Loading...
HomeMy WebLinkAboutS100.2 - First Floor New Const (Right)58'-11"38'-11"30'-1" 40'-7" 18'-4" 3'-4" 10'-0" 2'-2" 1'-0"2'-0" 10'-0" 2'-8" 10'-0" 2'-8" 10'-0" 2'-8" 10'-0" 2'-0" 1'-0" 1'-6" KITCHEN BAR / LOUNGE 60'-0" 23'-4" 2'-4" 25'-0" 5'-2" OUTDOOR ENTERTAINING COVERED SCREENED PORCH K-3322-RAGABRIELLETOILETSVITREOUS CHINA NEW 4-CAR GARAGE 1'-4"5'-2" 2'-6" 6'-4 1/2" 6'-1 1/2" 17'-8" 11'-4"6"56'-0"6" 1'-4"23'-4" 32'-6"6"26'-2"6"6'-0"6"22'-6" 2'-8" 6'-0"6"11'-3" 11'-3"1'-4" 1'-4"EXISTING 3-CAR GARAGE 45'-6" 26'-8" 23'-3"104'-4"15'-10 1/2" 7'-4 1/2" 2'-10" 20'-9" 12'-7" 23'-0" SERVICE KITCHEN COVERED OPEN AIR GRILLE PORCH 15'-0" 7'-0 1/2"K-3322-RAGABRIELLETOILETSVITREOUS CHINA 8'-4" 4'-2" 2'-6" 4'-2"11'-3" 11'-3"14'-0" 6" 8'-5 3/4" 5'-6 1/4"5 1/2"8'-11"5 1/2"9'-6 1/2"5 1/2"7'-0"6"7'-6 1/2"1'-4"10'-10" 20'-4 1/2" 6'-4" 8'-11 1/2"6"6'-0"6"15'-9"6"31'-6" 3'-6" 11'-6"6" 18'-8" 6" 6"2'-6" 6"15'-0" 12'-2" 10 1/2"8'-2 1/2"7'-3" 6'-0" 4'-0"10 1/2"17'-3"6'-0 1/2" PANTRY CLG. AT 10' BULKHEAD AT 9'-2" BULKHEAD AT 9'-7" BULKHEAD AT 9'-7" SLOPED GLASS ROOF ℄℄6"4'-0"6"22'-2"1'-8"2'-6" 6" 5'-5" 5 1/2" 8'-5 1/2" 5 1/2" 7'-5 1/2" 5 1/2" 6'-6"5 1/2" 2'-4" 6'-3" 2'-2 1/2" 5'-6 7/8" 2'-2 1/2" 6'-3"11'-4" 12'-0"6"1'-10" 11'-4" 19'-5"5 1/2"6'-4"5 1/2"8'-6"6" 24'-0" 1'-4"6'-3 1/2" 6" 2'-7" 19'-11" 1'-4"9'-10" 9'-10" 4'-0" 5'-0" 20'-0"12'-10" 13'-10" 17'-3 1/2"1'-4"6'-4" 2'-6"3'-4" 19'-4"1'-4"17'-8" 5 1/2"45'-0 1/2"144" x 48" island 144" x 48" island 3/0 8/0 3/0 8/0 3/0 8/0 3/0 8/0 3/0 8/0 APPROX 3/0 8/0 3/0 8/0 3/0 8/0 3/0 8/0 3/0 8/0 pr 3/0 8/0 22'-0" WIDE by 8'-0" high STEEL FRAMED WINDOW and door assembly. hd.@ 8'-0" 20'-0" WIDE by 10'-0" high STEEL FRAMED sliding pocket door assembly. hd.@ 10'-0" 24'-0" WIDE by 10'-0" high STEEL FRAMED bi-fold door assembly. hd.@ 10'-0" with arched transom to match. top of arch at 15'-7" - see elevations retractable electronically operated automatic screens with recessed tracks s&r s&rBAR BASE AND WALL CABINETRY TBD. 10'x8' OHD. WITH (3)- 1 3/4" X 18" LVL HEADERS AS REQUIRED SPECIAL NOTE: DESIGN ALL 2ND FLOOR "TRUSS JOIST" WITH A DEFLECTION NOT TO EXCEED L/720. TYPICAL.FLR. TRUSSES @ MFGR.RECOMMENDEDSPACING AND DEPTHG.C. VERIFY10'x8' OHD. WITH (3)- 1 3/4" X 18" LVL HEADERS AS REQUIRED 10'x8' OHD. WITH (3)- 1 3/4" X 18" LVL HEADERS AS REQUIRED 10'x8' OHD. WITH (3)- 1 3/4" X 18" LVL HEADERS AS REQUIREDFLR. TRUSSES @ MFGR.RECOMMENDEDSPACING AND DEPTHG.C. VERIFY13'-9 1/2" 21'-9 1/2" 5'-0" 1'-4"17'-0" 21'-1" WIDE by 10'-0" high STEEL FRAMED WINDOW AND DOOR ASSEMBLY with slope glazing roof 21'-1" doors will be a pair of approx. 