Loading...
HomeMy WebLinkAboutTrusses - SEALED 1904864-80T Crtyrd of Carmel Lot 1Initials:Job Name:Model:Tag:EPCON COMMUNITIESD4 Elev A with (SP or SR), EP, and BRCrtyrd on RIVERSIDE 75JGSNOTES:07/30/19Today's Date:DIR:BUILD & HOLD :SHIPPING DATE :P.O. NUMBER :FILE ID# 1904864-80T Thank you for choosing CONTRACT BUILDING COMPONENTS 14540 INDUSTRIAL PKWY. MARYSVILLE, OH 43040 Any Questions, please call (937) 644-0739QTY SPANLUMBERTOP BOTOVERHANGLEFT RIGHTCANTILEVERLEFT RIGHTPITCHTOP BOTIDFT-IN-16PROFILERoof TrussesPLYINFORMATION BY EACH TRUSSTOTALPRICEPRICEUNITC-423 1110.00 0.0002-08-14 00-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 9.06Ship Ht = 1 - 8 - 0GT-406 1 8.00 0.0035-00-0800-10-0800-00-00 00-00-002 X 4 2 X 6 2BRDFT =Weight = 330.80Ship Ht =4 -11 -13GT-419B 1 8.00 0.0041-10-0001-06-0300-00-00 00-00-002 X 6 2 X 10 3BRDFT =Weight = 1152.90Ship Ht =12 - 6 - 2GT-420B 1 3.71 0.0006-09-1501-00-1000-00-00 00-00-002 X 4 2 X 6 2BRDFT =Weight = 49.40Ship Ht = 2 - 7 -13GT-423 1 8.00 0.0015-03-0000-10-08 00-10-0800-00-00 00-00-002 X 6 2 X 10 2BRDFT =Weight = 192.38Ship Ht = 5 - 7 - 8GT-426 1 8.00 0.0015-03-0000-10-08 00-10-0800-00-00 00-00-002 X 4 2 X 6BRDFT =Weight = 60.95Ship Ht = 3 - 5 -13GT-428 1 8.00 0.0021-05-0001-01-12 01-00-1200-00-00 00-00-002 X 4 2 X 10 3BRDFT =Weight = 425.70Ship Ht = 7 - 8 - 2GT-430 110.00 0.0022-08-0800-10-0800-00-00 00-00-002 X 2 X 4 4BRDFT =Weight = 864.20Ship Ht =12 - 3 -12GT-430A 110.00 0.0022-08-0800-10-0800-00-00 00-00-002 X 2 X 4 4BRDFT =Weight = 879.44Ship Ht =12 - 3 -12GT-431 110.00 0.0031-00-04 00-00-00 00-00-002 X 6 2 X 8 2BRDFT =Weight = 421.74Ship Ht =12 - 3 -12HT-300A 1 5.66 0.0009-03-1001-02-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 32.54Ship Ht = 4 -11 - 2HT-438 2 5.66 0.0006-01-0701-05-1100-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 21.15Ship Ht = 3 - 5 - 2T-401 2 8.00 0.0002-06-1500-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 8.51Ship Ht = 2 - 3 - 2T-403 5 8.00 0.0006-08-0000-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 22.48Ship Ht =4 -11 -13T-404 10 8.00 0.0006-08-0000-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 21.00Ship Ht =4 -11 -13T-405 2 8.00 0.0004-06-1500-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 14.62Ship Ht = 3 - 7 - 2T-407 1 8.00 0.0035-00-0800-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 152.72Ship Ht = 6 - 3 -13T-408 1 8.00 0.0035-00-0800-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 168.61Ship Ht = 7 - 7 -13T-409 1 8.00 0.0035-00-0800-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 155.33Ship Ht =8 -11 -13T-415B 3 8.00 0.0035-00-0800-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 156.63Ship Ht =12 - 6 - 2T-421B 1 3.71 0.0005-00-1501-02-0200-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 14.26Ship Ht = 2 - 1 - 5T-422B 1 3.71 0.0003-00-1501-02-0200-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 9.09Ship Ht = 1 - 5 -14 1PAGE Initials:Job Name:Model:Tag:EPCON COMMUNITIESD4 Elev A with (SP or SR), EP, and BRCrtyrd on RIVERSIDE 75JGSNOTES:07/30/19Today's Date:DIR:BUILD & HOLD :SHIPPING DATE :P.O. NUMBER :FILE ID# 1904864-80T Thank you for choosing CONTRACT BUILDING COMPONENTS 14540 INDUSTRIAL PKWY. MARYSVILLE, OH 43040 Any Questions, please call (937) 644-0739QTY SPANLUMBERTOP BOTOVERHANGLEFT RIGHTCANTILEVERLEFT RIGHTPITCHTOP BOTIDFT-IN-16PROFILERoof TrussesPLYINFORMATION BY EACH TRUSSTOTALPRICEPRICEUNITT-424 1 8.00 0.0015-03-0000-10-08 00-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 47.08Ship Ht = 4 - 9 -13T-426 5 8.00 0.0004-05-0000-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 14.13Ship Ht = 3 - 5 -13T-427 4 8.00 0.0002-03-1500-10-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 7.25Ship Ht = 2 - 1 - 2T-428 2 8.00 0.0021-05-0001-01-12 01-00-1200-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 71.95Ship Ht = 7 - 8 - 2T-429 210.00 0.0022-08-0800-10-0800-00-00 00-00-002 X 2 X 4 2BRDFT =Weight = 410.76Ship Ht =12 - 3 -12T-431 310.00 0.0031-00-04 00-00-00 00-00-002 X 6 2 X 8BRDFT =Weight = 239.51Ship Ht =12 - 3 -12T-431A 610.00 0.0031-00-04 00-00-00 00-00-002 X 6 2 X 8BRDFT =Weight = 239.51Ship Ht =12 - 3 -12T-433 4 8.00 0.0035-11-0000-10-08 08-06-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 157.60Ship Ht =12 - 6 - 2T-433A 1 8.00 0.0035-00-0800-10-08 07-09-1200-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 159.19Ship Ht =10 - 3 -13T-433B 1 8.00 0.0035-11-0000-10-08 08-06-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 167.95Ship Ht =11 - 7 -13T-434 2 8.00 0.0035-11-0000-10-08 08-06-0800-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 157.60Ship Ht =12 - 6 - 2T-435 1 8.00 0.0035-11-0000-10-08 06-08-1500-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 162.16Ship Ht =12 - 6 - 2T-436 1 8.00 0.0035-11-0000-10-08 04-08-1500-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 162.19Ship Ht =12 - 6 - 2T-437 1 8.00 0.0035-11-0000-10-08 02-08-1500-00-00 00-00-002 X 4 2 X 4BRDFT =Weight = 163.24Ship Ht =12 - 6 - 2FT-IN-16ITEM TYPEQTY SIZELENGTHPART NUMBERNOTESItemsTOTALPRICEPRICEUNIT - -HGUS210-2Hanger 1 - -HGUS26Hanger 5 - -HGUS26-2Hanger 1 - -HUS26Hanger 8 - -HUS28Hanger 10 - -LUS24Hanger 18 - -LUS26Hanger 1 - -LUS410Hanger 10 - -THJA26Hanger 3 - -TJC37Hanger 4 2PAGE Tallest Ship ht. = 12 - 6 - 2 Trusses = 145 Total Brdft. = Weight = 7,650.5 Designs = 36 D4 Elev (A or B) with (SP or SR), EP, and BR`General Notes:(do not scale this drawing)This is a Truss Placement Plan and is for reference purposes only. Installer is responsibe for proper placement.Exterior dimensions are from face of sheeting.Stubbed trusses and/or raised heels are to exterior face of stud to allow for continuous sheeting.Interior dimensions are from face of stud.Reference individual truss drawings for additional connection and bracing information.HEEL HEIGHTTHIS END 1-3-4HEEL HEIGHTTHIS END 0-10-1RAFTER FRAMING OVER FLOOR TRUSSES PER A.705.RIDGE BEAMS TO POST ONTO FLAT TOP OF GIRDER TRUSSES.TJC37TJC37TJC37TJC37THJA26LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24TJC37TJC37TJC37TJC37THJA26HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS26HUS26LUS24LUS24HGUS26-2HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS210LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS410HGUS28-4LUS410LUS410LUS24LUS24LUS26THJA26LUS24LUS24LUS24HUS26HUS26HUS26HGUS210-2VALLEY OVER FRAMINGBY OTHERSREFERENCE SHEETA.705 NOTE 7VALLEY OVER FRAMINGBY OTHERSREFERENCE SHEETA.705 NOTE 7ROOF FRAMING BYOTHERSREFERENCE SHEETA.705NOTE: FRAMER -SEE TRUSSDRAWINGS FORCANTILEVER. DONOT FLIP TRUSSES!D4 Elev (A or B) with (SP or SR), EP, and BR`General Notes:(do not scale this drawing)This is a Truss Placement Plan and is for reference purposes only. Installer is responsibe for proper placement.Exterior dimensions are from face of sheeting.Stubbed trusses and/or raised heels are to exterior face of stud to allow for continuous sheeting.Interior dimensions are from face of stud.Reference individual truss drawings for additional connection and bracing information.HEEL HEIGHTTHIS END 1-3-4HEEL HEIGHTTHIS END 0-10-1RAFTER FRAMING OVER FLOOR TRUSSES PER A.705.RIDGE BEAMS TO POST ONTO FLAT TOP OF GIRDER TRUSSES.TJC37TJC37TJC37TJC37THJA26LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24TJC37TJC37TJC37TJC37THJA26HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS26HUS26LUS24LUS24HGUS26-2HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS210LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS410HGUS28-4LUS410LUS410LUS24LUS24LUS26THJA26LUS24LUS24LUS24HUS26HUS26HUS26HGUS210-2VALLEY OVER FRAMINGBY OTHERSREFERENCE SHEETA.705 NOTE 7VALLEY OVER FRAMINGBY OTHERSREFERENCE SHEETA.705 NOTE 7ROOF FRAMING BYOTHERSREFERENCE SHEETA.705NOTE: FRAMER -SEE TRUSSDRAWINGS FORCANTILEVER. DONOT FLIP TRUSSES!F-401DBLF-401AGT-406T-407T-408T-409T-433AT-433BT-435T-436T-437HT-300AT-405T-401T-405T-401T-404GT-419BGT-428GT-430GT-430AGT-431GT-420BT-421BT-422BGT-426T-424HT-438HT-438T-427T-427T-427T-427GT-423C-423C-423T-433(4)T-434(2)T-404(9)T-428(2)C-423(8) T-429(2)F-401C(3)F-401(4)F-401B(5)F-401(3)T-431A(6)T-431(2)T-403(5)T-426(5)T-415B(3)34' 4"6' 9 3/4"10 1/4"42' 0" 23' 1" 6' 10" 12' 1"42' 0" 73' 3"13' 8" 14' 5 1/4"28' 4" 2' 5"73' 4"8' 10 3/4" 13' 9" 8' 4 1/2"9' 3"13' 2"8' 5 1/2"1' 4"1' 4"9 1/2"1' 10 1/4"2' 0" 1' 4"1' 4"1' 4"1' 4"1' 4"1' 0 1/2"1' 4"2' 0" 2' 0" 1' 0 3/4"5' 0" 12' 0" F-401DBLF-401AGT-406T-407T-408T-409T-433AT-433BT-435T-436T-437HT-300AT-405T-401T-405T-401T-404GT-419BGT-428GT-430GT-430AGT-431GT-420BT-421BT-422BGT-426T-424HT-438HT-438T-427T-427T-427T-427GT-423C-423C-423T-433(4)T-434(2)T-404(9)T-428(2)C-423(8) T-429(2)F-401C(3)F-401(4)F-401B(5)F-401(3)T-431A(6)T-431(2)T-403(5)T-426(5)T-415B(3)34' 4"6' 9 3/4"10 1/4"42' 0" 23' 1" 6' 10" 12' 1"42' 0" 73' 3"13' 8" 14' 5 1/4"28' 4" 2' 5"73' 4"8' 10 3/4" 13' 9" 8' 4 1/2"9' 3"13' 2"8' 5 1/2"1' 4"1' 4"9 1/2"1' 10 1/4"2' 0" 1' 4"1' 4"1' 4"1' 4"1' 4"1' 0 1/2"1' 4"2' 0" 2' 0" 1' 0 3/4"5' 0" 12' 0" `General Notes:(do not scale this drawing)This is a Truss Placement Plan and is for reference purposes only. Installer is responsibe for proper placement.Exterior dimensions are from face of sheeting.Stubbed trusses and/or raised heels are to exterior face of stud to allow for continuous sheeting.Interior dimensions are from face of stud.Reference individual truss drawings for additional connection and bracing information.HEEL HEIGHTTHIS END 1-3-4HEEL HEIGHTTHIS END 0-10-1RAFTER FRAMING OVER FLOOR TRUSSES PER A.705.RIDGE BEAMS TO POST ONTO FLAT TOP OF GIRDER TRUSSES.TJC37TJC37TJC37TJC37THJA26LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24TJC37TJC37TJC37TJC37THJA26HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS26HUS26LUS24LUS24HGUS26-2HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS210LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS410HGUS28-4LUS410LUS410LUS24LUS24LUS26THJA26LUS24LUS24LUS24HUS26HUS26HUS26HGUS210-2VALLEY OVER FRAMINGBY OTHERSREFERENCE SHEETA.705 NOTE 7VALLEY OVER FRAMINGBY OTHERSREFERENCE SHEETA.705 NOTE 7ROOF FRAMING BYOTHERSREFERENCE SHEETA.705NOTE: FRAMER -SEE TRUSSDRAWINGS FORCANTILEVER. DONOT FLIP TRUSSES!D4 Elev (A or B) with (SP or SR), EP, and BR (mirrored) `General Notes:(do not scale this drawing)This is a Truss Placement Plan and is for reference purposes only. Installer is responsibe for proper placement.Exterior dimensions are from face of sheeting.Stubbed trusses and/or raised heels are to exterior face of stud to allow for continuous sheeting.Interior dimensions are from face of stud.Reference individual truss drawings for additional connection and bracing information.HEEL HEIGHTTHIS END 1-3-4HEEL HEIGHTTHIS END 0-10-1RAFTER FRAMING OVER FLOOR TRUSSES PER A.705.RIDGE BEAMS TO POST ONTO FLAT TOP OF GIRDER TRUSSES.TJC37TJC37TJC37TJC37THJA26LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24LUS24TJC37TJC37TJC37TJC37THJA26HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS26HUS26LUS24LUS24HGUS26-2HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS28HUS210LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS410HGUS28-4LUS410LUS410LUS24LUS24LUS26THJA26LUS24LUS24LUS24HUS26HUS26HUS26HGUS210-2VALLEY OVER FRAMINGBY OTHERSREFERENCE SHEETA.705 NOTE 7VALLEY OVER FRAMINGBY OTHERSREFERENCE SHEETA.705 NOTE 7ROOF FRAMING BYOTHERSREFERENCE SHEETA.705NOTE: FRAMER -SEE TRUSSDRAWINGS FORCANTILEVER. DONOT FLIP TRUSSES!F-401DBLF-401AGT-406T-407T-408T-409T-433AT-433BT-435T-436T-437HT-300AT-405T-401T-405T-401T-404GT-419BGT-428GT-430GT-430AGT-431GT-420BT-421BT-422BGT-426T-424HT-438HT-438T-427T-427T-427T-427GT-423C-423C-423T-433(4)T-434(2)T-404(9)T-428(2)C-423(8) T-429(2)F-401C(3)F-401(4)F-401B(5)F-401(3)T-431A(6) T-431(2)T-403(5)T-426(5)T-415B(3)34' 4"6' 9 3/4"10 1/4"42' 0" 23' 1"6' 10"12' 1"42' 0" 73' 3"13' 8"14' 5 1/4"28' 4"2' 5"73' 4"8' 10 3/4"13' 9"8' 4 1/2"9' 3"13' 2"8' 5 1/2"1' 4"1' 4"9 1/2"1' 10 1/4"2' 0" 1' 4"1' 4"1' 4"1' 4"1' 4"1' 0 1/2"1' 4"2' 0" 2' 0" 1' 0 3/4"5' 0" 12' 0" F-401DBLF-401AGT-406T-407T-408T-409T-433AT-433BT-435T-436T-437HT-300AT-405T-401T-405T-401T-404GT-419BGT-428GT-430GT-430AGT-431GT-420BT-421BT-422BGT-426T-424HT-438HT-438T-427T-427T-427T-427GT-423C-423C-423T-433(4)T-434(2)T-404(9)T-428(2)C-423(8) T-429(2)F-401C(3)F-401(4)F-401B(5)F-401(3)T-431A(6) T-431(2)T-403(5)T-426(5)T-415B(3)34' 4"6' 9 3/4"10 1/4"42' 0" 23' 1"6' 10"12' 1"42' 0" 73' 3"13' 8"14' 5 1/4"28' 4"2' 5"73' 4"8' 10 3/4"13' 9"8' 4 1/2"9' 3"13' 2"8' 5 1/2"1' 4"1' 4"9 1/2"1' 10 1/4"2' 0" 1' 4"1' 4"1' 4"1' 4"1' 4"1' 0 1/2"1' 4"2' 0" 2' 0" 1' 0 3/4"5' 0" 12' 0" DE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under my direct supervision and control based on the parameters provided by Contract Building Components. Job: 1904864-80T 36 truss design(s) 67051-W3 7/30/19 Samuel A. Greenberg, P.E. Ohio Reg. #59715 COA: 02356 Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length is the distance from the top chord to bottom chord. The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1-2014 Chapter 2. Further, the attached truss designs comply with the letter and intent of the 2019 Ohio Residential Building Code (ORBC). Warning !