Loading...
HomeMy WebLinkAboutimg008.pdfNOTICE 0F CORRECTIONS CTIT oF cAREmL / cIA¥ TowNslm DEPAIIMENT OF cOMMiINH-y sERlvlcEs - BunDING & CODE sERvlcEs ONE CIVIC SQu^RE - C^RMEL, IN 46032 PHONE (3i7) 57r2444 - FAx (317) 571-2499 ~ wwwc^RMELIN.cK3v PERMIT # 8-2020-00801 LOCATION 55 4th Aye SE BulLDER Skillman Construction FtE-lNSPECTION FOR ]TEM/S NOTED SHOULD BE SCHEDULED WITHIN 30 DAYS OF THIS NOTICE 0R LATE FEES MAY BE ASSESSED. I N ORDER T0 SCHEDULE, PLEASE CONTACT ThE OFFICE 4l+EA§:I: ONE DAY PFiloR T0 THE REQUESTED [NSPECTloN DATE. COMMENTS/ ITEMS: Footing poured without an inspection performed on 03/01/2021. Late fee applied. Beport required from engineering firm for footing poured and entire report for footings by engineering on site. OK TO INSULATE. (DO A!Q| INsl.ALL DRYWALL-ONLY INSULATloN.) HyesHNo **************************************************************************************** A S_7P=0_0____ Residential Re-inspection Fee is assessed. EYes ENo A SJ£§=0_0___ Commercial/Institutional/Multi-Family Re-inspection Fee is assessed. EZ]Yes ENo **************************************************************************************** A Late Fee is assessed for No inspection scheduled prior to pouring last grade beam footing. intheamountofHS-7£|o-o-----ESJJ?§=o-o----ESJ£g§=o-o---- Resideiitlal other Single/Two-Family/Town Home Commercial/Institutional/Multi-Family **************************************************************************************** lNSPECTOR Adam schriner DATE 03/02/2020 Alt & Witzig Engineering, Inc. 4105 West 99th Street . Carmel, IN 46032 (317) 875-7040. FAX (317) 876-3705 page 1 ofl Tested For: Mr. Kevin Gujral The Skillman Corporation (Indianapolis) 3834 S. Emerson Ave., Bldg. A Indianapolis, IN 46203 Project: Carmel Clay Public Library Renovation PO 002 55 4th Ave SE Carmel , IN A&W Project TD20306 Inspection Date: Monday, March 1, 2021 Report No: TD20306-FTG-A FOOTING INSPECTION Type of Footings: Wall footing with column pads Location of Footings: West of Elevator pit The above referenced footing excavations were inspected at design elevation. A visual classification of the soil, housel penetrometer and hand penetrometer tests were performed on the materials in the base of the footings. Our test results indicate soil strengths at or above 2000 psf to a depth of eighteen (18) inches below design elevation. Sr. Engineering Technician: Zach Sullivan SUBSURFACE INVESTIGATION AND FOUNDATION ENGINEERING CONSTRUCTION M^TF,RI^LS TESTING AND INSPECTTON ENVIRONMENTAL SERVICES Alt & Witzig Engineering, Inc. 4] 05 West 99th Street . Carmel, IN 46032 (317) 875-7040 . FAX (317) 876-3705 page I of 1 Tested For: Mr. Kevin Gujral The Skillman Corporation (Indianapolis) 3834 S. Emerson Ave., Bldg. A Indianapolis, IN 46203 Report No: TD20306-CON-A Date: Monday, March 1, 202l Project: Carmel Clay Public Library Renovation PO 002 55 4th Ave SE Carmel , IN In response to your request, our engineering technician performed testing and inspection of the Concrete placement at the above referenced project. The results of the field inspection and corresponding laboratory testing are summarized below. Type of structure: Wall Footing w/ Column pads Location of placement: Footings west of elevator pad Date of pour: Air Temp. (F): Concrete Temp. (F): No. of Cylinder: Slump (in): Type of Concrete: 3/ 1 /2021 40 60 5 4 3000 psi F30102 Compression Test Results Nominal Cylinder Size 4 x 8 Cure D ate Age N o. Eq2£ Tested Qa][§ 1132119 1132120 1132121 1132122 1132123 03/08/21 03/08/21 03/29/21 03/29/21 03/29/21 Specification Requirement at 28 days: 3000 psi. Supplier, Supplier Ticket No. : Time Truck Dispatched: Time Truck Unloaded: Cubic Yds - Per Truck: Cubic Yds - Cumulative: Shelby Materials 021-122359 3:22 PM 4:30 PM 9 9 Reference No.: 322229 Date Received: 3/2/2021 Samples Picked Up By Alt & Witzig Personnel SUBSURFACE INVESTIGATION AND I.`OUNDATI()N ENGINEERING C()NSTRUCTION M^TERl^LS TF,STING AND INSPEC`TION ENVIRONMENTAL SERVICES