HomeMy WebLinkAboutA2RISER
NEW TENANT SPACE
'A'
100
STORAGE
101
ADA
RR
102
NEW TENANT SPACE
'B'
200
NEW ADA
RR
201DISPLAY
THE PLANS, IDEAS & DESIGNS REPRESENTED
HERE ARE THE EXCLUSIVE INTELLECTUAL
PROPERTY OF APRIL MCCLURG DESIGN CO.
ALL RIGHTS RESERVED, EXCEPT WHEN WRITTEN
CONSENT IS GIVEN.
CONTRACTORS ARE TO VERIFY AND ARE
RESPONSIBLE FOR ALL JOB SITE DIMENSIONS.
ISSUE: SUBMITTAL SET
DATE: 11/18/2021UNIT 130- DIVIDEWEST CARMEL 'B' SHOPPES9873 NORTH MICHIGAN ROADGenesis Design, Inc.CARMEL, INDIANA 46032SOUTH BUILDINGDEMO PLAN
SCALE: 1/8"=1'-0"
CONSTRUCTION & FINISH PLAN
SCALE: 1/8"=1'-0"
WALL TYPES
EXISTING WALL TO REMAIN NEW WALL
WALL: 3-58" METAL STUDS @ 16"
O.C. WITH (1) LAYER OF 58"
GYPSUM BOARD ON EACH
SIDE. WALL TO EXTEND TO
10'-0". EXACT WALL
CONSTRUCTION & THICKNESS
IS TO BE DETERMINED BY
STRUCTURAL REQUIREMENTS.
PLUMBING FIXTURES SCHEDULE
TYPEQTY FIXTUREDESCRIPTIONMANUF.STYLEREMARKSFINISHWC1 1 ADA COMPLIANTWATER-CLOSET AMERICANSTANDARD CADET, 2467.100 PORCELAIN WHITE SPECS LISTED ARE TO SERVE ASGUIDELINE. APPROVED "LIKE"PRODUCTS CAN BE SUBMITTED.
LAV1 1 ADA COMPLIANTWALL-MOUNTEDLAVATORY
AMERICANSTANDARD COMRADE, 0124.024 PORCELAIN WHITE
FA1 2 ADA-COMPLIANTCOMMERCIALBATHROOM FAUCET
DELTA 3549FL-WFLGHDF CHROME
*THE ABOVE LISTED FIXTURES ARE SUGGESTIONS ONLY. CONTRACTOR CAN SELECT ALTERNATE FIXTURES.**CONTRACTOR IS TO PROVIDE PLUMBING FIXTURE CUT-SHEETS FOR OWNER APPROVAL.
NEW ADA RR 201- ENLARGED PLAN
SCALE: 1/2"= 1'-0"
GENERAL RESTROOM NOTES
1. ALL NEW FIXTURES ARE TO BE ADA COMPLIANT & COMFORT HEIGHT, WHERE APPLICABLE.
2. WATER CLOSET FIXTURE TYPES SHOWN ON DRAWINGS ARE DIAGRAMTIC ONLY.
3. LAVATORIES AND WATER CLOSETS ARE TO BE LEVER TYPE CONTROL, MOUNTED ON THE ACCESSIBLE SIDE OF TOILET.
4. PROVIDE SOLID BLOCKING IN WALL, AS REQUIRED, TO SUPPORT LAVATORIES, TOILET ACCESSORIES, ETC.
5. MOUNT ALL ACCESSORIES AT HEIGHTS & LOCATIONS INDICATED ON MANUFACTURER'S INSTALLATION INSTRUCTIONS.
PROVIDE APPLICABLE ACCESSIBILITY COMPLIANCE. DIAGRAM SHOWN ON THIS SHEET.
6. FINAL LOCATION OF ALL ACCESSORIES IS TO BE DISCUSSED IN THE FIELD WITH THE CLIENT PRIOR TO INSTALLATION.
AMERICAN W/ DISABILITIES ACT CRITERIA
SCALE: NOT TO SCALE ELEVATIONS
PLUMBING NOTES
1 PROVIDE & INSTALL NEW, STANDARD STAINLESS MIRROR ABOVE RESTROOM SINK.
PROVIDE & INSTALL ADA RESTROOM SIGN ON WALL OUTSIDE RESTROOM, NEXT TO RESTROOM DOOR, AS REQUIRED.2
SPECS LISTED ARE TO SERVE ASGUIDELINE. APPROVED "LIKE"PRODUCTS CAN BE SUBMITTED.
SPECS LISTED ARE TO SERVE ASGUIDELINE. APPROVED "LIKE"PRODUCTS CAN BE SUBMITTED.
A2
DEMO PLAN
ARCHITECTURAL
PLAN & DETAILS
WALL: 6" METAL STUDS @ 16"
O.C. WITH R-19 BATT INSULATION
& (1) LAYER OF 58" GYPSUM
BOARD ON EACH SIDE. EXACT
WALL CONSTRUCTION &
THICKNESS IS TO BE DETERMINED
BY OWNERS DEMISING
REQUIREMENTS. WALL IS TO
EXTEND TO DECK/STRUCTURE
ABOVE.
NEW STOREFRONT DOUBLE-DOOR ENTRY- ELEVATION
SCALE: 1/2"= 1'-0"
1
A2
1
A2
CONSTRUCTION PLAN NOTES
*ALL DIMENSIONS SHOWN ARE APPROXIMATE AND WILL NEED TO BE FIELD VERIFIED AS REQUIRED FOR NEW CONSTRUCTION AND/OR CASEWORK. FINAL DIMENSIONS WILL BE
DETERMINED BY ACTUAL WALL CONSTRUCTION AND FINISHED THICKNESS.
ALIGN FINISHED SURFACES. NEW WALLS THAT ALIGN WITH EXISTING WALLS TO BE ALIGNED TO THEIR FINISHED FACE.
REPAIR DRYWALL, AS NEEDED, WHERE DEMO OCCURRED.
PROVIDE A NEW, 54" METAL EXTERIOR DOOR & HARDWARE (TO MATCH EXISTING) TO REPLACE THE EXISTING 36" DOOR, WHERE INDICATED. EXTERIOR SIDE OF DOOR IS TO BE PAINTED TO
MATCH OTHER BUILDING EXTERIOR DOORS. ENSURE THAT NEW DOOR PLACEMENT IS CENTERED ON EXTERIOR CONCRETE WALKWAY. REPAIR EXTERIOR BRICK, AS NEEDED.
CONSTRUCT NEW DEMISING WALL, TO HAVE DRYWALL APPLIED TO BOTH SIDES, SEE WALL TYPE 2. DRYWALL IS TO REMAIN UNFINISHED & IS NOT TO BE PREPPED OR PAINTED.
EXISTING CONCRETE FLOOR IS TO BE LEFT IN SMOOTH CONDITION.
CONSTRUCT NEW, ADA COMPLIANT RESTROOM. SEE ENLARGED PLAN, PLUMBING SCHEDULE & ADA REQUIREMENTS ON THIS SHEET. NEW WALLS ARE TO REMAIN UNFINISHED DRYWALL.
NEW VCT IS TO BE APPLIED TO RESTROOM FLOOR. VCT IS TO BE: TARKETT 12"X12" STANDARD VCT, 1324 COOL GRAY (OR SIMILAR).
NEW RESTROOM IS TO RECEIVE A NEW 3'-0" X 7'-0" PREFINISHED SOLID CORE WOOD DOOR & METAL DOOR FRAME. DOOR & FRAME ARE TO MATCH BUILDING STANDARD INTERIOR
DOORS.
EXISTING CEILING GRID & TILE ARE TO REMAIN IN THIS SPACE. REPAIR DAMAGED TILES, AS NEEDED.
PROVIDE A NEW, DOUBLE-DOOR ENTRY FOR THIS SPACE. SEE ELEVATION 1/A2 FOR DETAILS.
NO WORK IN THIS AREA.
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C1
C2
C2
C2 C3
C4 C4
C5
C5
C6
C7
C8
C9
C10
C10
DEMO PLAN NOTES
*ALL DIMENSIONS SHOWN ARE APPROXIMATE AND WILL NEED TO BE FIELD VERIFIED AS REQUIRED FOR NEW CONSTRUCTION AND/OR CASEWORK. FINAL DIMENSIONS WILL BE
DETERMINED BY ACTUAL WALL CONSTRUCTION AND FINISHED THICKNESS.
DEMO EXISTING CARPET, THROUGHOUT.
EXISTING VCT FLOORING IS TO REMAIN.
DEMO EXISTING DOOR, FRAME & EXTERIOR WALL, AS NEEDED, FOR NEW 54" DOOR.
DEMO CEILING GRID & TILE ,ON THIS SIDE OF THE NEW DEMISING WALL, ONLY. EXISTING LIGHTING IS TO REMAIN. NEW TENANT WILL HAVE OPEN CEILING CONCEPT.
DEMO EXISTING WALLS & RAISED FLOOR AREA, AS INDICATED.
DEMO LIGHT FIXTURE & SALVAGE FOR RELOCATION, ONLY AS NEEDED WHERE NEW CONSTRUCTION OCCURS.
DEMO AREA OF STOREFRONT, ONLY AS REQUIRED FOR NEW DOUBLE-DOOR ENTRY. SEE ELEVATION 1/A2 FOR DETAILS.
NO WORK IN THIS AREA.
D1
D2
D3
D4
D5
D6
D7
D8
C8D1
D2
D2
D3
D4
D5
D6
D7
D8
D1
1
2
01/03/22