Loading...
HomeMy WebLinkAboutIN0099_811039_COLLEGE_MEADOWS_IND085_AT&T_LTE_5C,_BWE_SOFTWARE_CARRIER_FCD_Rev0_11.12.21.pdfIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET T-NUMBER: 1 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 11/12/21 NA YXI 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 AT&T SITE NUMBER: IN0099 BU #: 811039 COLLEGE MEADOWS IND085 750 E. 106TH STREET CARMEL, IN 46280 EXISTING 140'-0" MONOPOLE 1717 S. BOULDER SUITE 300 TULSA, OK 74119 PH: (918) 587-4630 www.btgrp.com 0 PRELIMINARY REVIEW 11/12/21 AT&T SITE NUMBER: AT&T SITE NAME: AT&T FA CODE: AT&T PACE NUMBER: AT&T PROJECT: BUSINESS UNIT #: SITE ADDRESS: COUNTY: SITE TYPE: TOWER HEIGHT: IN0099 COLLEGE MEADOWS IND085 10023959 MRIND052134, MRIND052145, MRIND052134, MRIND052482, MRIND052135, MRIND052125, MRIND054136 LTE 5C, BWE SOFTWARE CARRIER, 5G NR 1SR CBAND, BBU RECONFIGURATION WITH NEW IDS, 4TXRX ANTENNA RETROFIT & 5G NR 1DR-2 811039 HAMILTON MONOPOLE 140'-0" 750 E. 106TH STREET CARMEL, IN 46280 AT&T TOWER ASSET GROUP 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 STRUCTURAL ANALYSIS: DATED: SITE INFORMATION CARRIER/APPLICANT: SHEET # DRAWING INDEX IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET T-NUMBER: 2 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 11/12/21 NA YXI 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 AT&T SITE NUMBER: IN0099 BU #: 811039 COLLEGE MEADOWS IND085 750 E. 106TH STREET CARMEL, IN 46280 EXISTING 140'-0" MONOPOLE 1717 S. BOULDER SUITE 300 TULSA, OK 74119 PH: (918) 587-4630 www.btgrp.com 0 PRELIMINARY REVIEW 11/12/21 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. C-SHEET NUMBER: 1.1 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 11/12/21 NA YXI 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 AT&T SITE NUMBER: IN0099 BU #: 811039 COLLEGE MEADOWS IND085 750 E. 106TH STREET CARMEL, IN 46280 EXISTING 140'-0" MONOPOLE 1717 S. BOULDER SUITE 300 TULSA, OK 74119 PH: (918) 587-4630 www.btgrp.com 0 PRELIMINARY REVIEW 11/12/21 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. C-SHEET NUMBER: 1.2 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 11/12/21 NA YXI 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 AT&T SITE NUMBER: IN0099 BU #: 811039 COLLEGE MEADOWS IND085 750 E. 106TH STREET CARMEL, IN 46280 EXISTING 140'-0" MONOPOLE 1717 S. BOULDER SUITE 300 TULSA, OK 74119 PH: (918) 587-4630 www.btgrp.com 0 PRELIMINARY REVIEW 11/12/21 · IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET C-NUMBER: 2 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 11/12/21 NA YXI 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 AT&T SITE NUMBER: IN0099 BU #: 811039 COLLEGE MEADOWS IND085 750 E. 106TH STREET CARMEL, IN 46280 EXISTING 140'-0" MONOPOLE 1717 S. BOULDER SUITE 300 TULSA, OK 74119 PH: (918) 587-4630 www.btgrp.com 0 PRELIMINARY REVIEW 11/12/21 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET C-NUMBER: 3 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 11/12/21 NA YXI 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 AT&T SITE NUMBER: IN0099 BU #: 811039 COLLEGE MEADOWS IND085 750 E. 106TH STREET CARMEL, IN 46280 EXISTING 140'-0" MONOPOLE 1717 S. BOULDER SUITE 300 TULSA, OK 74119 PH: (918) 587-4630 www.btgrp.com 0 PRELIMINARY REVIEW 11/12/21 FINAL ANTENNA AND FEEDLINE SCHEDULE POS. TECH STATUS AZIMUTH ANTENNA TYPE ANTENNA RAD CENTER MECHANICAL DOWNTILT ELECTRICAL DOWNTILT MAIN COAX SIZE MAIN COAX LENGTH COAX QTY TMA QTY AND MODEL SURGE PROTECTION DC/FIBER CABLES RRHs QTY & MODEL ON TOWER LOCATION DIPLEXER ON TOWER DIPLEXER ON GROUND RET CABLE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET C-NUMBER: 4 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 