Loading...
HomeMy WebLinkAboutFloor PlanDN UP RESIN TANK RECLAIM TANK WATER HEATER 6" HOUSE-KEEPING PADPULL SECT. DISTR. SECT. MCB LSB PG PASS PA PC PB PDS PD PE SC L2 CONT. L2 L1 CONT. L1 COMPRESSOR RACK WATER SOFT- ENER PHONE BRM-707 1.4 1.4 1 1 2 2 2.1 2.5 2.5 3 3 3.5 3.5 3.9 4 4 5 5 5.4 5.4 6 6 4.4 B B C C D D E E F F G G A A Z Y A201 5 2 3 4 WELLNESS ROOM 406 RESTROOM 407 RESTROOM 408 BREAK ROOM 405 BULK COOLER 305 COLD COOKED PREP 311 KITCHEN 312 OFFICE 400 MEN'S R.R. 402 WOMEN'S R.R. 401 INSTACART 404 CLOSET 403 MEAT & SEAFOOD COOLER 303 BAKERY DELI GROCERY FREEZER 307 ICE CREAM FREEZER 306 MEAT & SEAFOOD FREEZER 308 ELECTRICAL ROOM 501 MEAT & SEAFOOD PREP 304 DAIRY COOLER 300 BAKERY PREP 302 BAKERY COOLER 301 SCULLERY 309 COLD COOKED COOLER 310 PRODUCE PREP 313 PRODUCE COOLER 314 FLORAL COOLER 316 FLORAL PREP 315 FIRE RISER 503 BEER AND WINE SALES 107 16'-6"21'-6"3'-0"17'-0"20'-0"20'-0"20'-0"20'-9"20'-9"13'-0"13'-6" 186'-0"24'-7"16'-5"41'-0"25'-0"24'-0"1'-0"9'-0"2'-0"143'-0"GROCERY SALES 109 FROZEN SALES 110 DAIRY SALES 111 BAKERY SERVICE AISLE 112 BULK/COFFEE/CANDY SALES 108 FLORAL SALES 114 PRODUCE SALES 113 DELI PREP 202 MEAT SERVICE AISLE 203 FRONT END CHECKOUT AREA 101 A402 1 A401 2 1 1/2"12'-8 1/2"14'-0" 9'-0 1/2"8'-7 1/2"8'-8 1/2"14'-11"9'-2"6'-0 1/2"2'-5"5'-4 1/2"111 408407406 202 400401402 100D 100C 100B 315 C22 C21 C20 C19 C17 C16 C15 C14 C13 112 503 502B C11C10 C8 C9 C7 C6 C4C3C2 C5 A6 5'-6 1/2"1'-4"ENTRY/EXIT VESTIBULE 100 RECEIVING 502 BOH 500 BOH CORRIDOOR 504 A200 3 A200 2 A200 4 500 A6C3 C3 ALIGN WALL WITH EXISTING WALL A6 4'-4" A102 1 A400 12 A400 11 A400 10 A400 9 RESTROOM COORIDOR 409 502A 502C IT 413 413 C1 A002 6 14 A503 _______ 2 A501 _______ A500 3 10'-11 1/2"1'-0"2'-9" 403 A400 1 A401 4 2 3 A503 9 501 7 A002 _______ A400 8 A101 2 A101 1 100A A401a 6 A500 3 A500 3 A500 3 A500 3 A500 3 A500 3 MOP SINK 414 A3 UP EXIT VESTIBULE 100A C12 C6 C3 C6 C6 C6 4 54.4 Z Y EXISTING ROOF ACCESS LADDER DN LEGEND PARTITION, REF TAGS COOLER PANEL INSULATION CMU WALL PROJECT NORTH SHEET NO. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper COPYRIGHT NOTICE CONSULTANT PROJECT NO. SHEET TITLE ISSUES & REVISIONS CONSULTANT LOGO DRAWN BY: REBECCA BEASLEY PROFESSIONAL SEAL PROJECT MANAGER: DAN VON SEGGERN DOCUMENT DATE: CHECKED BY: JOHN SCHWEIGER PROJECT NAME PROJECT ADDRESS 12345 ABCDEABCDE12345 TREVOR TYSON HOLCOMB ARCHITECT AR11800234 ARCHITECT OF RECORD: TREVOR TYSON HOLCOMB 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 12/7/2021 12:17:17 PMFLOOR PLANS A100 62930563 12/07/21 THE FRESH MARKET 1392 S. RANGELINE ROAD CARMEL, IN 46032 1/8" = 1'-0"1 FIRST FLOOR PLAN KEYNOTE LEGEND 1.IN CONJUNCTION WITH THEIR TRADE SPECIFIC DRAWINGS, CONTRACTOR IS TO REFER TO RESPONSIBILITY SCHEDULE ON G001 FOR CLARIFICATION OF SCOPE THAT NEEDS TO BE COORDINATED WITHOTHER TRADES. 