3'-0" +/- wide and 10'-0" tall 12'-0" WIDE ARCHED STEEL FRAMED WINDOW WITH TOP OF NEW STEEL FRAMED WINDOW TO FIT WITHIN THE EXISTING OPENING. BUILD DOWN FOR NEW ARCH. 1'-8" WIDE BY 12'-8" HIGH STEEL FRAMED WINDOW TO FIT EXISTING OPNG. HD. EXISTING @ 12'-8" 1'-8" WIDE BY 12'-8" HIGH STEEL FRAMED WINDOW 5'-0" WIDE BY 4'-10" HIGH STEEL FRAMED WINDOW TO FIT EXISTING OPNG. HD. EXISTING @ 96" 8'-0" WIDE ARCHED STEEL FRAMED WINDOW 16'-8" TO STEEL FRAMED doors will be a pair of approx. 3'-0" +/- wide and 10'-0" tall 16'-0" WIDE BY 7'-0" STEEL FRAMED AND WINDOW WITH 3'-0" X 8'-0" DOOR ASSEMBLY. HD. AT 96". WIC. LAUN. W. D. ROLLING SHUTTER DOOR G.C. VERIFY BUILT-IN SERVICE COUNTER WITH BASE CABINETS ARCHED BULKHEAD SEE ELEVATIONS EXISTING CONSTRUCTION TO REMAIN LINE OF SECOND FLOOR ABOVE ALL MASONRY FIREPLACE G.C. VERIFY SIZE REQUIRED 5'-0" WIDE BY 7'-10" HIGH STEEL FRAMED WINDOW. HD. @ 108" 14'-4"5 1/2"14'-5" 9'-4" WIDE BY 8'-0" STEEL FRAMED DOOR AND WINDOW ASSEMBLY WITH PAIR OF 3'-0" X 8'-0" DOOR. HD. AT 96". built-in BASE AND WALL CABINETS TBD. built-in BASE AND WALL CABINETS TBD. NEW OVERHEAD DOORS IN EXISTING OPENINGS. G.C. VERIFY EXISTING LINE OF NEW SECOND FLOOR ABOVE LINE OF NEW SECOND FLOOR ABOVE ARCHED BULKHEAD - SEE EXTERIOR ELEVATIONS DN. TO UNFIN.EXIST. BSMT. up 19 r.HEADER AS REQUIRED FLR. TRUSSES @ MFGR.RECOMMENDEDSPACING AND DEPTHG.C. VERIFYEXISTING 14" "I" joists @ 16" O.C.EXISTING 14" "I"joists @ 16" O.C.EXISTING 14" "I"joists @ 16" O.C.8'-11"6'-1"2'-4 1/4" 20'-4 1/2" 1'-1 1/4"8"25'-2" 25'-6" 4'-11"3'-9"1'-4"1'-0" 9" 9"bulkhead @ 8'-6" bulkhead @ 10'-0" up 19 r. to future expansionCATH. CLG.CATH. CLG. CATH. CLG.CATH. CLG. pr. 2/0 8/0 bulkhead @ 10'-0" custom built-in seating 60" v. raised hearth 1'-8" 4'-5" 1'-8" 11'-0" x 14'-10" X 5'-0" HIGH STEEL WINDOW CORNER ASSEMBLY. HD. @ 96" 4'-0" WIDE BY 7'-0" HIGH STEEL FRAMED WINDOW. HD @ 96" POST RIDGE BEAM AS REQUIRED FROM LOWER BEAM POST RIDGE BEAM AS REQUIRED FROM LOWER BEAM LINE OF ROOF CURVE OVER ARCHED TRANSOM INTO VAULTED CEILING 3/0 8/0 20'-1 3/4"1'-1 1/4"2021-0428 07-05-2021 Project No: Sheet Title REVISIONS Date: Sheet No.1122 Laurelwood Dr.Carmel, IN 46032THE LAW FAMILYRESIDENCEAddition to and Renovation of the:GARY NANCE DESIGNArchitectural Concepts By200 Sout h Rangeline Road, Sui te 214 Carmel, IN 46032317.605.2196 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval f rom Gary Nance DesignA R C H I T E C T S+A S S O C I A T E S2520 Durbin DriveCarmel , Indiana 46032317-733-8525hsark@sarkassociates.comFIRST FLOOR RIGHT NEW CONSTR. PLAN A-4.2 FIRST FLOOR (RIGHT) - NEW CONSTRUCTION PLAN SCALE: 1/4" = 1'-0" TOTAL LIVING (NEW AND EXISTING) = 8458 SQ. FT.U:\02-RESIDENTIAL L-Z\Nance, G\2021-0428-Law Laurelwood\01-CDs\2021-0428_Scott Law - Laurelwood_NC FFP.dwg, 7/5/2021 6:37:11 PM,_DWG To PDF.pc308/11/21