HomeMy WebLinkAboutS100.2 - First Floor New Const (Right)58'-11"38'-11"30'-1"
40'-7" 18'-4"
3'-4" 10'-0" 2'-2" 1'-0"2'-0" 10'-0" 2'-8" 10'-0" 2'-8" 10'-0" 2'-8" 10'-0" 2'-0"
1'-0"
1'-6"
KITCHEN
BAR /
LOUNGE
60'-0"
23'-4"
2'-4"
25'-0" 5'-2"
OUTDOOR
ENTERTAINING
COVERED
SCREENED
PORCH
K-3322-RAGABRIELLETOILETSVITREOUS CHINA
NEW 4-CAR
GARAGE
1'-4"5'-2"
2'-6" 6'-4 1/2" 6'-1 1/2" 17'-8" 11'-4"6"56'-0"6"
1'-4"23'-4" 32'-6"6"26'-2"6"6'-0"6"22'-6" 2'-8" 6'-0"6"11'-3" 11'-3"1'-4" 1'-4"EXISTING
3-CAR
GARAGE 45'-6" 26'-8" 23'-3"104'-4"15'-10 1/2" 7'-4 1/2" 2'-10" 20'-9" 12'-7" 23'-0"
SERVICE
KITCHEN
COVERED OPEN
AIR GRILLE PORCH
15'-0" 7'-0 1/2"K-3322-RAGABRIELLETOILETSVITREOUS CHINA
8'-4" 4'-2" 2'-6" 4'-2"11'-3" 11'-3"14'-0"
6"
8'-5 3/4" 5'-6 1/4"5 1/2"8'-11"5 1/2"9'-6 1/2"5 1/2"7'-0"6"7'-6 1/2"1'-4"10'-10" 20'-4 1/2" 6'-4" 8'-11 1/2"6"6'-0"6"15'-9"6"31'-6" 3'-6" 11'-6"6"
18'-8" 6" 6"2'-6" 6"15'-0" 12'-2" 10 1/2"8'-2 1/2"7'-3" 6'-0" 4'-0"10 1/2"17'-3"6'-0 1/2"
PANTRY
CLG. AT 10'
BULKHEAD
AT 9'-2"
BULKHEAD
AT 9'-7"
BULKHEAD
AT 9'-7"
SLOPED
GLASS ROOF
℄℄6"4'-0"6"22'-2"1'-8"2'-6" 6" 5'-5" 5 1/2" 8'-5 1/2" 5 1/2" 7'-5 1/2" 5 1/2" 6'-6"5 1/2"
2'-4" 6'-3" 2'-2 1/2" 5'-6 7/8" 2'-2 1/2" 6'-3"11'-4" 12'-0"6"1'-10" 11'-4" 19'-5"5 1/2"6'-4"5 1/2"8'-6"6"
24'-0"
1'-4"6'-3 1/2" 6" 2'-7" 19'-11" 1'-4"9'-10" 9'-10" 4'-0" 5'-0" 20'-0"12'-10" 13'-10" 17'-3 1/2"1'-4"6'-4" 2'-6"3'-4" 19'-4"1'-4"17'-8" 5 1/2"45'-0 1/2"144" x 48"
island
144" x 48"
island
3/0
8/0
3/0
8/0
3/0
8/0
3/0
8/0
3/0
8/0
APPROX
3/0
8/0
3/0
8/0
3/0
8/0
3/0
8/0
3/0
8/0
pr
3/0
8/0
22'-0" WIDE by 8'-0"
high STEEL FRAMED
WINDOW and door
assembly. hd.@ 8'-0"
20'-0" WIDE by 10'-0"
high STEEL FRAMED
sliding pocket door
assembly. hd.@ 10'-0"
24'-0" WIDE by 10'-0"
high STEEL FRAMED
bi-fold door
assembly. hd.@ 10'-0"
with arched transom
to match. top of arch
at 15'-7" - see
elevations
retractable
electronically operated
automatic screens with
recessed tracks
s&r s&rBAR BASE
AND WALL
CABINETRY
TBD.
10'x8' OHD. WITH
(3)- 1 3/4" X 18" LVL
HEADERS AS REQUIRED
SPECIAL NOTE:
DESIGN ALL 2ND FLOOR
"TRUSS JOIST" WITH A
DEFLECTION NOT TO
EXCEED L/720. TYPICAL.FLR. TRUSSES @ MFGR.RECOMMENDEDSPACING AND DEPTHG.C. VERIFY10'x8' OHD. WITH
(3)- 1 3/4" X 18" LVL
HEADERS AS REQUIRED
10'x8' OHD. WITH
(3)- 1 3/4" X 18" LVL
HEADERS AS REQUIRED
10'x8' OHD. WITH
(3)- 1 3/4" X 18" LVL
HEADERS AS REQUIREDFLR. TRUSSES @ MFGR.RECOMMENDEDSPACING AND DEPTHG.C. VERIFY13'-9 1/2" 21'-9 1/2" 5'-0" 1'-4"17'-0"
21'-1" WIDE by 10'-0"
high STEEL FRAMED
WINDOW AND DOOR
ASSEMBLY with
slope glazing roof
21'-1"
doors will
be a pair
of approx.
