Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
I49130410.24_Estates_at_Towne_Meadow
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). December 8,2021 Johnson, Andrew Pages or sheets covered by this seal: I49130410 thru I49130444 My license renewal date for the state of Indiana is July 31, 2022. 24_Estates_at_Towne_Meadow 24 Estates at Towne Medow IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss GE01 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130410 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:43:51 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-V?kckDIFM18j1ING9V2XgKIa9dq?5mZeLAObotyBOd6 Scale = 1:68.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 38 39 3x4 3x4 4x6 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 20-11-0 20-11-0 -0-11-0 0-11-0 10-5-8 10-5-8 20-11-0 10-5-8 21-10-0 0-11-0 1-3-09-11-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.17 0.08 0.23 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 19 19 20 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 358 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 10-28, 9-29, 11-27 REACTIONS.All bearings 20-11-0. (lb) - Max Horz 37=-197(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 30, 32, 33, 34, 35, 26, 25, 24, 23, 22 except 37=-148(LC 6), 20=-118(LC 7), 36=-152(LC 7), 21=-136(LC 11) Max Grav All reactions 250 lb or less at joint(s) 37, 20, 28, 29, 30, 32, 33, 34, 35, 36, 27, 26, 25, 24, 23, 22, 21 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-9=-126/261, 9-10=-134/272, 10-11=-134/272, 11-12=-126/261 WEBS 10-28=-279/110 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 7-5-8, Corner(3R) 7-5-8 to 13-5-8, Exterior(2N) 13-5-8 to 18-10-0, Corner(3E) 18-10-0 to 21-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 30, 32, 33, 34, 35, 26, 25, 24, 23, 22 except (jt=lb) 37=148, 20=118, 36=152, 21=136. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss GE02 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130411 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:43:52 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-zBI_xZJt7LHafSySjCZmDYqlK1AcqGonaq79LJyBOd5 Scale = 1:30.3 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 4x6 3x6 5x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-4-8 8-4-8 16-9-0 8-4-8 -0-11-0 0-11-0 8-4-8 8-4-8 16-9-0 8-4-8 17-8-0 0-11-0 0-9-03-6-80-9-01-4-34.00 12 2.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.12 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.01 0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 100 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-9-0. (lb) - Max Horz 20=25(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 16, 12, 17, 18, 15 except 19=329(LC 23), 13=329(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 5-4-8, Corner(3R) 5-4-8 to 11-4-8, Exterior(2N) 11-4-8 to 14-8-0, Corner(3E) 14-8-0 to 17-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. 9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 16, 17, 18, 19, 15, 14, 13. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss GE03 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130412 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:43:53 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-ROsN9vJVuePRGbXeHv4?mlNtnQUYZhfwpUtitlyBOd4 Scale = 1:43.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 4x6 3x4 3x4 2x4 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4-8-8 4-8-8 9-5-0 4-8-8 -0-11-0 0-11-0 4-8-8 4-8-8 9-5-0 4-8-8 10-4-0 0-11-0 1-5-06-1-81-5-012.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.35 0.20 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.03 -0.04 0.00 (loc) 18 17 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 121 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 6-16: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)20=0-3-0, 12=0-3-0 Max Horz 20=-132(LC 8) Max Grav 20=429(LC 1), 12=429(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-313/47, 3-4=-275/64, 8-9=-275/64, 9-10=-313/47, 2-20=-356/99, 10-12=-356/99 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-0-8, Exterior(2R) 2-0-8 to 7-4-8, Exterior(2E) 7-4-8 to 10-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss GE04 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130413 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:43:54 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-vaQlMFK8fyXHul6rqdcEIzw2RqqAIA8418cFPByBOd3 Scale = 1:17.3 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 5-4-8 5-4-8 -0-11-0 0-11-0 5-4-8 5-4-8 0-9-02-6-80-3-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.36 0.24 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.00 (loc) 4-5 4-5 l/defl >999 >845 n/a L/d 240 180 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-0, 4=0-1-8 Max Horz 5=55(LC 6) Max Uplift 5=-27(LC 6), 4=-22(LC 10) Max Grav 5=274(LC 1), 4=197(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss GE06 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130414 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:43:55 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-Nm_7ZbLmQGf8Wvh1OK7TrASGUEB21XsDGoMpxeyBOd2 Scale: 1/4"=1' Sheet FrontFull Sheathing1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x4 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-11-0 11-11-0 -0-11-0 0-11-0 5-11-8 5-11-8 11-11-0 5-11-8 12-10-0 0-11-0 1-5-07-4-81-5-012.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.15 0.07 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 11-11-0. (lb) - Max Horz 24=-155(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 20, 21, 22, 18, 17, 16 except 24=-197(LC 6), 14=-178(LC 7), 23=-194(LC 7), 15=-180(LC 6) Max Grav All reactions 250 lb or less at joint(s) 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 except 24=254(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-96/256, 6-7=-117/294, 7-8=-117/294, 8-9=-96/256 WEBS 7-19=-343/93 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 1-11-8, Exterior(2N) 1-11-8 to 2-11-8, Corner(3R) 2-11-8 to 8-11-8, Exterior(2N) 8-11-8 to 9-10-0, Corner(3E) 9-10-0 to 12-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 21, 22, 18, 17, 16 except (jt=lb) 24=197, 14=178, 23=194, 15=180. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss GE07 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130415 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:43:58 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-oLfGCdNejB1jNNQc3TgATp4mIRD8EyofymaTYzyBOd? Scale = 1:71.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 4746 45 4443 42 41 40 39 38 37 3x4 3x6 3x6 5x6 5x6 5x6 3x6 3x4 3x6 3x6 5x6 37-11-0 37-11-0 -0-11-0 0-11-0 10-7-0 10-7-0 27-4-0 16-9-0 37-11-0 10-7-0 38-10-0 0-11-0 1-5-012-0-01-5-012-0-012.00 12 Plate Offsets (X,Y)-- [7:0-1-13,Edge], [11:0-4-8,0-2-0], [20:0-2-8,0-3-4], [26:0-4-8,0-2-0], [30:0-1-13,Edge], [47:0-2-8,0-0-4], [58:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.24 0.11 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.01 (loc) 36 36 37 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 1038 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 *Except* 9-61,8-62,6-63,5-64,4-65,3-66,28-43,29-42,31-41,32-40,33-39,34-38: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 11-26. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 18-52, 17-53, 16-54, 15-55, 14-56, 13-57, 12-59, 10-60, 9-61, 19-51, 21-50, 22-49, 23-48, 24-47, 25-45, 27-44, 28-43 REACTIONS.All bearings 37-11-0. (lb) - Max Horz 67=-239(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 52, 53, 54, 55, 56, 57, 61, 62, 63, 64, 65, 51, 50, 49, 48, 47, 43, 42, 41, 40, 39 except 67=-179(LC 6), 37=-140(LC 7), 66=-175(LC 10), 38=-163(LC 11) Max Grav All reactions 250 lb or less at joint(s) 37, 52, 53, 54, 55, 56, 57, 59, 60, 61, 62, 63, 64, 65, 66, 51, 50, 49, 48, 47, 45, 44, 43, 42, 41, 40, 39, 38 except 67=261(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-9=-144/271, 9-10=-180/332, 10-11=-179/320, 11-12=-146/267, 12-13=-146/267, 13-14=-146/267, 14-15=-146/267, 15-16=-146/267, 16-17=-146/267, 17-18=-146/267, 18-19=-146/267, 19-21=-146/267, 21-22=-146/267, 22-23=-146/267, 23-24=-146/267, 24-25=-146/267, 25-26=-146/267, 26-27=-179/320, 27-28=-180/332, 28-29=-144/271 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 7-7-0, Corner(3R) 7-7-0 to 13-7-8, Exterior(2N) 13-7-8 to 24-3-8, Corner(3R) 24-3-8 to 30-4-0, Exterior(2N) 30-4-0 to 35-10-0, Corner(3E) 35-10-0 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 52, 53, 54, 55, 56, 57, 61, 62, 63, 64, 65, 51, 50, 49, 48, 47, 43, 42, 41, 40, 39 except (jt=lb) 67=179, 37=140, 66=175, 38=163. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Continued on page 2 December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss GE07 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130415 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:43:58 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-oLfGCdNejB1jNNQc3TgATp4mIRD8EyofymaTYzyBOd? NOTES-(13-14) 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss GE08 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130416 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:01 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-CwLOqeQX?6PIEq8BlbEt4RiGlfEfRJY6ejp78HyBOcy Scale = 1:70.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 4544 43 4241 40 39 38 37 36 35 3x4 3x6 3x6 5x6 5x6 5x6 3x4 3x4 3x6 5x6 37-8-0 37-8-0 -0-11-0 0-11-0 10-7-0 10-7-0 27-4-0 16-9-0 37-8-0 10-4-0 1-5-012-0-01-8-012-0-012.00 12 Plate Offsets (X,Y)-- [7:0-1-13,Edge], [11:0-4-8,0-2-0], [20:0-2-8,0-3-4], [26:0-4-8,0-2-0], [35:Edge,0-2-8], [45:0-2-8,0-0-4], [56:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.29 0.12 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 1 1 35 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 1035 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 34-35: 2x3 SPF No.2 OTHERS 2x4 SPF No.2 *Except* 9-59,8-60,6-61,5-62,4-63,3-64,28-41,29-40,30-39,31-38,32-37,33-36: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 11-26. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 18-50, 17-51, 16-52, 15-53, 14-54, 13-55, 12-57, 10-58, 9-59, 19-49, 21-48, 22-47, 23-46, 24-45, 25-43, 27-42, 28-41 REACTIONS.All bearings 37-8-0. (lb) - Max Horz 65=234(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 50, 51, 52, 53, 54, 55, 57, 58, 59, 60, 61, 62, 63, 49, 48, 47, 46, 45, 41, 40, 39, 38, 37 except 65=-232(LC 6), 35=-115(LC 7), 64=-211(LC 7), 36=-138(LC 11) Max Grav All reactions 250 lb or less at joint(s) 35, 50, 51, 52, 53, 54, 55, 57, 58, 59, 60, 61, 62, 63, 49, 48, 47, 46, 45, 43, 42, 41, 40, 39, 38, 37, 36 except 65=310(LC 18), 64=267(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-9=-163/267, 9-10=-200/327, 10-11=-196/316, 11-12=-160/264, 12-13=-160/264, 13-14=-160/264, 14-15=-160/264, 15-16=-160/264, 16-17=-160/264, 17-18=-160/264, 18-19=-160/264, 19-21=-160/264, 21-22=-160/264, 22-23=-160/264, 23-24=-160/264, 24-25=-160/264, 25-26=-160/264, 26-27=-196/316, 27-28=-200/327, 28-29=-163/267 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 7-7-0, Corner(3R) 7-7-0 to 13-7-8, Exterior(2N) 13-7-8 to 24-3-8, Corner(3R) 24-3-8 to 30-4-0, Exterior(2N) 30-4-0 to 34-6-12, Corner(3E) 34-6-12 to 37-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 50, 51, 52, 53, 54, 55, 57, 58, 59, 60, 61, 62, 63, 49, 48, 47, 46, 45, 41, 40, 39, 38, 37 except (jt=lb) 65=232, 35=115, 64=211, 36=138. Continued on page 2 December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss GE08 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130416 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:02 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-g7vm2_Q9mPX9r_jNIIl6dfFRV3auAmoFtNYggkyBOcx