HomeMy WebLinkAboutE1SURFACE/RECESSED 2 x 4 LED LIGHT FIXTURE SURFACE/RECESSED 1 x 4 LED LIGHT FIXTURE SWITCHES LIGHT FIXTURE CONNECTED TO EMERGENCY POWER EXIT LIGHT FIXTURE WALL MOUNTED EXIT LIGHT FIXTURE CEILING MOUNTED EMERGENCY BATTERY UNIT SWITCH, SINGLE POLE SWITCH, THREE-WAY PHOTOCELL BATTERY OPERATED EMERGENCY LIGHT - WALL MOUNTED SWITCH, FOUR-WAY RECEPTACLE, QUADPLEX RECEPTACLE CEILING MOUNTED, DUPLEX RECEPTACLE, DUPLEX, GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE, DUPLEX, EMERGENCY RED TWIST LOCK RECEPTACLE, DUPLEX RECEPTACLE, SINGLE SWITCH, MANUAL TIMER SWITCH, PILOT LIGHT SWITCH, KEYED SWITCH, DOOR SECURITY SWITCH, CONTROLLING FIXTURES MARKED WITH a SWITCH, DIMMER LIGHTS WIRING TURNED UP WIRING EMERGENCY FLUSH FLOOR BOX, THREE GANG WIRING CONCEALED UNDER OR IN FLOOR WIRING CONCEALED IN CEILING OR WALL RECEPTACLE SPECIAL, NEMA CONFIGURATION FLUSH FLOOR OUTLET DUPLEX RECEPTACLE POWER FIRE ALARM, FLOW SWITCH DISCONNECT SWITCH ELECTRICAL CONNECTION FLUSH OR SURFACE MOUNTED BRANCH MOTOR CONTROLLER WITH AUX CONTACTS HOA, PB, TT SWITCH FOR MOTORS 1/2HP OR SMALLER MAIN DISTRIBUTION OR POWER PANELBOARDS JUNCTION BOX 4 11/16 x 4 11/16 x 2 1/8" CABLE TRAY WIREMOLD APENDED NOTE DENOTES TYPE HEAT TRACE CABLE FIRE ALARM, TAMPER SWITCH PANIC BUTTON PUSH BUTTON "UP-DOWN-DN" FIRE ALARM ANNUNICATOR PANEL FIRE ALARM CONTROL PANEL WIRING TURNED DOWN PUSH BUTTON CONTROL STATION COMBINATION PHOTOELECTRIC & FIRE ALARM, IONIZATION DUCT DETECTOR FIRE PILOT AND CONTROL TRANSFORMER. CLOCK OUTLET SECURITY MOTION DETECTOR SECURITY ALARM POINT DOOR SWITCH SECURITY DOOR LOCK RELEASE - ELECTRIC STRIKE SECURITY ALARM BELL TRANSFORMER, 120V TO LOW VOLTAGE CLOCK OUTLET WITH CONTROL STATION TELEVISION OUTLET (RG6) DOORBELL PUSH BUTTON DOOR BELL CHIME POLE MOUNTED LIGHT FIXTURE - SINGLE HEAD SURFACE / RECESSED LED FIXTURE FLOOD LIGHT GROUND MOUNTED BOLLARD LIGHT FIXTURE WALL MOUNTED LED FIXTURE WIRE UNLESS NOTED OTHERWISE THERMAL DETECTOR 135° FIXED PHOTO DETECTOR PHOTO ELECTRIC HORN STROBE FIRE ALARM, SPEAKER STROBE UNIT 30CD IONIZATION SMOKE PULL STATION A= GROUND; B= NEUTRAL; C= HOT HOMERUN MOTION DETECTOR WALL MOUNTED LED FIXTURE SURFACE MOUNTED OR RECESSED LED FIXTURE FIRE ALARM, SPEAKER STROBE COMMUNICATION / SECURITY CARD KEY ACCESS CONTROL RECEPTACLE, DUPLEX WEATHERPROOF ('WHILE-IN-USE' TYPE) TELEVISION OUTLET (RG6 AND 2-CAT6) RECEPTACLE ON EMERGENCY CIRCUIT, RECEPTACLE AND PLATE SHALL BE RED CEILING MOUNTED FIRE ALARM HORN / STROBEPANELBOARDS 