—Verify design parameters and read notes before use. These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate Institute, 583 D’Onofrio Drive, Madison, WI 53719 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss C-423 Truss Type Piggyback Qty 11 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:50 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-lL0nK8hJURDOz9bhqevmdQk2ttkVa7ZmYvFcGnyswkh Scale = 1:10.2 T1 T1 B11 2 3 45 3x4 2x4 2x4 2-0-0 2-0-0 4-0-0 2-0-0 2-0-0 2-0-0 4-0-0 2-0-0 0-4-131-8-00-1-80-4-130-1-810.0012 Plate Offsets (X,Y)-- [2:0-2-1,0-1-0], [3:0-2-0,Edge], [4:0-2-1,0-1-0] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 17.9/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.03 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 4 4 4 4 l/defl n/r n/r n/a n/r L/d 180 90 n/a 120 PLATES MT20 Weight: 9 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 BRACING- TOP CHORDStructural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=126/2-8-14 (min. 0-1-8), 4=126/2-8-14 (min. 0-1-8) Max Horz2=-27(LC 14) Max Uplift2=-5(LC 16), 4=-5(LC 17) Max Grav2=155(LC 23), 4=155(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=17.9 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=0.93; Ct=1.10 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 19.3 psf on overhangs non-concurrent with other live loads. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 13) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-406 Truss Type Hip Girder Qty 1 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:53 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-9whwyAjBnMbzqcJFVmTTE3MLi4YwnGLCEtUGt6yswke Scale = 1:64.9 T1 T2 T4 B1 B3 B4 B5 B6W12 W7 W3 W2 W1 W5 W8 W10 T3 B2 W9 W12W11 W6 W4 O1 1 2 3 4 5 6 78 9 10 2019 18 1716 15 14 13 12 11 4x5 5x6 3x6 10x14 MT18HS 5x8 WB 5x10 MT18HS 2x4 8x10 4x5 2x4 4x5 2x4 8x8 3x4 6x8 5x8 3x4 4x10 3x5 THJA26 LUS24 LUS24LUS24 LUS24 LUS24 LUS24 LUS24LUS24 LUS24 LUS24LUS24 LUS24LUS24 Special0-1-131-0-4 1-0-4 6-8-0 5-7-12 14-7-0 7-11-0 22-6-0 7-11-0 29-3-0 6-9-0 32-9-0 3-6-0 35-0-8 2-3-8 1-0-4 1-0-4 6-8-0 5-7-12 10-6-10 3-10-10 14-7-0 4-0-6 22-6-0 7-11-0 29-3-0 6-9-0 32-9-0 3-6-0 35-0-8 2-3-8 0-6-84-10-04-11-131-1-81-0-04-10-08.0012 Plate Offsets (X,Y)-- [2:0-2-4,0-1-12], [3:0-3-0,0-2-3], [4:0-2-0,0-1-8], [8:0-4-12,0-2-0], [9:0-2-0,0-2-0], [10:Edge,0-8-2], [11:0-1-12,0-0-0], [13:0-4-0,0-0-0], [15:0-3-4,Edge], [16:0-3-8 ,Edge], [17:0-1-8,0-2-4] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.95 0.99 0.96 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.57 -0.86 0.20 (loc) 16-17 16-17 11 l/defl >716 >474 n/a L/d 360 240 n/a PLATES MT20 MT18HS Weight: 331 lb FT = 12% GRIP 197/144 197/144 LUMBER- TOP CHORD2x4 SPF No.2 *Except* T2: 2x4 SP 2400F 2.0E, T3: 2x4 SPF 2100F 1.8E BOT CHORD2x4 SPF No.2 *Except* B1,B6: 2x6 SPF No.2, B4,B2: 2x4 SPF 2100F 1.8E WEBS2x4 SPF Stud *Except* W2,W1,W5,W11: 2x4 SPF No.2, W10: 2x3 SPF Stud OTHERS2x3 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 4-0-13 oc purlins, except end verticals, and 2-0-0 oc purlins (4-2-4 max.): 3-8. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. REACTIONS.(lb/size)11=3839/Mechanical, 20=3840/0-3-8 (min. 0-3-4) Max Horz20=90(LC 11) Max Uplift11=-685(LC 8), 20=-670(LC 9) Max Grav11=4196(LC 35), 20=4169(LC 35) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-782/98, 2-3=-6046/1079, 3-4=-4984/910, 4-24=-8711/1512, 5-24=-8711/1512, 5-6=-10371/1761, 6-25=-10371/1761, 25-26=-10371/1761, 7-26=-10371/1761, 7-27=-10543/1789, 8-27=-10540/1789, 8-9=-7331/1240, 9-10=-7665/1283, 10-11=-4077/679 BOT CHORD1-20=-114/730, 19-20=-181/730, 18-19=-1260/7052, 18-28=-1258/7039, 28-29=-1258/7039, 17-29=-1258/7039, 17-30=-181/992, 30-31=-181/992, 31-32=-181/992, 32-33=-181/992, 16-33=-181/992, 15-16=-116/661, 7-15=-884/145, 15-34=-995/6116, 34-35=-995/6116, 35-36=-995/6116, 14-36=-995/6116, 14-37=-1062/6493, 13-37=-1062/6494, 9-13=-85/480, 11-12=-60/379 WEBS2-20=-3668/712, 3-19=-572/3061, 5-17=-1414/230, 15-17=-1365/7812, 5-15=-289/1791, 8-15=-902/4988, 8-14=-251/1403, 9-14=-688/166, 2-19=-824/4391, 10-13=-971/5915, 4-19=-3111/551, 4-17=-453/2556 NOTES-(20) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-4-0 oc, Except member 19-3 2x4 - 1 row at 0-9-0 oc, member 5-17 2x4 - 1 row at 0-9-0 oc, member 17-15 2x4 - 1 row at 0-9-0 oc, member 15-5 2x4 - 1 row at 0-9-0 oc, member 8-15 2x4 - 1 row at 0-9-0 oc, member 14-8 2x4 - 1 row at 0-9-0 oc, member 2-19 2x4 - 1 row at 0-9-0 oc, member 13-10 2x4 - 1 row at 0-9-0 oc, member 19-4 2x4 - 1 row at 0-9-0 oc, member 4-17 2x4 - 1 row at 0-9-0 oc, 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (19.3 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-406 Truss Type Hip Girder Qty 1 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:53 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-9whwyAjBnMbzqcJFVmTTE3MLi4YwnGLCEtUGt6yswke NOTES-(20) 6) Roof design snow load has been reduced to account for slope. 7) Unbalanced snow loads have been considered for this design. 8) Provide adequate drainage to prevent water ponding. 9) All plates are MT20 plates unless otherwise indicated. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Refer to girder(s) for truss to truss connections. 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=685, 20=670. 14) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 15) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Right Hand Hip) or equivalent at 6-8-6 from the left end to connect truss(es) T-404 (1 ply 2x4 SPF), HT-300A (1 ply 2x4 SPF) to back face of bottom chord. 17) Use Simpson Strong-Tie LUS24 (4-10d Girder, 2-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 8-8-12 from the left end to 31-2-4 to connect truss(es) T-404 (1 ply 2x4 SPF), T-403 (1 ply 2x4 SPF) to back face of bottom chord. 18) Fill all nail holes where hanger is in contact with lumber. 19) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 290 lb down and 87 lb up at 32-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 20) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-59, 3-8=-58, 8-10=-59, 16-21=-20, 13-15=-20, 11-12=-20 Concentrated Loads (lb) Vert: 18=-290(B) 19=-879(B) 17=-290(B) 14=-290(B) 13=-290(B) 28=-290(B) 29=-290(B) 30=-290(B) 31=-290(B) 32=-290(B) 33=-290(B) 34=-290(B) 35=-290(B) 36=-290(B) 37=-290(B) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-419B Truss Type Attic Girder Qty 1 Ply 3 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:55 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-6JpgNslRJzrh3wTedBVxKURhyuGxFALViBzNy?yswkc Scale = 1:97.4 T2 T3 T4 B1 W13 W10 W9 W5 W4 W7 W8 W11 W12 W14 W15 W16 W17 W1 W2 T1 B2 W3 W6 HW1 F1 1 2 3 4 5 6 7 8 9 10 11 2120 19 181716 15 14 1312 23 22 4x8 5x6 8x12 MT18HS 8x8 10x10 4x4 3x6 4x5 7x10 MT18HS 12x12 4x5 8x20 8x8 8x8 6x16 MT18HS 12x12 4x5 10x10 4x14 4x4 10x14 MT18HS 10x20 MT18HS 6x16 MT18HS LUS410 LUS410 LUS410 LUS410 LUS410 LUS410 LUS410 LUS410 LUS410 LUS410 Special HUS26 HUS26 HUS26 HGUS26 HGUS26 HGUS26 HGUS26 HGUS26 HUS28 HGUS26-2 LUS24 LUS24 5-3-2 5-3-2 10-2-11 4-11-9 15-2-4 4-11-9 17-1-0 1-10-12 18-2-4 1-1-4 21-2-4 3-0-0 24-10-5 3-8-1 29-6-12 4-8-7 34-10-1 5-3-5 40-1-6 5-3-5 41-10-0 1-8-10 5-3-2 5-3-2 10-2-11 4-11-9 15-2-4 4-11-9 17-1-0 1-10-12 21-2-4 4-1-4 24-10-5 3-8-1 29-6-12 4-8-7 32-8-13 3-2-1 35-10-14 3-2-1 41-10-0 5-11-2 1-1-84-2-512-6-30-4-128.0012 3.7112 Plate Offsets (X,Y)-- [2:0-1-12,0-2-0], [4:0-2-6,0-2-12], [8:0-1-8,0-2-4], [9:0-4-8,0-5-0], [11:0-7-7,0-0-8], [12:0-10-15,Edge], [13:0-5-0,0-6-8], [14:0-3-8,0-8-0], [16:0-9-4,Edge], [17:0-3-8,0-3-12], [18:0-3-8,0-8-0], [20:0-2-8,0-2-8], [22:0-1-12,0-1-12], [23:0-10-0,0-2-8], [24:0-1-13,0-2-12] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.90 0.89 0.93 DEFL. Vert(LL) Vert(CT) Horz(CT) Attic in -0.68 -1.18 0.14 -0.20 (loc) 16-17 16-17 12 17-18 l/defl >720 >415 n/a 362 L/d 360 240 n/a 360 PLATES MT20 MT18HS Weight: 1153 lb FT = 12% GRIP 197/144 197/144 LUMBER- TOP CHORD2x6 SPF No.2 *Except* T3: 2x6 SP 2400F 2.0E, T4: 2x10 SP 2400F 2.0E BOT CHORD2x10 SP 2400F 2.0E *Except* B1: 2x10 SP No.1 WEBS2x4 SPF Stud *Except* W5,W4,W14,W17,W1: 2x4 SPF No.2 W7,W8,W12,W6: 2x4 SPF 1650F 1.5E, W11: 2x4 SPF 2100F 1.8E OTHERS2x6 SPF No.2 WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 4-10-5 oc purlins. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. JOINTS1 Brace at Jt(s): 22 REACTIONS.(lb/size)1=7605/0-3-8 (req. 0-3-8), 12=20369/0-4-15 (req. 0-6-5) Max Horz1=-225(LC 8) Max Grav1=9458(LC 4), 12=22780(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-14240/0, 2-3=-14857/0, 3-4=-14815/0, 4-32=-1533/5574, 5-32=-1390/5620, 5-6=-861/1142, 6-7=-833/1759, 7-8=-20013/0, 8-9=-30146/0, 9-10=-43138/0, 10-11=-46733/0, 11-12=-42433/0 BOT CHORD1-21=0/11633, 21-33=0/11633, 33-34=0/11633, 20-34=0/11633, 20-35=0/12339, 19-35=0/12339, 19-36=0/12339, 36-37=0/12339, 18-37=0/12339, 18-38=0/16348, 38-39=0/16348, 39-40=0/16348, 40-41=0/16348, 17-41=0/16348, 17-42=0/25114, 42-43=0/25114, 16-43=0/25114, 16-44=0/41187, 15-44=0/41187, 15-45=0/41187, 14-45=0/41187, 14-46=0/45324, 46-47=0/45324, 47-48=0/45324, 13-48=0/45324, 13-49=0/38980, 49-50=0/38980, 12-50=0/38980, 12-51=0/18034 WEBS2-21=-886/0, 2-20=-8/974, 4-20=-2713/70, 4-18=0/7220, 18-23=0/2891, 5-23=-6079/509, 7-17=0/12592, 8-17=-18209/0, 8-16=0/20852, 9-16=-20101/0, 9-14=0/9318, 10-14=-5717/0, 10-13=-1194/913, 11-13=0/9158, 22-23=-20972/0, 7-22=-17429/0, 6-22=-1702/733, 5-22=-715/4529, 4-23=-22198/0 NOTES-(26) 1) N/A 2) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc, 2x10 - 5 rows staggered at 0-4-0 oc. Bottom chords connected as follows: 2x10 - 5 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 5-18 2x4 - 1 row at 0-7-0 oc, member 23-7 2x4 - 1 row at 0-4-0 oc. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 4) Unbalanced roof live loads have been considered for this design. 5) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 Continued on page 2 2x10x24"SP 2400F 2.0E BEARING BLOCK.ATTACH TOONEFACEUSING(2)ROWSSIMPSON1/4"X6" SDSSCREWS@4"O.C.STAGGERED THROUGHOUT.KEEP4"ENDDISTANCEAND1" EDGE DISTANCE. DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-419B Truss Type Attic Girder Qty 1 Ply 3 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:55 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-6JpgNslRJzrh3wTedBVxKURhyuGxFALViBzNy?yswkc NOTES-(26) 6) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (19.3 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 7) Roof design snow load has been reduced to account for slope. 8) Unbalanced snow loads have been considered for this design. 9) All plates are MT20 plates unless otherwise indicated. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 12) Ceiling dead load (10.0 psf) on member(s). 22-23, 7-22; Wall dead load (5.0psf) on member(s).18-23, 7-17 13) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 17-18 14) WARNING: Required bearing size at joint(s) 12 greater than input bearing size. 15) Solid blocking is required on both sides of the truss at joint(s), 12. 16) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 17) Use Simpson Strong-Tie LUS410 (8-10d Girder, 6-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 7-10-4 from the left end to 21-6-12 to connect truss(es) F-401C (1 ply 2x4 SPF), F-401 (1 ply 2x4 SPF) to front face of bottom chord. 18) Use Simpson Strong-Tie HUS26 (14-10d Girder, 6-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 24-9-12 from the left end to 28-9-12 to connect truss(es) T-431 (1 ply 2x8 SP) to front face of bottom chord. 19) Use Simpson Strong-Tie HGUS26 (20-10d Girder, 6-10d Truss) or equivalent spaced at 2-0-0 oc max. starting at 30-9-12 from the left end to 38-9-12 to connect truss(es) T-431A (1 ply 2x8 SP) to front face of bottom chord. 20) Use USP HUS28 (With 22-16d nails into Girder & 8-16d nails into Truss) or equivalent at 40-7-9 from the left end to connect truss(es) T-431A (1 ply 2x8 SP) to front face of bottom chord. 21) Use Simpson Strong-Tie HGUS26-2 (20-10d Girder, 6-10d Truss) or equivalent at 34-3-8 from the left end to connect truss(es) GT-420B (2 ply 2x6 SPF) to back face of bottom chord. 22) Use Simpson Strong-Tie LUS24 (4-10d Girder, 2-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 36-2-12 from the left end to 38-2-12 to connect truss(es) T-421B (1 ply 2x4 SPF), T-422B (1 ply 2x4 SPF) to back face of bottom chord. 23) Fill all nail holes where hanger is in contact with lumber. 24) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 276 lb down at 22-7-4, and 4235 lb down and 519 lb up at 22-10-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 25) Attic room checked for L/360 deflection. 26) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-6=-58, 6-9=-59, 9-30=-59, 18-25=-20, 17-18=-30, 12-17=-20, 7-23=-20 Drag: 18-23=-10, 7-17=-10 Concentrated Loads (lb) Vert: 18=-200(F) 16=-1896(F) 13=-2017(F) 12=-2029(F) 29=-8(B) 33=-65(F) 34=-65(F) 35=-65(F) 37=-200(F) 38=-200(F) 39=-200(F) 40=-200(F) 41=-200(F) 42=-200(F) 43=-3361(F) 44=-1896(F) 45=-1896(F) 46=-2017(F) 47=-2017(F) 48=-1577(B) 49=-106(B) 50=-2017(F) 51=-2017(F) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-420B Truss Type JACK-CLOSED GIRDER Qty 1 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:56 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-aVN3bCm34HzYh42qAv0Ash_w9IeX_qofwriwURyswkb Scale = 1:16.3 T1 W1 B1 HW1 W21 2 3 54 1.5x4 2x4 2x4 1.5x4 5x6 5x8 HUS26 HUS26 1-3-1 1-3-1 3-10-12 2-7-11 3-4-5 3-4-5 6-9-15 3-5-10 0-6-82-7-143.7112 Plate Offsets (X,Y)-- [1:0-2-1,0-1-11] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.68 0.74 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.22 0.02 (loc) 4-5 4-5 1 l/defl >633 >369 n/a L/d 360 240 n/a PLATES MT20 Weight: 49 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x6 SPF 2100F 1.8E WEBS2x4 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=1702/Mechanical, 1=1452/0-4-15 (min. 0-1-8) Max Horz1=67(LC 11) Max Uplift4=-33(LC 12), 1=-23(LC 8) Max Grav4=2045(LC 3), 1=1713(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD3-4=-290/25 WEBS2-5=-113/376 NOTES-(14) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Roof design snow load has been reduced to account for slope. 6) Unbalanced snow loads have been considered for this design. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 1. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Use Simpson Strong-Tie HUS26 (14-10d Girder, 6-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 3-1-7 from the left end to 5-1-7 to connect truss(es) T-415B (1 ply 2x4 SPF) to front face of bottom chord. 13) Fill all nail holes where hanger is in contact with lumber. 14) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-420B Truss Type JACK-CLOSED GIRDER Qty 1 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:57 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-2hxRoYnirb5PJDd1kcXPPvX5vhzljH2o9VST0tyswka LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-58, 4-6=-20 Concentrated Loads (lb) Vert: 5=-1314(F) 11=-1314(F) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-423 Truss Type Common Girder Qty 1 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:58 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-WuVp?unKbuDGwNCDIK2ex63LZ5PVSaVyO9B1YJyswkZ Scale = 1:34.5 T1 T1 B1 W1 2 1 4 3 8x8 8x8 4x12 5x6 HGUS210-2 HUS26HUS26HUS26 4-0-10 4-0-10 7-7-8 3-6-14 11-2-6 3-6-14 15-3-0 4-0-10 4-0-10 4-0-10 7-7-8 3-6-14 11-2-6 3-6-14 15-3-0 4-0-10 0-6-85-7-80-6-88.0012 Plate Offsets (X,Y)-- [1:0-9-2,0-1-12], [3:0-0-14,0-3-12], [4:0-7-12,0-2-0] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.37 0.32 0.71 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.10 0.01 (loc) 4-10 4-10 3 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 192 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x6 SPF No.2 BOT CHORD2x10 SP 2400F 2.0E WEBS2x4 SPF No.2 BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=4017/0-3-8 (min. 0-1-11), 3=8247/0-3-8 (min. 0-3-7) Max Horz1=81(LC 38) Max Uplift1=-96(LC 12) Max Grav1=4082(LC 18), 3=8312(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-13=-5588/0, 2-13=-5468/17, 2-14=-5452/23, 3-14=-5581/0 BOT CHORD1-15=0/4486, 4-15=0/4486, 4-16=0/4486, 16-17=0/4486, 17-18=0/4486, 3-18=0/4486 WEBS2-4=0/5771 NOTES-(15) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-2-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6) Roof design snow load has been reduced to account for slope. 7) Unbalanced snow loads have been considered for this design. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Use Simpson Strong-Tie HGUS210-2 (46-10d Girder, 16-10d Truss) or equivalent at 6-9-8 from the left end to connect truss(es) GT-406 (2 ply 2x6 SPF) to front face of bottom chord. 13) Use Simpson Strong-Tie HUS26 (14-10d Girder, 6-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 8-8-12 from the left end to 12-8-12 to connect truss(es) T-407 (1 ply 2x4 SPF), T-408 (1 ply 2x4 SPF), T-409 (1 ply 2x4 SPF) to front face of bottom chord. 14) Fill all nail holes where hanger is in contact with lumber. 15) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) StandardContinued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-423 Truss Type Common Girder Qty 1 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:58 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-WuVp?unKbuDGwNCDIK2ex63LZ5PVSaVyO9B1YJyswkZ LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 2-7=-58, 2-11=-59, 1-3=-20 Concentrated Loads (lb) Vert: 3=-2238 15=-4176(F) 16=-1545(F) 17=-1563(F) 18=-1677(F) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-426 Truss Type Hip Girder Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:59 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-_43BDDoyMCL7YXnPs1ZtUKcMeViSB8B5cpxa5myswkY Scale = 1:25.0 T1 T2 T1 B1 W1 W1 W2 W21 2 3 4 5 6 10 9 87 3x6 4x5 4x5 3x6 2x4 2x4 2x4 1.5x4 2x4 1.5x4 THJA26 LUS24LUS24LUS24 THJA26 1-2-8 1-2-8 4-5-0 3-2-8 10-10-0 6-5-0 14-0-8 3-2-8 15-3-0 1-2-8 1-2-8 1-2-8 4-5-0 3-2-8 10-10-0 6-5-0 14-0-8 3-2-8 15-3-0 1-2-8 0-6-83-5-130-6-83-5-138.0012 Plate Offsets (X,Y)-- [1:0-1-10,0-1-8], [3:0-3-4,0-2-4], [4:0-3-4,0-2-4], [6:0-1-10,0-1-8] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.99 0.53 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.19 0.01 (loc) 8-9 8-9 7 l/defl >999 >831 n/a L/d 360 240 n/a PLATES MT20 Weight: 61 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 *Except* T2: 2x4 SPF 1650F 1.5E BOT CHORD2x6 SP 2400F 2.0E WEBS2x3 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 4-6-10 oc purlins, except 2-0-0 oc purlins (2-10-13 max.): 3-4. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)10=1164/0-3-8 (min. 0-1-8), 7=1164/0-3-8 (min. 0-1-8) Max Horz10=-55(LC 8) Max Uplift10=-223(LC 12), 7=-223(LC 13) Max Grav10=1285(LC 36), 7=1285(LC 36) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-1332/316, 2-3=-1385/317, 3-17=-1139/264, 17-18=-1139/264, 4-18=-1139/264, 4-5=-1385/317, 5-6=-1332/316 BOT CHORD1-10=-260/1127, 9-10=-261/1127, 9-19=-265/1139, 19-20=-265/1139, 20-21=-265/1139, 8-21=-265/1139, 7-8=-260/1127, 6-7=-260/1127 WEBS3-9=-195/490, 4-8=-194/490, 2-10=-473/127, 5-7=-473/127 NOTES-(17) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (19.3 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=223, 7=223. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Use Simpson Strong-Tie THJA26 (THJA26 on 1 ply, Right Hand Hip) or equivalent at 4-5-6 from the left end to connect truss(es) T-426 (1 ply 2x4 SPF), HT-438 (1 ply 2x4 SPF) to back face of bottom chord. 13) Use Simpson Strong-Tie LUS24 (4-10d Girder, 2-10d Truss, Single Ply Girder) or equivalent spaced at 1-1-12 oc max. starting at 6-5-12 from the left end to 8-9-4 to connect truss(es) T-426 (1 ply 2x4 SPF) to back face of bottom chord. 14) Use Simpson Strong-Tie THJA26 (THJA26 on 1 ply, Left Hand Hip) or equivalent at 10-9-10 from the left end to connect truss(es) T-426 (1 ply 2x4 SPF), HT-438 (1 ply 2x4 SPF) to back face of bottom chord. 15) Fill all nail holes where hanger is in contact with lumber. 16) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-426 Truss Type Hip Girder Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:44:59 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-_43BDDoyMCL7YXnPs1ZtUKcMeViSB8B5cpxa5myswkY 17) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-59, 3-4=-58, 4-6=-58, 11-14=-20 Concentrated Loads (lb) Vert: 9=-342(B) 8=-342(B) 19=-149(B) 20=-149(B) 21=-149(B) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-428 Truss Type COMMON GIRDER Qty 1 Ply 3 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:01 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-wSAyevqCupbqnrwozScLZlhpvJJefv5O47Qh9eyswkW Scale = 1:47.3 T1 T1 B1 W4 W2 W1 W3 W5 B2 HW1 HW11 2 3 4 5 9 8 76 4x5 8x8 3x4 3x8 12x12 3x4 3x8 6x10 8x16 MT18HS 6x10 8x16 MT18HS HUS28 HUS28 HUS28 HUS28HUS28HUS28 HUS28 HUS28 HUS28 1-3-8 1-3-8 6-0-0 4-8-8 10-8-8 4-8-8 15-5-8 4-9-0 20-2-8 4-9-0 21-5-0 1-2-8 1-3-8 1-3-8 6-0-0 4-8-8 10-8-8 4-8-8 15-5-8 4-9-0 20-2-8 4-9-0 21-5-0 1-2-8 0-6-87-8-30-6-88.0012 Plate Offsets (X,Y)-- [1:0-2-5,Edge], [1:0-2-4,0-3-0], [3:0-2-0,0-2-0], [4:0-1-8,0-1-8], [5:0-3-0,0-3-1], [5:0-2-5,Edge], [6:0-4-12,0-1-8], [7:0-6-0,0-8-0] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.55 0.87 0.78 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.17 0.03 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 MT18HS Weight: 426 lb FT = 12% GRIP 197/144 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x10 SP No.1 *Except* B2: 2x10 SP 2400F 2.0E WEBS2x3 SPF Stud *Except* W1: 2x4 SPF No.2 WEDGE Left: 2x8 SP No.1 , Right: 2x8 SP No.1 BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=8483/0-3-8 (min. 0-3-8), 5=10382/0-3-8 (min. 0-3-2) Max Horz1=-131(LC 37) Max Grav1=8896(LC 5), 5=11295(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-10158/0, 2-18=-8957/0, 3-18=-8951/0, 3-19=-8956/0, 4-19=-8960/0, 4-5=-11062/0 BOT CHORD1-20=0/8360, 20-21=0/8360, 9-21=0/8360, 8-9=0/8360, 8-22=0/8360, 7-22=0/8360, 7-23=0/9125, 23-24=0/9125, 6-24=0/9125, 6-25=0/9125, 5-25=0/9125 WEBS2-9=0/1421, 2-7=-1377/0, 3-7=0/9542, 4-7=-2244/0, 4-6=0/2456 NOTES-(14) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x10 - 3 rows staggered at 0-5-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6) Roof design snow load has been reduced to account for slope. 7) Unbalanced snow loads have been considered for this design. 8) All plates are MT20 plates unless otherwise indicated. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Use USP HUS28 (With 22-16d nails into Girder & 8-16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 3-6-4 from the left end to 19-6-4 to connect truss(es) T-431 (1 ply 2x8 SP), T-431A (1 ply 2x8 SP) to back face of bottom chord. 13) Fill all nail holes where hanger is in contact with lumber. 14) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) StandardContinued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-428 Truss Type COMMON GIRDER Qty 1 Ply 3 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:01 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-wSAyevqCupbqnrwozScLZlhpvJJefv5O47Qh9eyswkW LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-59, 3-5=-58, 1-5=-20 Concentrated Loads (lb) Vert: 8=-1735(B) 6=-1996(B) 17=-1996(B) 20=-1735(B) 21=-1735(B) 22=-1996(B) 23=-1996(B) 24=-1996(B) 25=-1996(B) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-430 Truss Type ATTIC GIRDER Qty 1 Ply 4 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:02 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-PfkKrFqqf7jhP?V_X97a6yEtpifXOPhXJn9Eh5yswkV Scale = 1:80.3 T2 T3 T4 B1 W12 W11 W9 W1 W8 W5W5 T1 B2 B3W4 W4 W4W3 W3 W6 W7W3 W3 W3 W3 W10 W2 2 3 4 5 6 7 8 9 1 25 2422 19 16 13 12 23 21 20 18 17 15 14 11 10 26 27 6x8 8x8 4x6 5x10 MT18HS 4x5 6x8 5x10 MT18HS 3x6 3x5 4x12 3x12 5x8 6x8 3x4 8x8 1.5x4 4x4 3x6 3x8 1.5x4 3x8 1.5x4 3x8 1.5x4 3x4 3x4 3x4 3x4 8-1-141-2-04-2-14 4-2-14 7-5-14 3-3-0 9-4-8 1-10-10 9-8-11 0-4-3 10-9-11 1-1-0 11-3-1 0-5-6 13-1-11 1-10-10 15-0-5 1-10-10 16-10-15 1-10-10 18-9-9 1-10-10 20-7-14 1-10-6 22-6-12 1-10-14 22-8-8 0-1-12 4-2-14 4-2-14 7-5-14 3-3-0 9-8-11 2-2-13 11-11-0 2-2-5 14-1-8 2-2-8 18-1-8 4-0-0 20-4-0 2-2-8 22-6-5 2-2-5 22-6-12 0-0-7 22-8-8 0-1-12 0-6-812-3-128-5-151-2-012-3-1210.0012 Plate Offsets (X,Y)-- [1:0-3-8,Edge], [1:Edge,0-0-4], [5:0-4-14,0-1-12], [6:0-5-8,0-3-4], [7:0-5-8,0-3-4], [8:0-5-6,0-1-12], [9:0-3-2,0-2-0], [10:0-3-0,Edge], [13:0-2-0,0-1-8], [21:0-1-8 ,0-1-8], [23:0-5-12,Edge], [25:0-4-0,0-2-8] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 17.9/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.99 0.89 0.63 DEFL. Vert(LL) Vert(CT) Horz(CT) Attic in -0.47 -0.69 0.06 -0.24 (loc) 19-22 19-22 12 10-23 l/defl >574 >391 n/a 768 L/d 360 240 n/a 360 PLATES MT20 MT18HS Weight: 864 lb FT = 12% GRIP 197/144 197/144 LUMBER- TOP CHORD2x10 SP No.1 *Except* T2: 2x10 SP DSS, T3: 2x6 SPF No.2 BOT CHORD2x4 SPF 2100F 1.8E *Except* B3: 2x4 SPF No.2 WEBS2x4 SPF Stud *Except* W1,W10: 2x4 SPF No.2, W8: 2x4 SP 2400F 2.0E WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-7. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. JOINTS1 Brace at Jt(s): 26, 27, 15, 21, 18 REACTIONS.(lb/size)1=2200/0-3-8 (min. 0-1-8), 12=2887/0-3-8 (min. 0-1-10) Max Horz1=128(LC 16) Max Uplift12=-5(LC 16) Max Grav1=3856(LC 49), 12=5212(LC 49) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-4937/0, 2-3=-1802/0, 3-4=-1732/0, 4-32=-3217/91, 32-33=-2473/88, 5-33=-2043/81, 5-34=-5553/141, 6-34=-5512/151, 6-35=-5149/149, 7-35=-5149/149, 7-36=-5861/160, 8-36=-5893/151, 8-9=-2781/69, 10-12=-3894/78, 9-10=-3504/85 BOT CHORD1-25=-107/3510, 24-25=-551/20290, 22-24=-551/20290, 19-22=-232/16259, 16-19=0/12009, 13-16=0/6538, 12-13=-24/371, 21-23=-20277/562, 20-21=-13687/13, 18-20=-13687/13, 17-18=-8556/0, 15-17=-8556/0, 14-15=-2905/0, 11-14=-2905/0, 10-11=-106/3380 WEBS2-25=-101/3890, 2-23=-3456/118, 22-23=-2588/200, 4-23=-2781/220, 5-26=-177/6398, 26-27=-175/6367, 8-27=-130/4406, 6-26=-357/33, 7-27=-9/1112, 15-16=-35/2997, 13-15=-3233/0, 11-13=0/3799, 11-12=-3133/0, 21-22=-371/5145, 19-21=-2063/232, 18-19=-167/2624, 16-18=-3034/120, 23-25=-17220/455, 6-27=-2305/64 NOTES-(20) 1) Special connection required to distribute top chord loads equally between all plies. 