NOTES-(13-14) 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss M01 Truss Type MONOPITCH Qty 4 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130417 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:02 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-g7vm2_Q9mPX9r_jNIIl6dfFQQ3Y2Ao7FtNYggkyBOcx Scale = 1:17.3 1 2 3 5 4 2x4 3x6 2x4 5-4-8 5-4-8 -0-11-0 0-11-0 5-4-8 5-4-8 0-9-02-6-80-3-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.36 0.24 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.00 (loc) 4-5 4-5 l/defl >999 >845 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-0, 4=0-1-8 Max Horz 5=55(LC 6) Max Uplift 5=-27(LC 6), 4=-22(LC 10) Max Grav 5=274(LC 1), 4=197(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss M02 Truss Type MONOPITCH Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130418 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:03 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-8JS9FKRnXjf0T8IZs0GL9soaeSuAvFLP61IEDAyBOcw Scale = 1:16.4 1 2 4 3 3x6 2x4 2x4 5-4-8 5-4-8 5-4-8 5-4-8 0-9-02-6-80-3-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.39 0.24 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.00 (loc) 3-4 3-4 l/defl >999 >816 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-3-0, 3=0-1-8 Max Horz 4=43(LC 10) Max Uplift 3=-22(LC 10) Max Grav 4=203(LC 1), 3=203(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss M03 Truss Type MONOPITCH Qty 5 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130419 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:04 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-dV0XSgSPI1nt5ItmQjnai4Ko7sFweinYLh1nlcyBOcv Scale = 1:13.8 1 2 3 5 4 2x4 3x6 2x4 4-4-8 4-4-8 -0-11-0 0-11-0 4-4-8 4-4-8 0-9-02-2-80-3-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.22 0.15 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.00 (loc) 4-5 4-5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-0, 4=0-1-8 Max Horz 5=46(LC 6) Max Uplift 5=-27(LC 6), 4=-18(LC 10) Max Grav 5=235(LC 1), 4=155(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss M04 Truss Type MONOPITCH Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130420 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:04 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-dV0XSgSPI1nt5ItmQjnai4KmusEWeidYLh1nlcyBOcv Scale = 1:17.3 1 2 3 5 4 2x4 3x6 2x4 5-4-8 5-4-8 -0-11-0 0-11-0 5-4-8 5-4-8 0-9-02-6-80-3-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.36 0.24 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.00 (loc) 4-5 4-5 l/defl >999 >845 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-0, 4=0-1-8 Max Horz 5=55(LC 6) Max Uplift 5=-27(LC 6), 4=-22(LC 10) Max Grav 5=274(LC 1), 4=197(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss PB01 Truss Type GABLE Qty 26 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130421 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:05 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-5havg0T13KvkiRSy_RIpFHt_bGc4N6ZhZLnLH3yBOcu Scale = 1:52.0 2 3 4 5 6 10 9 8 1 11 12 7 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 16-9-0 16-9-0 8-4-8 8-4-8 16-9-0 8-4-8 8-4-80-1-40-1-812.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.17 0.09 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 57 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-9-0. (lb) - Max Horz 1=-146(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 6 except 1=-295(LC 17), 7=-214(LC 18), 10=-145(LC 10), 8=-144(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 9 except 2=447(LC 17), 6=419(LC 1), 10=362(LC 17), 8=361(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-193/283 WEBS 3-10=-279/238, 5-8=-278/238 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-2-10 to 3-2-10, Exterior(2N) 3-2-10 to 5-4-8, Corner(3R) 5-4-8 to 11-4-8, Exterior(2N) 11-4-8 to 13-6-6, Corner(3E) 13-6-6 to 16-6-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6 except (jt=lb) 1=295, 7=214, 10=145, 8=144. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss PBE01 Truss Type GABLE Qty 2 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130422 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:08 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-VGG2I1VwMFIIZvBXfZsWswVWoTegaS58FJ??uOyBOcr Scale = 1:54.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 3 4 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 20 19 18 17 16 1 15 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 16-9-0 16-9-0 8-4-8 8-4-8 16-9-0 8-4-8 8-4-80-1-40-1-812.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.04 0.03 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 217 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-9-0. (lb) - Max Horz 1=-146(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 15, 22, 23, 24, 26, 27, 20, 19, 18, 17, 16, 14 except 1=-109(LC 8) Max Grav All reactions 250 lb or less at joint(s) 1, 15, 2, 21, 22, 23, 24, 26, 27, 20, 19, 18, 17, 16, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-2-10 to 3-0-8, Exterior(2N) 3-0-8 to 5-4-8, Corner(3R) 5-4-8 to 11-4-8, Exterior(2N) 11-4-8 to 13-6-6, Corner(3E) 13-6-6 to 16-6-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 22, 23, 24, 26, 27, 20, 19, 18, 17, 16, 14 except (jt=lb) 1=109. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T01 Truss Type COMMON Qty 5 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130423 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:09 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-zTqQWNWY7ZQ9B3mjDHNlP71Z4tnGJoxHUzlYQqyBOcq Scale = 1:61.1 1 2 3 4 5 6 7 11 10 9 8 12 13 4x6 4x6 3x6 3x8 3x4 3x4 3x4 4x6 3x4 10-5-8 10-5-8 20-11-0 10-5-8 -0-11-0 0-11-0 4-5-11 4-5-11 10-5-8 5-11-12 16-5-5 5-11-13 20-11-0 4-5-11 21-10-0 0-11-0 1-3-09-11-91-3-010.00 12 Plate Offsets (X,Y)-- [8:Edge,0-1-12], [11:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.52 0.84 0.69 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.45 0.02 (loc) 8-9 8-9 8 l/defl >999 >548 n/a L/d 240 180 n/a PLATES MT20 Weight: 89 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)11=0-3-8, 8=0-3-8 Max Horz 11=-197(LC 8) Max Grav 11=889(LC 1), 8=889(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-254/40, 3-4=-738/84, 4-5=-738/84, 5-6=-254/40, 2-11=-269/53, 6-8=-269/53 BOT CHORD 9-11=-59/657, 8-9=0/611 WEBS 4-9=-1/516, 3-11=-721/30, 5-8=-721/30 NOTES-(5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 18-10-0, Exterior(2E) 18-10-0 to 21-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T02 Truss Type COMMON Qty 2 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130424 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:09 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-zTqQWNWY7ZQ9B3mjDHNlP71Z4tnFJooHUzlYQqyBOcq Scale = 1:61.1 1 2 3 4 5 6 10 9 8 7 11 12 4x6 3x4 4x6 3x6 3x8 3x4 3x4 3x4 4x6 10-5-8 10-5-8 20-11-0 10-5-8 -0-11-0 0-11-0 4-5-11 4-5-11 10-5-8 5-11-12 16-5-5 5-11-13 20-11-0 4-5-11 1-3-09-11-91-3-010.00 12 Plate Offsets (X,Y)-- [7:Edge,0-1-12], [10:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.52 0.84 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.45 0.02 (loc) 7-8 8-10 7 l/defl >999 >548 n/a L/d 240 180 n/a PLATES MT20 Weight: 88 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 7=0-3-8 Max Horz 10=191(LC 7) Max Grav 10=890(LC 1), 7=823(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-254/40, 3-4=-740/83, 4-5=-741/84, 2-10=-269/53 BOT CHORD 8-10=-69/650, 7-8=0/618 WEBS 4-8=-1/517, 3-10=-724/30, 5-7=-731/45 NOTES-(5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 17-9-4, Exterior(2E) 17-9-4 to 20-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T03 Truss Type SCISSORS Qty 4 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130425 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:10 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-RfOojjWAutY0pDKwm_u?yLajaHBD2MTRjdU6yGyBOcp Scale = 1:30.3 1 2 3 4 5 6 7 8 17 18 19 20 5x8 3x6 5x6 4x6 5x8 3x6 8-4-8 8-4-8 16-9-0 8-4-8 -0-11-0 0-11-0 8-4-8 8-4-8 16-9-0 8-4-8 17-8-0 0-11-0 0-9-03-6-80-9-01-4-34.00 12 2.00 12 Plate Offsets (X,Y)-- [2:0-2-7,Edge], [4:0-3-0,0-2-8], [6:0-4-13,Edge], [8:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.60 0.60 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.24 0.10 (loc) 8-15 8-15 6 l/defl >999 >840 n/a L/d 240 180 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x4 SPF-S Stud 1-6-0, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=-37(LC 11) Max Uplift 2=-35(LC 6), 6=-35(LC 7) Max Grav 2=725(LC 1), 6=725(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1715/229, 4-6=-1715/229 BOT CHORD 2-8=-142/1588, 6-8=-142/1588 WEBS 4-8=0/666 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 5-4-8, Exterior(2R) 5-4-8 to 11-4-8, Interior(1) 11-4-8 to 14-8-0, Exterior(2E) 14-8-0 to 17-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 2, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T04 Truss Type COMMON Qty 3 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130426 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:11 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-vrxAw3XofAgtQMv6KhPEUY7xEheEnsKayHEfViyBOco Scale = 1:40.1 1 2 3 4 7 6 5 8 9 4x6 3x6 3x4 3x4 2x4 3x6 4-8-8 4-8-8 9-5-0 4-8-8 -0-11-0 0-11-0 4-8-8 4-8-8 9-5-0 4-8-8 1-5-06-1-81-5-012.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.42 0.17 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 0.00 (loc) 6 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-0, 5=0-3-0 Max Horz 7=126(LC 7) Max Grav 7=432(LC 1), 5=361(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-322/104, 3-4=-314/110, 2-7=-371/145, 4-5=-297/107 NOTES-(5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 6-3-4, Exterior(2E) 6-3-4 to 9-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T05 Truss Type COMMON Qty 3 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130427 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:12 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-O2VY8PYQQUok2WUIuPwT1mf4p5ynWJrjAxzC19yBOcn Scale = 1:40.5 1 2 3 6 5 4 7 8 3x4 4x6 3x6 3x4 2x4 3x8 MT18HS 4-8-8 4-8-8 8-3-0 3-6-8 4-8-8 4-8-8 8-3-0 3-6-8 1-5-06-1-82-3-80-3-82-7-012.00 12 Plate Offsets (X,Y)-- [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.55 0.28 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.08 0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 31 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-0, 4=0-1-8 Max Horz 6=124(LC 7) Max Uplift 4=-6(LC 10) Max Grav 6=318(LC 1), 4=318(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 5-1-4, Exterior(2E) 5-1-4 to 8-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T06 Truss Type COMMON Qty 2 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130428 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:13 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-sE3xLlZ2Bowbgg3US6RiZzCGHUJXFlYtPbjmZbyBOcm Scale = 1:46.3 1 2 3 4 5 8 7 6 9 10 4x6 3x4 3x4 3x8 6x6 6x6 5-11-8 5-11-8 11-11-0 5-11-8 -0-11-0 0-11-0 5-11-8 5-11-8 11-11-0 5-11-8 12-10-0 0-11-0 1-5-07-4-81-5-012.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [4:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.51 0.24 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.05 0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=-155(LC 8) Max Grav 8=529(LC 1), 6=529(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-429/103, 3-4=-429/103, 2-8=-477/112, 4-6=-477/112 BOT CHORD 7-8=-163/252 NOTES-(5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 2-11-8, Exterior(2R) 2-11-8 to 8-11-8, Interior(1) 8-11-8 to 9-10-0, Exterior(2E) 9-10-0 to 12-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T07 Truss Type PIGGYBACK BASE Qty 11 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130429 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:14 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-KQdJZ5agx52SHqeh?qzx6BlLRuUU_0b0eFSJ51yBOcl Scale = 1:82.5 1 2 34 5 6 7 8 910 11 12 19 18 17 16 15 14 13 20 21 22 23 24 25 3x6 5x10 MT18HS 3x8 5x10 MT18HS 3x6 3x6 3x8 3x6 2x4 3x8 3x8 3x6 3x6 5x6 5x6 3x6 3x6 10-7-0 10-7-0 18-11-8 8-4-8 27-4-0 8-4-8 37-11-0 10-7-0 -0-11-0 0-11-0 5-5-5 5-5-5 10-7-0 5-1-11 18-11-8 8-4-8 27-4-0 8-4-8 32-5-11 5-1-11 37-11-0 5-5-5 38-10-0 0-11-0 1-5-012-0-01-5-012-0-012.