HomeMy WebLinkAboutPM1GENERAL NOTES: A. EVERYTHING SHOWN IS NEW UNLESS OTHERWISE NOTED. B. FOR GENERAL DUCT CONSTRUCTION SEE DETAILS. C. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE, AND SHALL CONFORM WITH ALL FEDERAL, STATE, AND LOCAL CODES AND STANDARDS. D. THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT, AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. E. CONSTRUCTION DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, HOWEVER, SYSTEMS HAVE BEEN SHOWN DIAGRAMMATICALLY AND IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL FITTINGS, AND/OR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR. F. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED MATERIALS INCLUDING ALL DIFFUSERS, GRILLES, AND REGISTERS. THE H.C. SHALL COORDINATE DUCTWORK INSTALLATIONS WITH OTHER TRADES. LIGHTING AND DUCTWORK DESIGNS INDICATED ON CONTRACT DRAWINGS WERE COORDINATED, HOWEVER CONFLICTS WITH DUCTWORK AND LIGHTS MAY ARISE DUE TO GRID INSTALLATION. H.C. SHALL BE RESPONSIBLE FOR ALL DUCTWORK MODIFICATIONS AND OFFSETS REQUIRED TO AVOID FIELD CONDITIONS. G. BALANCE DAMPERS SHALL BE LOCATED AT BRANCH CONNECTION TO THE MAIN. H. FLEXIBLE DUCTWORK IS LIMITED TO A MAXIMUM LENGTH OF 3 FEET, WITH NO DIPS, SAGS, OR TIGHT ELBOWS; AND ON SUPPLY DUCTWORK ONLY. FLEXIBLE DUCTWORK SHALL BE AN INSULATED, SEMI-RIGID AND LIGHT WEIGHT AIR DUCT, MANUFACTURED BY USING DEAD SOFT ALUMINUM STRIP WHICH IS SPIRALLY WOUND AND MECHANICALLY JOINED TOGETHER FORMING AN AIR TIGHT-LEAKPROOF TRIPLE LOCK SEAM. DUCT TO BE SELF-SUPPORTING AND CORROSIVE RESISTANT UL-181 CLASS I PRODUCT, WITH A POLYETHYLENE VAPOR BARRIER. FLEXIBLE DUCTWORK TO BE LIKE MASTERFIT UPC-018 (ACOUSTICAL) OR AN APPROVED EQUAL. I. LABEL ALL THERMOSTAT, SENSOR, ETC. AS TO WHAT THE DEVICE CONTROLS WITH AN ENLARGED, PLASTIC LABEL; MOUNTED UNDER OR ON THE DEVICE. J. PROVIDE NECK PLENUMS ON RETURN AND EXHAUST GRILLES AS REQUIRED. SEE DETAILS. K. PROVIDE TURNING VANES IN ALL SQUARE ELBOWS. SEE DETAILS. L. ALL EQUIPMENT INCLUDING BUT NOT LIMITED TO DUCTWORK, PIPING, UNIT HEATERS, ETC. SHALL BE HUNG FROM THE TOP CHORD OF THE STRUCTURAL STEEL. M. ALL EXTERIOR PENETRATIONS SHALL BE WEATHER AND WATER TIGHT. N. PROVIDE DUCT CLEANOUTS AS REQUIRED. O. REFRIGERANT PIPE SIZING AND CONFIGURATION BY UNIT MANUFACTURER. P. HVAC CONTRACTOR SHALL COORDINATE DUCT, DIFFUSERS, REGISTERS AND GRILLES WITH LIGHT FIXTURE LOCATIONS. Q. CONTRACTORS ARE TO REVIEW STRUCTURAL PLANS AND ACTUAL LAYOUT OF BEAMS, JOISTS, ETC. TO AVOID CONFLICT BETWEEN DUCT. ADJUST DUCT ROUTING TO ACCEPT STRUCTURAL CONDITIONS. R. ALL EXHAUST DISCHARGES AND GAS FLUES WHERE INDICATED SHALL BE LOCATED A