Loading...
HomeMy WebLinkAbout873710_CARMEL-GRAY_129802_VZW_SUB6_REV_0_11022021_UNCERT.pdfVERIZON SITE NUMBER: VERIZON SITE NAME: SITE TYPE: TOWER HEIGHT: BUSINESS UNIT #: SITE ADDRESS: COUNTY: JURISDICTION: 129802 GN 116TH AND KEYSTONE MONOPOLE 80' 873710 HAMILTON CITY OF CARMEL 11405 N GRAY ROAD CARMEL, IN 46033 VERIZON 5G L-SUB6 - CARRIER ADD IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET T-NUMBER: 1 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 0 11/03/2021 MAS CONSTRUCTION SET CM VERIZON SITE NUMBER: 129802 BU #: 873710 CARMEL-GRAY 11405 N GRAY ROAD CARMEL, IN 46033 EXISTING 80' MONOPOLE 1515 E. WOODFIELD ROAD SCHAUMBURG, IL 60173 GPD GROUP, INC. ® 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 GPD JOB#: 2021724.75.873710.05 NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 22X34. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. STRUCTURAL ANALYSIS: DATED: APPLICABLE CODES/REFERENCE DOCUMENTS SITE INFORMATION CARRIER/APPLICANT: SHEET # DRAWING INDEX IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET T-NUMBER: 2 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 0 11/03/2021 MAS CONSTRUCTION SET CM VERIZON SITE NUMBER: 129802 BU #: 873710 CARMEL-GRAY 11405 N GRAY ROAD CARMEL, IN 46033 EXISTING 80' MONOPOLE 1515 E. WOODFIELD ROAD SCHAUMBURG, IL 60173 GPD GROUP, INC. ® 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 GPD JOB#: 2021724.75.873710.05 CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. 2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND CROWN CASTLE USA INC. STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 5. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE," CED-STD-10294 "STANDARD FOR INSTALLATION OF MOUNTS AND APPURTENANCES," AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET T-NUMBER: 3 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 0 11/03/2021 MAS CONSTRUCTION SET CM VERIZON SITE NUMBER: 129802 BU #: 873710 CARMEL-GRAY 11405 N GRAY ROAD CARMEL, IN 46033 EXISTING 80' MONOPOLE 1515 E. WOODFIELD ROAD SCHAUMBURG, IL 60173 GPD GROUP, INC. ® 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 GPD JOB#: 2021724.75.873710.05 GREENFIELD GROUNDING NOTES: 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90° BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD-WELD TERMINATION POINT. THE EXPOSED END OF IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET C-NUMBER: 1 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 0 11/03/2021 MAS CONSTRUCTION SET CM VERIZON SITE NUMBER: 129802 BU #: 873710 CARMEL-GRAY 11405 N GRAY ROAD CARMEL, IN 46033 EXISTING 80' MONOPOLE 1515 E. WOODFIELD ROAD SCHAUMBURG, IL 60173 GPD GROUP, INC. ® 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 GPD JOB#: 2021724.75.873710.05 SCALE: 1 SITE PLAN 4' 3' 1/4"=1'-0" (FULL SIZE) 1/8"=1'-0" (11x17) 2' 1' 0 4' N (E) VERIZON 11'-6"x15'-0" EQUIPMENT SHELTER (E) 80' MONOPOLE (E) VERIZON GENERATOR ON PAD (E) WOOD FENCE (TYP.) (E) VERIZON ICE BRIDGE SCALE: 1 OVERALL SITE PLAN 1/8"=1'-0" (FULL SIZE) 1/16"=1'-0" 8' 6' 4' 2' 0 8' (11x17) N 44'-2"± 21'-1"± 8'-5"± 12'-6"± 59'-7"± 25'-7"± 34'-0"± 20'-0"± 18'-4"± 33'-2"± 44'-2"± 21'-1"± 33'-11"± 21'-9"± (E) OTHER CARRIER EQUIPMENT PLATFORM (E) OTHER CARRIER EQUIPMENT PAD (E) OTHER CARRIER