Loading...
HomeMy WebLinkAboutS502.0Higharc, Inc. is not an architectural firm nor are the artistic representations contained herein intended to be construed as ready- to-use architectural plans, construction documents, drawings, renderings, or any other similar or related documents. All drawings are artist’s representations only and solely intended to reflect design intent derived exclusively from the home building plans and associated information, data, and specifications provided by Epcon -Indianapolis. Higharc, Inc. is not responsible, nor may it be held liable for any errors or omissions contained herein or resulting from its usage. Any usage of the representations should be reviewed by local professionals to ensure conformance with local and state codes and be field verified prior to the start of any construction. ISSUE DESCRIPTION DATE 01 BUILDER SET DRAWING TITLE DETAILS SHEET NUMBER A-403 NOT FOR CONSTRUCTION © 2021 HIGHARC, INC ALL RIGHTS ARE RESERVED IN THIS INFORMATION AND ALL RELATED ILLUSTRATIONS, PLANS, BLUEPRINTS, SKETCHES, DRAWINGS OR OTHER TANGIBLE, EXPRESSIONS THEREOF, WHICH ARE THE PROPERTY OF EPCON COMMUNITIES FRANCHISING, INC. 500 STONEHENGE PARKWAY, DUBLIN, OH, 43017, TELEPHONE 614.652.3527. NO ONE MAY BUILD, LICENSE, TRANSFER, REPRODUCE OR DUPLICATE THIS WORK IN ANY WAY WITHOUT THE WRITTEN AUTHORIZATION OF EPCON COMMUNITIES FRANCHISING, INC. THESE DRAWINGS SHALL BE USED IN CONFORMANCE WITH ALL LOCAL BUILDING, MECHANICAL, PLUMBING AND ELECTRICAL CODES AND SHALL MEET THE REQUIREMENTS OF THE HEALTH DEPARTMENT, FIRE MARSHALL, AMERICANS WITH DISABILITIES ACT, ACCESSIBILITY GUIDELINES (ADAAG), THE FAIR HOUSING ACT ACCESSIBILITY GUIDELINES (FHAAG), AND SHALL BE CONSTRUCTED IN CONFORMANCE WITH STATE AND LOCAL ENERGY REQUIREMENTS. 500 Stonehenge Pkwy. Dublin, OH 43017 (614)761-1010 (614)761-1155 fax GARAGE LIVING AREA STAIRS WEATHER LIPSEE STRUCTURALSEE STRUCTURAL 1/4" THICK PRE- FORMED EXPANSION JOINT MATERIAL INSULATED OVERHEAD GARAGE DOOR RECESSEDCONCRETE FOOTING - SEE STRUCTURAL PLANS 1"SEE STRUCTURALVARIES9'-1 1/8"1'-2"SLOPE TO GARAGE DOOR VARIES - (FLUSH W/ FIRSTFLOOR AT BACK WALL, 6"AT GARAGE DOOR)CONCRETE SLAB - SEE STRUCTURAL PLANS CONTINUOUS 2 X 6 FRAMING 2 X 10 X 48" DOOR OPERATOR MOUNTING BLOCK @ CENTER OF DOOR OPENING 1/2" DRYWALL HEADER -SEE STRUCTURAL PLANS Z CAP FLASHING CULTURED STONE VENEER 5/4 X 8 FRIEZE TRIM VENTED ALUMINUM SOFFIT PANEL 5" ALUMINUM OGEE GUTTER ON ALUMINUM CLAD 2 X 6 SUB FASCIA ARCHITECTURAL SHINGLES ROOF SHEATHING INSULATION STOP 2 X 4 WOOD ROOF TRUSSES AT 24" O.C. DORMER BEYOND CONFIGURATION MAY VARY -SEE ELEVATIONS AIR BARRIER FIBERGLASS BATT INSULATION WITH VAPOR BARRIER FIBERGLASS BATT INSULATION WITH IN FRONT OF BEAM WOOD BASE - TYPICAL 2 X 4 WOOD STUDS @ 16" O.C.8'-1 1/8"8" CONDENSED "CATHEDRAL TYPE" BATT FIBERGLASS INSULATION 12 10 RIDGE VENT 12 10 5/8" DRYWALL CEILING WOOD BASE - TYPICAL SUB- FLOORING BATT FIBERGLASS INSULATION 2 X 4 WOOD STUD WALL BETWEEN TRUSSES FOR BEARING OF RAFTERS RAFTERS - SEE STRUCTURAL PLANS 2 X WOOD ROOF TRUSSES - SEE STRUCTURAL SHEETS FLASHING ARCHITECTURAL SHINGLES ROOF SHEATHING 2 X WOOD ROOF TRUSSES GIRDER TRUSS LOCATION SEE STRUCTURAL SHEETS 5/8" DRYWALL CEILING 3'-0"2'-10"HALF WALL @ 36" A.F.F. WITH 1 X 6 HARDWOOD CAP BLOWN INSULATION 9'-1 1/8"3'-2 3/4"WOOD HANDRAIL - 34" ABOVE STAIR TREADS HARD BOARD TREADS AND RISERS CONCRETE SLAB - SEE STRUCTURAL PLANS CONCRETE FOOTING - SEE STRUCTURAL PLANS CONCRETE STEM WALL -SEE STRUCTURAL PLANS 1/2" DRYWALL GARAGE FLOORFIRST FLOOR FIBERGLASS BATT INSULATION 2 X 4 WOOD STUDS @ 16" O.C. SUB-FLOORING - SEE STRUCTURAL PLANS FIBERGLASS BATT TYPE INSULATION 5/8" TYPE "X" DRYWALL CEILING BRICK SOLDIER COURSE - EXTEND 1/2" OUT FROM FACE OF STONE 1/2" = 1'-0"1 TYPICAL WALL SECTION BONUS PROJECT MODEL HOME ELEV: Elevation A 12/7/2021 01/06/22