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [3:0-2-4,0-1-8], [5:0-8-4,0-1-12], [8:0-8-4,0-1-12], [10:0-2-4,0-1-8], [11:0-3-0,0-1-4], [13:Edge,0-2-4], [19:Edge,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.87 0.84 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.31 -0.63 0.07 (loc) 13-14 18-19 13 l/defl >999 >716 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 199 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-18,10-14,3-19,10-13: 2x3 SPF No.2, 2-19,11-13: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-14 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-12 max.): 5-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-18, 6-18, 6-14, 10-14, 3-19, 10-13 REACTIONS. (size)19=0-3-8, 13=0-3-8 Max Horz 19=-238(LC 8) Max Grav 19=1569(LC 1), 13=1569(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-392/116, 3-5=-1519/113, 5-6=-1002/129, 6-8=-1002/129, 8-10=-1519/113, 10-11=-392/116, 2-19=-420/114, 11-13=-420/113 BOT CHORD 18-19=-112/1045, 16-18=-37/1251, 14-16=-37/1251, 13-14=0/1045 WEBS 5-18=0/635, 6-18=-509/120, 6-16=0/275, 6-14=-509/120, 8-14=0/636, 3-19=-1351/0, 10-13=-1351/0 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-4-1, Exterior(2R) 6-4-1 to 14-9-15, Interior(1) 14-9-15 to 23-1-1, Exterior(2R) 23-1-1 to 31-6-15, Interior(1) 31-6-15 to 35-10-0, Exterior(2E) 35-10-0 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T08 Truss Type PIGGYBACK BASE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130430 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:15 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-odBhmRaJiPAJv_DtZXUAfOHZxIqdjTNAsvCseUyBOck Scale = 1:81.8 12 34 5 6 78 9 10 11 12 13 25 24 23 22 21 18 17 16 15 14 20 19 26 27 28 29 30 3x6 3x6 5x8 3x6 3x6 3x12 3x6 6x16 3x4 4x8 3x6 3x6 4x8 5x10 MT18HS 3x6 3x8 2x4 2x4 2x4 5x12 6x8 10-7-0 10-7-0 18-9-7 8-2-7 22-9-8 4-0-1 27-4-0 4-6-8 37-11-0 10-7-0 -0-11-0 0-11-0 5-5-5 5-5-5 10-7-0 5-1-11 18-9-7 8-2-7 22-9-8 4-0-1 27-4-0 4-6-8 32-5-11 5-1-11 37-11-0 5-5-5 38-10-0 0-11-0 1-5-012-0-01-5-03-0-012-0-012.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [3:0-2-0,0-1-8], [5:0-6-4,0-1-12], [9:0-6-4,0-1-12], [11:0-2-0,0-1-8], [12:0-3-0,0-1-4], [14:Edge,0-2-0], [15:0-2-8,0-2-0], [19:0-5-0,0-2-0], [20:0-7-0,0-3-8], [25:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.69 0.84 0.88 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.34 -0.69 0.15 (loc) 14-15 14-15 14 l/defl >999 >652 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 222 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-24,9-15,6-22,8-17,5-20: 2x4 SPF No.2, 2-25,12-14: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-14 max.): 5-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-24, 5-24, 6-19, 9-15, 11-15, 3-25, 11-14, 6-20, 8-19 JOINTS 1 Brace at Jt(s): 19, 20 REACTIONS. (size)25=0-3-8, 14=0-3-8 Max Horz 25=-238(LC 8) Max Grav 25=1595(LC 1), 14=1602(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-383/123, 3-5=-1560/95, 5-6=-1752/33, 6-8=-1623/32, 8-9=-1625/33, 9-11=-1562/90, 11-12=-395/112, 2-25=-413/118, 12-14=-420/111 BOT CHORD 24-25=-98/1069, 14-15=0/1074, 19-20=-20/1756 WEBS 6-19=-356/103, 9-15=-455/121, 3-25=-1400/0, 11-14=-1395/0, 20-24=-43/1094, 15-19=0/1212, 9-19=-56/1320, 5-20=0/1068 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-4-1, Exterior(2R) 6-4-1 to 14-9-15, Interior(1) 14-9-15 to 22-11-4, Exterior(2R) 22-11-4 to 31-6-15, Interior(1) 31-6-15 to 35-10-0, Exterior(2E) 35-10-0 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T08A Truss Type PIGGYBACK BASE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130431 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:17 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-k?JRB6cZE0Q18HNGhyWekpNvn6XKBNGSKDhziMyBOci Scale = 1:93.2 1 2 34 5 6 7 8 9 10 11 12 13 24 23 22 21 20 17 16 15 14 19 18 25 26 27 28 29 3x6 5x10 MT18HS 3x6 5x8 3x6 3x8 3x4 3x6 5x12 3x4 4x8 3x6 3x6 5x6 5x6 3x6 2x4 3x8 2x4 2x4 3x4 5x12 10-7-0 10-7-0 18-9-7 8-2-7 22-9-8 4-0-1 27-4-0 4-6-8 37-11-0 10-7-0 -0-11-0 0-11-0 5-5-5 5-5-5 10-7-0 5-1-11 18-9-7 8-2-7 22-9-8 4-0-1 27-4-0 4-6-8 32-5-11 5-1-11 37-11-0 5-5-5 38-10-0 0-11-0 1-5-012-0-01-5-03-0-012-0-012.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [3:0-2-4,0-1-8], [5:0-8-4,0-1-12], [9:0-6-4,0-1-12], [11:0-2-4,0-1-8], [12:0-3-0,0-1-4], [14:Edge,0-2-4], [15:0-2-8,0-2-0], [18:0-2-8,0-2-12], [19:0-6-8,0-3-12], [24:Edge,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.67 0.83 0.86 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.33 -0.66 0.15 (loc) 14-15 14-15 14 l/defl >999 >682 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 219 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-23,9-15,6-20,8-17,5-19: 2x4 SPF No.2, 2-24,12-14: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-5-1 max.): 5-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-23, 5-23, 6-18, 9-15, 11-15, 3-24, 11-14, 6-20, 8-17 REACTIONS. (size)24=0-3-8, 14=0-3-8 Max Horz 24=-238(LC 8) Max Grav 24=1568(LC 1), 14=1567(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-400/117, 3-5=-1513/115, 5-6=-1692/69, 6-8=-1555/73, 8-9=-1557/74, 9-11=-1519/116, 11-12=-389/116, 2-24=-426/115, 12-14=-416/113 BOT CHORD 23-24=-112/1042, 22-23=-52/988, 14-15=0/1046, 18-19=-56/1697 WEBS 6-18=-377/92, 9-15=-412/147, 3-24=-1337/0, 11-14=-1358/0, 19-22=-57/1066, 15-18=0/1181, 9-18=-105/1238, 5-19=-3/1031 