Loading...
HomeMy WebLinkAboutA000.31900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2021 Zach Bittner08/04/2014 Right Rockwall 2054.300.00.CPM Lot 22 11/23/2021 PLOTTED: December 2, 2021 / Brandon Hogan / 2054-ROCKWALL-IN-WDSH-EL-HR3T-02.DWG A3-HR3T-02 3SB.1Heartland 3T-023 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleSCALE:FRONT ELEVATION1/4" = 1'-0"- 1210 1210 ROOF SHINGLES, PER SPEC 6" RAKE BOARD, PER SPECFRIEZE, PER SPEC 10" FRIEZE, PER SPECBRICK ROWLOCK, \PPER SPECBRICK VENEER, \PPER SPEC 6" CORNER BOARD, PER SPEC HORIZONTAL SIDING, PER SPEC 8" TRIM, PER SPEC BRICK SOLDIER, PER SPEC 16" SHUTTER, \PPER SPEC 6" FASCIA BOARD, PER SPEC BRICK ROWLOCK, \PPER SPEC CL-02AD 2.1SIMILAR 16" SHUTTER, PER SPEC FYPON BRACKET #BKT14X16X4 OR APPROVED EQUAL METAL ROOF, \PPER SPEC BOARD & BATTEN SIDING, PER SPEC RAIL, PER SPEC 2040 FX BLACKED OUT WINDOW 2030 FX BLACKED OUT WINDOW 4" TRIM, PER SPEC 6" TRIM, PER SPEC \A1;9'-1{\H0.75x;\S1#8;}"\A1;8'-2{\H0.75x;\S7#8;}" \A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}" TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATEWINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR WINDOW HEAD HGT. \A1;2'-2{\H0.75x;\S7#8;}" \A1;10'-6" SCALE:REAR ELEVATION1/8" = 1'-0"- 1210 12101210 MASONRY WAINSCOT \A1;9'-1{\H0.75x;\S1#8;}" \A1;8'-1{\H0.75x;\S1#8;}" \A1;8'-2{\H0.75x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;7'-2{\H0.75x;\S7#8;}"\A1;HDR. HGT. TYP. TOP OF FOUNDATIONTOP OF FLOOR TOP OF PLATETOP OF FLOOR TOP OF PLATE ROOF SHINGLES, PER SPEC HORIZONTAL SIDING, \PPER SPEC 6" FASCIA BOARD, PER SPEC SCALE:LEFT ELEVATION1/8" = 1'-0"- 128128 123.5124 ROOF SHINGLES, PER SPEC BRICK VENEER, PER SPEC HORIZONTAL SIDING, PER SPEC TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATEWINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR WINDOW HEAD HGT. SCALE:RIGHT ELEVATION1/8" = 1'-0"- 128 124 \pxql;8" TRIM, PER SPEC.\pxql;6" TRIM, PER SPEC. MASONRY WAINSCOT \A1;9'-1{\H0.75x;\S1#8;}"\A1;8'-2{\H0.75x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}"\A1;HDR. HGT. TYP. SCALE:PORCH SECTIONS & DETAILS1/4" = 1'-0"- SCALE:ELEVATION 11/4" = 1'-0"- \A1;2'-2{\H0.750000x;\S7#8;}"\A1;3'-2{\H0.7x;\S7#8;\H1.4286x;" @ \POPT. 10' PLT} SCALE:ROOF PLAN1/8" = 1'-0"- ROOF AREASQ. FT."C"217 \A1;4'-0" 10:12 8:12 10:12 8:12 8:12 8:12 10:12 10:1210:1210:12 ROOF AREASQ. FT."A"2486 PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION \A1;1'-0"\PTYP. 10:12 \A1;8'-0" \A1;6'-0"\A1;8'-0" \A1;10'-0" 10:12 10:128:12 3.5:12 MIN. 215 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D" 4:12 4:12 ELEVATION HR3T-IN1 ROOF AREA "C"SQ FTG 217 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.29 0.36 0.42 43.26 1 0 AT EAVE 0.43 0.36 0.56 56.74 0 8.00 TOTAL (MIN)0.72 0.72 0.98 100.00 3 HIGH - RIDGE VENT 0.29 0.36 0.50 47.37 0 0 4.00 AT EAVE 0.43 0.36 0.56 52.63 0 8.00 TOTAL (MIN)0.72 0.72 1.06 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ELEVATION HR3T-IN1 ROOF AREA "A"SQ FTG 2486 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.31 4.14 3.39 43.65 8 0 AT EAVE 4.97 4.14 4.38 56.35 0 63.00 TOTAL (MIN)8.29 8.29 7.76 100.00 3 HIGH - RIDGE VENT 3.31 4.14 4.00 47.76 0 0 32.00 AT EAVE 4.97 4.14 4.38 52.24 0 63.00 TOTAL (MIN)8.29 8.29 8.38 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE Grids 4 sides are optional Column is Field Built 01/04/22