2.REFER TO A111 FOR INTERIOR SHEATHING OF EXTERIOR WALLS AND PARTITIONS. 3.THE G.C. SHALL BE RESPONSIBLE FOR SUPPLYING AND INSTALLING THE FIRE EXTINGUISHERS AND THE APPROPRIATE BLOCKING WITHIN THE WALL CAVITY. THE ACCEPTABLE MFRS. OF THESE FIRE EXTINGUISHERS ARE AS LISTED IN THE SPECIFICATIONS. THE G.C. SHALL COORDINATE EXACT LOCATION IN THE FIELD WITH THE FRESH MARKET CONSTRUCTION SUPERVISOR AND PER THE LOCATIONS INDICATED ON THE LIFE SAFETY PLAN. THE G.C. SHALL ALSO BE RESPONSIBLE FOR SUPPLYING AND INSTALLING ANY ADDITIONAL FIRE EXTINGUISHERS THAT MAY BE REQUIRED BY THE LOCAL FIRE MARSHAL AND APPLICABLE CODES. INSPECTION TAGS SHALL BE PROVIDED WITH EACH EXTINGUISHER. 4.THE INTENSION OF THE FRESH MARKET IS TO COMPLY WITH ALL REQUIREMENTS SET FORTH IN THE AMERICANS WITH DISABILITY ACT. IF THERE ARE ANY ADDITIONAL REQUIREMENTS FOR FULL COMPLIANCE WITH ADA CODES THAT ARE NOT INCLUDED IN THESE PLANS, IT WILL BE THE RESPONSIBILITY OF THE G.C. TO PROVIDE IMMEDIATE NOTIFICATION TO THE ARCHITECT. 5.ALL DIMENSIONS SHALL BE THOROUGHLY COORDINATED WITH COOLER FLOOR PLAN DIMENSIONS PRIOR TO CONSTRUCTION OF NEW GYPSUM PARTITIONS. 6.G.C. IS RESPONSIBLE FOR ALL CUTTING AND PATCHING OF PENETRATIONS MADE BY TRADES UNDER THEIR CONTROL, WITH THE EXCEPTION OF THE REFRIGERATION CONTRACTOR WHO IS RESPONSIBLE FOR PATCHING THEIR OWN PENETRATIONS. 7.BRACE WALLS IN DIRECTION OPPOSITE CUSTOMER VIEW. 8.G.C TO PROVIDE IN-WALL BLOCKING BEHIND ALL WALL MOUNTED ITEMS -SHELVING, BABY CHANGING STATIONS, WALL DESKS, AND DOOR KNOB DAMAGE AREAS. 9.ALL DIMENSIONS ARE TO FACE OF STUDS, COLUMN CENTER LINES, OR NOMINAL FACE OF MASONRY, UNLESS NOTED OTHERWISE. 10. THE G.C. SHALL GROUT THE GAP BETWEEN THE WALK-IN FREEZERS/COOLERS AND THE EDGE OF THE DEPRESSED SLAB. 11.G.C. TO IS RESPONSIBLE TO PROVIDE ALL SUBSTRATE MATERIAL ENQUIRED BEHIND FINISHES. 12.ALL SURFACES MUST BE SMOOTH AND SEALED, WALL AND FLOORS MUST BE FREE OF DIVETS, DENTS, AND DEFECTS, ETC. 13. ALL INSULATION MATERIAL SHALL BE INSTALLED IN COMPLIANCE WITH THE FRAME SPREAD RATING SMOKE DENSITY REQUIREMENTS OF LOCALLY ADOPTED CODE. 14. THE G.C. SHALL BE RESPONSIBLE FOR HANGING TWO CARE LIABILITY SIGNS ON THE FRONT WALL OF THE STORE. THE BOTTOM OF EACH SIGN SHALL BE MOUNTED 6'-0" A.F.F. SIGNS TO BE PROVIDED BY THE FRESH MARKET. GENERAL NOTES 1/8" = 1'-0"2 MECHANICAL PLATFORM 1.WRAP COLUMNS AT SALES FLOOR WITH M1 UP TO 4'-0" AF.F. PAINT COLUMN W4 FROM 4'-0" A.F.F. TO DECK. 2.6'-0" BY 12" PVC MOUNTED TO COLUMN FROM WIRE BALER WIRE TIES. 3.GC. TO COORDINATE BLOCKING REQUIREMENTS FOR WINE MILLWORK WITH TFM MILLWORK VENDOR. NO. DATE DESCRIPTION