HomeMy WebLinkAbout42230018 - GR2 72 - Floor LayoutLayout Name 72 Gramercy Description 9799 B Created June 21, 2019 Revised December 06, 2021 Builder David Weekley Homes Sales Rep Jeremiah Maeda Designer Juan C. Varela Contract Lumber 200 Schofield Drive Columbus , OH 43213 614.751.1109 2nd Flr. I Joist Label Description Width Depth Qty Plies Pcs Length J1 LPI 20Plus 2.5 14 2 3-8-12 J3 LPI 20Plus 2.5 14 13 17-9-6 J7 LPI 20Plus 2.5 14 13 21-9-12 J9 LPI 20Plus 2.5 14 3 17-9-12 LVL/LSL Label Description Width Depth Qty Plies Pcs Length DB4 LP-LSL 1.55E 1.75 9.25 1 2 2 12-0-0 F1 LP-LSL 1.75E 1.75 14 1 3-8-12 F2 LP-LSL 1.75E 1.75 14 1 6-0-0 F3 LP-LSL 1.75E 1.75 14 1 2 2 22-0-0 DB3 LP-LVL 2900Fb-2.0E 1.75 18 1 2 2 20-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length R1 LP APA Rated OSB 1.125 X 14 1.125 14 12 12-0-0 Lumber Label Description Width Depth Qty Plies Pcs Length D1 SP #2 1.5 5.5 1 2 2 4-0-0 D2 SP #2 1.5 5.5 6 4-0-0 D3 SP #2 1.5 7.25 1 2 2 4-0-0 DB1 SP #2 1.5 9.25 1 2 2 6-0-0 DB2 SP #2 1.5 9.25 1 2 2 18-0-0 Hanger Beam/Girder Supported Member Label Pcs Description Skew Slope fasteners fasteners H1 1 THF17140 (Max) 20 10d 2 10dx1 1/2 H3 14 IHFL2514 (Min) 12 10d 2nd Flr. Design Method ASD (USA) Building Code IRC 2018 Floor Loads Live 40 Dead 10 Deflection Joist LL Span L/480 TL Span L/240 LL Cant 2L/480 TL Cant 2L/240 Deflection Girder LL Span L/480 TL Span L/240 LL Cant 2L/480 TL Cant 2L/240 Decking Decking OSB 23/32 APA Rated Sturd- I-Floor Fastener Nailed & Glued ADJUST PLUMBING TO AVOID JOIST FLANGE (3) 2x6 A3 A7 E1N A7 2 JACKS REQUIRED EA. END A3A3 36"x36" DB3 ( 2 ply ) F2 ( 1 ply ) F1 ( 1 ply ) DB2 ( 2 ply ) D2 ( 1 ply ) D2 ( 1 ply ) D2 ( 1 ply ) PS General Notes - It is the sole responsibility of the builder/installer to follow this layout exactly. Notify Contract Lumber of any discrepancies between this layout and field conditions. Contract Lumber is not liable for any field changes without prior approval. - Refer to details in the installation guide prior to construction ROOF GIRDER TRUSS D2 ( 1 ply ) D2 ( 1 ply )D2 ( 1 ply ) D2 ( 1 ply ) D4 ( 1 ply )D4 ( 1 ply ) Roof Lumber Label Description Width Depth Qty Plies Pcs Length D2 SP #2 1.5 5.5 9 4-0-0 D4 SP #2 1.5 7.25 2 4-0-0 1.LB-: Lateral bracing is required along the top of the beam where this symbol is present. The number "- #" in the label represents the maximum on center spacing in feet for the required lateral bracing. This number may vary for different beams. If you are unsure how to apply the lateral bracing please contact the design professional for this job. Version 20.60.158Powered by iStruct¥ This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them 01/04/22