MINIMUM OF 10'-0" AWAY FROM OUTSIDE AND COMBUSTION AIR INTAKES UNLESS LOCAL AND STATE CODES MANDATE ADDITIONAL DISTANCE. S. CONTRACTOR SHALL VERIFY ELECTRICAL CHARACTERISTICS OF ALL MECHANICAL EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO PLACING EQUIPMENT ON ORDER. T. WHERE WALL TYPE LOUVERS ARE INDICATED, MECHANICAL CONTRACTOR SHALL SEAL WATER-TIGHT ALL AROUND LOUVER WITH SILICON CAULKING. CONTRACTOR SHALL COORDINATE PAINTING REQUIREMENTS FOR LOUVERS WITH GENERAL CONTRACTOR PRIOR TO SUBMITTING BID. E.S.P. 0.70" EVAPORATOR FAN NOTES: RTU-1 1,600 CFM 1.0 1.2 1180 H.P. BHP RPM TRANE YSC048G3RHBDOD1A MANUFACTURER/ MODEL NO. HEATING 105.3 OUTPUT 47.9 39.0 79 65.9 MBH TOTAL SENS. COOLING EDB EWB 12.0 55.8 55.8 130.0 EER LWBLDB INPUT MBH APPROX. WEIGHT (lbs) 208/3Ø 26.0 UNIT POWER VOLTAGE MCA 760 SCHED9 ALL NOTESTAG 1. Constant volume, single zone unit. 2. Unit mounted disconnect and 120V outlet. 3. Cooling capacity @ 105°F outside air temperature. 4. Pre-fabricated manufacturer built acoustical roof curb with solid bottom 5. Enthalpy based economizer with relief damper. 6. Coil guard, modulating o.a. damper, crank case heater. 7. 7 day 24/7 programmable thermostat, 2-stage cooling. ROOF TOP UNIT SCHEDULE SYMMONSMX-1 8210CK POINT OF USE MIXING VALVE - -WITH SEPARATE STOPS SET 110°F DISCHARGE TEMP MANUFACTURERMARK NO. PLUMBING EQUIPMENT SCHEDULE ELECTRICAL V/PHHP NOTESMODELDESCRIPTION AMTROLET-1 EXPANSION TANK - - ST-25 PROVIDE WITH SHUT OFF VALVE PIPING INSULATION SCHEDULE (INDOOR) NOTES: FLUID TEMP. RANGE (°F) SYSTEM 1. RUNOUTS NOT EXCEEDING 12 FEET IN LENGTH AND 2" PIPE TO INDIVIDUAL HVAC TERMINAL UNITS. 2. RUNOUTS THAT ARE NOT LARGER THAN 1" AND NON-CIRCULATING TO INDIVIDUAL PLUMBING UNITS. 3. INCLUDES ROOF DRAIN BODY AND VERTICAL RUN UP TO THE ROOF DRAIN BODY. 4. PROVIDE PVC JACKET ON EXTERIOR REFRIGERANT PIPING. 5. INSTALL 3'X3'X1" ARMAFLEX GLUED TO BOTTOM OF RD AND OFD BODY'S. (EXISTING & NEW REFRIGERANT (SEE NOTE 4) 40 & BELOW DOMESTIC HOT WATER & RETURN 100-300 DOMESTIC COLD WATER 40-75 CONDENSATE DRAIN 40-55 INSULATION TYPE MF OR FE MF OR FE MF OR FE MF OR FE JACKET TYPE FP FP FP FP VAPOR BARRIER REQ'D RUNOUTS (NOTE 1& 2 1" & LESS 1.25" TO 2" 2.5" TO 4" 5" & ABOVE 1.0 1.0 1.5 1.5 1.0 0.5 0.5 0.5 - 0.5 0.5 - ---- 0.5 0.5 0.5 ----INSULATIONTHICKNESS (IN)ABBREVIATIONS INSULATION TYPES FE FLEXIBLE ELASTOMERIC CG CELLULAR GLASS MF MINERAL FIBER (FIBERGLASS) PO POLYOLEFIN CS CALCIUM SILICATE CCF CLOSED-CELL FOAM FP FOIL & KRAFT PAPER PVC CELLULAR GLASS AL ALUMINUM SS STAINLESS STEEL NOTES ELECTRICAL MANUFACTURER/MODEL NOTESTAG ELECTRIC WATER HEATER SCHEDULE 1. PROVIDE WITH T&P VALVE, PIPE TO NEAREST DRAIN. 