HomeMy WebLinkAboutPM2EXTERIOR-WRAPPED INSULATION- THERMOSTAT SENSOR CONICAL TAP WITH DAMPER SHOE TAP REGISTER TAG DIFFUSER, GRILLE, THERMOSTAT SUPPLY DIFFUSER, CEILING RETURN, EXHAUST GRILLE, CEILING TURNING VANES LINED DUCT DIMENSIONS SEE SPECIFICATIONS ) (INCLUDES LINING) AIR EXTRACTOR PIPE DOWN PIPE UP MANUAL DAMPER FLEXIBLE CONNECTION VERTICAL FIRE DAMPERDUCT DIMENSIONS (WITH HVAC - TYPICAL SYMBOLS ROOFTOP UNIT DETAIL ROOFTOP UNIT PRE-MANUFACTURER CONDENSATE DRAIN ROOF NOTE: ALLOW CLEARANCE FOR OPENING ALL ACCESS PANELS (NOTE: DUCT SHOWN FOR CLARITY) RETURN AIR DUCT TO BE INLINED TO ELBOW SUPPLY AIR DUCT TURNING VANES; TYPICAL FLEXIBLE DUCT CONNECTION; TYPICAL OUTSIDE AIR ECONOMIZER ACUSTICAL CURB 3-WAY VALVE (MIXING VALVE) RPZ UNION BACK FLOW PREVENTER HOSE BIBB FLOOR DRAIN CHECK VALVE BALL VALVE SHUT OFF VALVE PIPE DOWN FF F GG G GAS PIPING (BLACK STEEL) PIPE UP FIRE (SPRINKLER) PIPING DOMESTIC HWR PIPING (COPPER) DOMESTIC HW PIPING (COPPER) DOMESTIC CW PIPING (COPPER) STORM PIPING (SCHD 40 PVC) VENT PIPING (SCHD 40 PVC) WASTE PIPING (SCHD 40 PVC) PIPING & SYMBOLS LEGEND NOT TO SCALE GAS DIRT LEG DETAIL GAS VALVE MANUAL SHUTOFF VALVE 3" MINIMUM LEAVE CLEARANCE FOR PIPE CAP TO BE REMOVED APPLIANCE NOT TO SCALE PUT SCREEN FITTING ON PIPE END LIKE FISHER #Y602-9 NOTE: TAG VALVE AND REGULATOR PER SPECIFICATIONS; STATE ON REGULATOR TAG, EQUIPMENT SERVICED AND PRESSURES. VENT AS SPECIFIED (OR PER MANUFACTURER RECOMMENDATION) TO OUTSIDE PAINT PIPE COLOR AS SELECTED BY ENGINEER REGULATOR SEE SCHEDULE OR PLAN NOTE UNION PLUG VALVE DIRT LEG GAS SUPPLY GAS APPLIANCE REGULATOR DETAIL PC TO PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0-RING CONSTRUCTION, HAVING PDI #WH- 201, ASSE #1010 AND ANSI #A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND/OR PER THE TABLES SHOWN ABOVE. PROVIDE ACCESS PANEL FOR SERVICING OR REPLACEMENT, WHERE REQUIRED. F E 154-330 114-1541-1/2" 2" SHOWER/BATHTUB JANITOR'S SINK 2 3 2 3 PROVIDE ANOTHER HA IN MIDDLE, EACH IF BRANCH IS GREATER THAN 20' LONG, LONG, PROVIDE ONE HA AT END OF LINE IF HORIZONTAL BRANCH IS LESS THAN 20' SIZED FOR HALF THE FIXTURE UNITS"A"INSTRUCTIONS SINGLE FIXTURE C D A B PDI SIZE 33-60 12-32 61-1131-1/4" 1" 3/4" 1/2" 1-11 FIXTURE UNIT LOAD PIPE SIZE PDI SIZE INSTALL PER PDI MANUFACTURER'S STANDARDS AND MULTIPLE FIXTURES FIXTURE UNIT TABULATION VALVE WATER CLOSET LAVATORY/SINK TANK WATER CLOSET URINAL FIXTURE 1.5 5 1.5 -- 5 10 -- -- HOTCOLD HA- HA- HA- HA- HA- HA- HAMMER ARRESTERS NOT TO SCALE SIDE VIEW WALL SIDE FRONT TOP VIEW 3/4" WEATHERPROOF PLYWOOD UNDER HEATER DRAIN PAN WATER HEATER LOCATION 24"24"BOLT TO WALL ABOVE FINISHED CEILING 22"(WELDED CORNER, ENDS, ETC. TYPICAL) CW BALLVALVE; TYPICAL EXPANSION TANK DIELECTRIC UNION; TYPICAL WATER HEATER TEMP. & RELIEF VALVE WATER HEATER PIPE DISCHARGE TO OVERFLOW PAN PROVIDE 2" PLASTIC OVERFLOW PAN UNDER HEATER CHECK VALVE; TYPICAL UNION; TYPICAL WATER HEATER SHELF DETAIL 1-1/2"x1-1/2"x3/16" ANGLE; TYPICAL 4"W EX-4"W P-2 P-11-1/2"V2"V 2"V2"WWASTE AND VENT ISOMETRIC NOT TO SCALE CONNECT TO EXISTING BUILDING VENT MAIN NOT TO SCALE NOT TO SCALE NOT TO SCALE B8-200 THE PLANS, IDEAS & DESIGNS REPRESENTED HERE ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF APRIL MCCLURG DESIGN CO. ALL RIGHTS RESERVED, EXCEPT WHEN WRITTEN CONSENT IS GIVEN. CONTRACTORS ARE TO VERIFY AND ARE RESPONSIBLE FOR ALL JOB SITE DIMENSIONS.UNIT 130- DIVIDEWEST CARMEL 'B' SHOPPES9873 NORTH MICHIGAN ROADCARMEL, INDIANA 46032Mechanical, Electrical, & Energy Engineering 2707 Rand Road Indianapolis, In 46241 voice: 317-464-9090 fax: 317-464-9393 www.daengineering.com DESIGN-AIRE ENGINEERING, INCSOUTH BUILDINGISSUE: SUBMITTAL SET DATE: 11/18/2021 PM-2 PLUMBING AND HVAC DETAILS 01/03/22