120/280V SECURITY GLASS BREAK DETECTOR OS 2 OS OS U SINGLE CIRCUIT PIR WALL SENSOR 'SCHNEIDER ELECTRIC' #SLSPWS1277UX(COLOR). DUAL CIRCUIT PIR WALL SENSOR 'SCHNEIDER ELECTRIC' #SLSPWD1277UX(COLOR). LOW VOLTAGE ULTRASONIC CEILING SENSOR 'SCHNEIDER ELECTRIC' #SLSCUS2000 (SENSOR); 'SCHNEIDER ELECTRIC' #SLSPP1277 (POWER PACK) OS OS D/T LOW VOLTAGE CEILING MOUNT PIR OCCUPANCY SENSOR 'SCHNEIDER ELECTRIC' #SLSCI2000 (SENSOR); 'SCHNEIDER ELECTRIC' #SLSPP1277 (POWER PACK). LOW VOLTAGE CEILING MOUNT DUAL-TECHNOLOGY OCCUPANCY SENSOR 'SCHNEIDER ELECTRIC' #SLSCDT2000 (SENSOR); 'SCHNEIDER ELECTRIC' #SLSPP1277 (POWER PACK). USB RECEPTACLE GROUND FUSE CIRCUIT BREAKER CIRCUIT POWER TRANSFORMER RATING AS NOTED NON-FUSED DISCONNECT SWITCH 480V PRIMARY, 120V SECONDARY FUSED DISCONNECT SWITCH ELECTRICAL TRANSFORMER GENERAL NOTES 2. SUBMIT SUBMITTALS ON ALL EQUIPMENT, DEVICES AND MATERIALS. 3. COORIDNATE WITH OTHER DISCIPLINES AND OWNER TO VERIFY FINAL LOCATIONS OF DEVICES AND CONNECTIONS. 4. SLOPED PIPING HAS RIGHT OF WAY OVER CONDUIT. 5. INSTALL PENETRATION FIRESTOPPING AS INDICATED AND REQUIRED. 6. HEIGHTS OF SUSPENDED EQUIPMENT SHALL BE TO THE BOTTOM OF THE UNIT. 7. HEIGHTS OF WALL MOUNTED EQUIPMENT SHALL BE TO THE CENTER OF THE UNIT. 8. IF MOUNTING HEIGHT IS NOT INDICATED, INSTALL AS HIGH AS POSSIBLE. 9. INSTALL SLEEVES AS NECESSARY: a. SLEEVES FOR RACEWAYS AND CABLES SHALL BE SCHEDULE 40 GALVANZIED STEEL PIPE SLEEVES, ASTM A53/ A53M TYPE E, GRADE B WITH PLAIN ENDS. b. FOR RECTANGULAR OPENSINGS USE GALVANZIED SHEET STEEL WITH A THICKNESS OF 0.052 INCHES FOR OPENINGS SMALLER THAN 50 INCHES IN PERIMETER AND 0.138 INCHES FOR THOSE LARGER. c. SLEEVES SHALL BE FLUSH WITH WALLS. d. EXTEND FLOOR SLEEVES 2” ABOVE FINISHED FLOOR LEVEL. e. IF NECESSARY GROUT SPACE OUTSIDE OF SLEEVE IN CONCRETE AND MASONRY WALLS AND FLOOR. f. IN NON RATED FIRE WALLS AND FLOORS SEAL ANNULAR SPACE WITH JOINT SEALANT. g. ALWAYS MAINTAIN FIRE RATING OF ASSEMBLY. 9. IF REQUIRED FOR HYDROSTATIC PRESSURE REASONS, INSTALL EPDM SEALING ELEMENTS WITH TWO PLASTIC PRESSURE PLATES AND STAINLESS STEEL CONNECTING BOLTS AND NUTS. 10. GROUT SHALL BE NONMETALIC SHRINK-RESISTANT TYPE THAT IS NONSTAINING AND NON CORROSIVE. 11. EXTEND FLOOR SLEEVES 2” ABOVE FINISHED FLOOR. 12. MAINTAIN FIRE RATING OF FIRE-RATED ASSEMBLIES. 13. SEAL PENETRATION OF INDIVIDUAL RACEWAYS AND CABLES WITH FLEXIBLE BOOT-TYPE FLASHING. APPLICABLE CODES AND STANDARDS 29 CFR 1910.144SAFETY COLOR CODE FOR MARKING PHYSICAL HAZARDS. 