2) 4-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x10 - 2 rows staggered at 0-5-0 oc, 2x6 - 3 rows staggered at 0-4-0 oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. Attach TC w/ 1/2" diam. bolts (ASTM A-307) in the center of the member w/washers at 4-0-0 oc. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 4) Unbalanced roof live loads have been considered for this design. 5) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 1-0-4 to 4-2-14, Interior(1) 4-2-14 to 14-1-8, Exterior(2E) 14-1-8 to 22-6-12 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 Continued on page 2 IN LIEU OF NAILS,APPLY (7) SIMPSON1/4"X6"SDSSCREWS INTOPCHORDWITHIN12"OF CONCENTRATEDLOADAT JOINT16-1-8.KEEP4"END DISTANCE,1"EDGEDISTANCE ANDMIN.11/4"SPACING BETWEENSCREWS.DONOT SCREWTHROUGHPLATES! PREDRILLUSING5/32"BITTO PREVENTLUMBERSPLITTING. DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-430 Truss Type ATTIC GIRDER Qty 1 Ply 4 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:02 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-PfkKrFqqf7jhP?V_X97a6yEtpifXOPhXJn9Eh5yswkV NOTES-(20) 6) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (17.9 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=0.93,1.00,0.93; Ct=1.10, Lu=50-0-0 7) Roof design snow load has been reduced to account for slope. 8) Unbalanced snow loads have been considered for this design. 9) Provide adequate drainage to prevent water ponding. 10) All plates are MT20 plates unless otherwise indicated. 11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 13) Ceiling dead load (10.0 psf) on member(s). 4-5, 5-26, 26-27, 8-27; Wall dead load (5.0psf) on member(s).4-23 14) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 21-23, 20-21, 18-20, 17-18, 15-17, 14-15, 11-14, 10-11 15) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12. 16) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 17) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 18) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 4046 lb down and 130 lb up at 16-1-8, and 1124 lb down and 36 lb up at 11-9-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. 19) Attic room checked for L/360 deflection. 20) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 4-30=-28, 4-5=-308(F=-270), 5-6=-28, 6-7=-29, 7-9=-28, 1-12=-10, 5-8=-10, 10-23=-15 Drag: 4-23=-5 Concentrated Loads (lb) Vert: 5=-600(F) 35=-2160(F) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-430A Truss Type ATTIC GIRDER Qty 1 Ply 4 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:04 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-L1s4Gxs5BkzPeIfNea92BNJEmWJPsIRqm5eLmzyswkT Scale = 1:76.6 T2 T3 T4 B1 W12 W11 W9 W1 HW1 W8 W3W3 T1 B2 B3W5 W5W5W2W2W6W7W2W2W2 W2 W10 W4 2 3 4 5 6 7 8 1 24 23 21 18 15 12 11 22 20 19 17 16 14 13 10 9 26 27 25 6x8 8x8 3x6 5x10 MT18HS 4x5 5x10 MT18HS 6x10 MT18HS 3x6 3x4 4x12 2x4 5x8 6x8 3x4 8x8 3x5 4x5 3x4 3x8 1.5x4 3x8 1.5x4 3x8 1.5x4 3x4 3x4 3x4 3x4 8-1-144-2-14 4-2-14 7-5-14 3-3-0 9-4-8 1-10-10 9-8-11 0-4-3 10-9-11 1-1-0 11-3-1 0-5-6 13-1-11 1-10-10 15-0-5 1-10-10 16-10-15 1-10-10 18-9-9 1-10-10 20-7-14 1-10-6 22-6-12 1-10-14 22-8-8 0-1-12 4-2-14 4-2-14 7-5-14 3-3-0 9-8-11 2-2-13 12-0-3 2-3-8 14-1-8 2-1-5 18-1-8 4-0-0 20-2-13 2-1-5 22-6-5 2-3-8 22-6-12 0-0-7 22-8-8 0-1-12 0-6-812-3-129-9-61-2-012-3-1210.0012 Plate Offsets (X,Y)-- [1:0-3-8,Edge], [1:Edge,0-0-4], [2:0-2-0,0-2-8], [5:Edge,0-6-12], [6:0-5-8,0-3-4], [7:0-5-8,0-3-4], [12:0-1-12,0-1-8], [20:0-1-12,0-1-8], [21:0-1-12,0-1-8], [22:0-6-4 ,Edge], [24:0-3-8,0-2-8], [26:0-2-4,0-1-8], [27:0-2-4,0-2-0] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 17.9/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.90 0.93 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) Attic in -0.58 -0.85 0.08 -0.30 (loc) 18-21 18-21 11 9-22 l/defl >468 >319 n/a 609 L/d 360 240 n/a 360 PLATES MT20 MT18HS Weight: 879 lb FT = 12% GRIP 197/144 197/144 LUMBER- TOP CHORD2x10 SP No.1 *Except* T2: 2x10 SP DSS, T3: 2x6 SPF No.2 BOT CHORD2x4 SPF 2100F 1.8E *Except* B3: 2x4 SPF 1650F 1.5E WEBS2x4 SPF Stud *Except* W1: 2x6 SP 2400F 2.0E, W8,W10: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-7. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. JOINTS1 Brace at Jt(s): 26, 27, 14, 20, 17 REACTIONS.(lb/size)1=2781/0-3-8 (min. 0-1-8), 11=3609/0-3-8 (min. 0-1-12) Max Horz1=304(LC 15) Max Grav1=4128(LC 30), 11=5618(LC 30) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-5266/162, 2-3=-1472/0, 3-4=-1379/0, 4-32=-2582/285, 32-33=-1907/240, 5-33=-1517/219, 5-6=-6073/572, 6-34=-6486/618, 7-34=-6486/618, 7-35=-8317/768, 8-35=-8402/755, 9-11=-3624/278, 9-25=-3286/271 BOT CHORD1-24=-345/3847, 23-24=-1795/23751, 21-23=-1795/23751, 18-21=-1018/19887, 15-18=-150/16306, 12-15=0/10597, 12-36=0/3139, 11-36=0/3139, 20-22=-24391/1755, 19-20=-18312/491, 17-19=-18312/491, 16-17=-13335/0, 14-16=-13335/0, 13-14=-7020/0, 10-13=-7020/0, 9-10=-270/1119 WEBS2-24=-337/4673, 2-22=-4562/288, 21-22=-2596/493, 4-22=-2468/583, 5-26=-713/7775, 26-27=-705/7721, 8-27=-594/6157, 6-26=-791/117, 7-27=-261/3793, 14-15=-143/3211, 12-14=-3752/41, 10-12=0/4538, 10-11=-4437/0, 20-21=-921/5086, 18-20=-1544/532, 17-18=-425/2404, 15-17=-3083/331, 22-24=-20426/1489, 6-27=-1610/115 NOTES-(19) 1) Special connection required to distribute top chord loads equally between all plies. 2) 4-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x10 - 2 rows staggered at 0-6-0 oc, 2x6 - 3 rows staggered at 0-4-0 oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Attach TC w/ 1/2" diam. bolts (ASTM A-307) in the center of the member w/washers at 4-0-0 oc. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 4) Unbalanced roof live loads have been considered for this design. 5) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 1-0-4 to 4-2-14, Interior(1) 4-2-14 to 14-1-8, Exterior(2E) 14-1-8 to 20-10-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 6) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (17.9 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=0.93,1.00,0.93; Ct=1.10, Lu=50-0-0Continued on page 2 IN LIEU OF NAILS,APPLY (7) SIMPSON1/4"X6"SDS SCREWSINTOPCHORD WITHIN12"OFCONCENTRATED LOADATJOINT16-1-8.KEEP4" ENDDISTANCE,1"EDGE DISTANCEANDMIN.11/4" SPACINGBETWEENSCREWS. DONOTSCREWTHROUGH PLATES!PREDRILLUSING5/32" BITTOPREVENTLUMBER SPLITTING. DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-430A Truss Type ATTIC GIRDER Qty 1 Ply 4 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:04 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-L1s4Gxs5BkzPeIfNea92BNJEmWJPsIRqm5eLmzyswkT NOTES-(19) 7) Roof design snow load has been reduced to account for slope. 8) Unbalanced snow loads have been considered for this design. 9) Provide adequate drainage to prevent water ponding. 10) All plates are MT20 plates unless otherwise indicated. 11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 13) Ceiling dead load (10.0 psf) on member(s). 4-5, 5-26, 26-27, 8-27, 8-25; Wall dead load (5.0psf) on member(s).4-22 14) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 20-22, 19-20, 17-19, 16-17, 14-16, 13-14, 10-13, 9-10 15) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 16) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 17) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 972 lb down and 117 lb up at 11-9-0, and 3498 lb down and 423 lb up at 16-1-8 on top chord. The design/selection of such connection device(s) is the responsibility of others. 18) Attic room checked for L/360 deflection. 19) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 4-30=-56, 4-5=-346(F=-270), 5-6=-56, 6-7=-58, 7-8=-56, 1-12=-20, 11-12=-58, 5-25=-20, 20-22=-30, 9-20=-30 Drag: 4-22=-10 Concentrated Loads (lb) Vert: 5=-600(F) 34=-2160(F) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-431 Truss Type Attic Girder Qty 1 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:06 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-HQ_rhduLjME7ucplm?BWGoOc6K3SKFp7DO7SqsyswkR Scale = 1:68.2 T2 T3 T2 B1 W3 W3 W1 HW1 T1 T4 B2 W2W2 W4W41 2 3 4 5 6 78 9 10 11 12 13 18 16 14 194x6 5x6 5x6 5x6 4x8 4x4 6x8 2x4 4x5 2x4 4x5 2x4 2x4 4x8 3x4 2x4 2x4 1-2-08-1-1413-9-0 8-2-12 8-2-12 19-7-8 11-4-12 22-3-4 2-7-12 31-0-4 8-9-0 3-8-5 3-8-5 8-2-12 4-6-7 8-9-14 0-7-2 10-6-10 1-8-12 13-3-0 2-8-6 17-3-0 4-0-0 19-11-6 2-8-6 21-8-2 1-8-12 22-3-4 0-7-2 26-9-11 4-6-7 31-0-4 4-2-9 1-3-412-3-120-10-112-3-1210.0012 Plate Offsets (X,Y)-- [7:0-3-0,0-2-12], [8:0-3-0,0-2-12], [13:0-5-6,0-2-0] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 17.9/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.72 0.70 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) Attic in -0.19 -0.29 0.01 -0.15 (loc) 14-26 14-26 15 14-15 l/defl >706 >467 n/a 423 L/d 360 240 n/a 360 PLATES MT20 Weight: 422 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x6 SPF No.2 BOT CHORD2x8 SP No.1 *Except* B2: 2x8 SP DSS WEBS2x3 SPF Stud *Except* W3: 2x4 SPF Stud, W1: 2x4 SPF No.2 SLIDERLeft 2x4 SPF Stud -ô 2-6-0 BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 7-8. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. JOINTS1 Brace at Jt(s): 19 REACTIONS.All bearings 0-3-8 except (jt=length) 13=Mechanical, 15=0-4-15. (lb) - Max Horz1=-211(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 13 except 17=-396(LC 57) Max Grav All reactions 250 lb or less at joint(s) except 1=2373(LC 51), 13=4433(LC 51), 17=423(LC 12), 15=3837(LC 51) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-1657/12, 2-27=-3073/52, 3-27=-3030/55, 3-4=-2982/67, 4-28=-2798/70, 5-28=-2776/73, 5-29=-2556/47, 6-29=-2433/75, 6-30=-1515/35, 7-30=-1488/48, 7-31=-1146/26, 8-31=-1146/26, 8-32=-1495/46, 9-32=-1522/30, 9-33=-2368/59, 33-34=-2460/40, 10-34=-3259/51, 10-35=-2368/4, 11-35=-2497/3, 11-12=-3714/1, 12-36=-4286/26, 13-36=-5129/28 BOT CHORD1-18=-24/2267, 17-18=0/2174, 16-17=0/2174, 15-16=0/2174, 14-15=0/2174, 13-14=0/3827 WEBS5-18=-208/462, 10-14=-1886/136, 6-19=-1205/134, 9-19=-1100/103, 12-14=-2178/203 NOTES-(19) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 13-3-0, Exterior(2E) 13-3-0 to 17-3-0, Exterior(2R) 17-3-0 to 21-5-15, Interior(1) 21-5-15 to 31-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (17.9 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=0.93,1.00,0.93; Ct=1.10, Lu=50-0-0 6) Roof design snow load has been reduced to account for slope. 7) Unbalanced snow loads have been considered for this design. 8) Provide adequate drainage to prevent water ponding. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss GT-431 Truss Type Attic Girder Qty 1 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:06 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-HQ_rhduLjME7ucplm?BWGoOc6K3SKFp7DO7SqsyswkR NOTES-(19) 11) Ceiling dead load (10.0 psf) on member(s). 5-6, 9-10, 6-19, 9-19; Wall dead load (5.0psf) on member(s).5-18, 10-14 12) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 17-18, 15-17, 14-15 13) Refer to girder(s) for truss to truss connections. 14) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13 except (jt=lb) 17=396. 15) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 16) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 17) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1517 lb down and 49 lb up at 15-3-0, and 1124 lb down and 36 lb up at 21-10-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. 18) Attic room checked for L/360 deflection. 19) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-56, 5-6=-76, 6-7=-56, 7-8=-58, 8-9=-56, 9-34=-76, 10-34=-296(F=-220), 10-13=-276(F=-220), 18-20=-20, 14-18=-30, 14-24=-20, 6-9=-20 Drag: 5-18=-10, 10-14=-10 Concentrated Loads (lb) Vert: 31=-810(F) 34=-600(F) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss HT-300A Truss Type Diagonal Hip Girder Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:07 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-lcYDuyuzUfM_VmOyKijlp0xrHjRR3k2GS2t?NIyswkQ Scale: 3/8"=1' T1 W1 B1 W3 W2 HW1 W41 2 3 4 7 6 5 3x4 1.5x4 1.5x4 3x4 3x4 1.5x4 1.5x4 TJC37 TJC37 TJC37 TJC37 1-4-15 1-4-15 6-4-2 4-11-2 9-3-10 2-11-9 1-4-15 1-4-15 6-4-2 4-11-2 9-3-10 2-11-9 0-6-84-11-25.6612 LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.50 0.52 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 0.01 (loc) 6 6 5 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 33 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x3 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)5=508/Mechanical, 7=575/0-4-15 (min. 0-1-8) Max Horz7=124(LC 35) Max Uplift5=-167(LC 12), 7=-99(LC 12) Max Grav5=618(LC 18), 7=630(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-409/51, 2-11=-546/88, 3-11=-461/101 BOT CHORD1-7=-36/417, 7-12=-154/417, 6-12=-154/417, 5-6=-154/417 WEBS3-6=-136/373, 3-5=-629/232, 2-7=-394/81 NOTES-(14) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb) 5=167. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Use Simpson Strong-Tie TJC37 (4 nail, 30-90) or equivalent spaced at 2-9-15 oc max. starting at 3-8-13 from the left end to 6-6-12 to connect truss(es) T-401 (1 ply 2x4 SPF), T-405 (1 ply 2x4 SPF) to front face of bottom chord. 11) Use Simpson Strong-Tie TJC37 (4 nail 90-150) or equivalent spaced at 2-9-15 oc max. starting at 3-8-13 from the left end to 6-6-12 to connect truss(es) T-401 (1 ply 2x4 SPF), T-405 (1 ply 2x4 SPF) to back face of bottom chord. 12) Fill all nail holes where hanger is in contact with lumber. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 14) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-59, 5-8=-20 Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss HT-300A Truss Type Diagonal Hip Girder Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:07 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-lcYDuyuzUfM_VmOyKijlp0xrHjRR3k2GS2t?NIyswkQ LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 6=-313(F=-156, B=-156) 12=-48(F=-24, B=-24) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss HT-438 Truss Type Diagonal Hip Girder Qty 2 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:08 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-Dp5b6IvbFzUr7wz8tQE_LDU3b7oeoGDQhicZvkyswkP Scale = 1:20.2 T1 W1 B1 W3 W2 HW1 1 2 3 54 4x4 1.5x4 1.5x4 3x4 3x4 3-2-13 3-2-13 6-1-7 2-10-10 3-2-13 3-2-13 6-1-7 2-10-10 0-6-83-5-25.6612 LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.27 0.46 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 21 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x3 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)4=155/Mechanical, 6=339/0-4-4 (min. 0-1-8) Max Horz6=81(LC 35) Max Uplift4=-68(LC 12), 6=-38(LC 12) Max Grav4=221(LC 18), 6=438(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 14 lb down and 39 lb up at 3-4-9, and 14 lb down and 39 lb up at 3-4-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-59, 4-7=-20 Concentrated Loads (lb) Vert: 5=-22(F=-11, B=-11) DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-401 Truss Type Jack-Closed Qty 2 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:09 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-h?fzJewD0Hcil3YKR7lDuR0HCXDqXjGZwMM6RByswkO Scale = 1:14.0 T1 W1 B1 HW1 1 2 3 1.5x4 1.5x4 3x5 2-6-15 2-6-15 0-6-82-3-28.0012 Plate Offsets (X,Y)-- [1:0-0-10,0-0-14], [1:0-1-3,0-5-5], [1:0-2-8,0-0-5] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.09 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 4 3-4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 9 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 2-6-15 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)3=29/Mechanical, 4=165/0-3-8 (min. 0-1-8) Max Horz4=47(LC 16) Max Uplift3=-36(LC 16) Max Grav3=44(LC 29), 4=221(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-403 Truss Type Jack-Closed Qty 5 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:10 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-ABDLX_xsnakZMD6X?rGSQeZGLxTkGAWj805fzdyswkN Scale = 1:28.7 T1 W1 B1 B2 B3 HW1 1 2 3 6 5 4 3x4 3x4 1.5x4 1.5x4 5x6 3x5 3-2-0 3-2-0 6-8-0 3-6-0 3-2-0 3-2-0 6-8-0 3-6-0 0-6-84-11-133-11-131-0-08.0012 Plate Offsets (X,Y)-- [1:0-2-8,0-0-5], [1:0-1-3,0-5-5], [1:0-0-10,0-0-14], [4:Edge,0-2-8] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.89 0.49 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.10 0.04 (loc) 4-5 4-5 4 l/defl >999 >656 n/a L/d 360 240 n/a PLATES MT20 Weight: 22 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 5-6. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)4=210/Mechanical, 7=305/0-3-8 (min. 0-1-8) Max Horz7=126(LC 16) Max Uplift4=-67(LC 16) Max Grav4=310(LC 22), 7=370(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 2-11-4, Interior(1) 2-11-4 to 6-6-12 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-404 Truss Type Jack-Closed Qty 10 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:11 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-eOnkkKxUYusQ_NhjZYnhzr6UGLqE?dmsNgrDW3yswkM Scale = 1:29.7 T1 W1 B1 HW1 1 2 3 1.5x4 1.5x4 4x6 6-8-0 6-8-0 0-6-84-11-138.0012 Plate Offsets (X,Y)-- [1:0-0-10,0-0-14], [1:0-1-3,0-5-5], [1:0-3-0,0-1-5] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.69 0.40 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.05 -0.09 0.00 (loc) 3-4 3-4 l/defl >999 >707 n/a L/d 360 240 n/a PLATES MT20 Weight: 21 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)3=210/Mechanical, 4=305/0-3-8 (min. 0-1-8) Max Horz4=126(LC 16) Max Uplift3=-67(LC 16) Max Grav3=310(LC 22), 4=370(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-6-12 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-405 Truss Type Jack-Closed Qty 2 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:12 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-6aL6xgy6IC_GcXGv6GIwW3empkDVk40?cKam2WyswkL Scale = 1:20.4 T1 W1 B1 HW1 1 2 3 1.5x4 1.5x4 3x5 4-6-15 4-6-15 0-6-83-7-28.0012 Plate Offsets (X,Y)-- [1:0-0-10,0-0-14], [1:0-1-3,0-5-5], [1:0-2-4,0-0-5] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.25 0.21 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 3-4 3-4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 15 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 4-6-15 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)3=124/Mechanical, 4=228/0-3-8 (min. 0-1-8) Max Horz4=86(LC 16) Max Uplift3=-50(LC 16) Max Grav3=185(LC 22), 4=306(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-5-11 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-407 Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:13 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-amvU90zk3V67Ehr5gzp92GBoh8QeTIs9q_KJayyswkK Scale = 1:61.8 T1 T2 T4 B1 B3 B4 B5 B6 W8 W6 W4W3 W2 W1 W5 W7 W9 HW1 T3 B2 W11W101 2 34567 8 9 18 17 1615 14 13 12 11 10 5x6 3x6 4x6 3x6 3x4 2x4 6x8 4x6 2x4 2x4 3x4 1.5x4 4x10 3x4 5x6 3x4 8x8 4x8 8-8-0 8-8-0 15-6-6 6-10-6 22-6-0 6-11-10 27-3-0 4-9-0 32-9-0 5-6-0 35-0-8 2-3-8 4-5-1 4-5-1 8-8-0 4-2-15 15-6-6 6-10-6 22-6-0 6-11-10 27-3-0 4-9-0 32-9-0 5-6-0 35-0-8 2-3-8 0-6-86-2-06-3-131-1-81-0-06-2-08.0012 Plate Offsets (X,Y)-- [1:0-4-0,Edge], [1:0-2-1,0-10-15], [1:0-0-5,0-1-1], [3:0-3-0,0-2-0], [7:0-3-0,0-2-0], [8:0-1-0,0-1-12], [9:0-2-4,0-1-12], [10:Edge,0-3-8], [12:0-2-12,0-0-0], [14:0-2-4 ,0-3-4], [16:0-2-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.82 0.79 0.99 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.24 -0.41 0.17 (loc) 16-18 15-16 10 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 153 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 *Except* T1: 2x4 SPF 2100F 1.8E, T2: 2x4 SPF 1650F 1.5E BOT CHORD2x4 SPF No.2 *Except* B1: 2x4 SPF 1650F 1.5E, B3: 2x4 SPF Stud WEBS2x3 SPF Stud *Except* W4,W2: 2x4 SPF No.2, W3,W11,W10: 2x4 SPF Stud WEDGE Left: 2x10 SP No.1 BRACING- TOP CHORDStructural wood sheathing directly applied or 2-8-8 oc purlins, except end verticals, and 2-0-0 oc purlins (2-4-4 max.): 3-7. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 11-12. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)10=1334/Mechanical, 1=1405/0-3-8 (min. 0-2-10) Max Horz1=116(LC 15) Max Grav10=1608(LC 45), 1=1682(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-24=-2124/0, 2-24=-2081/0, 2-3=-2179/19, 3-25=-2735/39, 25-26=-2737/38, 4-26=-2737/38, 4-5=-3052/36, 5-27=-3052/36, 6-27=-3052/36, 6-28=-3066/35, 7-28=-3064/35, 7-29=-2584/0, 29-30=-2601/0, 8-30=-2624/0, 8-9=-2912/0, 9-10=-1547/0 BOT CHORD1-18=-73/1602, 18-31=-51/1838, 17-31=-51/1838, 16-17=-51/1838, 6-14=-666/108, 13-14=0/2157, 12-13=0/2530 WEBS2-18=-91/343, 3-18=-97/283, 3-16=-92/1226, 4-16=-1023/141, 14-16=-75/2597, 4-14=-21/369, 7-14=-105/1287, 7-13=0/407, 8-13=-826/137, 9-12=0/2292 NOTES-(12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 8-8-0, Exterior(2R) 8-8-0 to 12-10-15, Interior(1) 12-10-15 to 27-3-0, Exterior(2R) 27-3-0 to 31-5-15, Interior(1) 31-5-15 to 34-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (19.3 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Refer to girder(s) for truss to truss connections. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management.Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-407 Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:13 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-amvU90zk3V67Ehr5gzp92GBoh8QeTIs9q_KJayyswkK LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-59, 3-7=-58, 7-9=-59, 15-19=-20, 12-14=-20, 10-11=-20 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-408 Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:14 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-2zTsMM_MqpE_rrQIEhLObUkz5YjvCnjI3e3t6OyswkJ Scale = 1:62.4 T1 T2 T3 B1 B3 B4 B5 B6W13 W10 W8 W6 W4 W3 W2 W1 W5 W7 W9 B2 W12 W11 1 2 3 4567 8 9 1918 17 1615 14 13 12 11 10 5x6 5x6 4x6 3x6 3x4 2x4 5x8 5x6 2x4 3x4 1.5x4 3x4 4x4 3x4 5x8 3x4 4x4 3x6 4x8 1-0-4 1-0-4 10-8-0 9-7-12 16-8-9 6-0-9 22-6-0 5-9-7 25-3-0 2-9-0 32-9-0 7-6-0 35-0-8 2-3-8 1-0-4 1-0-4 5-9-6 4-9-2 10-8-0 4-10-10 16-8-9 6-0-9 22-6-0 5-9-7 25-3-0 2-9-0 32-9-0 7-6-0 35-0-8 2-3-8 0-6-87-6-07-7-131-1-81-0-07-6-08.0012 Plate Offsets (X,Y)-- [1:0-2-13,0-0-4], [1:0-1-3,0-5-5], [1:0-0-10,0-0-14], [3:0-1-0,0-2-0], [4:0-3-0,0-2-0], [7:0-3-0,0-2-0], [8:0-0-12,0-1-8], [9:0-2-12,0-2-0], [10:Edge,0-1-8], [12:0-2-8 ,0-0-0], [14:0-2-12,0-3-4], [16:0-4-0,0-1-12] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.78 0.98 0.88 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.33 0.16 (loc) 12-13 18-19 10 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 169 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 *Except* T3: 2x4 SPF 2100F 1.8E BOT CHORD2x4 SPF No.2 *Except* B3: 2x4 SPF Stud WEBS2x4 SPF Stud *Except* W13,W8,W6,W5,W7: 2x3 SPF Stud, W4,W11: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 2-4-4 oc purlins, except end verticals, and 2-0-0 oc purlins (2-10-13 max.): 4-7. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 12-13 6-0-0 oc bracing: 11-12. WEBS1 Row at midpt3-19, 8-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)10=1328/Mechanical, 19=1411/0-3-8 (min. 0-2-12) Max Horz19=140(LC 15) Max Grav10=1624(LC 46), 19=1764(LC 46) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-547/0, 2-23=-622/0, 23-24=-519/0, 3-24=-477/6, 3-25=-1988/0, 4-25=-1917/0, 4-26=-2078/0, 5-26=-2080/0, 5-27=-2177/0, 27-28=-2177/0, 6-28=-2177/0, 6-7=-2181/0, 7-29=-2244/0, 29-30=-2252/0, 30-31=-2299/0, 8-31=-2305/0, 8-9=-3021/0, 9-10=-1558/0 BOT CHORD1-19=0/415, 18-19=-58/1581, 17-18=-21/1635, 17-32=-21/1635, 16-32=-21/1635, 6-14=-468/88, 13-14=0/1870, 12-13=-29/2808, 8-12=0/252 WEBS2-19=-418/216, 3-19=-1611/28, 3-18=-254/200, 4-18=0/465, 4-16=-96/759, 5-16=-814/121, 14-16=-35/1931, 7-14=-117/798, 7-13=0/477, 8-13=-1247/207, 9-12=0/2429 NOTES-(12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 10-8-0, Exterior(2R) 10-8-0 to 14-10-15, Interior(1) 14-10-15 to 25-3-0, Exterior(2R) 25-3-0 to 29-5-15, Interior(1) 29-5-15 to 34-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (19.3 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Refer to girder(s) for truss to truss connections. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-408 Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:14 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-2zTsMM_MqpE_rrQIEhLObUkz5YjvCnjI3e3t6OyswkJ 12) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-58, 4-7=-58, 7-9=-59, 15-20=-20, 12-14=-20, 10-11=-20 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-409 Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:16 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-_Lacn1?cMQUi58agL5NsgvpKNMPagfQbXyY_BHyswkH Scale = 1:61.8 T1 T2 T3 B1 W4 W3 W2 W1W1 W2 W3 W4 HW1 B3B2 W8 W5 W7 W6 1 2 3 4 56 7 8 1615 14 1312 11 10 9 3x5 5x6 5x6 4x5 3x6 3x4 4x4 3x8 3x4 3x8 3x4 4x4 4x6 3x5 1.5x4 4x4 6-0-3 6-0-3 12-8-0 6-7-13 23-3-0 10-7-0 29-10-13 6-7-13 35-0-8 5-1-11 6-0-3 6-0-3 12-8-0 6-7-13 17-11-8 5-3-8 23-3-0 5-3-8 29-10-13 6-7-13 35-0-8 5-1-11 0-6-88-10-08-11-131-1-88-10-08.0012 Plate Offsets (X,Y)-- [2:0-2-0,0-1-12], [4:0-3-0,0-2-3], [6:0-3-0,0-2-3], [8:0-2-4,0-1-8], [9:Edge,0-1-8], [10:0-2-0,0-1-8], [15:0-2-0,0-1-8], [16:0-2-4,0-0-12] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.73 0.91 1.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.54 -0.86 0.07 (loc) 12-13 12-13 9 l/defl >750 >473 n/a L/d 360 240 n/a PLATES MT20 Weight: 155 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF 1650F 1.5E *Except* T2: 2x4 SPF No.2 BOT CHORD2x4 SPF No.2 *Except* B2: 2x4 SPF 1650F 1.5E WEBS2x3 SPF Stud *Except* W2,W1: 2x4 SPF No.2, W7: 2x4 SPF Stud WEDGE Left: 2x3 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 3-6-8 oc purlins, except end verticals, and 2-0-0 oc purlins (4-5-1 max.): 4-6. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. WEBS1 Row at midpt5-13, 5-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)9=1330/Mechanical, 16=1409/0-3-8 (min. 0-2-14) Max Horz16=165(LC 15) Max Grav9=1740(LC 46), 16=1824(LC 46) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-285/0, 2-20=-2256/0, 20-21=-2178/0, 3-21=-2060/0, 3-22=-1985/0, 4-22=-1818/9, 4-23=-1509/47, 5-23=-1510/47, 5-24=-1508/46, 6-24=-1507/46, 6-25=-1816/0, 7-25=-1983/0, 7-26=-2055/0, 26-27=-2172/0, 8-27=-2249/0, 8-9=-1638/4 BOT CHORD1-16=0/261, 15-16=-136/377, 14-15=-27/1857, 13-14=-27/1857, 13-28=0/1630, 28-29=0/1630, 12-29=0/1630, 11-12=0/1807, 10-11=0/1807 WEBS3-13=-435/142, 4-13=0/690, 5-13=-391/134, 5-12=-394/133, 6-12=0/690, 7-12=-436/140, 2-16=-1598/62, 2-15=0/1570, 8-10=0/1657 NOTES-(12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 12-8-0, Exterior(2R) 12-8-0 to 16-10-15, Interior(1) 16-10-15 to 23-3-0, Exterior(2R) 23-3-0 to 27-5-15, Interior(1) 27-5-15 to 34-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (19.3 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Refer to girder(s) for truss to truss connections. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) StandardContinued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-409 Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:16 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-_Lacn1?cMQUi58agL5NsgvpKNMPagfQbXyY_BHyswkH LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-59, 4-6=-58, 6-8=-59, 9-17=-20 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-415B Truss Type Common Qty 3 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:17 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-SX8??N0F7kcZiI9tvpu5D6MS6lmaPEXllcIXjjyswkG Scale = 1:73.2 T2 T2 B1 W5 W3 W2 W1 HW1 W2 W3 W4 W7 T1 T3 B3B2 W6 1 2 3 4 5 6 7 8 9 1514 13 1211 10 3x6 5x6 3x6 6x10 4x6 3x4 1.5x4 3x4 3x8 3x4 3x4 4x4 3x6 2x4 4x6 8-9-13 8-9-13 17-11-8 9-1-11 27-1-0 9-1-8 35-0-8 7-11-8 6-1-1 6-1-1 11-5-6 5-4-6 17-11-8 6-6-2 24-5-9 6-6-1 30-9-13 6-4-5 35-0-8 4-2-11 0-6-812-6-31-1-88.0012 Plate Offsets (X,Y)-- [1:0-1-0,0-0-6], [1:0-11-1,0-1-6], [1:Edge,0-3-5], [8:0-1-12,0-2-0], [10:0-2-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.92 0.86 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.58 0.08 (loc) 13-15 13-15 10 l/defl >999 >719 n/a L/d 360 240 n/a PLATES MT20 Weight: 157 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 *Except* T1: 2x4 SPF 2100F 1.8E BOT CHORD2x4 SPF 1650F 1.5E WEBS2x3 SPF Stud *Except* W2,W1: 2x4 SPF No.2, W7,W6: 2x4 SPF Stud WEDGE Left: 2x10 SP No.1 BRACING- TOP CHORDStructural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. WEBS1 Row at midpt4-13, 6-13, 8-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=1405/0-3-8 (min. 0-2-13), 10=1334/Mechanical Max Horz1=231(LC 15) Max Uplift1=-5(LC 16) Max Grav1=1773(LC 29), 10=1683(LC 30) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-2228/34, 2-3=-2061/43, 3-4=-1922/70, 4-21=-1587/91, 21-22=-1475/100, 5-22=-1473/120, 5-23=-1474/120, 23-24=-1474/100, 6-24=-1585/81, 6-7=-1943/54, 7-8=-2126/31, 8-9=-294/29 BOT CHORD1-15=-96/1858, 15-25=-25/1698, 14-25=-25/1698, 14-26=-25/1698, 13-26=-25/1698, 13-27=0/1592, 12-27=0/1592, 12-28=0/1592, 11-28=0/1592, 10-11=0/1660 WEBS4-15=-6/355, 4-13=-644/167, 5-13=-34/1278, 6-13=-644/167, 6-11=0/379, 8-10=-1985/19 NOTES-(11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 17-11-8, Exterior(2R) 17-11-8 to 20-11-8, Interior(1) 20-11-8 to 34-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-421B Truss Type Jack-Closed Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:18 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-xkiNCj1tu2kQKSk3TWPKlKuoq9IH8oVu_G14G9yswkF Scale = 1:13.6 T1 W1 B1 HW1 1 2 3 1.5x4 1.5x4 3x4 3x6 1-4-9 1-4-9 5-0-15 5-0-15 0-6-82-1-63.7112 Plate Offsets (X,Y)-- [1:0-0-0,0-1-3], [1:0-1-5,0-8-3] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.22 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 3-4 3-4 3 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 14 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 5-0-15 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)3=120/Mechanical, 4=270/0-4-15 (min. 0-1-8) Max Horz4=53(LC 15) Max Uplift3=-13(LC 16), 4=-33(LC 12) Max Grav3=159(LC 22), 4=359(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) 0-0-0 to 4-2-15, Exterior(2R) 4-2-15 to 4-11-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-422B Truss Type Jack-Closed Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:18 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-xkiNCj1tu2kQKSk3TWPKlKuqW9Ic8oVu_G14G9yswkF Scale = 1:10.1 T1 W1 B1 HW1 1 2 3 1.5x4 1.5x4 3x4 3x6 1-4-9 1-4-9 3-0-15 3-0-15 0-6-81-5-153.7112 Plate Offsets (X,Y)-- [1:0-0-0,0-1-3], [1:0-1-5,0-8-3] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.11 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 3-4 3-4 3 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 9 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 3-0-15 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)3=15/Mechanical, 4=218/0-4-15 (min. 0-1-8) Max Horz4=33(LC 15) Max Uplift3=-12(LC 13), 4=-35(LC 12) Max Grav3=19(LC 22), 4=273(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-424 Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:19 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-PwGlQ32VfLsHycIF1EwZIXRt8ZZ?tAZ1DwneocyswkE Scale = 1:31.4 T1 T2 T1 B1 W1W1 W2 W2 HW1 1 2 3 4 5 6 10 98 7 4x4 4x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 3x8 3x8 6-5-0 6-5-0 8-10-0 2-5-0 15-3-0 6-5-0 6-5-0 6-5-0 8-10-0 2-5-0 15-3-0 6-5-0 0-6-84-9-130-6-84-9-138.0012 Plate Offsets (X,Y)-- [1:0-3-8,Edge], [1:0-1-3,0-5-5], [1:0-0-10,0-0-14], [3:0-2-4,0-2-4], [4:0-2-4,0-2-4], [6:0-0-10,0-0-14], [6:0-1-3,0-5-5], [6:0-3-8,Edge] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.63 0.41 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.11 0.01 (loc) 7-8 7-8 7 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 47 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x4 SPF Stud , Right: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 5-9-15 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)10=599/0-3-8 (min. 0-1-8), 7=599/0-3-8 (min. 0-1-8) Max Horz10=-79(LC 12) Max Uplift10=-13(LC 13), 7=-13(LC 12) Max Grav10=867(LC 40), 7=867(LC 40) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-377/75, 2-17=-775/148, 17-18=-677/155, 18-19=-657/157, 3-19=-587/180, 3-4=-488/179, 4-20=-587/186, 20-21=-656/164, 21-22=-677/161, 5-22=-775/154, 5-6=-377/75 BOT CHORD1-10=-72/487, 9-10=-77/487, 8-9=-78/488, 7-8=-76/487, 6-7=-76/487 WEBS2-10=-874/219, 5-7=-874/219 NOTES-(12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-5-0, Exterior(2E) 6-5-0 to 8-10-0, Exterior(2R) 8-10-0 to 13-0-15, Interior(1) 13-0-15 to 15-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (19.3 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-424 Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:20 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-t6q7dP27Qf_8ZmtSaxSoql_1uzvEcdpBRaWBK2yswkD LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-3=-58, 3-4=-58, 4-6=-59, 11-14=-20 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-426 Truss Type Jack-Closed Qty 5 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:20 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-t6q7dP27Qf_8ZmtSaxSoql_7Bzydch_BRaWBK2yswkD Scale = 1:19.9 T1 W1 B1 HW1 1 2 3 1.5x4 1.5x4 3x5 4-5-0 4-5-0 0-6-83-5-138.0012 Plate Offsets (X,Y)-- [1:0-0-10,0-0-14], [1:0-1-3,0-5-5], [1:0-2-4,0-0-5] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.23 0.19 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 -0.01 0.00 (loc) 3-4 3-4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 14 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 4-5-0 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)3=117/Mechanical, 4=222/0-3-8 (min. 0-1-8) Max Horz4=83(LC 16) Max Uplift3=-49(LC 16) Max Grav3=169(LC 22), 4=321(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-3-12 zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-427 Truss Type Jack-Closed Qty 4 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:21 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-LJOVql3lBz7?BvSe8fz1NyWK1NK0L8EKgEGlsUyswkC Scale = 1:13.1 T1 W1 B1 1 2 33x4 1.5x4 1.5x4 2-3-15 2-3-15 0-6-82-1-28.0012 LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.10 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 4 3-4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 7 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 2-3-15 oc purlins, except end verticals. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)3=13/Mechanical, 4=161/0-3-8 (min. 0-1-8) Max Horz4=43(LC 16) Max Uplift3=-35(LC 16) Max Grav3=22(LC 29), 4=213(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-428 Truss Type Common Qty 2 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:22 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-pVyu254NyGFsp31qiMUGwA3LqmUq4XyUvu?IPwyswkB Scale = 1:46.9 T1 T1 B1W4 W2 W1 W3 W5B2 HW1 1 2 3 4 5 6 7 11 10 9 8 4x4 3x6 1.5x4 1.5x4 3x8 1.5x4 1.5x4 1.5x4 1.5x4 3x8 3x8 1-3-8 1-3-8 10-8-8 9-5-0 20-2-8 9-6-0 21-5-0 1-2-8 1-3-8 1-3-8 6-3-2 4-11-10 10-8-8 4-5-6 15-2-6 4-5-14 20-2-8 5-0-2 21-5-0 1-2-8 0-6-87-8-30-6-88.0012 Plate Offsets (X,Y)-- [1:0-0-10,0-0-14], [1:0-1-3,0-5-5], [1:0-3-8,Edge], [7:0-0-10,0-0-14], [7:0-1-3,0-5-5], [7:0-3-8,Edge] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.73 0.79 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.25 0.02 (loc) 9 8-9 8 l/defl >999 >919 n/a L/d 360 240 n/a PLATES MT20 Weight: 72 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x3 SPF Stud WEDGE Left: 2x4 SPF Stud , Right: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 4-6-6 oc purlins. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)11=844/0-3-8 (min. 0-1-8), 8=837/0-3-8 (min. 0-1-8) Max Horz11=131(LC 13) Max Uplift11=-4(LC 16), 8=-4(LC 17) Max Grav11=968(LC 2), 8=960(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-623/131, 2-3=-980/224, 3-18=-731/218, 4-18=-673/238, 4-19=-673/238, 5-19=-734/218, 5-6=-990/226, 6-7=-641/136 BOT CHORD1-11=-114/694, 10-11=-120/694, 9-10=-120/694, 8-9=-117/706, 7-8=-117/706 WEBS2-11=-685/185, 4-9=-188/425, 6-8=-666/203 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 10-8-8, Exterior(2R) 10-8-8 to 13-8-8, Interior(1) 13-8-8 to 21-5-0 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 8. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-429 Truss Type Attic Qty 2 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:24 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-lu3eTn6eUuVZ2NBDpnWk?b8dKaA8YHbnMCUPTpyswk9 Scale = 1:74.7 T2 T3 T4 B1 W7 W1 HW1 W6 W8W9 T1 B2 W2W2 B3 W4W4W4W3 W3 W3W3 W3 W3 W3 W5 2 3 4 5 67 8 9 1 25 24 2219161312 23 21 20 18 17 15 14 11 10 26 6x8 8x8 5x6 3x6 3x6 3x8 3x8 3x6 5x8 6x8 3x4 4x5 1.5x4 8x8 3x4 1.5x4 4x6 3x8 1.5x4 3x8 1.5x4 3x8 1.5x4 3x4 3x4 3x4 3x4 13-2-08-1-144-4-10 4-4-12 4-4-10 1-2-05-1-11 5-1-11 9-1-4 3-11-9 10-10-5 1-9-1 12-7-6 1-9-1 14-1-8 1-6-2 14-4-7 0-2-15 17-10-9 3-6-2 18-1-8 0-2-15 19-7-10 1-6-2 20-4-0 0-8-6 21-4-11 1-0-11 22-6-12 1-2-1 22-8-8 0-1-12 5-1-11 5-1-11 9-1-4 3-11-9 9-8-9 0-7-5 14-1-8 4-4-15 18-1-8 4-0-0 20-4-0 2-2-8 22-6-7 2-2-7 22-6-12 0-0-5 22-8-8 0-1-12 0-6-812-3-128-5-151-2-012-3-1210.0012 Plate Offsets (X,Y)-- [1:0-3-8,Edge], [1:Edge,0-0-4], [5:0-2-9,0-1-10], [6:0-5-8,0-3-4], [7:0-5-8,0-3-4], [8:0-1-1,0-0-2], [9:0-3-0,0-2-4], [10:0-3-0,Edge], [13:0-1-12,0-1-8], [26:0-1-14 ,0-1-8] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 17.9/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.99 0.80 0.92 DEFL. Vert(LL) Vert(CT) Horz(CT) Attic in -0.48 -0.89 0.03 -0.24 (loc) 19-22 19-22 12 10-23 l/defl >560 >303 n/a 674 L/d 360 240 n/a 360 PLATES MT20 Weight: 411 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x10 SP No.1 *Except* T3: 2x6 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x4 SPF Stud *Except* W7,W1: 2x4 SPF No.2, W6: 2x4 SPF 2100F 1.8E, W2: 2x3 SPF Stud WEDGE Left: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-7. BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. JOINTS1 Brace at Jt(s): 26, 21, 18, 15 REACTIONS.(lb/size)1=1091/0-3-8 (min. 0-1-8), 12=1277/0-3-8 (min. 0-1-9) Max Horz1=257(LC 16) Max Grav1=1489(LC 49), 12=1980(LC 49) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-31=-1999/0, 31-32=-1916/0, 2-32=-1892/0, 2-3=-1619/0, 3-33=-1429/0, 4-33=-1427/0, 4-34=-405/23, 5-34=-354/54, 5-35=-1168/18, 6-35=-1065/35, 6-7=-1321/40, 7-36=-1160/30, 8-36=-1242/13, 8-9=-917/0, 10-12=-1420/0, 9-10=-1078/0 BOT CHORD1-25=-45/1549, 24-25=-45/1549, 22-24=-45/1549, 19-22=0/2271, 16-19=0/3333, 13-16=0/2565, 12-13=-744/232, 21-23=-759/0, 20-21=-2872/0, 18-20=-2872/0, 17-18=-2913/0, 15-17=-2913/0, 14-15=-1354/79, 11-14=-1354/79, 10-11=-68/1571 WEBS22-23=0/1506, 4-23=0/1655, 5-26=-26/1443, 8-26=-76/657, 2-22=-1653/65, 6-26=-731/23, 7-26=0/792, 21-22=-1560/0, 19-21=0/1115, 18-19=-239/291, 16-18=-406/60, 15-16=0/758, 13-15=-1077/0, 11-13=0/1753, 11-12=-1132/0 NOTES-(16) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x10 - 2 rows staggered at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 1-0-4 to 4-0-4, Interior(1) 4-0-4 to 14-1-8, Exterior(2E) 14-1-8 to 22-6-12 zone; cantilever left exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (17.9 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=0.93,1.00,0.93; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. 6) Roof design snow load has been reduced to account for slope. 7) Unbalanced snow loads have been considered for this design. 8) Provide adequate drainage to prevent water ponding. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-429 Truss Type Attic Qty 2 Ply 2 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:24 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-lu3eTn6eUuVZ2NBDpnWk?b8dKaA8YHbnMCUPTpyswk9 NOTES-(16) 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Ceiling dead load (10.0 psf) on member(s). 4-5, 5-26, 8-26; Wall dead load (5.0psf) on member(s).4-23 12) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 21-23, 20-21, 18-20, 17-18, 15-17, 14-15, 11-14, 10-11 13) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 15) Attic room checked for L/360 deflection. 16) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 4-29=-56, 4-5=-76, 5-6=-56, 6-7=-58, 7-9=-56, 1-12=-20, 5-8=-20, 10-23=-30 Drag: 4-23=-10 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-431 Truss Type Attic Qty 3 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:26 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-iGBOuS7u?VlHHhLbxCYC40D1eOs_0GC3qWzWYiyswk7 Scale = 1:75.2 T2 T3 T2 B1 W4W4 HW1 W2W2 T1 T4 B3 W1 W5W5 W3W3W3W3 W3W3 W3 1 2 3 4 5 6 78 9 10 11 12 13 322927252321191714 312826242220181615 33 5x6 5x6 5x6 4x12 4x8 3x5 12x20 MT18HS 2x4 6x8 3x6 4x5 3x4 4x10 3x4 2x4 2x4 2x4 8x8 1.5x4 1.5x4 8x8 8x8 8x8 8x8 8x8 13-9-08-1-141-2-08-2-12 8-2-12 9-11-13 1-9-1 11-8-14 1-9-1 13-5-15 1-9-1 15-3-0 1-9-1 17-0-1 1-9-1 18-9-2 1-9-1 20-6-3 1-9-1 22-3-4 1-9-1 31-0-4 8-9-0 3-8-5 3-8-5 8-2-12 4-6-7 8-9-14 0-7-2 10-6-10 1-8-12 13-3-0 2-8-6 17-3-0 4-0-0 19-11-6 2-8-6 21-8-2 1-8-12 22-3-4 0-7-2 26-9-11 4-6-7 31-0-4 4-2-9 1-3-412-3-120-10-11-2-012-3-1210.0012 Plate Offsets (X,Y)-- [4:0-3-0,Edge], [7:0-3-0,0-2-12], [8:0-3-0,0-2-12], [9:0-0-14,0-0-0], [10:0-4-11,0-0-12], [13:0-10-0,0-2-3], [22:0-1-12,0-0-0], [32:0-3-8,0-4-4] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 17.9/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.74 0.77 0.59 DEFL. Vert(LL) Vert(CT) Horz(CT) Attic in -0.46 -0.82 -0.03 -0.35 (loc) 18-20 18-20 1 15-31 l/defl >579 >324 n/a 481 L/d 360 240 n/a 360 PLATES MT20 MT18HS Weight: 240 lb FT = 12% GRIP 197/144 197/144 LUMBER- TOP CHORD2x6 SPF No.2 *Except* T2: 2x6 SP 2400F 2.0E BOT CHORD2x8 SP DSS *Except* B2: 2x4 SPF No.2 WEBS2x4 SPF Stud *Except* W4,W1: 2x4 SPF No.2, W2,W5: 2x3 SPF Stud SLIDERLeft 2x4 SPF Stud -ô 2-6-0 BRACING- TOP CHORDStructural wood sheathing directly applied or 2-9-3 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 7-8. BOT CHORDRigid ceiling directly applied or 6-4-3 oc bracing. Except: 6-0-0 oc bracing: 15-31 WEBS1 Row at midpt6-33, 9-33 JOINTS1 Brace at Jt(s): 33 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=1358/Mechanical, 13=1494/Mechanical, 30=348/0-3-8 (min. 0-1-8) Max Horz1=-211(LC 12) Max Uplift30=-71(LC 13) Max Grav1=1866(LC 51), 13=2075(LC 51), 30=808(LC 49) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-641/15, 2-41=-2699/0, 3-41=-2653/0, 3-4=-2622/0, 4-42=-2458/0, 5-42=-2416/0, 5-43=-1866/0, 6-43=-1744/0, 6-44=-446/86, 7-44=-392/108, 7-8=-255/158, 8-45=-377/100, 9-45=-407/79, 9-46=-1710/0, 10-46=-1753/0, 10-47=-2500/0, 11-47=-2502/0, 11-12=-2735/0, 12-48=-2889/0, 13-48=-2985/0 BOT CHORD1-32=0/1803, 30-32=0/1792, 29-30=0/1792, 27-29=0/1792, 25-27=0/1792, 23-25=0/1792, 21-23=0/1850, 19-21=0/1850, 17-19=0/1850, 14-17=0/1850, 13-14=0/2278 WEBS31-32=-24/839, 5-31=-28/914, 14-15=0/993, 10-15=0/1159, 6-33=-2151/0, 9-33=-1976/0, 12-14=-635/111, 22-23=-303/0, 28-29=-351/0 NOTES-(17) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-1-4, Interior(1) 3-1-4 to 13-3-0, Exterior(2E) 13-3-0 to 17-3-0, Exterior(2R) 17-3-0 to 21-7-10, Interior(1) 21-7-10 to 31-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (17.9 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=0.93,1.00,0.93; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Ceiling dead load (10.0 psf) on member(s). 5-6, 9-10, 6-33, 9-33; Wall dead load (5.0psf) on member(s).5-31, 10-15 11) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 28-31, 26-28, 24-26, 22-24, 20-22, 18-20, 16-18, 15-16Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-431 Truss Type Attic Qty 3 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:26 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-iGBOuS7u?VlHHhLbxCYC40D1eOs_0GC3qWzWYiyswk7 NOTES-(17) 12) Refer to girder(s) for truss to truss connections. 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 30. 14) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 15) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16) Attic room checked for L/360 deflection. 17) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-56, 5-6=-76, 6-7=-56, 7-8=-58, 8-9=-56, 9-10=-76, 10-13=-56, 34-38=-20, 6-9=-20, 15-31=-30 Drag: 5-31=-10, 10-15=-10 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-431A Truss Type Attic Qty 6 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:28 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-efJ9I898X6??X_V_2dbg9RJNxBZRUBuMHqSccayswk5 Scale = 1:68.3 T2 T3 T2 B1 W4W4 HW1 W2W2 T1 T4 B3 W1 W5W5 W3W3W3W3W3W3W3 1 2 3 4 5 6 78 9 10 11 12 13 312927252321191714 302826242220181615 33 4x12 5x6 5x6 4x12 5x8 3x5 12x20 MT18HS 3x6 3x6 3x4 4x8 3x4 3x4 2x4 2x4 1.5x4 1.5x4 13-9-08-1-141-2-08-2-12 8-2-12 9-11-13 1-9-1 11-8-14 1-9-1 13-5-15 1-9-1 15-3-0 1-9-1 17-0-1 1-9-1 18-9-2 1-9-1 20-6-3 1-9-1 22-3-4 1-9-1 31-0-4 8-9-0 3-8-5 3-8-5 8-2-12 4-6-7 8-9-14 0-7-2 10-6-10 1-8-12 13-3-0 2-8-6 17-3-0 4-0-0 19-11-6 2-8-6 21-8-2 1-8-12 22-3-4 0-7-2 26-9-11 4-6-7 31-0-4 4-2-9 1-3-412-3-120-10-11-2-012-3-1210.0012 Plate Offsets (X,Y)-- [5:0-4-15,0-0-12], [7:0-3-0,0-2-12], [8:0-3-0,0-2-12], [10:0-5-7,0-0-4], [13:0-8-0,0-0-11], [14:0-3-8,0-5-4], [22:0-1-12,0-0-0], [31:0-3-8,0-5-4] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 17.9/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.76 0.65 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) Attic in -0.48 -0.86 0.04 -0.35 (loc) 22 21-23 13 15-30 l/defl >707 >400 n/a 479 L/d 360 240 n/a 360 PLATES MT20 MT18HS Weight: 240 lb FT = 12% GRIP 197/144 197/144 LUMBER- TOP CHORD2x6 SPF No.2 *Except* T2: 2x6 SP 2400F 2.0E BOT CHORD2x8 SP DSS *Except* B2: 2x4 SPF No.2 WEBS2x4 SPF Stud *Except* W4,W1: 2x4 SPF No.2, W2,W5: 2x3 SPF Stud SLIDERLeft 2x4 SPF Stud -ô 2-6-0 BRACING- TOP CHORDStructural wood sheathing directly applied or 2-6-3 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 7-8. BOT CHORDRigid ceiling directly applied or 9-6-0 oc bracing. Except: 6-0-0 oc bracing: 15-30 WEBS1 Row at midpt6-33, 9-33 JOINTS1 Brace at Jt(s): 33 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=1571/Mechanical, 13=1590/Mechanical, 32=39/0-3-8 (min. 0-1-8) Max Horz1=-211(LC 12) Max Uplift32=-434(LC 57) Max Grav1=2421(LC 51), 13=2228(LC 51), 32=498(LC 56) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-1018/101, 2-41=-3209/0, 3-41=-3166/0, 3-4=-3115/0, 4-42=-2882/0, 5-42=-2880/0, 5-43=-2051/0, 6-43=-1928/0, 6-44=-393/135, 7-44=-339/170, 7-8=-203/264, 8-45=-335/168, 9-45=-375/133, 9-46=-1899/0, 10-46=-2021/0, 10-47=-2862/0, 11-47=-2864/0, 11-12=-3096/0, 12-48=-3213/0, 13-48=-3309/0 BOT CHORD1-32=0/2288, 31-32=0/2288, 29-31=0/2154, 27-29=0/2154, 25-27=0/2154, 23-25=0/2154, 21-23=0/2182, 19-21=0/2182, 17-19=0/2182, 14-17=0/2182, 13-14=0/2498 WEBS30-31=0/1161, 5-30=0/1260, 14-15=0/1196, 10-15=0/1329, 6-33=-2478/0, 9-33=-2401/0, 12-14=-553/135, 28-29=-293/0, 16-17=-280/0 NOTES-(18) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 13-3-0, Exterior(2E) 13-3-0 to 17-3-0, Exterior(2R) 17-3-0 to 21-5-15, Interior(1) 21-5-15 to 31-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (17.9 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=0.93,1.00,0.93; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) All plates are 8x8 MT20 unless otherwise indicated. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Ceiling dead load (10.0 psf) on member(s). 5-6, 9-10, 6-33, 9-33; Wall dead load (5.0psf) on member(s).5-30, 10-15 Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-431A Truss Type Attic Qty 6 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:28 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-efJ9I898X6??X_V_2dbg9RJNxBZRUBuMHqSccayswk5 NOTES-(18) 12) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 28-30, 26-28, 24-26, 22-24, 20-22, 18-20, 16-18, 15-16 13) Refer to girder(s) for truss to truss connections. 14) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 32=434. 15) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 16) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 17) Attic room checked for L/360 deflection. 18) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-56, 5-6=-76, 6-7=-56, 7-8=-58, 8-9=-56, 9-10=-76, 10-13=-56, 34-38=-20, 6-9=-20, 15-30=-30 Drag: 5-30=-10, 10-15=-10 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-433 Truss Type Common Qty 4 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:29 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-6rtXWU9mIQ7s883AcK6vierYLbsDDcZWWTCA80yswk4 Scale = 1:77.7 T2 T2 B1 W4 W3 W2 W1 W2 W3 W4 HW1 T1 T1 B1B2 HW21 2 3 4 5 6 7 8 9 1413 12 11 10 3x6 5x6 3x6 6x8 6x12 4x6 3x4 1.5x4 3x4 3x8 3x4 3x4 1.5x4 3x6 3x8 8-8-3 8-8-3 17-11-8 9-3-5 27-2-12 9-3-4 35-11-0 8-8-4 6-1-1 6-1-1 11-4-14 5-3-13 17-11-8 6-6-10 24-6-2 6-6-10 29-9-15 5-3-13 35-11-0 6-1-1 0-6-812-6-30-6-88.0012 Plate Offsets (X,Y)-- [1:0-0-0,0-1-13], [1:0-2-5,Edge], [6:0-1-12,0-1-8], [9:0-0-10,0-0-14], [9:0-1-3,0-5-5], [9:0-3-8,Edge] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.71 0.87 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.29 -0.47 0.03 (loc) 12-14 12-14 10 l/defl >999 >690 n/a L/d 360 240 n/a PLATES MT20 Weight: 158 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x4 SPF No.2 *Except* W4: 2x3 SPF Stud, W3: 2x4 SPF Stud WEDGE Left: 2x10 SP No.1 , Right: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 3-9-3 oc purlins. BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. WEBS1 Row at midpt4-12, 6-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=992/0-3-8 (min. 0-2-0), 10=1828/0-3-8 (min. 0-3-8) Max Horz1=220(LC 13) Max Uplift1=-22(LC 16), 10=-6(LC 17) Max Grav1=1273(LC 29), 10=2242(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-1479/59, 2-3=-1316/65, 3-4=-1178/97, 4-23=-732/91, 23-24=-620/100, 5-24=-619/120, 5-25=-624/146, 25-26=-630/124, 6-26=-737/117, 6-7=-34/748, 7-8=-67/559, 8-9=-102/549 BOT CHORD1-14=-117/1272, 14-27=-51/1027, 13-27=-51/1027, 13-28=-51/1027, 12-28=-51/1027, 9-10=-354/111 WEBS4-14=-4/468, 4-12=-690/166, 5-12=-61/398, 6-12=0/785, 6-10=-1683/91, 8-10=-370/130 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 17-11-8, Exterior(2R) 17-11-8 to 20-11-8, Interior(1) 20-11-8 to 35-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-433A Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:30 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-a2QvjqAO3kFjmIeNA2d8EsOgb?H2y4Ifl7xjhTyswk3 Scale = 1:68.5 T2 T3 T2 B1 W4 W3 W2 W1 W2 W3 W4 HW1 T1 T4 B3B2 W51 2 3 4 5 6 7 8 15 14 1312 11 10 9 3x6 5x6 5x6 4x8 5x8 3x12 3x6 3x4 1.5x4 3x4 3x10 4x4 2x4 3x5 3x6 5x6 0-1-138-10-0 8-10-0 14-8-0 5-10-0 21-3-0 6-7-0 27-2-12 5-11-12 35-0-8 7-9-12 8-10-0 8-10-0 14-8-0 5-10-0 21-3-0 6-7-0 27-2-12 5-11-12 35-0-8 7-9-12 0-6-810-2-010-3-131-1-810-2-08.0012 Plate Offsets (X,Y)-- [1:0-0-5,0-1-1], [1:0-2-1,0-10-15], [1:0-4-0,Edge], [2:0-1-12,0-1-8], [4:0-3-0,0-2-0], [5:0-3-0,0-2-3], [6:0-4-0,Edge], [7:0-1-12,0-2-0], [9:Edge,0-3-8], [10:0-2-4 ,0-1-0], [12:0-2-4,0-1-8] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.94 0.57 0.59 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.22 0.03 (loc) 12-13 12-13 10 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 159 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 *Except* T3: 2x4 SPF 1650F 1.5E, T4: 2x4 SPF 2100F 1.8E BOT CHORD2x4 SPF 2100F 1.8E *Except* B2: 2x4 SPF No.2 WEBS2x4 SPF Stud *Except* W2,W1: 2x4 SPF No.2 WEDGE Left: 2x10 SP No.1 BRACING- TOP CHORDStructural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-9-13 max.): 4-5. BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. WEBS1 Row at midpt2-13, 4-12, 5-12, 7-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=1007/0-3-8 (min. 0-1-12), 10=1732/0-3-8 (min. 0-3-0) Max Horz1=189(LC 15) Max Uplift1=-15(LC 16) Max Grav1=1386(LC 48), 10=2357(LC 46) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-21=-1595/15, 21-22=-1528/20, 22-23=-1455/51, 2-23=-1293/54, 2-3=-1069/64, 3-24=-1021/66, 4-24=-913/98, 4-25=-403/91, 25-26=-403/91, 26-27=-403/91, 27-28=-403/91, 5-28=-403/91, 5-29=-539/96, 6-29=-566/64, 6-7=-616/62, 7-30=-36/666, 30-31=-68/630, 8-31=-82/425 BOT CHORD1-32=-52/1317, 15-32=-52/1317, 14-15=-52/1317, 13-14=-52/1317, 13-33=-38/804, 12-33=-38/804, 11-12=-367/89, 10-11=-367/89, 10-34=-367/89, 9-34=-367/89 WEBS2-15=0/278, 2-13=-736/145, 4-13=-22/827, 4-12=-740/34, 7-12=0/1053, 7-10=-2029/64 NOTES-(12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 14-8-0, Exterior(2R) 14-8-0 to 18-10-15, Interior(1) 18-10-15 to 21-3-0, Exterior(2R) 21-3-0 to 25-5-15, Interior(1) 25-5-15 to 34-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (19.3 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management.Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-433A Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:30 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-a2QvjqAO3kFjmIeNA2d8EsOgb?H2y4Ifl7xjhTyswk3 LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-58, 4-5=-58, 5-8=-59, 9-16=-20 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-433B Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:32 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-WQYg8WCfbLVR?colHTfcJHT0aoveQzyyCRQqlLyswk1 Scale = 1:70.4 T2 T3 T2 B3 W4 W3 W2 W1 W2 W3 HW1 T1 T1 B2B1 HW2 W4 1 2 3 4 5 6 7 8 14 13 1211 10 9 4x8 5x6 5x6 3x8 3x6 4x5 3x4 1.5x4 3x10 3x5 4x4 6x8 3x12 4x6 2x4 0-1-138-10-0 8-10-0 16-8-0 7-10-0 19-3-0 2-7-0 27-2-12 7-11-12 35-11-0 8-8-4 8-10-0 8-10-0 8-11-12 0-1-12 14-8-0 5-8-4 16-8-0 2-0-0 19-3-0 2-7-0 21-3-0 2-0-0 27-2-12 5-11-12 35-11-0 8-8-4 0-6-811-6-011-7-130-6-811-6-08.0012 Plate Offsets (X,Y)-- [1:Edge,0-3-3], [1:0-11-2,0-0-5], [1:0-1-0,0-0-8], [2:0-1-12,0-1-8], [3:0-4-0,Edge], [4:0-3-0,0-2-3], [5:0-3-0,0-2-0], [7:0-1-8,0-2-0], [8:0-2-8,0-1-5], [8:0-0-10,0-0-14], [8:0-1-3,0-5-5], [9:0-2-4,0-1-0], [11:0-2-4,0-1-8], [12:0-2-8,0-1-8] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0** 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.91 0.82 0.64 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.32 0.03 (loc) 12-14 12-14 9 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 168 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF 1650F 1.5E *Except* T3: 2x4 SPF No.2, T1: 2x4 SPF 2100F 1.8E BOT CHORD2x4 SPF 1650F 1.5E *Except* B3: 2x4 SPF 2100F 1.8E, B2: 2x4 SPF No.2 WEBS2x4 SPF No.2 *Except* W4: 2x4 SPF Stud WEDGE Left: 2x10 SP No.1 , Right: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 2-2-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. WEBS1 Row at midpt2-12, 4-12, 5-11, 7-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=982/0-3-8 (min. 0-2-3), 9=1838/0-3-8 (min. 0-3-4) Max Horz1=203(LC 13) Max Uplift1=-22(LC 16), 9=-1(LC 17) Max Grav1=1412(LC 48), 9=2553(LC 46) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-23=-1692/22, 23-24=-1646/32, 2-24=-1464/61, 2-25=-1040/63, 3-25=-866/78, 3-26=-830/82, 26-27=-793/86, 4-27=-793/109, 4-5=-680/135, 5-28=-608/126, 28-29=-627/102, 6-29=-658/98, 6-30=-694/94, 7-30=-869/79, 7-31=-66/725, 31-32=-98/554, 8-32=-110/535 BOT CHORD1-33=-79/1438, 14-33=-79/1438, 13-14=-79/1438, 12-13=-79/1438, 11-12=0/584, 10-11=-461/128, 10-34=-461/128, 9-34=-461/128, 9-35=-461/128, 8-35=-461/128 WEBS2-14=0/404, 2-12=-882/158, 5-12=-56/742, 5-11=-658/63, 7-11=0/1197, 7-9=-2210/94 NOTES-(12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 16-8-0, Exterior(2E) 16-8-0 to 19-3-0, Exterior(2R) 19-3-0 to 23-5-15, Interior(1) 23-5-15 to 35-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) ** TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps= varies (19.3 psf Lum DOL=1.15 Plate DOL=1.15) see load cases; Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management.Continued on page 2 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-433B Truss Type Hip Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:32 2019 Page 2 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-WQYg8WCfbLVR?colHTfcJHT0aoveQzyyCRQqlLyswk1 LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-59, 4-5=-58, 5-8=-59, 15-18=-20 DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-434 Truss Type Common Qty 2 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:33 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-?c62MrCHMfdIdlNxrAArsU0ENCEP9QZ5R5ANHoyswk0 Scale = 1:77.7 T2 T2 B1 W4 W3 W2 W2 W1 HW1 W3 W4 T1 T1 B2B1 HW21 2 3 4 5 6 7 8 9 1413 12 11 10 3x6 5x6 3x6 3x6 3x6 3x4 1.5x4 3x4 3x8 3x4 5x8 5x12 3x4 1.5x4 4x6 8-8-3 8-8-3 17-11-8 9-3-5 27-2-12 9-3-4 35-11-0 8-8-4 6-1-1 6-1-1 11-4-14 5-3-13 17-11-8 6-6-10 24-6-2 6-6-10 29-9-15 5-3-13 35-11-0 6-1-1 0-6-812-6-30-6-88.0012 Plate Offsets (X,Y)-- [1:0-2-5,Edge], [1:0-0-0,0-0-14], [6:0-1-12,0-1-8], [9:0-0-10,0-0-14], [9:0-1-3,0-5-5], [9:0-2-9,0-0-4] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.71 0.85 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.43 0.02 (loc) 12-14 12-14 10 l/defl >999 >769 n/a L/d 360 240 n/a PLATES MT20 Weight: 158 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF 2100F 1.8E *Except* B2: 2x4 SPF No.2 WEBS2x4 SPF No.2 *Except* W4: 2x3 SPF Stud, W3: 2x4 SPF Stud WEDGE Left: 2x10 SP No.1 , Right: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 3-10-12 oc purlins. BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing. WEBS1 Row at midpt4-12, 6-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=992/0-3-8 (min. 0-1-10), 10=1828/0-3-8 (min. 0-2-14) Max Horz1=-220(LC 14) Max Uplift1=-22(LC 16), 10=-6(LC 17) Max Grav1=1273(LC 29), 10=2242(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-1481/58, 2-3=-1318/65, 3-4=-1180/97, 4-23=-730/91, 23-24=-618/100, 5-24=-617/120, 5-25=-622/147, 25-26=-629/124, 6-26=-736/118, 6-7=-35/747, 7-8=-67/558, 8-9=-102/548 BOT CHORD1-14=-117/1277, 14-27=-51/1026, 13-27=-51/1026, 13-28=-51/1026, 12-28=-51/1026, 9-10=-357/113 WEBS4-14=-3/473, 4-12=-691/165, 6-12=0/781, 5-12=-61/396, 6-10=-1680/92, 8-10=-363/130 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 17-11-8, Exterior(2R) 17-11-8 to 20-11-8, Interior(1) 20-11-8 to 35-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-435 Truss Type Common Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:34 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-TpgQZBDv7yl9Fvy8Pti4PiZOQcZAurnFglvxqEyswk? Scale = 1:77.2 T2 T2 B1 W4 W3 W2 W2 W5 W1 HW1 W3 W4 T1 T1 B2B1 HW21 2 3 4 5 6 7 8 9 15 14 13 12 11 10 3x6 5x6 3x6 3x6 3x6 3x4 1.5x4 3x4 3x8 3x4 1.5x4 4x4 5x8 3x12 4x4 4x6 8-8-3 8-8-3 17-11-8 9-3-5 27-2-12 9-3-4 35-11-0 8-8-4 6-1-1 6-1-1 11-4-14 5-3-13 17-11-8 6-6-10 24-6-2 6-6-10 29-9-15 5-3-13 35-11-0 6-1-1 0-6-812-6-30-6-88.0012 Plate Offsets (X,Y)-- [1:0-4-0,Edge], [1:0-2-1,0-10-15], [1:0-0-5,0-1-1], [8:0-1-8,0-2-0], [9:0-2-13,0-0-4], [9:0-1-3,0-5-5], [9:0-0-10,0-0-14], [10:0-1-15,0-1-12], [11:0-2-0,0-1-12] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.82 0.94 0.81 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.31 -0.51 0.04 (loc) 13-15 13-15 10 l/defl >999 >690 n/a L/d 360 240 n/a PLATES MT20 Weight: 162 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 BOT CHORD2x4 SPF No.2 WEBS2x4 SPF No.2 *Except* W4: 2x3 SPF Stud, W3,W5: 2x4 SPF Stud WEDGE Left: 2x10 SP No.1 , Right: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 2-11-15 oc purlins. BOT CHORDRigid ceiling directly applied or 2-2-0 oc bracing. WEBS1 Row at midpt4-13, 6-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)10=1704/0-4-15 (min. 0-3-4), 1=1116/0-3-8 (min. 0-2-4) Max Horz1=220(LC 13) Max Uplift10=-6(LC 17), 1=-17(LC 16) Max Grav10=2090(LC 3), 1=1423(LC 29) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-1703/51, 2-3=-1540/58, 3-4=-1402/90, 4-24=-988/86, 24-25=-875/93, 5-25=-874/115, 5-26=-880/137, 26-27=-887/115, 6-27=-993/108, 7-8=-264/72, 8-9=-76/504 BOT CHORD1-15=-111/1449, 15-28=-44/1229, 14-28=-44/1229, 14-29=-44/1229, 13-29=-44/1229, 13-30=0/525, 12-30=0/525, 12-31=0/525, 11-31=0/525, 10-11=-672/99, 9-10=-325/95 WEBS4-15=-6/429, 4-13=-672/167, 6-13=-12/424, 8-10=-1956/29, 5-13=-51/609, 6-11=-1107/71, 8-11=0/1493 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 17-11-8, Exterior(2R) 17-11-8 to 20-11-8, Interior(1) 20-11-8 to 35-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 1. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-436 Truss Type Common Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:35 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-x?EomXEXuGt0s3XKzbDJxv5Xc0tpdJyOuPfUMgyswk_ Scale = 1:77.7 T2 T2 B1 W4 W3 W2 W2 W5HW1 W1 W3 W4 T1 T1 B2B1 HW21 2 3 4 5 6 7 8 9 1514 13 1211 10 3x6 5x6 3x6 4x6 3x6 3x4 1.5x4 3x4 3x8 3x4 1.5x4 3x5 6x8 3x12 3x5 4x6 8-8-3 8-8-3 17-11-8 9-3-5 27-2-12 9-3-4 30-11-10 3-8-14 35-11-0 4-11-6 6-1-1 6-1-1 11-4-14 5-3-13 17-11-8 6-6-10 24-6-2 6-6-10 29-9-15 5-3-13 35-11-0 6-1-1 0-6-812-6-30-6-88.0012 Plate Offsets (X,Y)-- [1:0-4-0,Edge], [1:0-2-1,0-10-15], [1:0-0-5,0-1-1], [9:0-2-13,0-0-4], [9:0-1-3,0-5-5], [9:0-0-10,0-0-14], [10:0-2-10,0-0-12], [11:0-1-8,0-1-8] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.92 0.98 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.32 -0.53 0.05 (loc) 13-15 13-15 10 l/defl >999 >694 n/a L/d 360 240 n/a PLATES MT20 Weight: 162 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 *Except* T1: 2x4 SPF 1650F 1.5E BOT CHORD2x4 SPF No.2 WEBS2x4 SPF No.2 *Except* W4: 2x3 SPF Stud, W3,W5: 2x4 SPF Stud WEDGE Left: 2x10 SP No.1 , Right: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORDRigid ceiling directly applied or 2-2-0 oc bracing. WEBS1 Row at midpt4-13, 6-13, 6-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)10=1610/0-4-15 (min. 0-3-2), 1=1210/0-3-8 (min. 0-2-7) Max Horz1=-220(LC 12) Max Uplift10=-5(LC 17), 1=-13(LC 16) Max Grav10=1975(LC 30), 1=1537(LC 29) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-1874/45, 2-3=-1710/52, 3-4=-1572/84, 4-24=-1181/86, 24-25=-1069/93, 5-25=-1068/115, 5-26=-1072/130, 26-27=-1079/108, 6-27=-1186/101, 6-7=-707/72, 7-8=-862/40, 8-9=-63/466 BOT CHORD1-15=-107/1582, 15-28=-39/1381, 14-28=-39/1381, 14-29=-39/1381, 13-29=-39/1381, 13-30=0/868, 12-30=0/868, 12-31=0/868, 11-31=0/868, 9-10=-298/86 WEBS4-15=-7/403, 4-13=-661/167, 8-10=-1862/41, 5-13=-43/823, 6-11=-666/47, 8-11=0/1031 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 17-11-8, Exterior(2R) 17-11-8 to 20-11-8, Interior(1) 20-11-8 to 35-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 1. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard DE Job# 67051-W3 Dansco Engineering, LLC COA: 02356 Date: 7/30/19 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job RIVERSIDE Truss T-437 Truss Type Common Qty 1 Ply 1 D4 Elev (A or B) with (SP or SR), EP, and BR Job Reference (optional) Run: 8.310 s May 22 2019 Print: 8.310 s May 22 2019 MiTek Industries, Inc. Tue Jul 30 09:45:36 2019 Page 1 Stark Truss, Marysville, Ohio ID:bSkmYHNGKLZiY4ZpeCGwTQzjQkM-PBoA_tF9fa0tUD6WWIkYU7eiUQDjMqUY73O1t7yswjz Scale = 1:77.7 T2 T2 B1 W4 W3 W2 W2 HW1 W1 W3 W4 T1 T1 B2B1 W5 HW21 2 3 4 5 6 7 8 9 1514 13 1211 10 3x6 5x6 3x6 4x6 3x6 3x4 1.5x4 3x4 3x8 3x4 6x8 3x12 3x4 3x4 4x6 3x4 8-8-3 8-8-3 17-11-8 9-3-5 27-2-12 9-3-4 32-11-10 5-8-14 35-11-0 2-11-6 6-1-1 6-1-1 11-4-14 5-3-13 17-11-8 6-6-10 24-6-2 6-6-10 29-9-15 5-3-13 35-11-0 6-1-1 0-6-812-6-30-6-88.0012 Plate Offsets (X,Y)-- [1:0-4-0,Edge], [1:0-2-1,0-10-15], [1:0-0-5,0-1-1], [9:0-0-10,0-0-14], [9:0-1-3,0-5-5], [9:0-2-13,0-0-4] LOADING (psf) TCLL (roof) Snow (Ps/Pg) TCDL BCLL BCDL 25.0 19.3/25.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.85 1.00 0.48 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.33 -0.54 0.06 (loc) 13-15 13-15 10 l/defl >999 >725 n/a L/d 360 240 n/a PLATES MT20 Weight: 163 lb FT = 12% GRIP 197/144 LUMBER- TOP CHORD2x4 SPF No.2 *Except* T1: 2x4 SPF 2100F 1.8E BOT CHORD2x4 SPF 1650F 1.5E *Except* B2: 2x4 SPF No.2 WEBS2x4 SPF No.2 *Except* W4: 2x3 SPF Stud, W3,W5: 2x4 SPF Stud WEDGE Left: 2x10 SP No.1 , Right: 2x4 SPF Stud BRACING- TOP CHORDStructural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORDRigid ceiling directly applied or 1-4-12 oc bracing. WEBS1 Row at midpt4-13, 6-13, 6-11, 8-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=1315/0-3-8 (min. 0-2-10), 10=1504/0-4-15 (min. 0-2-14) Max Horz1=220(LC 15) Max Uplift1=-9(LC 16), 10=-5(LC 17) Max Grav1=1665(LC 29), 10=1866(LC 30) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD1-2=-2067/39, 2-3=-1902/45, 3-4=-1765/77, 4-24=-1400/88, 24-25=-1288/97, 5-25=-1287/117, 5-26=-1288/123, 26-27=-1294/101, 6-27=-1401/94, 6-7=-1385/71, 7-8=-1540/38, 8-9=-45/343 BOT CHORD1-15=-102/1731, 15-28=-33/1553, 14-28=-33/1553, 14-29=-33/1553, 13-29=-33/1553, 13-30=0/1257, 12-30=0/1257, 12-31=0/1257, 11-31=0/1257, 10-11=0/962 WEBS4-15=-7/377, 4-13=-650/167, 6-13=-342/166, 5-13=-35/1063, 8-11=0/483, 8-10=-1991/30 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 17-11-8, Exterior(2R) 17-11-8 to 20-11-8, Interior(1) 20-11-8 to 35-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=25.0 psf (roof LL: Lum DOL=1.25 Plate DOL=1.25); Pg=25.0 psf; Ps=19.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Roof design snow load has been reduced to account for slope. 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) WARNING! Property of: Stark Truss Co., Inc.This document not for copy or distribution without prior consent of management. LOAD CASE(S) Standard