0.00 1.00 0.0000 135.00 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.37 0.45 0.53 0.72 0.51 0.60 0.70 0.93 0.02 0.03 0.04 0.06 RADIO 8843 A From Leg 4.00 0.0000 135.00 No Ice 3.50 2.36 0.09 L5 1 Safety Line 3/8 40.00 - 60.00 1.0000 1.0000 L5 2 Climbing Rung 40.00 - 60.00 1.0000 1.0000 L5 9 HCS 2.0 Part 3(1-1/2) 40.00 - 60.00 1.0000 1.0000 L5 11 CU12PSM6P4XXX(1-3/4) 40.00 - 60.00 1.0000 1.0000 L5 29 SPRINT NMP_HYBRID CABLE(1-1/2) 40.00 - 60.00 1.0000 1.0000 L5 31 942-98886-1FXXX(1-1/8) 40.00 - 60.00 1.0000 1.0000 L6 1 Safety Line 3/8 20.00 - 40.00 1.0000 1.0000 L6 2 Climbing Rung 20.00 - 40.00 1.0000 1.0000 L6 9 HCS 2.0 Part 3(1-1/2) 20.00 - 40.00 1.0000 1.0000 L6 11 CU12PSM6P4XXX(1-3/4) 20.00 - 40.00 1.0000 1.0000 L6 29 SPRINT NMP_HYBRID CABLE(1-1/2) 20.00 - 40.00 1.0000 1.0000 L6 31 942-98886-1FXXX(1-1/8) 20.00 - 40.00 1.0000 1.0000 L7 1 Safety Line 3/8 0.00 - 20.00 1.0000 1.0000 L7 2 Climbing Rung 0.00 - 20.00 1.0000 1.0000 L7 9 HCS 2.0 Part 3(1-1/2) 0.00 - 20.00 1.0000 1.0000 L7 11 CU12PSM6P4XXX(1-3/4) 0.00 - 20.00 1.0000 1.0000 L7 29 SPRINT NMP_HYBRID CABLE(1-1/2) 0.00 - 20.00 1.0000 1.0000 L7 31 942-98886-1FXXX(1-1/8) 0.00 - 20.00 1.0000 1.0000 0.000 0.000 12.450 11.260 0.000 0.000 0.000 0.23 0.18 0.15 L7 20.00-0.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.450 11.260 0.000 0.000 0.000 0.23 0.18 0.15 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Sectio n Tower Elevation ft Face or Leg Ice Thickness in AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 140.00-130.00 A B C 1.957 0.000 0.000 0.000 0.000 0.000 0.000 0.000 4.289 0.000 0.000 0.000 0.000 0.00 0.06 0.02 L2 130.00-100.00 A B C 1.926 0.000 0.000 0.000 0.000 0.000 0.000 0.000 55.068 0.000 0.000 0.000 0.000 0.01 0.92 0.11 L3 100.00-80.00 A B C 1.879 0.000 0.000 0.000 0.000 0.000 0.000 0.000 45.950 0.000 0.000 0.000 0.000 0.23 0.79 0.08 L4 80.00-60.00 A B C 1.833 0.000 0.000 0.000 0.000 0.000 0.000 0.000 45.157 30.005 0.000 0.000 0.000 0.23 0.77 0.53 L5 60.00-40.00 A B C 1.772 0.000 0.000 0.000 0.000 0.000 0.000 0.000 44.126 29.459 0.000 0.000 0.000 0.23 0.74 0.51 L6 40.00-20.00 A B C 1.684 0.000 0.000 0.000 0.000 0.000 0.000 0.000 42.626 28.665 0.000 0.000 0.000 0.23 0.70 0.49 L7 20.00-0.00 A B C 1.509 0.000 0.000 0.000 0.000 0.000 0.000 0.000 39.648 27.088 0.000 0.000 0.000 0.23 0.62 0.44 Feed Line Center of Pressure Section Elevation ft CPX in CPZ in CPX Ice in CPZ Ice in L1 140.00-130.00 0.3675 0.0038 1.5038 0.0157 L2 130.00-100.00 3.3015 -0.9574 4.3123 -0.8851 L3 100.00-80.00 4.3349 -1.3777 5.4029 -1.3252 L4 80.00-60.00 2.1109 1.9936 3.0244 1.6652 L5 60.00-40.00 2.2254 2.1028 3.2520 1.8048 L6 40.00-20.00 2.3207 2.1938 3.4137 1.9178 L7 20.00-0.00 2.4013 2.2706 3.4494 1.9907 Note: For pole sections, center of pressure calculations do not consider feed line shielding. Shielding Factor Ka Tower Section Feed Line Record No. Description Feed Line Segment Elev. Ka No Ice Ka Ice L1 1 Safety Line 3/8 130.00 - 1.0000 1.0000 0.00 0.00 0.00 0.08 0.08 0.08 0.08 LDF5-50A(7/8) A No No Inside Pole 101.00 - 0.00 6 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 0.00 0.00 0.00 0.33 0.33 0.33 0.33 RLSS 8AWG DC(3/4) A No No Inside Pole 101.00 - 0.00 1 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 0.00 0.00 0.00 0.49 0.49 0.49 0.49 RLSS 8AWG DC(3/4) A No No Inside Pole 101.00 - 0.00 1 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 0.00 0.00 0.00 0.49 0.49 0.49 0.49 ****** LDF2-50A(3/8) A No No Inside Pole 101.00 - 0.00 1 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 0.00 0.00 0.00 0.08 0.08 0.08 0.08 RFFT-48SM-001- XXX(3/8) A No No Inside Pole 101.00 - 0.00 2 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 0.00 0.00 0.00 0.06 0.06 0.06 0.06 WR-VG66ST- BRD(7/8) A No No Inside Pole 101.00 - 0.00 6 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 0.00 0.00 0.00 0.91 0.91 0.91 0.91 2'' Rigid Conduit A No No Inside Pole 101.00 - 0.00 1 No Ice 1/2'' Ice 1'' Ice 2'' Ice 0.00 0.00 0.00 0.00 2.80 2.80 2.80 2.80 ****** Feed Line/Linear Appurtenances Section Areas Tower Sectio n Tower Elevation ft Face AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 140.00-130.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.375 0.000 0.000 0.000 0.000 0.00 0.00 0.02 L2 130.00-100.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 13.705 0.000 0.000 0.000 0.000 0.01 0.19 0.11 L3 100.00-80.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.450 0.000 0.000 0.000 0.000 0.23 0.18 0.08 L4 80.00-60.00 A 0.000 0.000 0.000 0.000 0.23 L2 130.00- 100.00 1 1 1 L3 100.00- 80.00 1 1 1 L4 80.00- 60.00 1 1 1 L5 60.00- 40.00 1 1 1 L6 40.00- 20.00 1 1 1 L7 20.00-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Sector Exclude From Torque Calculation Componen t Type Placement ft Total Number Number Per Row Start/En d Position Width or Diamete r in Perimete r in Weight plf Safety Line 3/8 B No Surface Ar (CaAa) 140.00 - 0.00 1 1 0.250 0.260 0.3750 0.22 Climbing Rung B No Surface Ar (CaAa) 130.00 - 0.00 1 1 0.220 0.280 1.0000 0.01 *** HCS 2.0 Part 3(1-1/2) B No Surface Ar (CaAa) 123.00 - 0.00 2 2 0.020 0.080 1.5500 1.71 ****** CU12PSM6P4XXX(1- 3/4) B No Surface Ar (CaAa) 114.00 - 0.00 1 1 0.080 0.090 1.7500 2.72 ****** SPRINT NMP_HYBRID CABLE(1-1/2) C No Surface Ar (CaAa) 80.00 - 0.00 3 3 0.150 0.260 1.5000 1.00 *** 942-98886-1FXXX(1- 1/8) C No Surface Ar (CaAa) 80.00 - 0.00 1 1 0.270 0.280 1.1300 0.88 ****** Pole Grade Socket Length ft L1 140.00-130.00 10.00 P18x3/8 A500-46 (46 ksi) L2 130.00-100.00 30.00 P24x3/8 A53-B-42 3. Tower designed for a 115 mph basic wind in accordance with the TIA-222-H Standard. 4. Tower is also designed for a 40 mph basic wind with 2.00 in ice. Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Risk Category II. 7. Topographic Category 1 with Crest Height of 0.00 ft 8. TOWER RATING: 81.7% telecommunications RRH-P4 1 - Platform Mount [LP 405-1_HR-1] 79.0 2 powerwave technologies P65-16-XLPP-RR w/ Mount Pipe 1 powerwave technologies P90-15-XLPP-RR w/ Mount Pipe 3 samsung telecommunications M-MIMO AAU 78.0 2 samsung telecommunications RRH-C2A W/EXT FILTER 3) ANALYSIS PROCEDURE Table 3 - Documents Provided Document Reference Source 4-GEOTECHNICAL REPORTS 298718 CCISITES 4-TOWER FOUNDATION DRAWINGS/DESIGN/SPECS 63278 CCISITES 4-TOWER MANUFACTURER DRAWINGS 422174 CCISITES 4-TOWER REINFORCEMENT DESIGN/DRAWINGS/DATA 6887320 CCISITES 4-POST-MODIFICATION INSPECTION 7638244 CCISITES technologies LGP21404 101.0 3 ericsson AIR 6419 B77G w/ Mount Pipe 1 - Platform Mount [LP 303-1_HR-1] 100.0 3 ace XXQLH-654L8H8-IVT-V2 w/ Mount Pipe Table 2 - Other Considered Equipment Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 135.0 137.0 3 ericsson AIR6449 2 1-3/8 136.0 3 commscope CBC78T-DS-43-2X 1 raycap RRODC-6627-PF-48 135.0 6 commscope JAHH-65C-R3B w/ Mount Pipe 3 ericsson 4408 W/KRE 105 281/1