29 CFR 1910.145SPECIFICATIONS FOR ACCIDENT PREVENTION SIGNS AND TAGS. ANSI A13.1 SCHEME FOR THE IDENTIFICATION OF PIPING SYSTEMS ANSI C80.1 ELECTRIC RIGID STEEL CONDUIT ANSI C80.3 ELECTRICAL METALLIC TUBING - STEEL (EMT-S) ANSI C80.5 ELECTRICAL RIGID METAL CONDUIT - ALUMINUM (ERMC-A) ANSI C80.6 ELECTRICAL INTERMEDIATE METAL CONDUIT ANSI Z535.1 PRODUCT SAFETY PACKAGE ANSI Z535.5 SAFETY TAGS AND BARRICADE TAPES (FOR TEMPORARY HAZARDS) ANSI Z535.4 PRODUCT SAFETY SIGNS AND LABELS ASTM A 36/ A 36M STANDARD SPECIFICATION FOR CARBON STRUCTURAL STEEL ASTM A 53/ A53M STANDARD SPECIFICATION FOR PIPE, STEEL, BLACK AND HOT-DIPPED, ZINC-COATED, WELDED AND SEAMLESS ASTM A 641/A 641M STANDARD SPECIFICATION FOR ZINC–COATED (GALVANIZED) CARBON STEEL WIRE ASTM A780 STANDARD PRACTICE FOR REPAIR OF DAMAGED AND UNCOATED AREAS OF HOT-DIP GALVANIZED COATINGS ASTM B3 STANDARD SPECIFICATION FOR SOFT OR ANNEALED COPPER WIRE ASTM B8 CONCENTRIC-LAY-STRANDED COPPER CONDUCTORS, HARD, MEDIUM-HARD, OR SOFT ASTM B33 TIN-COATED SOFT OR ANNEALED COPPER WIRE FOR ELECTRICAL PURPOSES ASTM C 1107 GROUT AWS D1.1/ D1.1M STRUCTURAL WELDING CODE--STEEL ASTM D 638 STANDARD TEST METHOD FOR TENSILE PROPERTIES OF PLASTICS ASTM D 882 STANDARD TEST METHOD FOR TENSILE PROPERTIES OF THIN PLASTIC SHEETING IEEE C2 2017 NATIONAL ELECTRICAL SAFETY CODE(R) (NESC(R)) IEEE 344 SEISMIC QUALIFICATION OF SAFETY RELATED EQUIPMENT FOR CLASS 1E EQUIPMENT MFMA-4 METAL FRAMING STANDARDS PUBLICATION NECA 1 STANDARD FOR GOOD WORKMANSHIP IN ELECTRICAL CONSTRUCTION PDF NECA 101 STANDARD FOR INSTALLING STEEL CONDUITS (RIGID, IMC, EMT) NECA 407 STANDARD FOR INSTALLING AND MAINTAINING PANELBOARDS NEMA AB 1 MOLDED-CASE CIRCUIT BREAKERS, MOLDED CASE SWITCHES, AND CIRCUIT-BREAKER ENCLOSURES NEMA ICS 2 INDUSTRIAL CONTROL AND SYSTEMS CONTROLLERS, CONTACTORS AND OVERLOAD RELAYS RATED 600 VOLTS NEMA ICS 5 CONTROL CIRCUIT AND PILOT DEVICES NEMA ICS 6 ENCLOSURES NEMA KS 1 HEAVY DUTY ENCLOSED AND DEAD-FRONT SWITCHES (600 VOLTS MAXIMUM) NEMA FB1 CONDUIT FITTINGS NEMA LE 4 RECESSED LUMINAIRES, CEILING COMPATIBILITY NEMA OS 1 SHEET-STEEL OUTLET BOXES, DEVICE BOXES, COVERS AND BOX SUPPORTS NEMA PB 1 PANELBOARDS NEMA RN1 POLYVINYL CHLORIDE (PVC) EXTERNALLY COATED GALVANIZED RIGID STEEL CONDUIT AND INTERMEDIATE METAL CONDUIT NEMA TC2 ELECTRICAL POLYVINYL CHLORIDE (PVC) CONDUIT NEMA TC3 POLYVINYL CHLORIDE (PVC) FITTINGS FOR USE WITH RIGID PVC CONDUIT AND TUBING NEMA TC13 ELECTRICAL NONMETALLIC TUBING (ENT) NEMA WC 70 POWER