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-4-1, Exterior(2R) 6-4-1 to 14-9-15, Interior(1) 14-9-15 to 22-11-4, Exterior(2R) 22-11-4 to 31-6-15, Interior(1) 31-6-15 to 35-10-0, Exterior(2E) 35-10-0 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T08B Truss Type PIGGYBACK BASE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130432 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:18 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-CCsqOSdB?KYumRySEg1tG1v0rVs3wpZcZtQXEoyBOch Scale = 1:88.3 1 2 34 5 6 7 8 910 11 12 23 22 21 17 16 15 14 13 20 19 18 24 25 26 27 28 29 3x6 5x10 MT18HS 3x8 5x10 MT18HS 3x6 2x4 2x4 2x4 5x12 3x8 4x6 3x8 5x10 MT18HS 3x6 3x8 5x8 6x10 4x6 2x4 5x12 10-7-0 10-7-0 13-0-0 2-5-0 14-6-15 1-6-15 18-11-8 4-4-9 27-4-0 8-4-8 37-11-0 10-7-0 -0-11-0 0-11-0 5-5-5 5-5-5 10-7-0 5-1-11 13-0-0 2-5-0 18-11-8 5-11-8 27-4-0 8-4-8 32-5-11 5-1-11 37-11-0 5-5-5 38-10-0 0-11-0 1-5-012-0-01-5-03-0-012-0-012.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-0], [5:0-8-4,0-1-12], [8:0-8-4,0-1-12], [10:0-2-5,0-2-1], [11:0-3-4,0-1-8], [13:Edge,0-2-0], [18:0-2-0,0-0-0], [20:0-3-12,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.90 0.86 0.92 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.60 -1.27 0.20 (loc) 17 17 13 l/defl >750 >355 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 225 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 10-14,14-18,19-21,3-20: 2x3 SPF No.2 2-23,11-13,10-13,3-23: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-13 oc purlins, except end verticals, and 2-0-0 oc purlins (2-2-0 max.): 5-8. BOT CHORD Structural wood sheathing directly applied or 9-8-4 oc bracing. Except: 10-0-0 oc bracing: 18-19 WEBS 1 Row at midpt 6-20, 10-14, 10-13, 3-23 2 Rows at 1/3 pts 6-14 JOINTS 1 Brace at Jt(s): 18, 19, 20 REACTIONS. (size)13=0-3-8, 23=0-3-8 Max Horz 23=-238(LC 8) Max Grav 13=1606(LC 1), 23=1616(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-418/116, 3-5=-2062/0, 5-6=-1415/31, 6-8=-1041/109, 8-10=-1560/86, 10-11=-406/107, 2-23=-442/113, 11-13=-430/107 BOT CHORD 13-14=0/1073, 19-20=0/1776, 18-19=0/1776 WEBS 20-22=0/470, 5-20=0/1004, 6-20=-615/105, 16-18=0/345, 6-18=0/965, 6-14=-1286/81, 8-14=0/694, 10-13=-1380/0, 14-18=-0/1853, 3-23=-1880/0, 20-23=-128/1428 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-4-1, Exterior(2R) 6-4-1 to 14-9-15, Interior(1) 14-9-15 to 23-1-1, Exterior(2R) 23-1-1 to 31-6-15, Interior(1) 31-6-15 to 35-10-0, Exterior(2E) 35-10-0 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T09 Truss Type PIGGYBACK BASE Qty 6 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130433 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:19 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-gOQCcodpmegkObWeoNY6pESCAvChfHYlnXA4nFyBOcg Scale = 1:85.2 1 2 34 5 6 7 8 9 10 17 16 15 14 13 12 11 18 19 20 21 22 23 3x6 5x10 MT18HS 3x8 5x10 MT18HS 3x4 3x6 3x8 3x6 2x4 3x8 3x8 3x6 3x6 5x6 4x8 3x6 10-7-0 10-7-0 18-11-8 8-4-8 27-4-0 8-4-8 37-8-0 10-4-0 -0-11-0 0-11-0 5-5-5 5-5-5 10-7-0 5-1-11 18-11-8 8-4-8 27-4-0 8-4-8 32-5-11 5-1-11 37-8-0 5-2-5 1-5-012-0-01-8-012-0-012.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [3:0-2-4,0-1-8], [5:0-8-4,0-1-12], [8:0-8-4,0-1-12], [9:0-1-12,0-1-8], [10:0-2-0,0-1-4], [11:Edge,0-1-8], [17:Edge,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.87 0.83 0.87 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.31 -0.63 0.07 (loc) 16-17 16-17 11 l/defl >999 >710 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 197 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,9-12,3-17,9-11: 2x3 SPF No.2, 2-17,10-11: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-11 oc purlins, except end verticals, and 2-0-0 oc purlins (4-4-1 max.): 5-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-16, 6-16, 6-12, 9-12, 3-17, 9-11 REACTIONS. (size)17=0-3-8, 11=Mechanical Max Horz 17=234(LC 7) Max Grav 17=1560(LC 1), 11=1494(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-392/116, 3-5=-1507/114, 5-6=-994/129, 6-8=-981/130, 8-9=-1490/115, 9-10=-285/74, 2-17=-419/114, 10-11=-273/63 BOT CHORD 16-17=-123/1037, 14-16=-49/1236, 12-14=-49/1236, 11-12=0/1001 WEBS 5-16=0/629, 6-16=-498/120, 6-14=0/277, 6-12=-519/118, 8-12=0/619, 3-17=-1340/0, 9-11=-1431/0 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-4-1, Exterior(2R) 6-4-1 to 14-9-15, Interior(1) 14-9-15 to 23-1-1, Exterior(2R) 23-1-1 to 31-6-15, Interior(1) 31-6-15 to 34-6-4, Exterior(2E) 34-6-4 to 37-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss T10 Truss Type PIGGYBACK BASE Qty 6 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130434 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:20 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-9a_ap8eRXxob0l5rM43LMS?NsJVJOkbv0BvdJhyBOcf Scale = 1:82.6 1 2 34 5 6 7 8 910 11 17 16 15 14 13 12 18 19 20 21 22 23 3x6 5x10 MT18HS 3x8 5x8 3x6 3x6 3x8 3x6 3x8 2x4 3x8 2x4 3x6 5x6 4x8 3x8 MT18HS 10-7-0 10-7-0 18-11-8 8-4-8 27-4-0 8-4-8 38-11-0 11-7-0 -0-11-0 0-11-0 5-5-5 5-5-5 10-7-0 5-1-11 18-11-8 8-4-8 27-4-0 8-4-8 32-5-11 5-1-11 38-11-0 6-5-5 1-5-012-0-00-5-012-0-012.00 12 Plate Offsets (X,Y)-- [2:0-3-4,0-1-8], [3:0-2-0,0-1-8], [5:0-8-4,0-1-12], [8:0-6-4,0-1-12], [11:0-4-9,0-2-8], [17:Edge,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.87 1.00 0.88 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.42 -0.91 0.08 (loc) 11-12 11-12 11 l/defl >999 >512 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 193 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,10-12,3-17: 2x3 SPF No.2, 2-17: 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-0-3 max.): 5-8. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 3-16, 6-16, 6-12, 10-12, 3-17 REACTIONS. (size)17=0-3-8, 11=0-3-8 Max Horz 17=-227(LC 8) Max Grav 17=1610(LC 1), 11=1544(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-394/116, 3-5=-1571/112, 5-6=-1039/128, 6-8=-1101/127, 8-10=-1672/111, 10-11=-1888/53, 2-17=-422/113 BOT CHORD 16-17=-105/1078, 14-16=-26/1316, 12-14=-26/1316, 11-12=0/1260 WEBS 5-16=0/663, 6-16=-554/116, 6-14=0/264, 6-12=-466/129, 8-12=0/746, 10-12=-303/196, 3-17=-1401/0 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-4-1, Exterior(2R) 6-4-1 to 14-9-15, Interior(1) 14-9-15 to 23-1-1, Exterior(2R) 23-1-1 to 31-6-15, Interior(1) 31-6-15 to 35-9-4, Exterior(2E) 35-9-4 to 38-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss TG02 Truss Type COMMON GIRDER Qty 1 Ply 2 24 Estates at Towne Medow Job Reference (optional) I49130435 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:21 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-dmYy1Uf3IFwSdvg1wobaufXaYjz17Ap2FrfBr7yBOce Scale = 1:49.5 1 2 3 7 6 5 4891011 5x6 7x16 MT18HS 5x6 3x4 3x4 10x10 10x10 3-1-8 3-1-8 8-9-8 5-8-0 11-11-0 3-1-8 3-1-8 3-1-8 5-11-8 2-10-0 8-9-8 2-10-0 11-11-0 3-1-8 1-5-07-4-81-5-012.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-0], [3:Edge,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.75 0.46 0.95 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.16 0.00 (loc) 5-6 5-6 4 l/defl >999 >875 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 138 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-8, 4=0-3-8 Max Horz 7=-134(LC 4) Max Grav 7=4962(LC 1), 4=4814(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-4419/0, 2-3=-4694/0, 1-7=-4286/0, 3-4=-4555/0 BOT CHORD 6-7=-134/276, 5-6=0/1930 WEBS 2-5=0/3473, 2-6=0/2959, 1-6=0/3066, 3-5=0/3279 NOTES-(9-10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1475 lb down at 1-0-12, 1474 lb down at 3-0-12, 1474 lb down at 5-0-12, 1474 lb down at 7-0-12, and 1474 lb down at 9-0-12, and 1474 lb down at 10-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-7=-20 Continued on page 2 December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss TG02 Truss Type COMMON GIRDER Qty 1 Ply 2 24 Estates at Towne Medow Job Reference (optional) I49130435 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:21 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-dmYy1Uf3IFwSdvg1wobaufXaYjz17Ap2FrfBr7yBOce LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 5=-1474(B) 6=-1474(B) 8=-1475(B) 9=-1474(B) 10=-1474(B) 11=-1474(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss V02 Truss Type Valley Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130436 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:22 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-5z6KEqgi3Z2JF3FDTV6pRt4uL7OfsnaCTVOkNayBOcd Scale = 1:68.8 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 21-4-12 21-4-12 10-8-6 10-8-6 21-4-12 10-8-6 0-0-410-8-60-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.17 0.18 0.28 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-11: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 21-4-12. (lb) - Max Horz 1=-185(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 7 except 12=-144(LC 10), 13=-110(LC 10), 9=-143(LC 11), 8=-110(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=257(LC 20), 12=368(LC 17), 13=297(LC 17), 9=368(LC 18), 8=297(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-287/193, 5-9=-286/193 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 7-8-6, Exterior(2R) 7-8-6 to 13-8-6, Interior(1) 13-8-6 to 18-0-8, Exterior(2E) 18-0-8 to 21-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7 except (jt=lb) 12=144, 13=110, 9=143, 8=110. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss V03 Truss Type VALLEY Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130437 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:23 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-Z9gjSAhKqsAAtCqP1Dd2z4d1JWj?bGxLi98Iw0yBOcc Scale = 1:56.0 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 17-4-8 17-4-8 17-4-12 0-0-4 8-8-6 8-8-6 17-4-12 8-8-6 0-0-48-8-60-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.22 0.23 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 59 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-8: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.All bearings 17-4-4. (lb) - Max Horz 1=-149(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-165(LC 10), 6=-164(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=427(LC 17), 6=426(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-315/205, 4-6=-311/203 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 5-8-6, Exterior(2R) 5-8-6 to 11-8-6, Interior(1) 11-8-6 to 14-0-8, Exterior(2E) 14-0-8 to 17-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=165, 6=164. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss V04 Truss Type Valley Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130438 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:24 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-1LE5fWhybAJ1UMPcbw8HWI9Baw5NKj9UxotrSSyBOcb Scale = 1:41.9 1 2 3 4 5 8 7 6 9 10 11 12 3x4 5x6 3x4 2x4 2x4 2x4 2x4 2x4 13-4-8 13-4-8 13-4-12 0-0-4 6-8-6 6-8-6 13-4-12 6-8-6 0-0-46-8-60-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.31 0.10 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-4-4. (lb) - Max Horz 1=-115(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-132(LC 10), 6=-132(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=326(LC 17), 6=326(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-254/179, 4-6=-253/179 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-14 to 3-3-14, Interior(1) 3-3-14 to 3-8-6, Exterior(2R) 3-8-6 to 9-8-6, Interior(1) 9-8-6 to 10-0-15, Exterior(2E) 10-0-15 to 13-0-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=132, 6=132. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss V05 Truss Type VALLEY Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130439 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:25 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-VYoTsriaMURu6W_o9efW3ViKRKN?3AEeASdO_uyBOca Scale = 1:31.0 1 2 3 44x6 3x6 4x6 2x4 9-4-8 9-4-8 9-4-12 0-0-4 4-8-6 4-8-6 9-4-12 4-8-6 0-0-44-8-60-0-412.00 12 Plate Offsets (X,Y)-- [1:0-1-14,0-1-12], [3:0-1-5,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.43 0.33 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 WEDGE Left: 2x6 SP No.2 , Right: 2x6 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-4-4, 3=9-4-4, 4=9-4-4 Max Horz 1=-80(LC 6) Max Uplift 1=-8(LC 11), 3=-8(LC 11) Max Grav 1=191(LC 1), 3=191(LC 1), 4=330(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-0 to 3-3-0, Exterior(2R) 3-3-0 to 6-1-12, Exterior(2E) 6-1-12 to 9-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss V06 Truss Type Valley Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130440 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:26 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-zkLr4BjC7nZlkgZ_iLAlbjFZykhXoetnO6MyXLyBOcZ Scale = 1:18.9 1 2 3 3x4 3x4 3x4 0-0-4 0-0-4 5-4-12 5-4-8 2-8-6 2-8-6 5-4-12 2-8-6 0-0-42-8-60-0-412.00 12 Plate Offsets (X,Y)-- [1:0-3-3,Edge], [2:0-0-0,0-0-1], [3:0-0-15,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.19 0.50 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-12 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-4-4, 3=5-4-4 Max Horz 1=44(LC 7) Max Grav 1=196(LC 1), 3=196(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss V08 Truss Type Valley Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130441 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:26 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-zkLr4BjC7nZlkgZ_iLAlbjFUTkk9odCnO6MyXLyBOcZ Scale = 1:32.9 1 2 3 4 5 6 3x8 3x6 3x8 2x4 0-0-4 0-0-4 10-4-12 10-4-8 5-2-6 5-2-6 10-4-12 5-2-6 0-0-45-2-60-0-412.00 12 Plate Offsets (X,Y)-- [1:0-5-13,Edge], [2:0-3-8,0-1-8], [3:0-3-9,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.48 0.27 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=10-4-4, 3=10-4-4, 4=10-4-4 Max Horz 1=-88(LC 6) Max Uplift 1=-3(LC 11), 3=-3(LC 11) Max Grav 1=204(LC 1), 3=204(LC 1), 4=372(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-14 to 3-3-14, Exterior(2R) 3-3-14 to 7-0-15, Exterior(2E) 7-0-15 to 10-0-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss V09 Truss Type Valley Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130442 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:27 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-RwvDHXkqu5hcLq8BG2i_8wnkp86rX57xdm6V3nyBOcY Scale = 1:8.2 1 2 3 3x4 3x4 3x4 3-3-3 3-3-3 0-0-41-1-14.00 12 Plate Offsets (X,Y)-- [3:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.18 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-3 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-2-7, 3=3-2-7 Max Horz 1=26(LC 7) Max Uplift 1=-3(LC 6), 3=-7(LC 10) Max Grav 1=99(LC 1), 3=99(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss VGE01 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130443 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:29 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-OJ1_iDl5PixKb7HZOTkSDLt51xpJ?_yD54bc7gyBOcW Scale = 1:91.5 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2021 39 38 37 36 35 34 3332 31 30 29 28 27 26 25 24 23 22 45 43 40 44 42 41 47 4648 49 52 50 53 51 54 554x6 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 3x6 3x8 3x6 3x8 3x6 3x6 2x4 2x4 2x4 2x4 2-1-0 2-1-07-6-02-0-025-4-12 25-4-12 12-8-6 12-8-6 25-4-12 12-8-6 0-0-412-8-60-0-412.00 12 Plate Offsets (X,Y)-- [6:0-3-0,Edge], [11:0-2-0,0-1-4], [16:0-3-0,Edge], [42:0-3-0,0-0-4], [44:0-3-0,0-0-4], [46:0-3-0,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.07 0.05 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 21 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 482 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 11-30: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-34, 14-27 JOINTS 1 Brace at Jt(s): 40, 41, 42, 43, 44, 45, 46, 47 REACTIONS.All bearings 25-4-12. (lb) - Max Horz 1=-222(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 32, 34, 35, 36, 37, 38, 39, 28, 27, 26, 25, 24, 23, 22, 21 Max Grav All reactions 250 lb or less at joint(s) 1, 30, 32, 34, 35, 36, 37, 38, 39, 28, 27, 26, 25, 24, 23, 22, 21, 31, 29 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-300/183, 20-21=-269/137 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-14 to 3-4-6, Interior(1) 3-4-6 to 9-8-6, Exterior(2R) 9-8-6 to 15-8-6, Interior(1) 15-8-6 to 22-0-6, Exterior(2E) 22-0-6 to 25-0-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 32, 34, 35, 36, 37, 38, 39, 28, 27, 26, 25, 24, 23, 22, 21. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 24_ESTATES_AT_TOWNE_~W Truss VGE07 Truss Type GABLE Qty 1 Ply 1 24 Estates at Towne Medow Job Reference (optional) I49130444 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Dec 7 09:44:30 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Cl?7YvwYsBnLnjSQfa95ktzam7n-sVbMwZmjA03BCHsmxBFhmZPHQL9skRCNJkK9g6yBOcV Scale = 1:45.9 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 22 23 3x4 4x6 3x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-4-12 14-4-12 7-2-6 7-2-6 14-4-12 7-2-6 0-0-47-2-60-0-412.00 12 Plate Offsets (X,Y)-- [20:0-3-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.03 0.03 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 169 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-4-12. (lb) - Max Horz 1=-123(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 17, 18, 19, 21, 15, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11, 16, 17, 18, 19, 21, 15, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-4 to 3-2-6, Interior(1) 3-2-6 to 4-2-6, Exterior(2R) 4-2-6 to 10-2-6, Interior(1) 10-2-6 to 11-0-9, Exterior(2E) 11-0-9 to 14-0-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 17, 18, 19, 21, 15, 14, 13, 12. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 8,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths