Loading...
HomeMy WebLinkAboutS1-4 - NVL 325 - 08 Sections 1-4H. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720- Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174 - www.hgmccullough.comMake yourself at homeMcKENZIECOLLECTION.COM4631 Lisborn Drive Carmel, IN 46033317.574.7617 PDate: 11-23-2021Plan number #210224Designed For:Will and Emily Turner1'-434" 9'-118"1'-434" 9'-912" 10'-0"FOUNDATION WALL HEIGHT10'-118" BEDROOM #4 34" T&G OSB SUB. FL. 16 JST @ 16" O.C. 12 PITCH 8 1 FRAMING SECTION INSUL. BATTS 2 PLY"x16" FLUSH LVL HDR. w/JST HANGERS TRUSSES 24" o.c. T.C. L.L. 30 PSF T.C. D.L. 10 PSF B.C. D.L. 10 PSF B.C. L.L. 0 PSF TOTAL 50 PSF NOTE: TRUSS DESIGN BY MFG. W14x34# STEEL BEAM ENTRY FOYER DINING ROOM COVERED OUTDOOR LIVING AREA REAR GALLERY HALL SNACK/BEVERAGE BAR VERANDA FITNESS SITTING AREA 10'-118" 2-PLYx1178 LVL HEADER 12 PITCH 10 GRAVEL FILL RUBBER FLASHING 16 JST @ 16" O.C. 3 4" T&G OSB SUB. FL. GRAVEL FILL RUBBER FLASHING 2-PLYx16 LVL HEADER 112" 2716" STEPSLOPE4" CONC. SLAB W/ 6x6 #10 WWF EXPOSED AGGR. 10" CONC. WALL w/ VERT. #6 REBARS 36" o.c. & (4) #4 HORZ. REBARS CONT. (LAP 24" AS NECESSARY) #3 DOWELS x 18 LONG @ 36" o.c. 1'-412" 1'-412"2'-378" 20'-10116"7'-4"25'-018"2'-1078" 20'-81316"2'-5116"7 16 " DECKING 15# ASPHALT SAT. FELT, EXCEPT IN HIGH RISK AREAS USE ICE & WATER SHIELD MEMBRANE COMPOSITE SHAKES BLOWN INSUL. R-50 9'-378"HEELHEIGHTHEEL HEIGHTTOP OF TRUSS WOOD TIMBER 4" CROSS-0VER DRAIN THROUGH FOOTING @ (1) LOCATION ON EACH SIDE OF FOUNDATION TYP. 1'-4" 5'-712"22'-0" 11'-0" 3 4" T&G OSB SUB. FL. 16 JST @ 16" O.C. 12 PITCH8 12 PITCH10 TRUSSES 24" o.c. T.C. L.L. 30 PSF T.C. D.L. 10 PSF B.C. D.L. 10 PSF B.C. L.L. 0 PSF TOTAL 50 PSF NOTE: TRUSS DESIGN BY MFG. 2 FRAMING SECTION W10x15# STEEL BEAM LIVING ROOMBATHROOM GUEST BEDROOM CLOSET AIR SPACE STONE VENEER 7/16" O.S.B. SHEATHING ZIP WALL W/ TAPPED JOINTS 1'-434" 9'-912" 10'-118"11'-912"4" DIA. PERF PIPE w/SOCK WATERPROOFING AS SPECIFIED BY GENERAL CONTRACTOR GRAVEL FILL WRAP WASH GRAVEL BACKFILL w/ LANDSCAPE FELT MAT'L. TOP OF LOWER LEVEL CONCRETE SLAB 1'-412" FULL THK FRICTION FIT FIBERGL INSUL. BATTS R-15 2x4 STUDS 16" O.C. w/ 12" DRYWALL 2'-0"4" MIN. GRAVEL FILL 6 MIL POLYETHYLENE VAPOR BARRIER 4" CONC. SLAB 3500 PSI 2'-378" 9'-41516"11'-312" 11'-312" 1'-5"HEELHEIGHTTOP OF TRUSS 10'-0"FOUNDATION WALL HEIGHTBATHROOM CLOSET GOLF SIMULATOR GUEST BEDROOM BLOWN INSUL. R-50 12'-0"FOUNDATION WALL HEIGHTSLOPED STONE SILL 3 4" T&G OSB SUB. FL. 4" CROSS-0VER DRAIN THROUGH FOOTING @ (1) LOCATION ON EACH SIDE OF FOUNDATION TYP. EXTERIOR WALL, ROOF WATERPROOFING & FLASHING AS PER CONTR.10'-8716"AREA FOR SUMP PIT 12 PITCH 12 3 FRAMING SECTION 4 FRAMING SECTION TOP OF MAIN LEVEL SUB FL. BEDROOM #4 2 CAR BAY GARAGE BEDROOM #2 16 JST @ 16" O.C. 12 PITCH12 2" MINIMUM SLOPED CONCRETE SLAB4" CONC. SLAB W/ 6x6 #10 WWF EXPOSED AGGR. GRAVEL FILL 1'-5"3 12" 12'-8" 12'-8" 312" 1'-5" SEAT CUT SEAT CUT 2 x 