2. PROVIDE 2" TALL DRIP PAN. 3. PROVIDE HEAT TRAP IF NOT BUILT INTO TANK CONNECTIONS. 4. PROVIDE 10 YEAR RESIDENTIAL WARRANTY. POWER RECOVERY GPH 90° RISE WH-1 STATE PCE30-20LSA DESCRIPTION ELECTRIC WATER HEATER WATTS 208/1Ø 2500 11 1ST HOUR 30 GALLON CAPACITY 30 ALL NOTES MANUFACTURER/ MODEL NO. VOLTAGE NOTES: EF-1 TAG CFM E.S.P.RPM SONES WATTS SPEED CONTROLLED BY: BHP EXHAUST FAN SCHEDULE FAN DATA TIP ELECTRICAL DATA LOCATION Unit mounted disconnect, backdraft damper, variable speed controller, deluxe metal, and 6" wall cap. All ductwork to be hard sheetmetal (no flex). Connect ductwork to fan with flexible connection. 1. 2. 3. ALL 120V/1Ø 80 - PANASONIC FV-0511VKS2 RESTROOM -LIGHT SWITCH PLUMBING FIXTURE SCHEDULE MARK P-2 FIXTURE MANUFACTURER MODEL No. TYPE MATERIAL STYLE COLOR FAUCET / VALVE MANUFACTURER MODEL SPOUT HANDLES CENTERS SUPPLY STOPS DRAIN TYPE/MFR/MODEL TRAP SIZE DOMESTIC CW DOMESTIC HW SANITARY WASTE SANITARY VENT REMARKS NOTES NOTE: LAVATORY V.C. KOHLER KOHLER WATER CLOSET ADA K-2005 21x14 WALL HUNG WHITE 110-GNZ- AE35- 317A8 BRASS CRAFT CS400AC 1-1/2 WITH/ MX-1 VALVE, WITH LAMINAR FLOW SPRAY HEAD 1,3 2" 3" --- --- --- ---ELONGATED K3578 TANK --- ------1/2" 2" 1-1/2" KOHLER K-4670-C-O ELONGATED SEAT 1. INSTALL ADA PLUMBING FIXTURES PER ANSI 117.1 GUIDELINES. 2. PROVIDE WITH PROSET SYSTEMS "TRAP GUARD". COORDINATE WITH PROSET SYSTEMS FOR PART NUMBERS AND INSTALLATION. TEL. #1-800-262-5355. 3. TRAPS, SUPPLIES, ETC TO BE CHROME. 4. PROVIDE ADA OFFSET GRID STRAINER AND PADDED SUPPLIES AND DRAIN. 5. VERIFY LOCATION OF FLOOR DRAIN AND SIZE REQUIRED. 6. SANITARY WASTE LINE SIZE AS INDICATED ON PLANS. 7. PROVIDE 0.5 AERATOR ON FAUCET. 8. PROVIDE WITH 16 GAUGE STAINLESS STEEL SHROUD, BUILT TO ENCLOSE REAR OPENING OF P-1 WATER CLOSET, INSTALL 2x4 BACKING, FASTEN TO WALL WITH 6-#8 S.S. VANDAL PROOF SCREWS, COVER TO ENCOMPASS TOP AND SIDE OF W.C. 9. PIPE OFD INTO RD RISER PER INDIANA PLUMBING CODE. P-1 1,3V.C.WHITE --- --- 3/8" 3/8" CAST GRID ZURN Z8743------ --- CHICAGO -- - - THE PLANS, IDEAS & DESIGNS REPRESENTED HERE ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF APRIL MCCLURG DESIGN CO. ALL RIGHTS RESERVED, EXCEPT WHEN WRITTEN CONSENT IS GIVEN. CONTRACTORS ARE TO VERIFY AND ARE RESPONSIBLE FOR ALL JOB SITE DIMENSIONS.UNIT 130- DIVIDEWEST CARMEL 'B' SHOPPES9873 NORTH MICHIGAN ROADCARMEL, INDIANA 46032Mechanical, Electrical, & Energy Engineering 2707 Rand Road Indianapolis, In 46241 voice: 317-464-9090 fax: 317-464-9393 www.daengineering.com DESIGN-AIRE ENGINEERING, INCSOUTH BUILDINGISSUE: SUBMITTAL SET DATE: 11/18/2021 PM-1 PLUMBING AND HVAC SCHEDULES 01/03/22