EQUIPMENT PLATFORM (E) UTILITY H-FRAME (E) UTILITY H-FRAME (E) TRANSFORMER (E) WOOD FENCE (E) OTHER MONOPOLE (E) 80' MONOPOLE (E) OTHER MONOPOLE A A IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET C-NUMBER: 2 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 0 11/03/2021 MAS CONSTRUCTION SET CM VERIZON SITE NUMBER: 129802 BU #: 873710 CARMEL-GRAY 11405 N GRAY ROAD CARMEL, IN 46033 EXISTING 80' MONOPOLE 1515 E. WOODFIELD ROAD SCHAUMBURG, IL 60173 GPD GROUP, INC. ® 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 GPD JOB#: 2021724.75.873710.05 SCALE: 1 FINAL TOWER NOT TO ELEVATION SCALE (E) 80' MONOPOLE (E) VERIZON FEEDLINES TO BE REMOVED (12) COAX CABLES (1-5/8") (N) VERIZON FEEDLINES (1) ROSENBERGER HCH-612489 HYBRID CABLE (1-7/8") (ROUTED PER STRUCTURAL ANALYSIS) INSTALLER NOTES: 1. IT IS THE INSTALLING CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL ANTENNA INFORMATION AGAINST THE RADIO FREQUENCY DATA SHEET PROVIDED BY VERIZON FOR THIS PROJECT. 2. MOUNT HEIGHTS MAY VARY. CONTRACTOR TO VERIFY FINAL MOUNT HEIGHT WITH VERIZON WIRELESS RF PRIOR TO CONSTRUCTION. 3. ANTENNA MOUNTS, ORIENTATION AND TOWER PROFILE ARE DIAGRAMMATIC ONLY. ANTENNA SUPPORT PER STRUCTURE MANUFACTURER AND STRUCTURAL ANALYSIS. ALL EXISTING CONDITIONS TO BE FIELD VERIFIED. VERIZON EQUIPMENT ANTENNA CL: 77' MOUNT CL: 77' NEW VERIZON EQUIPMENT (3) COMMSCOPE - NHHS4-65B-R3B ANTENNAs (3) COMMSCOPE - NHHSS-65B-R2BT4 ANTENNAs (3) BSAMNT-SBS-1-2 SIDE BY SIDE MOUNTs (3) ERICSSON 4408 B48 (NO ANTENNA) RRHs (3) ERICSSON - 4449 RRHs (3) ERICSSON - 8843 RRHs A B A B A B A B A B A B IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET C-NUMBER: 3 REVISION: 0 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 0 11/03/2021 MAS CONSTRUCTION SET CM VERIZON SITE NUMBER: 129802 BU #: 873710 CARMEL-GRAY 11405 N GRAY ROAD CARMEL, IN 46033 EXISTING 80' MONOPOLE 1515 E. WOODFIELD ROAD SCHAUMBURG, IL 60173 GPD GROUP, INC. ® 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 GPD JOB#: 2021724.75.873710.05 SCALE: 1 EXISTING NOT ANTENNA TO SCALE PLAN N SCALE: 2 NEW ANTENNA NOT TO PLAN SCALE N (E) 80' MONOPOLE (E) VERIZON ANTENNA TO BE REMOVED ANDREW - SBNH-1D6565B (3 TOTAL, 1 PER SECTOR) (E) SECTOR MOUNTS TO REMAIN ANTENNA REPLACEMENT 1. CONTRACTOR TO INSPECT THE CONDITION OF EXISTING MOUNTING PIPES, CONFIRM THE FOLLOWING. A. CORROSION. IF MOUNTS ARE FOUND TO BE CORRODED, CONTACT VERIZON REP FOR DIRECTION. B. CHECK CONDITION OF ATTACHMENT BOLTS IF FOUND LOOSE, TIGHTEN TO ORIGINAL SPECIFICATIONS (AISC, TURN OF NUT METHOD). C. IF BOLTS ARE MISSING, REPLACE WITH EQUAL. 2. ALL WORK DEPICTED ON CONSTRUCTION DRAWINGS DESIGNED IN ACCORDANCE WITH 2014 INDIANA BUILDING CODE (2012 IBC). 3. WORK TO BE PERFORMED ON (1) SECTOR AT A TIME. TOWER SCOPE OF WORK · REMOVE (6) ANTENNAS · REMOVE (12) COAX CABLES · INSTALL (6) ANTENNAS · INSTALL (3) SIDE BY SIDE MOUNTS · INSTALL (12) RRUs · INSTALL (1) OVP · INSTALL (1) HYBRID CABLE ALPHA (A) 20° ALPHA (B) 30° ANDREW - SBNH-1D6565B ANDREW - SBNH-1D6565C GAMMA (E) 270° ANDREW - SBNH-1D6565B BETA (C) 150 ° BETA (D) 150 ° ANDREW - SBNH-1D6565B ANDREW - SBNH-1D6565C GAMMA (G) 270° ANDREW - SBNH-1D6565C SEQUENCE OF OPERATION NOTE: WORK TO BE PERFORMED ON (1) SECTOR AT A TIME. TOWER WORK: 1. REMOVE EXISTING ANTENNAS. 