HomeMy WebLinkAboutE3GASMETERELECTRICALPANEL(200AMP)NOT VERIFIEDMETER BANK NOT VERIFIEDTRASHSCREEN WALLN RTU-1 FLOOR PLAN - ELECTRICAL SCALE: 1/4"= 1'-0" 3 GFI WP (BY MFR) 4 (BY MFR) WP (BY MFR) TENANT PANEL 'T1' 5 NEW 400 AMP TENANT PANEL 'T2' 5 WH-12 (T2-40,42) EF-1 1(T2-1) 1. 20A, 120V-1Ø MOTOR CONNECTION FOR EXHAUST FAN. 2. 20A, 208V-1Ø CONNECTION FOR WATER HEATER. 3. 35A, 208V-3Ø CONNECTION FOR RTU. INSTALL 3-#8, 1-#8 GND IN A 3/4"C. 4. DUCT DETECTOR SHALL SHUT DOWN RTU UPON ACTIVATION. 5. INSTALL 4" CONDUIT WITH PULL WIRE FOR INCOMING PHONE/I.T. SERVICE. STUB-OUT CONDUIT 5' BEYOND BUILDING AND CAP. 6. EXISTING LIGHT FIXTURES IN THIS AREA ARE TO REMAIN. 7. RELOCATE EXISTING LIGHT FIXTURE TO THIS LOCATION. EXTEND EXISTING BRANCH CIRCUIT WIRING TO NEW LOCATION. 8. NEW FIXTURE SHALL MATCH EXISTING. 9. PROVIDE NEW EXIT/EMERGENCY LIGHT COMBO UNIT. NEW ELECTRICAL PANEL WITH TENANT. 10. CONTRACTOR SHALL CONFIRM EXACT LOCATION OF NEW ELECTRICAL PANEL WITH TENANT. LOCATION OF NEW 400 AMP PANEL; SEE ONE-LINE ON SHEET E4. 11. 20A, 120V-1Ø CONNECTION FOR EXTERIOR SIGNAGE VERIFY EXACT LOCATION WITH TENANT. PLAN NOTES:# A. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE, AND SHALL CONFORM WITH ALL FEDERAL, STATE, AND LOCAL CODES AND STANDARDS. B. THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT, AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. C. CONSTRUCTION DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, HOWEVER, SYSTEMS HAVE BEEN SHOWN DIAGRAMMATICALLY AND IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL FITTINGS, AND/OR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR. D. ALL CIRCUITS OVER 100' IN LENGTH SHALL BE A MINIMUM #10 AWG CONDUCTOR. E. WIRING SYSTEM SHALL BE CONDUIT AND WIRE. MINIMUM WIRE SIZE SHALL BE #12 AWG. USE SOLID CONDUCTOR FOR #10 AWG AND SMALLER, USE STRANDED IN LARGER SIZES. F. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE OWNER. G. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY CONDUIT, WIRING, PANELS, LIGHTING, ELECTRICAL DEVICES, SWITCHES AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. H. INSTALL GROUND WIRE IN ALL FEEDERS AND BRANCH CIRCUITS. I. MINIMUM CONDUIT SIZE SHALL BE 3/4". J. ALL DEDICATED RECEPTACLES SHALL BE 20 AMP RATED. GENERAL NOTES: GFI A/C (T2-2) T2-4 T2-4 T2-4 T2-4 T2-4 T2-4 T2-4 T2-4 T2-4 T2-4 T2-4 T2-4 T2-6 9 T2-6 9 T2-6 9 T2-6 T2-6 T2-6 (T2-37,39,41) 7 10 T2-4 OS 6 6 6 6 T2-6 DISPLAYRISER NEW TENANT SPACE 'A' 100 STORAGE 101 ADA RR 102 NEW TENANT SPACE 'B' 200 NEW ADA RR 201 11T1-2 (E.T.R.) 11T1-8 (E.T.R.) (E.T.R.) (E.T.R.) 8 EXISTING EXISTING EXISTING EXISTINGEXISTING EXISTING EXISTINGEXISTING EXISTINGEXISTING EXISTING NEW THE PLANS, IDEAS & DESIGNS REPRESENTED HERE ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF APRIL MCCLURG DESIGN CO. ALL RIGHTS RESERVED, EXCEPT WHEN WRITTEN CONSENT IS GIVEN. CONTRACTORS ARE TO VERIFY AND ARE RESPONSIBLE FOR ALL JOB SITE DIMENSIONS.UNIT 130- DIVIDEWEST CARMEL 'B' SHOPPES9873 NORTH MICHIGAN ROADCARMEL, INDIANA 46032Mechanical, Electrical, & Energy Engineering 2707 Rand Road Indianapolis, In 46241 voice: 317-464-9090 fax: 317-464-9393 www.daengineering.com DESIGN-AIRE ENGINEERING, INCSOUTH BUILDINGISSUE: SUBMITTAL SET DATE: 11/18/2021 E-3 FLOOR PLAN - ELECTRICAL 01/03/22