CABLES RATED 2000 VOLTS OR LESS FOR THE DISTRIBUTION OF ELECTRICAL ENERGY NEMA WD 1, GENERAL COLOR REQUIREMENTS FOR WIRING DEVICES NEMA WD 6 WIRING DEVICES--DIMENSIONAL SPECIFICATIONS NETA MTS STANDARD FOR MAINTENANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS NFPA 70 NATIONAL ELECTRICAL CODE NFPA 70B RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE NEMA 250 ENCLOSURES FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM) SSPC-PA1 FIELD AND MAINTENANCE COATING OF METALS TIA/ ATIS J-STD-607-A COMMERCIAL BUILDING GROUNDING (EARTHING) AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS UL 50 ENCLOSURES FOR ELECTRICAL EQUIPMENT, NON-ENVIRONMENTAL CONSIDERATIONS UL 94 STANDARD FOR TESTS FOR FLAMMABILITY OF PLASTIC MATERIALS FOR PARTS IN DEVICES AND APPLIANCES UL 98 ENCLOSED AND DEAD-FRONT SWITCHES UL 467 GROUNDING AND BONDING EQUIPMENT UL486A WIRE CONNECTORS UL486B UL STANDARD FOR SAFETY WIRE CONNECTORS FOR USE WITH ALUMINUM CONDUCTORS UL 489 MOLDED-CASE CIRCUIT BREAKERS, MOLDED-CASE SWITCHES, AND CIRCUIT-BREAKER ENCLOSURES UL 514B CONDUIT, TUBING, AND CABLE FITTINGS UL 514C STANDARD FOR NONMETALLIC OUTLET BOXES, FLUSH-DEVICE BOXES, AND COVERS UL 886 UL STANDARD FOR SAFETY OUTLET BOXES AND FITTINGS FOR USE IN HAZARDOUS (CLASSIFIED) LOCATIONS UL 924 EMERGENCY LIGHTING AND EXIT SIGN REGULATIONS UL 943 GROUND-FAULT CIRCUIT-INTERRUPTERS UL 969 STANDARD FOR MARKING AND LABELING SYSTEMS UL 1436. STANDARD FOR OUTLET CIRCUIT TESTERS AND SIMILAR INDICATING DEVICES UL 1660 LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT UL 1863 STANDARD FOR COMMUNICATIONS-CIRCUIT ACCESSORIES CARBON MONOXIDE DETECTOR F F ELECTRICAL MOTOR CONNECTION - VERIFY HP, AND PHASE ELECTRICAL CONNECTION 1. INSTALLATION SHALL COMPLY WITH 2009 INDIANA ELECTRIC CODE. ALL ITEMS/ EQUIPMENT INSTALLED EITHER IN PART OR ASSEMBLY SHALL BE UL/ NRTL LISTED PER CODE. THE PLANS, IDEAS & DESIGNS REPRESENTED HERE ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF APRIL MCCLURG DESIGN CO. ALL RIGHTS RESERVED, EXCEPT WHEN WRITTEN CONSENT IS GIVEN. CONTRACTORS ARE TO VERIFY AND ARE RESPONSIBLE FOR ALL JOB SITE DIMENSIONS.UNIT 130- DIVIDEWEST CARMEL 'B' SHOPPES9873 NORTH MICHIGAN ROADCARMEL, INDIANA 46032Mechanical, Electrical, & Energy Engineering 2707 Rand Road Indianapolis, In 46241 voice: 317-464-9090 fax: 317-464-9393 www.daengineering.com DESIGN-AIRE ENGINEERING, INCSOUTH BUILDINGISSUE: SUBMITTAL SET DATE: 11/18/2021 E-1 ELECTRICAL ABBREVIATIONS & SYMBOLS 01/03/22