2. REMOVE EXISTING RRUs. 3. REMOVE EXISTING TMAs. 4. REMOVE EXISTING OVP. 5. REMOVE EXISTING HYBRID CABLES. 6. REMOVE EXISTING COAX CABLES. 7. INSTALL NEW SIDE BY SIDE MOUNTS. 8. INSTALL NEW ANTENNAS. 9. INSTALL NEW RRUs. 10. INSTALL NEW OVPs 11. INSTALL NEW HYBRID CABLES. (E) VERIZON ANTENNA TO BE REMOVED ANDREW - SBNH-1D6565C (3 TOTAL, 1 PER SECTOR) NEW VERIZON OVP RAYCAP - RRODC-6627-PF-48 (1 TOTAL) (E) 80' MONOPOLE (E) SECTOR MOUNTS TO REMAIN ALPHA (A) 30° COMMSCOPE - NHHS4-65B-R3B GAMMA (F) 270° COMMSCOPE - NHHSS-65B-R2BT4 BETA (C) 150 ° COMMSCOPE - NHHS4-65B-R3B BETA (D) 150 ° COMMSCOPE - NHHSS-65B-R2BT4 ALPHA (B) 30° COMMSCOPE - NHHSS-65B-R2BT4 GAMMA (E) 270° COMMSCOPE - NHHS4-65B-R3B NEW VERIZON ANTENNA COMMSCOPE - NHHS4-65B-R3B (3 TOTAL, 1 PER SECTOR) NEW VERIZON ANTENNA COMMSCOPE - NHHSS-65B-R2BT4 (3 TOTAL, 1 PER SECTOR) NEW VERIZON RRU ERICSSON - 8843 (3 TOTAL, 1 PER SECTOR) NEW VERIZON RRU ERICSSON - 8863 (3 TOTAL, 1 PER SECTOR) NEW VERIZON RRU ERICSSON - 4449 (3 TOTAL, 1 PER SECTOR) NEW VERIZON RRU ERICSSON - 4408 (NO ANTENNA) (3 TOTAL, 1 PER SECTOR) NEW VERIZON MOUNT COMMSCOPE - BSAMNT-SBS-1-2 (3 TOTAL, 1 PER SECTOR) 11/03/2021 (3) ERICSSON - 8863 RRHs (1) RAYCAP - RRODC-6627-PF-48 OVP 11/03/2021 (E) UTILITY H-FRAME (E) HUB (E) HUB (E) VERIZON 11'-6"x15'-0" EQUIPMENT SHELTER (E) VERIZON GENERATOR ON PAD (E) VERIZON EQUIPMENT TO BE REMOVED IN SHELTER (3) ERICSSON - RRUS11 B13+A2 (3) ERICSSON - RRUS12 B4+A2 (6) DIPLEXERS (N) VERIZON EQUIPMENT IN SHELTER (1) ERICSSON - BB6630 (1) ERICSSON - BB6648 (E) HUB (E) HUB 11/03/2021 THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). 120/240V, 1Ø SYSTEM A PHASE CONDUCTOR COLOR B PHASE BLACK RED NEUTRAL WHITE GROUND GREEN CONDUCTOR COLOR CODE ELECTRICAL INSTALLATION NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI-CONDUCTOR, TYPE SOOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE (#14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75° C (90° C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL-CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER-ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPOXY-COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPOXY-COATED OR NON-CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "VERIZON". 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. 120/208V, 3Ø A PHASE B PHASE BLACK RED NEUTRAL WHITE GROUND GREEN C PHASE BLUE 277/480V, 3Ø A PHASE B PHASE BROWN ORANGE OR PURPLE NEUTRAL GREY GROUND GREEN C PHASE YELLOW DC VOLTAGE POS (+) RED** NEG (-) BLACK** * SEE NEC 210.5(C)(1) AND (2) ** POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA (E) EXISTING FIF FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM GLOBAL SYSTEM FOR MOBILE LTE LONG TERM EVOLUTION MGB MASTER GROUND BAR MW MICROWAVE (N) NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT QTY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION RET REMOTE ELECTRIC TILT RFDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYP TYPICAL UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT WHITE PROPOSED EXCAVATION TEMPORARY SURVEY MARKINGS ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES GAS, OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS POTABLE WATER RECLAIMED WATER, IRRIGATION, AND SLURRY LINES COMMUNICATION, ALARM OR SIGNAL LINES, CABLES, OR CONDUIT AND TRAFFIC LOOPS SEWERS AND DRAIN LINES APWA UNIFORM COLOR CODE: PINK RED YELLOW BLUE PURPLE ORANGE GREEN 11/03/2021 PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GENERAL NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: VERIZON TOWER OWNER: CROWN CASTLE USA INC. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 11/03/2021 SHEET DESCRIPTION ELECTRIC PROVIDER: DTE ENERGY TELCO PROVIDER: TBD GROUND ELEVATION: 39° 57' 7.46" -86° 05' 16.76" U FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION OCCUPANCY CLASSIFICATION: A.D.A. COMPLIANCE: MAP/PARCEL #: JURISDICTION: CITY OF CARMEL 16-14-04-00-00-003.001 CARMEL-GRAY HAMILTON AREA OF CONSTRUCTION: EXISTING NAD83 S-1 SINGLE FAMILY RESIDENTIAL PROPERTY OWNER: CROWN CASTLE 2000 CORPORATE DRIVE CANONSBURG, PA 15317 TOWER OWNER: TYPE OF CONSTRUCTION: IIB 758 FT. (GOOGLE EARTH) 11405 N GRAY ROAD CARMEL, IN 46033 PSI ENERGY INC DBA CINERGY-PSI 550 S TRYON ST, DEC 41B CHARLOTTE, NC 28202 CROWN CASTLE USA INC. SITE NAME: BY OTHERS REFERENCE DOCUMENTS: ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2014 INDIANA BUILDING CODE (2012 IBC) MECHANICAL 2014 INDIANA MECHANICAL CODE (2012 IMC) ELECTRICAL 2009 INDIANA ELECTRICAL CODE (2008 NEC) PROJECT DESCRIPTION MOUNT ANALYSIS: DATED: BY OTHERS RFDS DATED: 08/09/2021 ORDER ID: REVISION: 592738 1 LAT/LONG TYPE: LONGITUDE: LATITUDE: CURRENT ZONING: COUNTY: SITE ADDRESS: PROJECT TEAM A&E FIRM: CROWN CASTLE USA INC. DISTRICT CONTACTS: T-1 TITLE SHEET C-1 SITE PLAN C-2 FINAL TOWER ELEVATION MICHAEL CLUST - PROJECT MANAGER MICHAEL.CLUST@CROWNCASTLE.COM TBD - CONSTRUCTION MANAGER ---- CORRIE BASS - A&E SPECIALIST CORRIE.BASS@CROWNCASTLE.COM 20 N. MARTINGALE DRIVE, SUITE 440 SCHAUMBURG, IL 60173 VERIZON WIRELESS 180 WASHINGTON VALLEY ROAD BEDMINSTER, NJ 07921 LOCATION MAP NO SCALE T-2 GENERAL NOTES C-3 ANTENNA PLANS & NOTES THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. TOWER SCOPE OF WORK · REMOVE (3) ANDREW - SBNH-1D6565B ANTENNAS · REMOVE (3) ANDREW - SBNH-1D6565C ANTENNAS · REMOVE (12) 1-5/8 COAX CABLES · INSTALL (3) COMMSCOPE - NHHS4-65B-R3B ANTENNAS · INSTALL (3) COMMSCOPE - NHHSS-65B-R2BT4 ANTENNAS · INSTALL (3) COMMSCOPE - BSAMNT-SBS-1-2 MOUNTS · INSTALL (3) ERICSSON - 4408 B48 RRUs (NO ANTENNA) · INSTALL (3) ERICSSON - 4449 RRUs · INSTALL (3) ERICSSON - 8843 RRUs · INSTALL (3) ERICSSON - 8863 RRUs · INSTALL (1) RAYCAP - RRODC-6627-PF-48 OVP BOX · INSTALL (1) ROSENBERGER - HCH-612489 HYBRID CABLE GROUND SCOPE OF WORK · REMOVE (3) ERICSSON - RRUS11 B13+A2 · REMOVE (3) ERICSSON - RRUS12 B4+A2 · REMOVE (6) DIPLEXERS · INSTALL (1) ERICSSON - BB6630 · INSTALL (1) ERICSSON - BB6648 CALL INDIANA ONE CALL (800) 382-5544 CALL 3 WORKING DAYS BEFORE YOU DIG! R CONTRACTOR PMI REQUIREMENTS PMI ACCESSED AT https://pmi.vxwsmart.com N/A SMART TOOL VENDOR PROJECT NUMBER VzW LOCATION CODE (PSLC) 129802 *** PMI AND REQUIREMENTS ALSO EMBEDDED IN MOUNT ANALYSIS REPORT REFER TO MOUNT MODIFICATION DRAWINGS PAGE FOR VzW SMART KIT APPROVED VENDORS VzW APPROVED SMART KIT VENDORS MOUNT MODIFICATION REQUIRED TBD GPD GROUP, INC. 520 SOUTH MAIN STREET, STE 2531 AKRON, OH 44311 PHONE: (330) 572-2100 SITE LOCATION T-3 ELECTRICAL NOTES 11/03/2021