3'-0" +/-
wide and
10'-0" tall
12'-0" WIDE ARCHED
STEEL FRAMED
WINDOW WITH TOP OF
NEW STEEL FRAMED
WINDOW TO FIT WITHIN
THE EXISTING
OPENING. BUILD
DOWN FOR NEW ARCH.
1'-8" WIDE BY
12'-8" HIGH STEEL
FRAMED WINDOW
TO FIT EXISTING
OPNG. HD.
EXISTING @ 12'-8"
1'-8" WIDE BY
12'-8" HIGH STEEL
FRAMED WINDOW
5'-0" WIDE BY
4'-10" HIGH STEEL
FRAMED WINDOW
TO FIT EXISTING
OPNG. HD.
EXISTING @ 96"
8'-0" WIDE ARCHED
STEEL FRAMED WINDOW
16'-8" TO
STEEL
FRAMED
doors will
be a pair
of approx.
3'-0" +/-
wide and
10'-0" tall
16'-0" WIDE BY 7'-0" STEEL
FRAMED AND WINDOW WITH
3'-0" X 8'-0" DOOR
ASSEMBLY. HD. AT 96".
WIC.
LAUN.
W.
D.
ROLLING SHUTTER
DOOR G.C. VERIFY
BUILT-IN SERVICE
COUNTER WITH
BASE CABINETS
ARCHED
BULKHEAD SEE
ELEVATIONS
EXISTING CONSTRUCTION
TO REMAIN
LINE OF SECOND
FLOOR ABOVE
ALL MASONRY
FIREPLACE G.C.
VERIFY SIZE
REQUIRED
5'-0" WIDE BY 7'-10"
HIGH STEEL FRAMED
WINDOW. HD. @ 108"
14'-4"5 1/2"14'-5"
9'-4" WIDE BY
8'-0" STEEL
FRAMED DOOR
AND WINDOW
ASSEMBLY WITH
PAIR OF 3'-0"
X 8'-0" DOOR.
HD. AT 96".
built-in BASE
AND WALL
CABINETS TBD.
built-in BASE
AND WALL
CABINETS TBD.
NEW OVERHEAD DOORS
IN EXISTING OPENINGS.
G.C. VERIFY EXISTING
LINE OF NEW SECOND
FLOOR ABOVE
LINE OF NEW SECOND
FLOOR ABOVE
ARCHED
BULKHEAD -
SEE EXTERIOR
ELEVATIONS
DN. TO UNFIN.EXIST. BSMT. up 19 r.HEADER AS
REQUIRED FLR. TRUSSES @ MFGR.RECOMMENDEDSPACING AND DEPTHG.C. VERIFYEXISTING 14" "I"
joists @ 16" O.C.EXISTING 14" "I"joists @ 16" O.C.EXISTING 14" "I"joists @ 16" O.C.8'-11"6'-1"2'-4 1/4" 20'-4 1/2" 1'-1 1/4"8"25'-2" 25'-6" 4'-11"3'-9"1'-4"1'-0"
9" 9"bulkhead @ 8'-6"
bulkhead @ 10'-0"
up 19 r. to future expansionCATH. CLG.CATH. CLG. CATH. CLG.CATH. CLG. pr.
2/0
8/0
bulkhead
@ 10'-0"
custom
built-in
seating
60"
v.
raised
hearth
1'-8" 4'-5" 1'-8"
11'-0" x 14'-10" X 5'-0"
HIGH STEEL WINDOW
CORNER ASSEMBLY.
HD. @ 96"
4'-0" WIDE BY 7'-0"
HIGH STEEL FRAMED
WINDOW. HD @ 96"
POST RIDGE BEAM
AS REQUIRED FROM
LOWER BEAM
POST RIDGE BEAM
AS REQUIRED FROM
LOWER BEAM
LINE OF ROOF
CURVE OVER
ARCHED TRANSOM
INTO VAULTED
CEILING
3/0
8/0 20'-1 3/4"1'-1 1/4"2021-0428
07-05-2021
Project No:
Sheet Title
REVISIONS
Date:
Sheet No.1122 Laurelwood Dr.Carmel, IN 46032THE LAW FAMILYRESIDENCEAddition to and Renovation of the:GARY NANCE DESIGNArchitectural Concepts By200 Sout h Rangeline Road, Sui te 214 Carmel, IN 46032317.605.2196 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval f rom Gary Nance DesignA R C H I T E C T S+A S S O C I A T E S2520 Durbin DriveCarmel , Indiana 46032317-733-8525hsark@sarkassociates.comFIRST FLOOR
RIGHT NEW
CONSTR. PLAN
A-4.2
FIRST FLOOR (RIGHT) - NEW CONSTRUCTION PLAN
SCALE: 1/4" = 1'-0" TOTAL LIVING (NEW AND EXISTING) = 8458 SQ. FT.U:\02-RESIDENTIAL L-Z\Nance, G\2021-0428-Law Laurelwood\01-CDs\2021-0428_Scott Law - Laurelwood_NC FFP.dwg, 7/5/2021 6:37:11 PM,_DWG To PDF.pc308/11/21