11/12/21 NA YXI 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 AT&T SITE NUMBER: IN0099 BU #: 811039 COLLEGE MEADOWS IND085 750 E. 106TH STREET CARMEL, IN 46280 EXISTING 140'-0" MONOPOLE 1717 S. BOULDER SUITE 300 TULSA, OK 74119 PH: (918) 587-4630 www.btgrp.com 0 PRELIMINARY REVIEW 11/12/21 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET G-NUMBER: 1 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 11/12/21 NA YXI 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 AT&T SITE NUMBER: IN0099 BU #: 811039 COLLEGE MEADOWS IND085 750 E. 106TH STREET CARMEL, IN 46280 EXISTING 140'-0" MONOPOLE 1717 S. BOULDER SUITE 300 TULSA, OK 74119 PH: (918) 587-4630 www.btgrp.com 0 PRELIMINARY REVIEW 11/12/21 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET G-NUMBER: 2 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 11/12/21 NA YXI 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 AT&T SITE NUMBER: IN0099 BU #: 811039 COLLEGE MEADOWS IND085 750 E. 106TH STREET CARMEL, IN 46280 EXISTING 140'-0" MONOPOLE 1717 S. BOULDER SUITE 300 TULSA, OK 74119 PH: (918) 587-4630 www.btgrp.com 0 PRELIMINARY REVIEW 11/12/21 SHEET DESCRIPTION ELECTRIC PROVIDER: DUKE ENERGY TELCO PROVIDER: T.B.D GROUND ELEVATION: 39° 56' 31.48" -86° 8' 41.03" U FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION OCCUPANCY CLASSIFICATION: A.D.A. COMPLIANCE: MAP/PARCEL #: JURISDICTION: CITY OF CARMEL 17-13-01-03-06-012.000 COLLEGE MEADOWS IND085 HAMILTON AREA OF CONSTRUCTION: EXISTING NAD83 B-2 PROPERTY OWNER: CROWN CASTLE USA INC 2000 CORPORATE DRIVE CANONSBURG, PA 15317 TOWER OWNER: TYPE OF CONSTRUCTION: IIB 844' 750 E. 106TH STREET CARMEL, IN 46280 WESTEL INDIANAPOLIS CO 1010 PINE ST 9E-L-01 SAINT LOUIS, MO 63101 CROWN CASTLE USA INC. SITE NAME: N/A REFERENCE DOCUMENTS: MOUNT ANALYSIS: DATED: B+T GROUP 11/4/21 RFDS REVISION: DATED: V16 8/3/21 ORDER ID: REVISION: 568995 0 LAT/LONG TYPE: LONGITUDE: LATITUDE: CURRENT ZONING: COUNTY: SITE ADDRESS: PROJECT TEAM A&E FIRM: CROWN CASTLE USA INC. DISTRICT CONTACTS: T-1 TITLE SHEET C-1.1 SITE PLAN C-1.2 C-2 C-3 C-4 FINAL EQUIPMENT PLAN FINAL EQUIPMENT SCHEDULE FINAL ELEVATION & ANTENNA PLANS G-1 GROUNDING SCHEMATIC T-2 GENERAL NOTES EQUIPMENT SPECS G-2 GROUNDING DETAILS EDWARD NEISE - PROJECT MANAGER EDWARD.NEISE@CROWNCASTLE.COM TIM FORTUNE - CONSTRUCTION MANAGER TIM.FORTUNE@CROWNCASTLE.COM 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER. APPLICABLE CODES/REFERENCE DOCUMENTS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2012 IBC MECHANICAL 2012 IMC ELECTRICAL 2008 NEC ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 24X36. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. PROJECT DESCRIPTION ATTACHED PLUMBING DIAGRAM LOCATION MAP NO SCALE SITE PHOTO CALL INDIANA ONE CALL (800) 382-5544 CALL 3 WORKING DAYS BEFORE YOU DIG! B+T GROUP 1717 S. BOULDER AVE. TULSA, OK 74119 MARVIN PHILLIPS marvin.phillips@btgrp.com THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. TOWER SCOPE OF WORK: · REMOVE (3) KMW - EPBQ-654L8H8 ANTENNAS · REMOVE (3) KMW - EPBQ-652L8H8 ANTENNAS · REMOVE (3) ERICSSON - RRUS-11 B12 RADIOS · REMOVE (1) DC6-48-60-18-8F PENDANT · REMOVE (1) DC6-48-60-0-8C PENDANT · REMOVE (2) RLSS 8AWG DC TRUNK · REMOVE (1) FB-L98B-034-XXXXXX FIBER TRUNK · INSTALL (6) ERICSSON - AIR6449 N77D+AIR6419 N77G STACKED ANTENNAS WITH INTEGRATED RADIOS · INSTALL (6) ACE - XXQLH-654L8H8-IVT-V2 ANTENNAS · INSTALL (3) ERICSSON - 4449 B5/B12 RADIOS · INSTALL (3) ERICSSON - 4478 B14 RADIOS · INSTALL (1) DC6-48-60-0-8C PENDANT · INSTALL (1) DC9-48-60-24-8C-EV PENDANT · INSTALL (6) WR-VG66ST-BRD DC TRUNK · INSTALL (2) RFFT-48SM-001-XXX FIBER TRUNK GROUND SCOPE OF WORK: · NONE