8 RA F T E R S 1 6 " O. C. 2X4 NAILER INSULATION BAFFLE STOP 2x6 JOIST 16" O.C. 2x6 JOIST 16" O.C.2x8 RAF TERS 16" O.C.TOP OF MAIN LEVEL SUB FL.10'-118" 1'-434" 1'-9516" 13'-512"2 PLY"x16" FLUSH LVL JST. 2 PLY"x16" FLUSH LVL JST. AIR SPACE STONE VENEER 7/16" O.S.B. SHEATHING ZIP WALL W/ TAPPED JOINTS BRICK VENEER 2" RIGID INSULATION1'-614" 10'-118" 1'-434" 1'-2916" 13'-112"1'-5" 312" 12'-4" 12'-4" 312" 4'-214" SEAT CUT SEAT CUTTOP OF RIDGE BEAM TOP OF RIDGE BEAM TOP OF GARAGE FOUNDATION 1 2" EDGE 6 MIL POLYETHYLENE VAPOR BARRIER 4" CONC. SLAB 3500 PSI 2-PLYx1178 LVL HEADER9'-118"7 16 " DECKING 15# ASPHALT SAT. FELT, EXCEPT IN HIGH RISK AREAS USE ICE & WATER SHIELD MEMBRANE COMPOSITE SHAKES INSULATION BAFFLE STOP 2X4 NAILER BLOWN INSUL. R-50 DRAFT STOP 134" X 1178" RIDGE BEAM 11'-10716"12'-91516" TOP OF GARAGE FOUNDATION10'-01116"2 PLY"x16" FLUSH LVL JST. 2 PLY"x16" FLUSH LVL JST. * Seal all joints between dissimilar materials. * Metal flashing installed to all applicable areas * All building materials (including but not limited to metal flashing, vapor barriers, air/water resistant barriers, thru-wall flashing, etc.) shall be lapped to shed water to the outside of the building envelope * Ridge vents as per contractor/manufacturer specifications * 30# Asphalt sat. felt *7 16" Decking * All edge of roofs at eaves, rakes, valleys, hips and breaks, covered in ice and water shield material or equal. As per manufacturer specifications. * Gutter and downspout locations and install specifications. * Simpson seismic ties or equal to provide a positive connection between truss/rafters and the wall of the structure to resist wind and seismic forces. * Exterior metal drip cap, wall waterproofing and flashing install in all applicable areas with manufacturer specifications. * Window/door waterproofing and flashing install in all applicable areas with manufacturer specifications. * Flashing installed to wall/roof connections. * Flashing installed at connections to two different masonry types. (ie. stone water-table with stone sill and brick above). * Door flashing below the threshold. * Flashing and water proofing top of chimney structure before installing chimney cap. * Chimney exterior and interior metal flashing * Baffle stop insulation installed properly, with correct R-factor. * Low slope roofing material installed as per manufacturer specifications. * Metal roofs to have ice and water shield material or equal, installed as per manufacturer specifications. * Steel angle above windows, doors, and overhead doors to carry masonry as sized and installed as per contractor. * Contractor shall determine appropriate ventilation of exterior eave and rake requirements as per roof assembly and finish materials. GENERAL NOTES, AS PER CONTRACTOR 8SCALE: 1/4"=1'-0"ELEVATIONS Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER"C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 01/04/22